Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2011

01-06-2011 | Knee

Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?

Authors: Sung-Do Cho, Yoon-Seok Youm, Ki-Bong Park

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2011

Login to get access

Abstract

Purpose

We evaluated 3- to 6-year clinical and radiological follow-up results after NexGen® LPS-flex total knee arthroplasty (TKA).

Methods

A retrospective evaluation was undertaken of 218 knees in 166 patients (22 males, 144 females) who were followed up for more than 3 years after TKA. Evaluations included preoperative and postoperative range of motion (ROM) measurement, Knee Society (KS) Score, tibiofemoral angle and assessment of postoperative complications.

Results

TKA resulted in a significant ROM increase from a mean flexion contracture of 9° (range 0°–20°) and further flexion of 117° (range 80°–155°) to a mean flexion contracture of 2° (range 0°–10°) and a further flexion of 131° (range 95°–155°). KS knee and function scores significantly improved from 52 and 38 before surgery to 87 and 82 after surgery, respectively. The tibiofemoral angle significantly improved from varus 5.7° to valgus 5.4°. Progressive radiolucent lines around the femoral component on radiographs were observed in 30 knees (13.8%, 27 patients), and more of those knees, could squat than non-radiolucent knees (76.7 vs. 20.2%; P < 0.05). Seven knees (3.2%, 6 patients) were revised at a mean 49 months after the index operation.

Conclusions

While NexGen® LPS-flex TKA satisfactorily improved ROM, it was associated with a relatively high incidence of early loosening of the femoral components. This might be associated with passive-maximal flexion activity, such as squatting or kneeling. The clinical relevance of this study is that squatting or kneeling, common activity in Asian, may not be allowed after NexGen® LPS-flex TKA.
Literature
1.
go back to reference Anouchi YS, McShane M, Kelly F Jr, Elting J, Stiehl J (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92PubMedCrossRef Anouchi YS, McShane M, Kelly F Jr, Elting J, Stiehl J (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92PubMedCrossRef
2.
go back to reference Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138PubMedCrossRef Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138PubMedCrossRef
3.
go back to reference Bin SI, Nam TS (2007) Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 15:350–355PubMedCrossRef Bin SI, Nam TS (2007) Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 15:350–355PubMedCrossRef
4.
go back to reference Chew JT, Stewart NJ, Hanssen AD, Luo ZP, Rand JA, An KN (1997) Differences in patellar tracking and knee kinematics among three different total knee designs. Clin Orthop Relat Res 345:87–98PubMedCrossRef Chew JT, Stewart NJ, Hanssen AD, Luo ZP, Rand JA, An KN (1997) Differences in patellar tracking and knee kinematics among three different total knee designs. Clin Orthop Relat Res 345:87–98PubMedCrossRef
5.
go back to reference Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN (1998) Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752PubMedCrossRef Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN (1998) Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752PubMedCrossRef
6.
go back to reference D’Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell CW Jr (2008) In vivo contact stresses during activities of daily living after knee arthroplasty. J Orthop Res 26:1549–1555PubMedCrossRef D’Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell CW Jr (2008) In vivo contact stresses during activities of daily living after knee arthroplasty. J Orthop Res 26:1549–1555PubMedCrossRef
7.
go back to reference Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461PubMedCrossRef Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461PubMedCrossRef
8.
go back to reference Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20:674–679PubMedCrossRef Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20:674–679PubMedCrossRef
9.
go back to reference Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis. A report of two hundred and twenty cases. J Bone Joint Surg Am 61:173–180PubMed Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis. A report of two hundred and twenty cases. J Bone Joint Surg Am 61:173–180PubMed
10.
go back to reference Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 90:1304–1310PubMedCrossRef Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 90:1304–1310PubMedCrossRef
11.
go back to reference Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef
12.
go back to reference Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prosthesis. A prospective, randomized study. J Bone Joint Surg Am 87:1470–1475PubMedCrossRef Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prosthesis. A prospective, randomized study. J Bone Joint Surg Am 87:1470–1475PubMedCrossRef
13.
go back to reference King TV, Scott RD (1985) Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res 194:285–290PubMed King TV, Scott RD (1985) Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res 194:285–290PubMed
14.
go back to reference Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T (2002) Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty 17:59–62PubMedCrossRef Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T (2002) Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty 17:59–62PubMedCrossRef
15.
16.
go back to reference Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198PubMedCrossRef Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24:191–198PubMedCrossRef
17.
go back to reference Nagura T, Dyrby CO, Alexander EJ, Andriacchi TP (2002) Mechanical loads at the knee joint during deep flexion. J Orthop Res 20:881–886PubMedCrossRef Nagura T, Dyrby CO, Alexander EJ, Andriacchi TP (2002) Mechanical loads at the knee joint during deep flexion. J Orthop Res 20:881–886PubMedCrossRef
18.
go back to reference Nakayama K, Matsuda S, Miura H, Iwamoto Y, Higaki H, Otsuka K (2005) Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. J Bone Joint Surg Br 87:483–488PubMed Nakayama K, Matsuda S, Miura H, Iwamoto Y, Higaki H, Otsuka K (2005) Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. J Bone Joint Surg Br 87:483–488PubMed
19.
go back to reference Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop Relat Res 461:143–152PubMed Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop Relat Res 461:143–152PubMed
20.
go back to reference Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 2:95–97PubMedCrossRef Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 2:95–97PubMedCrossRef
21.
go back to reference Thambyah A, Goh JC, De SD (2005) Contact stresses in the knee joint in deep flexion. Med Eng Phys 27:329–335PubMedCrossRef Thambyah A, Goh JC, De SD (2005) Contact stresses in the knee joint in deep flexion. Med Eng Phys 27:329–335PubMedCrossRef
Metadata
Title
Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?
Authors
Sung-Do Cho
Yoon-Seok Youm
Ki-Bong Park
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1218-x

Other articles of this Issue 6/2011

Knee Surgery, Sports Traumatology, Arthroscopy 6/2011 Go to the issue