Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2016

Open Access 01-12-2016 | Research article

Total knee arthroplasty using NexGen LPS-flex® improves clinical outcomes without early loosening: minimum 6-year follow-up results

Authors: Yoon Sang Jeon, Joong Sup Shin, Jae Ho Jung, Myung Ku Kim

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2016

Login to get access

Abstract

Background

The authors analyzed clinical and radiological 6-year follow-up results after total knee arthroplasty (TKA) with NexGen LPS-flex® and implant survivorship.

Methods

The medical records of 80 patients that underwent 122 TKAs using NexGen LPS-flex® from February 2005 to November 2008 and followed up for at least 6 years were reviewed. The Internal Knee Documentation Committee (IKDC) subjective form, Western Ontario and McMaster Universities Arthritis Index (WOMAC), and Knee Injury and Osteoarthritis Outcome Score (KOOS) scores and preoperative and postoperative ranges of motion (ROMs) were recorded. Radiological assessments were performed by simple radiography preoperatively, immediately postoperatively, and at the final follow-up.

Results

At the last follow-up visits, average ROM improved from 115.0° (80°–135°) to 131.76° (80°–150°), average IKDC subjective score from 30.54 (13–48) to 53.53 (31–80), average WOMAC score from 59.81 (35–90) to 15.98 (1–47), and average KOOS score from 75.33 (38–115) to 115.0 (52–174). The clinical results of 66 knees that had >130° of postoperative flexion and 56 knees that had <130 of postoperative flexion were compared. Radiolucent lines were found in 7 knees in those with a flexion angle of >130° and in 6 knees in those with a flexion angle of <130°, but the lines did not progress and meaningful loosening was not observed. Similarly, the occurrences of radiolucent lines in those with a flexion angle of >130° or <130° were not significantly different (p > 0.05).

Conclusions

TKA with NexGen LPS-flex® showed satisfactory clinical improvements, including high flexion, and no early loosening was found at 6-year follow-up visits.
Literature
1.
go back to reference Cross MJ, Parish EN. A hydroxyapatite-coated total knee replacement: prospective analysis of 1000 patients. J Bone Joint Surg Br. 2005;87:1073–6.CrossRefPubMed Cross MJ, Parish EN. A hydroxyapatite-coated total knee replacement: prospective analysis of 1000 patients. J Bone Joint Surg Br. 2005;87:1073–6.CrossRefPubMed
2.
go back to reference Epinette JA, Manley MT. Hydroxyapatite-coated total knee replacement: clinical experience at 10 to 15 years. J Bone Joint Surg Br. 2007;89:34–8.CrossRefPubMed Epinette JA, Manley MT. Hydroxyapatite-coated total knee replacement: clinical experience at 10 to 15 years. J Bone Joint Surg Br. 2007;89:34–8.CrossRefPubMed
3.
go back to reference Oliver MC, Keast-Butler OD, Hinves BL, Shepperd JA. A hydroxyapatite- coated Insall-Burstein II total knee replacement: 11-year results. J Bone Joint Surg Br. 2005;87:478–82.CrossRefPubMed Oliver MC, Keast-Butler OD, Hinves BL, Shepperd JA. A hydroxyapatite- coated Insall-Burstein II total knee replacement: 11-year results. J Bone Joint Surg Br. 2005;87:478–82.CrossRefPubMed
4.
go back to reference Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res. 2003;410:131–8.CrossRefPubMed Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res. 2003;410:131–8.CrossRefPubMed
5.
go back to reference Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T. Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty. 2002;17(4 Suppl 1):59–62.CrossRefPubMed Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T. Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty. 2002;17(4 Suppl 1):59–62.CrossRefPubMed
6.
go back to reference Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15:350–5.CrossRefPubMed Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15:350–5.CrossRefPubMed
7.
go back to reference Moon KH, Lee DJ, Lee JS, Kim YT. Total knee replacement arthroplasty with NexGen®-LPS: minimum 5 year follow-up results. J Korean Orthop Assoc. 2011;46:405–11.CrossRef Moon KH, Lee DJ, Lee JS, Kim YT. Total knee replacement arthroplasty with NexGen®-LPS: minimum 5 year follow-up results. J Korean Orthop Assoc. 2011;46:405–11.CrossRef
8.
go back to reference Kim TH, Lee DH, Bin SI. The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br. 2008;90:1304–10.CrossRefPubMed Kim TH, Lee DH, Bin SI. The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br. 2008;90:1304–10.CrossRefPubMed
9.
go back to reference Lee BS, Kim JM, Lee SJ, Jung KH, Lee DH, Cha EJ, Bin SI. High-flexion total knee arthroplasty improves flexion of stiff knees. Knee Surg Sports Traumatol Arthrosc. 2011;19:936–42.CrossRefPubMed Lee BS, Kim JM, Lee SJ, Jung KH, Lee DH, Cha EJ, Bin SI. High-flexion total knee arthroplasty improves flexion of stiff knees. Knee Surg Sports Traumatol Arthrosc. 2011;19:936–42.CrossRefPubMed
10.
go back to reference Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005;87:1470–5.CrossRefPubMed Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005;87:1470–5.CrossRefPubMed
11.
go back to reference Lee BS, Chung JW, Kim JM, Kim KA, Bin SIMD. High-flexion prosthesis improves function of TKA in Asian patients without decreasing early survivorship. Clin Orthop Relat Res. 2013;471:1504–11.CrossRefPubMed Lee BS, Chung JW, Kim JM, Kim KA, Bin SIMD. High-flexion prosthesis improves function of TKA in Asian patients without decreasing early survivorship. Clin Orthop Relat Res. 2013;471:1504–11.CrossRefPubMed
12.
go back to reference Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Joint Surg Br. 2008;90:37–42.CrossRefPubMed Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Joint Surg Br. 2008;90:37–42.CrossRefPubMed
13.
go back to reference Han HS, Kang SB, Yoon KS. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br. 2007;89:1457–61.CrossRefPubMed Han HS, Kang SB, Yoon KS. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br. 2007;89:1457–61.CrossRefPubMed
14.
go back to reference Cho SD, Youm YS, Park KB. Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc. 2011;19:899–903.CrossRefPubMed Cho SD, Youm YS, Park KB. Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc. 2011;19:899–903.CrossRefPubMed
15.
go back to reference Choi YJ, Kang JH, Lee KW, Joo YS, Park JS, Choo HH. Early aseptic loosening after total knee replacement using legacy posterior stabilized-flex prosthesis. J Korean Orthop Assoc. 2012;47:35–40.CrossRef Choi YJ, Kang JH, Lee KW, Joo YS, Park JS, Choo HH. Early aseptic loosening after total knee replacement using legacy posterior stabilized-flex prosthesis. J Korean Orthop Assoc. 2012;47:35–40.CrossRef
16.
go back to reference Nieuwenhuijse MJ, van der Voort P, Kaptein BL, van der Linden-van der Zwaag HM, Valstar ER, Nelissen RG. Fixation of high-flexion total knee prostheses: five-year follow-up results of a four-arm randomized controlled clinical and roentgen stereophotogrammetric analysis study. J Bone Joint Surg Am. 2013;95(19):e141.CrossRef Nieuwenhuijse MJ, van der Voort P, Kaptein BL, van der Linden-van der Zwaag HM, Valstar ER, Nelissen RG. Fixation of high-flexion total knee prostheses: five-year follow-up results of a four-arm randomized controlled clinical and roentgen stereophotogrammetric analysis study. J Bone Joint Surg Am. 2013;95(19):e141.CrossRef
17.
go back to reference Kim YH, Park JW, Kim JS. High-flexion total knee arthroplasty: survivorship and prevalence of osteolysis: results after a minimum of ten years of follow-up. J Bone Joint Surg Am. 2012;94:1378–84.CrossRefPubMed Kim YH, Park JW, Kim JS. High-flexion total knee arthroplasty: survivorship and prevalence of osteolysis: results after a minimum of ten years of follow-up. J Bone Joint Surg Am. 2012;94:1378–84.CrossRefPubMed
18.
go back to reference Rhee SJ, Hong SM, Suh JT. High-flexion total knee arthroplasty using NexGen LPS-flex system: minimum 5-year follow-up results. Knee Surg Relat Res. 2015;27(3):156–62.CrossRefPubMedPubMedCentral Rhee SJ, Hong SM, Suh JT. High-flexion total knee arthroplasty using NexGen LPS-flex system: minimum 5-year follow-up results. Knee Surg Relat Res. 2015;27(3):156–62.CrossRefPubMedPubMedCentral
Metadata
Title
Total knee arthroplasty using NexGen LPS-flex® improves clinical outcomes without early loosening: minimum 6-year follow-up results
Authors
Yoon Sang Jeon
Joong Sup Shin
Jae Ho Jung
Myung Ku Kim
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2016
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-016-0419-5

Other articles of this Issue 1/2016

Journal of Orthopaedic Surgery and Research 1/2016 Go to the issue