Skip to main content
Top
Published in: International Orthopaedics 9/2011

01-09-2011 | Original Paper

High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up

Authors: Aree Tanavalee, Srihatach Ngarmukos, Saran Tantavisut, Arak Limtrakul

Published in: International Orthopaedics | Issue 9/2011

Login to get access

Abstract

We prospectively evaluated outcomes of high-flexion total knee arthroplasty in 165 patients who had advanced arthritis with a minimum 120-degree pre-operative knee flexion, with a mean follow-up of 77 months. Patients were divided into two groups according to their ability to perform full-range (heel-to-buttock) pre-operative knee flexion (group A) and the inability to do so (group B). The overall clinical rating was “excellent” in 96% of patients and “good” in 4% of patients. Mean maximum knee flexion decreased from 137.9° to 134.8°, with no statistical difference between pre- and post-operative knee flexion. However, patients in group A had significantly decreased knee flexion (146.2° vs. 135.0°, p < 0.001), whereas patients in group B exhibited no change in knee flexion (133.7° vs. 134.7°, p = 0.14). We found that 14.7%, 36.5% and 43.0% of the studied patients could engage in kneeling, Thai polite style sitting and cross-legged sitting, respectively, with no significant differences between groups A and B. The survival rates for any reoperation and prosthesis-related problem (such as early loosening) at six years were 98.3% and 100%, respectively. At six-year follow-up in patients with well preserved pre-operative knee flexion, the high-flexion knee prosthesis provided a favourable outcome without improving knee flexion.
Literature
1.
go back to reference Zhang Y, Hunter DJ, Nevitt MC, Xu L, Niu J, Lui LY et al (2004) Association of squatting with increased prevalence of radiographic tibiofemoral knee osteoarthritis: the Beijing Osteoarthritis Study. Arthritis Rheum 50:1187–1192PubMedCrossRef Zhang Y, Hunter DJ, Nevitt MC, Xu L, Niu J, Lui LY et al (2004) Association of squatting with increased prevalence of radiographic tibiofemoral knee osteoarthritis: the Beijing Osteoarthritis Study. Arthritis Rheum 50:1187–1192PubMedCrossRef
2.
go back to reference Lingard EA, Sledge CB, Learmonth ID (2006) Patient expectations regarding total knee arthroplasty: differences among the United States, United Kingdom, and Australia. J Bone Jt Surg Am 88-A:1201–1207CrossRef Lingard EA, Sledge CB, Learmonth ID (2006) Patient expectations regarding total knee arthroplasty: differences among the United States, United Kingdom, and Australia. J Bone Jt Surg Am 88-A:1201–1207CrossRef
3.
go back to reference Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop 461:143–152PubMed Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop 461:143–152PubMed
4.
go back to reference Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef
5.
go back to reference Sultan PG, Most E, Schule S, Li G, Rubash HE (2003) Optimizing flexion after total knee arthroplasty: advances in prosthetic design. Clin Orthop 416:167–173PubMedCrossRef Sultan PG, Most E, Schule S, Li G, Rubash HE (2003) Optimizing flexion after total knee arthroplasty: advances in prosthetic design. Clin Orthop 416:167–173PubMedCrossRef
6.
go back to reference Argenson JN, Komistek RD, Mahfouz M, Walker SA, Aubaniac JM, Dennis DA (2004) A high flexion total knee arthroplasty design replicates healthy knee motion. Clin Orthop 428:174–179PubMedCrossRef Argenson JN, Komistek RD, Mahfouz M, Walker SA, Aubaniac JM, Dennis DA (2004) A high flexion total knee arthroplasty design replicates healthy knee motion. Clin Orthop 428:174–179PubMedCrossRef
7.
go back to reference Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20:674–679PubMedCrossRef Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20:674–679PubMedCrossRef
8.
go back to reference Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Jt Surg Br 90-B:1304–1310CrossRef Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Jt Surg Br 90-B:1304–1310CrossRef
9.
go back to reference Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Jt Surg Am 87-A:1470–1475CrossRef Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Jt Surg Am 87-A:1470–1475CrossRef
10.
go back to reference Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA (2008) A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Jt Surg Br 90-B:37–42CrossRef Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA (2008) A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Jt Surg Br 90-B:37–42CrossRef
11.
go back to reference Kim YH, Choi Y, Kwon OR, Kim JS (2009) Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Jt Surg Am 91-A:753–760CrossRef Kim YH, Choi Y, Kwon OR, Kim JS (2009) Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Jt Surg Am 91-A:753–760CrossRef
12.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed
13.
go back to reference Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89-B:1457–1461CrossRef Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Jt Surg Br 89-B:1457–1461CrossRef
14.
go back to reference Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK (2009) Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs. J Bone Jt Surg Am 91-A:672–679CrossRef Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK (2009) Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs. J Bone Jt Surg Am 91-A:672–679CrossRef
15.
go back to reference Moynihan AL, Varadarajan KM, Hanson GR, Park SE, Nha KW, Suggs JF et al (2010) In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty. Int Orthop 34:497–503PubMedCrossRef Moynihan AL, Varadarajan KM, Hanson GR, Park SE, Nha KW, Suggs JF et al (2010) In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty. Int Orthop 34:497–503PubMedCrossRef
16.
go back to reference Hamusch B, Lou TN, Warriner G, Hui A, Gregg P (2010) Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trial. Int Orthop 34:349–354CrossRef Hamusch B, Lou TN, Warriner G, Hui A, Gregg P (2010) Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trial. Int Orthop 34:349–354CrossRef
17.
go back to reference Tsuji S, Tomita T, Hashimoto H, Fujii M, Yoshikawa H, Sugamoto K (2010) Effect of posterior design changes on postoperative flexion angle in cruciate retaining mobile-bearing total knee arthroplasty. Int Orthop. doi:10.1007/s00264-010-1060-2 PubMed Tsuji S, Tomita T, Hashimoto H, Fujii M, Yoshikawa H, Sugamoto K (2010) Effect of posterior design changes on postoperative flexion angle in cruciate retaining mobile-bearing total knee arthroplasty. Int Orthop. doi:10.​1007/​s00264-010-1060-2 PubMed
18.
go back to reference Murphy M, Journeaux S, Russell T (2009) High-flexion total knee arthroplasty: a systematic review. Int Orthop 33:887–893PubMedCrossRef Murphy M, Journeaux S, Russell T (2009) High-flexion total knee arthroplasty: a systematic review. Int Orthop 33:887–893PubMedCrossRef
19.
go back to reference Huddleston JI, Scarborough DM, Goldvasser D, Freiberg AA, Malchau H (2009) 2009 Marshall Urist Young Investigator Award: how often do patients with high-flex total knee arthroplasty use high flexion? Clin Orthop 467:1898–1906PubMedCrossRef Huddleston JI, Scarborough DM, Goldvasser D, Freiberg AA, Malchau H (2009) 2009 Marshall Urist Young Investigator Award: how often do patients with high-flex total knee arthroplasty use high flexion? Clin Orthop 467:1898–1906PubMedCrossRef
Metadata
Title
High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up
Authors
Aree Tanavalee
Srihatach Ngarmukos
Saran Tantavisut
Arak Limtrakul
Publication date
01-09-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 9/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1140-3

Other articles of this Issue 9/2011

International Orthopaedics 9/2011 Go to the issue