Skip to main content
Top
Published in: Medical Oncology 4/2017

01-04-2017 | Original Paper

Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety

Authors: Chiara Floridi, Alfonso Reginelli, Raffaella Capasso, Enrico Fumarola, Filippo Pesapane, Antonio Barile, Marcello Zappia, Ferdinando Caranci, Luca Brunese

Published in: Medical Oncology | Issue 4/2017

Login to get access

Abstract

The aim of this study is to evaluate the feasibility of percutaneous needle biopsy of mediastinal masses under conebeam computed tomography (CBCT) and “XperGuide” navigation guidance. From September 2013 to April 2016, 40 patients (25 men and 15 women; mean age 52.5 years; range 18.7–86.4 years) with 40 mediastinal masses underwent CBCT-/”XperGuide”-guided percutaneous needle biopsies. Technical success, sensibility, specificity, positive predictive value (ppv), negative predictive value (npv) and complications rate were evaluated. Technical success evaluated as the correct positioning of the needle inside the lesion was 100%. Based on histopathological diagnosis, 2 of 40 biopsies (5%) resulted a false negative. Diagnostic accuracy was 95%, sensitivity was 95%, specificity was 100%, ppv was 100%, and npv was 33%. The mean total procedure time was 32 min (range 15–60 min) revealing a reduction in time comparing the first group of 20 patients (mean time 45 min) with the last group of 20 patients (mean time 17 min). No major complications were recorded. Only three patients (7.5%) had mild pneumothorax as demonstrated by post-procedural CBCT, resolved spontaneously. CBCT/“XperGuide” navigation system is a new, safe and accurate technique that can be used as guidance for mediastinal mass biopsies. It also permits the use of CT machines for diagnostic examinations relieving them from interventional procedures burden.
Literature
1.
go back to reference Aroor AR, Prakasha RS, Seshadri S, Teerthanath S, Raghuraj U. A study of clinical characteristics of mediastinal mass. J Clin Diagn Res. 2014;8(2):77–80.PubMedPubMedCentral Aroor AR, Prakasha RS, Seshadri S, Teerthanath S, Raghuraj U. A study of clinical characteristics of mediastinal mass. J Clin Diagn Res. 2014;8(2):77–80.PubMedPubMedCentral
2.
go back to reference Ching CO, Lynette LST. Imaging of anterior mediastinal tumours. Cancer Imaging. 2012;12:506–15.CrossRef Ching CO, Lynette LST. Imaging of anterior mediastinal tumours. Cancer Imaging. 2012;12:506–15.CrossRef
3.
go back to reference Reginelli A, Rossi C, Capasso R, Urraro F, Cagini L, Di Crescenzo V, et al. Evaluation with multislice CT of the hilar pulmonary nodules for probable infiltration of vascular-bronchial structures. Recenti Prog Med. 2013;104:403–5.PubMed Reginelli A, Rossi C, Capasso R, Urraro F, Cagini L, Di Crescenzo V, et al. Evaluation with multislice CT of the hilar pulmonary nodules for probable infiltration of vascular-bronchial structures. Recenti Prog Med. 2013;104:403–5.PubMed
4.
go back to reference Brunese L, Greco B, Setola FR, Lassandro F, Guarracino MR, De Rimini M, et al. Non-small cell lung cancer evaluated with quantitative contrast-enhanced CT and PET-CT: net enhancement and standardized uptake values are related to tumour size and histology. Med Sci Monit. 2013;7(19):95–101.CrossRef Brunese L, Greco B, Setola FR, Lassandro F, Guarracino MR, De Rimini M, et al. Non-small cell lung cancer evaluated with quantitative contrast-enhanced CT and PET-CT: net enhancement and standardized uptake values are related to tumour size and histology. Med Sci Monit. 2013;7(19):95–101.CrossRef
5.
go back to reference Gupta S, Seaberg K, Wallace M. Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic consideration. Radiographics. 2005;25(3):763–86.CrossRefPubMed Gupta S, Seaberg K, Wallace M. Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic consideration. Radiographics. 2005;25(3):763–86.CrossRefPubMed
6.
go back to reference De Filippo M, Saba L, Silva M, Zagaria R, Concari G, Nizzoli R, et al. CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? Diagn Interv Radiol. 2014;20(5):421–5.CrossRefPubMedPubMedCentral De Filippo M, Saba L, Silva M, Zagaria R, Concari G, Nizzoli R, et al. CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? Diagn Interv Radiol. 2014;20(5):421–5.CrossRefPubMedPubMedCentral
7.
go back to reference De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118(7):1071–81.CrossRefPubMed De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118(7):1071–81.CrossRefPubMed
8.
go back to reference Lu Y, Fritz J, Li C, Liu M, Lee P, Wu L, Carrino JA. Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses. Diagnostic performance and safety. Invest Radiol. 2013;48(6):452–7.CrossRefPubMed Lu Y, Fritz J, Li C, Liu M, Lee P, Wu L, Carrino JA. Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses. Diagnostic performance and safety. Invest Radiol. 2013;48(6):452–7.CrossRefPubMed
9.
go back to reference Braak SJ, Van Strjen MJL, Van Leersum M, Van Es HW, Van Heesewijk JPM. Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy and feasibility. AJR Am J Roentgenol. 2010;194(5):W445–51.CrossRefPubMed Braak SJ, Van Strjen MJL, Van Leersum M, Van Es HW, Van Heesewijk JPM. Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy and feasibility. AJR Am J Roentgenol. 2010;194(5):W445–51.CrossRefPubMed
10.
go back to reference Floridi C, Muollo A, Fontana F, et al. C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules. Radiol Med. 2014;119(11):820–7.CrossRefPubMed Floridi C, Muollo A, Fontana F, et al. C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules. Radiol Med. 2014;119(11):820–7.CrossRefPubMed
11.
go back to reference Carrafiello G, Fontana F, Mangini M, Ierardi AM, Cotta E, Floridi C, Piacentino F, Fugazzola C. Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med. 2012;117:1386–97.CrossRefPubMed Carrafiello G, Fontana F, Mangini M, Ierardi AM, Cotta E, Floridi C, Piacentino F, Fugazzola C. Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med. 2012;117:1386–97.CrossRefPubMed
12.
go back to reference Busser WMH, Hoogeveen YL, Veth RPH, Schreuder HWB, Balguid A, Renema WK, Schultzekool LJ. Percutaneous radiofrequency ablation of osteoid osteomas with use of real-time needle guidance for accurate needle placement: a pilot study. Cardiovasc Intervent Radiol. 2011;34:180–3.CrossRefPubMed Busser WMH, Hoogeveen YL, Veth RPH, Schreuder HWB, Balguid A, Renema WK, Schultzekool LJ. Percutaneous radiofrequency ablation of osteoid osteomas with use of real-time needle guidance for accurate needle placement: a pilot study. Cardiovasc Intervent Radiol. 2011;34:180–3.CrossRefPubMed
13.
go back to reference Cardella JF, Kundu S, Miller DL. Society of interventional radiology clinical practice guidelines. J Vasc Interv Radiol. 2009;20(7 Suppl):S189–91.CrossRefPubMed Cardella JF, Kundu S, Miller DL. Society of interventional radiology clinical practice guidelines. J Vasc Interv Radiol. 2009;20(7 Suppl):S189–91.CrossRefPubMed
14.
go back to reference Racadio JM, Babic D, Homan R, Rampton JW, Patel MN, Racadio JM, Johnson ND. Live 3D guidance in the interventional radiology suite. AJR. 2007;189:W357–64.CrossRefPubMed Racadio JM, Babic D, Homan R, Rampton JW, Patel MN, Racadio JM, Johnson ND. Live 3D guidance in the interventional radiology suite. AJR. 2007;189:W357–64.CrossRefPubMed
15.
go back to reference Braak SJ, Van Melick HHE, Onaca MG, Van Heesewijk JPM, Van Strijen MJL. 3D cone-beam CT guidance, a novel technique in renal biopsy-results in 41 patients with suspected renal masses. Eur Radiol. 2012;22:2547–52.CrossRefPubMedPubMedCentral Braak SJ, Van Melick HHE, Onaca MG, Van Heesewijk JPM, Van Strijen MJL. 3D cone-beam CT guidance, a novel technique in renal biopsy-results in 41 patients with suspected renal masses. Eur Radiol. 2012;22:2547–52.CrossRefPubMedPubMedCentral
16.
go back to reference Floridi C, Radaelli A, Abi-Jaoudeh N, Grass M, De Lin M, Chiaradia M, Geschwind JF, Kobeiter H, Squillaci E, Maleux G, Giovagnoni A, Brunese L, Wood B, Carrafiello G, Rotondo A. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications. Radiol Med. 2014;119:521–32.CrossRefPubMedPubMedCentral Floridi C, Radaelli A, Abi-Jaoudeh N, Grass M, De Lin M, Chiaradia M, Geschwind JF, Kobeiter H, Squillaci E, Maleux G, Giovagnoni A, Brunese L, Wood B, Carrafiello G, Rotondo A. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications. Radiol Med. 2014;119:521–32.CrossRefPubMedPubMedCentral
17.
go back to reference Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology. 2014;271(1):291–300.CrossRefPubMed Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology. 2014;271(1):291–300.CrossRefPubMed
18.
go back to reference Braak SJ, Herder GJM, Van Heesewijk JPM, Van Strijen MJL. Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol. 2012;35:1414–21.CrossRefPubMed Braak SJ, Herder GJM, Van Heesewijk JPM, Van Strijen MJL. Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol. 2012;35:1414–21.CrossRefPubMed
19.
go back to reference Kim H, Park CM, Lee SM, Goo JM. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: diagnostic accuracy and complications. Eur Radiol. 2015;25(12):3508–17.CrossRefPubMed Kim H, Park CM, Lee SM, Goo JM. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: diagnostic accuracy and complications. Eur Radiol. 2015;25(12):3508–17.CrossRefPubMed
20.
go back to reference Abi-Jaoudeh N, Kruecker J, Kadoury S, Kobeiter H, Venkatesan A, Levy E, Wood BJ. Multimodality image fusion guided procedures: technique, accuracy, and applications. Cardiovasc Intervent Radiol. 2012;35(5):986–98.CrossRefPubMedPubMedCentral Abi-Jaoudeh N, Kruecker J, Kadoury S, Kobeiter H, Venkatesan A, Levy E, Wood BJ. Multimodality image fusion guided procedures: technique, accuracy, and applications. Cardiovasc Intervent Radiol. 2012;35(5):986–98.CrossRefPubMedPubMedCentral
21.
go back to reference Rotolo N, Floridi C, Imperatori A, Fontana F, Ierardi AM, Mangini M, Arlant V, De Marchi G, Novario R, Dominioni L, Fugazzola C, Carrafiello G. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol. 2016;26(2):381–9.CrossRefPubMed Rotolo N, Floridi C, Imperatori A, Fontana F, Ierardi AM, Mangini M, Arlant V, De Marchi G, Novario R, Dominioni L, Fugazzola C, Carrafiello G. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol. 2016;26(2):381–9.CrossRefPubMed
Metadata
Title
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
Authors
Chiara Floridi
Alfonso Reginelli
Raffaella Capasso
Enrico Fumarola
Filippo Pesapane
Antonio Barile
Marcello Zappia
Ferdinando Caranci
Luca Brunese
Publication date
01-04-2017
Publisher
Springer US
Published in
Medical Oncology / Issue 4/2017
Print ISSN: 1357-0560
Electronic ISSN: 1559-131X
DOI
https://doi.org/10.1007/s12032-017-0911-8

Other articles of this Issue 4/2017

Medical Oncology 4/2017 Go to the issue