Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2020

01-09-2020 | KNEE

Do the increment of femoral condyle curvature and the change of tibia shape improve clinical outcome in total knee arthroplasty? A propensity score matching analysis

Authors: Jong-Keun Kim, Jae-Young Park, Han-Jin Lee, Du Hyun Ro, Hyuk-Soo Han, Myung Chul Lee

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 9/2020

Login to get access

Abstract

Purpose

Recently, the Persona total knee arthroplasty (TKA) system with more anatomical features and a similarly high flexion to the previous version, LPS-Flex, was introduced and is widely used. This study aimed to compare the early outcomes obtained using Persona versus an LPS-Flex fixed PS implant.

Methods

A total of 784 knees that underwent primary TKAs (162: Persona group and 622: LPS-Flex group) were included. After 1:2 propensity score matching, there were 143 and 286 knees in Persona and LPS-Flex groups, respectively. Range of motion at the 2-year follow-up was the primary variable. Secondary variables were functional score, ability to perform activities requiring deep knee flexion, patient satisfaction, and radiographic measurements, including radiolucent line (RLL).

Results

The average postoperative maximal flexion measured by goniometer at 2 years after TKA was 126.1° ± 10.8° (range 95°–140°) for the Persona group and 132.7° ± 11.7° (range 103°–145°) for the LPS-Flex group (P < 0.05). This significant difference was observed from 1 year postoperatively (P < 0.05). The two groups did not show a significant difference in functional score, postoperative ability in high flexion activities, and satisfaction at the 2-year follow-up. The rate of RLL was significantly lower in the Persona group (P < 0.05).

Conclusion

At the 2-year follow-up, the Persona group had less maximal flexion; however, the difference in flexion did not seem to affect clinical outcomes. According to the radiological results, the Persona system shows less RLL than does the LPS-Flex system.

Level of evidence

III.
Literature
1.
go back to reference Anouchi YS, McShane M, Kelly F Jr, Elting J, Stiehl J (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92CrossRef Anouchi YS, McShane M, Kelly F Jr, Elting J, Stiehl J (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92CrossRef
2.
go back to reference Bauman RD, Johnson DR, Menge TJ, Kim RH, Dennis DA (2012) Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure? Clin Orthop Relat Res 470:150–158CrossRef Bauman RD, Johnson DR, Menge TJ, Kim RH, Dennis DA (2012) Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure? Clin Orthop Relat Res 470:150–158CrossRef
3.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
4.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty: influence of posterior condylar offset. J Bone Jt Surg Br 84:50–53CrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty: influence of posterior condylar offset. J Bone Jt Surg Br 84:50–53CrossRef
5.
go back to reference Cho S-D, Youm Y-S, Park K-B (2011) Three-to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc 19:899–903CrossRef Cho S-D, Youm Y-S, Park K-B (2011) Three-to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc 19:899–903CrossRef
6.
go back to reference Dai Y, Scuderi GR, Penninger C, Bischoff JE, Rosenberg A (2014) Increased shape and size offerings of femoral components improve fit during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:2931–2940CrossRef Dai Y, Scuderi GR, Penninger C, Bischoff JE, Rosenberg A (2014) Increased shape and size offerings of femoral components improve fit during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:2931–2940CrossRef
7.
go back to reference Devers BN, Conditt MA, Jamieson ML, Driscoll MD, Noble PC, Parsley BS (2011) Does greater knee flexion increase patient function and satisfaction after total knee arthroplasty? J Arthroplast 26:178–186CrossRef Devers BN, Conditt MA, Jamieson ML, Driscoll MD, Noble PC, Parsley BS (2011) Does greater knee flexion increase patient function and satisfaction after total knee arthroplasty? J Arthroplast 26:178–186CrossRef
8.
go back to reference Edwards JZ, Greene KA, Davis RS, Kovacik MW, Noe DA, Askew MJ (2004) Measuring flexion in knee arthroplasty patients. J Arthroplast 19:369–372CrossRef Edwards JZ, Greene KA, Davis RS, Kovacik MW, Noe DA, Askew MJ (2004) Measuring flexion in knee arthroplasty patients. J Arthroplast 19:369–372CrossRef
9.
go back to reference Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
10.
go back to reference Francis JJ, Pankratz VS, Huddleston JM (2001) Patient satisfaction associated with correct identification of physicians’ photograph. Mayo Clin Proc 76(6):604–608CrossRef Francis JJ, Pankratz VS, Huddleston JM (2001) Patient satisfaction associated with correct identification of physicians’ photograph. Mayo Clin Proc 76(6):604–608CrossRef
11.
go back to reference Galea VP, Botros MA, Madanat R, Nielsen CS, Bragdon C (2019) Promising early outcomes of a novel anatomic knee system. Knee Surg Sports Traumatol Arthrosc 27:1067–1074CrossRef Galea VP, Botros MA, Madanat R, Nielsen CS, Bragdon C (2019) Promising early outcomes of a novel anatomic knee system. Knee Surg Sports Traumatol Arthrosc 27:1067–1074CrossRef
12.
go back to reference Gandhi R, Tso P, Davey JR, Mahomed NN (2009) High-flexion implants in primary total knee arthroplasty: a meta-analysis. Knee 16:14–17CrossRef Gandhi R, Tso P, Davey JR, Mahomed NN (2009) High-flexion implants in primary total knee arthroplasty: a meta-analysis. Knee 16:14–17CrossRef
14.
go back to reference Han HS, Kang S-B, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89:1457–1461CrossRef Han HS, Kang S-B, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89:1457–1461CrossRef
15.
go back to reference Hancock GE, Hepworth T, Wembridge K (2018) Accuracy and reliability of knee goniometry methods. J Exp Orthop 5:46CrossRef Hancock GE, Hepworth T, Wembridge K (2018) Accuracy and reliability of knee goniometry methods. J Exp Orthop 5:46CrossRef
16.
go back to reference Hawker G, Wright J, Coyte P, Paul J, Dittus R, Croxford R (1998) Health-related quality of life after knee replacement. Results of the knee replacement patient outcomes research team study. J Bone Jt Surg Am 80:163–173CrossRef Hawker G, Wright J, Coyte P, Paul J, Dittus R, Croxford R (1998) Health-related quality of life after knee replacement. Results of the knee replacement patient outcomes research team study. J Bone Jt Surg Am 80:163–173CrossRef
17.
go back to reference Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplast 20:674–679CrossRef Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplast 20:674–679CrossRef
18.
go back to reference Indelli PF, Risitano S, Hall KE, Leonardi E, Migliore E (2019) Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 27:1028–1034CrossRef Indelli PF, Risitano S, Hall KE, Leonardi E, Migliore E (2019) Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 27:1028–1034CrossRef
19.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14 Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14
20.
go back to reference Jeon YS, Shin JS, Jung JH, Kim MK (2016) Total knee arthroplasty using NexGen LPS-flex(R) improves clinical outcomes without early loosening: minimum 6-year follow-up results. J Orthop Surg Res 11:83CrossRef Jeon YS, Shin JS, Jung JH, Kim MK (2016) Total knee arthroplasty using NexGen LPS-flex(R) improves clinical outcomes without early loosening: minimum 6-year follow-up results. J Orthop Surg Res 11:83CrossRef
21.
go back to reference Jin C, Song E-K, Prakash J, Kim S-K, Chan CK, Seon J-K (2017) How much does the anatomical tibial component improve the bony coverage in total knee arthroplasty? J Arthroplast 32:1829–1833CrossRef Jin C, Song E-K, Prakash J, Kim S-K, Chan CK, Seon J-K (2017) How much does the anatomical tibial component improve the bony coverage in total knee arthroplasty? J Arthroplast 32:1829–1833CrossRef
22.
go back to reference Kim J, Nelson CL, Lotke PA (2004) Stiffness after total knee arthroplasty: prevalence of the complication and outcomes of revision. J Bone Jt Surg Am 86:1479–1484CrossRef Kim J, Nelson CL, Lotke PA (2004) Stiffness after total knee arthroplasty: prevalence of the complication and outcomes of revision. J Bone Jt Surg Am 86:1479–1484CrossRef
23.
go back to reference Malviya A, Lingard E, Weir D, Deehan DJ (2009) Predicting range of movement after knee replacement: the importance of posterior condylar offset and tibial slope. Knee Surg Sports Traumatol Arthrosc 17:491–498CrossRef Malviya A, Lingard E, Weir D, Deehan DJ (2009) Predicting range of movement after knee replacement: the importance of posterior condylar offset and tibial slope. Knee Surg Sports Traumatol Arthrosc 17:491–498CrossRef
24.
go back to reference Mathijssen N, Verburg H, London N, Landsiedl M, Dominkus M (2019) Patient reported outcomes and implant survivorship after total knee arthroplasty with the persona knee implant system: two year follow up. BMC Musculoskelet Disord 20:97CrossRef Mathijssen N, Verburg H, London N, Landsiedl M, Dominkus M (2019) Patient reported outcomes and implant survivorship after total knee arthroplasty with the persona knee implant system: two year follow up. BMC Musculoskelet Disord 20:97CrossRef
25.
go back to reference Matsumoto T, Takayama K, Ishida K, Hayashi S, Hashimoto S, Kuroda R (2017) Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Jt J 99:640–646CrossRef Matsumoto T, Takayama K, Ishida K, Hayashi S, Hashimoto S, Kuroda R (2017) Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Jt J 99:640–646CrossRef
26.
go back to reference Meftah M, White PB, Ranawat AS, Ranawat CS (2016) Long-term results of total knee arthroplasty in young and active patients with posterior stabilized design. Knee 23:318–321CrossRef Meftah M, White PB, Ranawat AS, Ranawat CS (2016) Long-term results of total knee arthroplasty in young and active patients with posterior stabilized design. Knee 23:318–321CrossRef
27.
go back to reference Morra EA, Rosca M, Greenwald JF, Greenwald AS (2008) The influence of contemporary knee design on high flexion: a kinematic comparison with the normal knee. J Bone Jt Surg Am 90:195–201CrossRef Morra EA, Rosca M, Greenwald JF, Greenwald AS (2008) The influence of contemporary knee design on high flexion: a kinematic comparison with the normal knee. J Bone Jt Surg Am 90:195–201CrossRef
28.
go back to reference Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198CrossRef Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198CrossRef
29.
go back to reference Park KK, Chang CB, Kang YG, Seong SC, Kim TK (2007) Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients. J Bone Jt Surg Br 89:604–608CrossRef Park KK, Chang CB, Kang YG, Seong SC, Kim TK (2007) Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients. J Bone Jt Surg Br 89:604–608CrossRef
30.
go back to reference Ranawat CS, Shine JJ (1973) Duo-condylar total knee arthroplasty. Clin Orthop Relat Re 94:185–195CrossRef Ranawat CS, Shine JJ (1973) Duo-condylar total knee arthroplasty. Clin Orthop Relat Re 94:185–195CrossRef
31.
go back to reference Ranawat CS, White PB, West S, Ranawat AS (2017) Clinical and radiographic results of attune and PFC sigma knee designs at 2-year follow-up: a prospective matched-pair analysis. J Arthroplast 32:431–436CrossRef Ranawat CS, White PB, West S, Ranawat AS (2017) Clinical and radiographic results of attune and PFC sigma knee designs at 2-year follow-up: a prospective matched-pair analysis. J Arthroplast 32:431–436CrossRef
32.
go back to reference Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplast 2:95–97CrossRef Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplast 2:95–97CrossRef
33.
go back to reference Ritter MA, Herbst SA, Keating EM, Faris PM (1994) Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Jt Surg Am 76:60–65CrossRef Ritter MA, Herbst SA, Keating EM, Faris PM (1994) Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Jt Surg Am 76:60–65CrossRef
34.
go back to reference Tanavalee A, Ngarmukos S, Tantavisut S, Limtrakul A (2011) High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up. Int Orthop 35:1321–1326CrossRef Tanavalee A, Ngarmukos S, Tantavisut S, Limtrakul A (2011) High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up. Int Orthop 35:1321–1326CrossRef
35.
go back to reference Van de Groes S, de Waal-Malefijt M, Verdonschot N (2014) Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques. Knee 21:209–215CrossRef Van de Groes S, de Waal-Malefijt M, Verdonschot N (2014) Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques. Knee 21:209–215CrossRef
36.
go back to reference Zelle J, Janssen D, Van Eijden J, De Waal Malefijt M, Verdonschot N (2011) Does high-flexion total knee arthroplasty promote early loosening of the femoral component? J Orthop Res 29:976–983CrossRef Zelle J, Janssen D, Van Eijden J, De Waal Malefijt M, Verdonschot N (2011) Does high-flexion total knee arthroplasty promote early loosening of the femoral component? J Orthop Res 29:976–983CrossRef
37.
go back to reference Zelle J, van de Groes S, de Waal Malefijt M, Verdonschot N (2014) Femoral loosening of high-flexion total knee arthroplasty: the effect of posterior cruciate ligament retention and bone quality reduction. Med Eng Phys 36:318–324CrossRef Zelle J, van de Groes S, de Waal Malefijt M, Verdonschot N (2014) Femoral loosening of high-flexion total knee arthroplasty: the effect of posterior cruciate ligament retention and bone quality reduction. Med Eng Phys 36:318–324CrossRef
Metadata
Title
Do the increment of femoral condyle curvature and the change of tibia shape improve clinical outcome in total knee arthroplasty? A propensity score matching analysis
Authors
Jong-Keun Kim
Jae-Young Park
Han-Jin Lee
Du Hyun Ro
Hyuk-Soo Han
Myung Chul Lee
Publication date
01-09-2020
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 9/2020
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-019-05727-5

Other articles of this Issue 9/2020

Knee Surgery, Sports Traumatology, Arthroscopy 9/2020 Go to the issue