Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 6/2012

01-12-2012 | Clinical Investigation

Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

Authors: Sicco J. Braak, Gerarda J. M. Herder, Johannes P. M. van Heesewijk, Marco J. L. van Strijen

Published in: CardioVascular and Interventional Radiology | Issue 6/2012

Login to get access

Abstract

Purpose

To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques.

Methods

CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator).

Results

Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm−2, and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications.

Conclusion

CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.
Literature
1.
go back to reference Herth FJF, Eberhardt R, Ernst A (2006) The future of bronchoscopy in diagnosing, staging and treatment of lung cancer. Respiratory 73:399–409 Herth FJF, Eberhardt R, Ernst A (2006) The future of bronchoscopy in diagnosing, staging and treatment of lung cancer. Respiratory 73:399–409
2.
go back to reference Sheth S, Harper UH, Stanley DB et al (1999) US guidance for thoracic biopsy: a valuable alternative to CT. Radiology 210:721–726PubMed Sheth S, Harper UH, Stanley DB et al (1999) US guidance for thoracic biopsy: a valuable alternative to CT. Radiology 210:721–726PubMed
3.
go back to reference Diacon AH, Theron J, Shubert P et al (2007) Ultrasound-assisted transthoracic biopsy: fine needle aspiration or cutting-needle biopsy? Eur Respir J 29:357–362PubMedCrossRef Diacon AH, Theron J, Shubert P et al (2007) Ultrasound-assisted transthoracic biopsy: fine needle aspiration or cutting-needle biopsy? Eur Respir J 29:357–362PubMedCrossRef
4.
go back to reference Heck SL, Blom P, Berstad A (2006) Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses. Eur Radiol 16:1387–1392PubMedCrossRef Heck SL, Blom P, Berstad A (2006) Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses. Eur Radiol 16:1387–1392PubMedCrossRef
5.
go back to reference Hiraki T, Mimura H, Gobara H et al (2009) CT fluoroscopy-guided biopsy of 1, 000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 136:1612–1617PubMedCrossRef Hiraki T, Mimura H, Gobara H et al (2009) CT fluoroscopy-guided biopsy of 1, 000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 136:1612–1617PubMedCrossRef
6.
go back to reference Cham MD, Lane ME, Henschke CI et al (2008) Lung biopsy: special techniques. Semin Respir Crit Care Med 29:335–349PubMedCrossRef Cham MD, Lane ME, Henschke CI et al (2008) Lung biopsy: special techniques. Semin Respir Crit Care Med 29:335–349PubMedCrossRef
7.
go back to reference Braak SJ, van Strijen MJL, van Leersum M et al (2010) Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility. AJR Am J Roentgenol 194:W445–W451PubMedCrossRef Braak SJ, van Strijen MJL, van Leersum M et al (2010) Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility. AJR Am J Roentgenol 194:W445–W451PubMedCrossRef
8.
go back to reference Gupta S, Wallace MJ, Cardella JF et al (2010) Quality improvement guidelines for percutaneous needle biopsy. J Vasc Interv Radiol 21:969–975PubMedCrossRef Gupta S, Wallace MJ, Cardella JF et al (2010) Quality improvement guidelines for percutaneous needle biopsy. J Vasc Interv Radiol 21:969–975PubMedCrossRef
9.
go back to reference Duncan M, Wijesekera N, Padley S (2010) Interventional radiology of the thorax. Respirology 15:401–412PubMedCrossRef Duncan M, Wijesekera N, Padley S (2010) Interventional radiology of the thorax. Respirology 15:401–412PubMedCrossRef
10.
go back to reference Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115PubMedCrossRef Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115PubMedCrossRef
11.
go back to reference Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708PubMedCrossRef Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708PubMedCrossRef
12.
go back to reference Schaefer PJ, Schaefer FKW, Heller M et al (2007) CT fluoroscopy-guided biopsy of small pulmonary and upper abdominal lesions: efficacy with a modified breathing technique. J Vasc Interv Radiol 18:1241–1248PubMedCrossRef Schaefer PJ, Schaefer FKW, Heller M et al (2007) CT fluoroscopy-guided biopsy of small pulmonary and upper abdominal lesions: efficacy with a modified breathing technique. J Vasc Interv Radiol 18:1241–1248PubMedCrossRef
13.
go back to reference Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239PubMedCrossRef Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239PubMedCrossRef
14.
go back to reference Tsukada H, Satou T, Iwashima A et al (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMed Tsukada H, Satou T, Iwashima A et al (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMed
15.
go back to reference Betsou S, Efstathopoulos EP, Katritsis D et al (1998) Patiënt radiation doses during cardiac catheterization procedures. Br J Radiol 71:634–639PubMed Betsou S, Efstathopoulos EP, Katritsis D et al (1998) Patiënt radiation doses during cardiac catheterization procedures. Br J Radiol 71:634–639PubMed
16.
go back to reference Yamagami T, Kato T, Hiroto T et al (2006) Usefulness and limitation of manual aspiration immediately after pneumothorax complication interventional radiological procedures with the transthoracic approach. Cardiovasc Intervent Radiol 29:1027–1033PubMedCrossRef Yamagami T, Kato T, Hiroto T et al (2006) Usefulness and limitation of manual aspiration immediately after pneumothorax complication interventional radiological procedures with the transthoracic approach. Cardiovasc Intervent Radiol 29:1027–1033PubMedCrossRef
17.
go back to reference Froelich JJ, Ishaque N, Regn J et al (2002) Guidance of percutaneous pulmonary biopsies with real-time CT. Eur J Radiol 42:74–79PubMedCrossRef Froelich JJ, Ishaque N, Regn J et al (2002) Guidance of percutaneous pulmonary biopsies with real-time CT. Eur J Radiol 42:74–79PubMedCrossRef
18.
go back to reference Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed
19.
go back to reference Priola AM, Priola SM, Cataldi A et al (2007) Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med 112:1142–1159PubMedCrossRef Priola AM, Priola SM, Cataldi A et al (2007) Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med 112:1142–1159PubMedCrossRef
20.
go back to reference Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automatic cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automatic cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef
21.
go back to reference Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed
Metadata
Title
Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
Authors
Sicco J. Braak
Gerarda J. M. Herder
Johannes P. M. van Heesewijk
Marco J. L. van Strijen
Publication date
01-12-2012
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 6/2012
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-011-0302-z

Other articles of this Issue 6/2012

CardioVascular and Interventional Radiology 6/2012 Go to the issue