Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes

Authors: Pier Francesco Indelli, Salvatore Risitano, Kimberly E. Hall, Erika Leonardi, Eleonora Migliore

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2019

Login to get access

Abstract

Purpose

Total knee arthroplasty is a successful procedure in treating subjects with end-stage knee osteoarthritis. The objective of this matched study was to evaluate subjective patient satisfaction and clinical and radiological outcomes in two groups of patients undergoing primary TKA using an identical third-generation design with different conformity in the polyethylene insert.

Methods

One hundred consecutive patients undergoing TKA because of knee osteoarthritis were randomized in two matched groups. Group A included 50 Posterior-Stabilized (PS) implants, while group B included 50 Medially Congruent (MC) implants. The surgical technique was identical: gap balancing in extension and measured resection in flexion; cruciate ligaments were always removed; the coronal alignment followed the mechanical axis and the tibial slope was set at 3° in the PS group and 5° in the MC. Oxford Knee Score (OKS) and Knee Society Score (KSS) were assessed preoperatively and at 2 year minimum follow-up. Two-sample T test statistical analysis was performed.

Results

All patients were available at final follow-up: there were no preoperative statistical differences between the two groups in the average preoperative ROM (PS 112°, MC 108°; n.s.), average preoperative KSS (PS 64.4, MC 63.7; n.s.), average preoperative OKS (PS 19.6; MC 19.0; n.s.), and average BMI (PS 34.40, MC 34.60; n.s.). At final follow-up, there were no statistical differences between the two groups in the average OKS (PS 40,5; MC 41.1; n.s.) and in the average KSS (PS 161,5, MC 165,7; n.s.). We found a statistically but not clinically significant difference at final ROM: the average maximum active flexion was 120° in the PS group and 123° in the MC group (s.s.).

Conclusion

This study evaluated two biomechanically different polyethylene inserts in the same TKA design, showing that reducing the level of intra-articular conformity had minimal effects on PROMs and objective short-term clinical results but a potentially beneficial effect on ROM. This study suggests that, once a satisfactory intra-operative stability is obtained, the minimal level of constraint should be used.

Level of evidence

III.
Literature
1.
go back to reference Chatterji U, Ashworth MJ, Lewis PL, Dobson PJ (2005) Effect of total knee arthroplasty on recreational and sporting activity. ANZ J Surg 75:405–408CrossRefPubMed Chatterji U, Ashworth MJ, Lewis PL, Dobson PJ (2005) Effect of total knee arthroplasty on recreational and sporting activity. ANZ J Surg 75:405–408CrossRefPubMed
2.
go back to reference Gibon GE, Goodman MJ, Goodman SB (2017) Patient satisfaction after total knee arthroplasty. Orthop Clin 48(4):421–431CrossRef Gibon GE, Goodman MJ, Goodman SB (2017) Patient satisfaction after total knee arthroplasty. Orthop Clin 48(4):421–431CrossRef
3.
go back to reference Dennis DA, Komistek RD, Hoff WA et al (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117CrossRef Dennis DA, Komistek RD, Hoff WA et al (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117CrossRef
4.
go back to reference Dennis D, Komistek R, Mahfouz M, Haas B, Stiehl J (2003) Conventry award paper: multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57CrossRef Dennis D, Komistek R, Mahfouz M, Haas B, Stiehl J (2003) Conventry award paper: multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57CrossRef
5.
go back to reference Dennis DA, Mahfouz MR, Komistek RD et al (2005) In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech 38(2):241–253CrossRefPubMed Dennis DA, Mahfouz MR, Komistek RD et al (2005) In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech 38(2):241–253CrossRefPubMed
6.
go back to reference Ginsel BL, Banks S, Verdonschot N et al (2009) Improving maximum flexion with a posterior cruciate retaining total knee arthroplasty: a fluoroscopic study. Acta Orthop Belg 75:801–807PubMed Ginsel BL, Banks S, Verdonschot N et al (2009) Improving maximum flexion with a posterior cruciate retaining total knee arthroplasty: a fluoroscopic study. Acta Orthop Belg 75:801–807PubMed
7.
go back to reference Grieco TF, Sharma A, Komistek RD, Cates HE (2016) Single versus multiple-radii cruciate-retaining total knee arthroplasty: an in-vivo mobile fluoroscopy study. J Arthroplasty 31:694–701CrossRefPubMed Grieco TF, Sharma A, Komistek RD, Cates HE (2016) Single versus multiple-radii cruciate-retaining total knee arthroplasty: an in-vivo mobile fluoroscopy study. J Arthroplasty 31:694–701CrossRefPubMed
8.
go back to reference Hoffman AA, Tkach TK, Evanich CJ et al (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRef Hoffman AA, Tkach TK, Evanich CJ et al (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRef
9.
go back to reference Incavo SJ, Mullins ER, Coughlin KM, Banks S, Banks A, Beynnon BD (2004) Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty. J Arthroplasty 19(7):906–910CrossRefPubMed Incavo SJ, Mullins ER, Coughlin KM, Banks S, Banks A, Beynnon BD (2004) Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty. J Arthroplasty 19(7):906–910CrossRefPubMed
10.
go back to reference Indelli PF, Marcucci M, Graceffa A, Charlton S, Latella L (2014) Primary posterior stabilized total knee arthroplasty: analysis of different instrumentation. J Orthop Surg Res 19(9):54–58CrossRef Indelli PF, Marcucci M, Graceffa A, Charlton S, Latella L (2014) Primary posterior stabilized total knee arthroplasty: analysis of different instrumentation. J Orthop Surg Res 19(9):54–58CrossRef
11.
go back to reference Indelli PF, Graceffa A, Payne B, Baldini A, Pipino G, Marcucci M (2015) Relationship between tibial baseplate design and rotational alignment landmarks in primary total knee arthroplasty. Arthritis 4:1–8CrossRef Indelli PF, Graceffa A, Payne B, Baldini A, Pipino G, Marcucci M (2015) Relationship between tibial baseplate design and rotational alignment landmarks in primary total knee arthroplasty. Arthritis 4:1–8CrossRef
12.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–24 Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–24
13.
go back to reference Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15(8) 970–973CrossRefPubMed Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15(8) 970–973CrossRefPubMed
14.
go back to reference Iwaki H, Pinskerova V, Freeman MAR (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82(8):1189–1195CrossRefPubMed Iwaki H, Pinskerova V, Freeman MAR (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82(8):1189–1195CrossRefPubMed
15.
go back to reference Joglekar S, Gioe TJ, Yoon P, Schwartz MH (2012) Gait analysis comparison of cruciate retaining and substituting TKA following PCL sacrifice. Knee 19(4):279–285CrossRefPubMed Joglekar S, Gioe TJ, Yoon P, Schwartz MH (2012) Gait analysis comparison of cruciate retaining and substituting TKA following PCL sacrifice. Knee 19(4):279–285CrossRefPubMed
16.
go back to reference Kleinbart FA, Bryk E, Evangelista J, Scott WN, Vigorita VJ (1996) Histologic comparison of posterior cruciate ligaments from arthritic and age-matched knee specimens. J Arthroplasty 11(6):726–731CrossRefPubMed Kleinbart FA, Bryk E, Evangelista J, Scott WN, Vigorita VJ (1996) Histologic comparison of posterior cruciate ligaments from arthritic and age-matched knee specimens. J Arthroplasty 11(6):726–731CrossRefPubMed
17.
go back to reference Komistek RD, Dennis DA, Mahfouz M (2003) In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res 410:69–81CrossRef Komistek RD, Dennis DA, Mahfouz M (2003) In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res 410:69–81CrossRef
18.
go back to reference Leszko F, Hovinga KR, Lerner AL et al (2011) In vivo normal knee kinematics: is ethnicity or gender an influencing factor? Clin Orthop Relat Res 469(1):95–106CrossRefPubMed Leszko F, Hovinga KR, Lerner AL et al (2011) In vivo normal knee kinematics: is ethnicity or gender an influencing factor? Clin Orthop Relat Res 469(1):95–106CrossRefPubMed
19.
go back to reference Li G, Zayontz S, DeFrate LE et al (2004) Kinematics of the knee at high flexion angles: an in vitro investigation. J Orthop Res 22(1):90–95CrossRefPubMed Li G, Zayontz S, DeFrate LE et al (2004) Kinematics of the knee at high flexion angles: an in vitro investigation. J Orthop Res 22(1):90–95CrossRefPubMed
20.
go back to reference Lombardi AV Jr., Mallory TH, Waterman RA, Eberle RW (1995) Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty. J Arthroplasty 10(5):643–650CrossRefPubMed Lombardi AV Jr., Mallory TH, Waterman RA, Eberle RW (1995) Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty. J Arthroplasty 10(5):643–650CrossRefPubMed
21.
go back to reference Lotke PA, Lonner JH (2009) Knee arthroplasty, 3rd edn. Wolters Kluwer Health/Lippincott Williams & Wilkins, Philadelphia Lotke PA, Lonner JH (2009) Knee arthroplasty, 3rd edn. Wolters Kluwer Health/Lippincott Williams & Wilkins, Philadelphia
22.
go back to reference Lützner J, Firmbach FP, Lützner C et al (2015) Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23(6):1638–1643CrossRefPubMed Lützner J, Firmbach FP, Lützner C et al (2015) Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23(6):1638–1643CrossRefPubMed
23.
go back to reference Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement restore normal knee function? Clin Orthop Relat Res 431:157–165CrossRef Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement restore normal knee function? Clin Orthop Relat Res 431:157–165CrossRef
24.
go back to reference Parcells BW, Tria AJ Jr (2016) The cruciate ligaments in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 45(4):153–160 Parcells BW, Tria AJ Jr (2016) The cruciate ligaments in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 45(4):153–160
25.
go back to reference Pope MH (2005) Giovanni Alfonso Borelli: the father of biomechanics. Spine 5(30):2350–2355CrossRef Pope MH (2005) Giovanni Alfonso Borelli: the father of biomechanics. Spine 5(30):2350–2355CrossRef
26.
go back to reference Rajgopal A, Aggarwal K, Khurana A, Rao A, Vasdev A, Pandit H (2017) Gait parameters and functional outcomes after total knee arthroplasty using persona knee system with cruciate retaining and ultracongruent knee inserts. J Arthroplasty 32(1):87–91CrossRefPubMed Rajgopal A, Aggarwal K, Khurana A, Rao A, Vasdev A, Pandit H (2017) Gait parameters and functional outcomes after total knee arthroplasty using persona knee system with cruciate retaining and ultracongruent knee inserts. J Arthroplasty 32(1):87–91CrossRefPubMed
28.
go back to reference Schulze A, Scharf HP (2013) Satisfaction after total knee arthroplasty. Comparison of 1990–1999 with 2000–2012. Orthopade 42(10):858–865CrossRefPubMed Schulze A, Scharf HP (2013) Satisfaction after total knee arthroplasty. Comparison of 1990–1999 with 2000–2012. Orthopade 42(10):858–865CrossRefPubMed
29.
go back to reference Steckelberg RC1, Funck N, Kim TE, Walters TL, Lochbaum GM, Memtsoudis SG, Giori NJ, Indelli PF, Mariano ER (2017) Adherence to a multimodal analgesic clinical pathway: a within-group comparison of staged bilateral knee arthroplasty patients. Reg Anesth Pain Med 42(3):368–371CrossRefPubMed Steckelberg RC1, Funck N, Kim TE, Walters TL, Lochbaum GM, Memtsoudis SG, Giori NJ, Indelli PF, Mariano ER (2017) Adherence to a multimodal analgesic clinical pathway: a within-group comparison of staged bilateral knee arthroplasty patients. Reg Anesth Pain Med 42(3):368–371CrossRefPubMed
30.
go back to reference Stiehl JB, Komistek RD, Dennis DA et al (1995) Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br 77(6):884–889CrossRefPubMed Stiehl JB, Komistek RD, Dennis DA et al (1995) Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br 77(6):884–889CrossRefPubMed
31.
go back to reference Scott G, Iman MA, Eifort A et al (2016) Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilized ? A pulsed fluoroscopic investigation. Bone Joint Res 5:80–86CrossRefPubMedPubMedCentral Scott G, Iman MA, Eifort A et al (2016) Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilized ? A pulsed fluoroscopic investigation. Bone Joint Res 5:80–86CrossRefPubMedPubMedCentral
32.
go back to reference Yoshiya S, Matsui N, Komistek RD et al (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplasty 20(6):777–783CrossRefPubMed Yoshiya S, Matsui N, Komistek RD et al (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplasty 20(6):777–783CrossRefPubMed
Metadata
Title
Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes
Authors
Pier Francesco Indelli
Salvatore Risitano
Kimberly E. Hall
Erika Leonardi
Eleonora Migliore
Publication date
01-04-2019
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2019
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-018-5170-5

Other articles of this Issue 4/2019

Knee Surgery, Sports Traumatology, Arthroscopy 4/2019 Go to the issue