Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 5/2013

01-05-2013 | Symposium: Special Considerations for TKA in Asian Patients

High-flexion Prosthesis Improves Function of TKA in Asian Patients Without Decreasing Early Survivorship

Authors: Bum-Sik Lee, MD, Jong-Won Chung, MD, Jong-Min Kim, MD, Kyung-Ah Kim, PhD, Seong-Il Bin, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 5/2013

Login to get access

Abstract

Background

Two previous studies recently raised the possibility of a high risk of early femoral components loosening with high-flexion (HF) prostheses in Asian populations and suggested that the high failure rate of HF TKAs was associated with HF ability. However, these findings are controversial given other studies reporting a low incidence of aseptic failures in HF prostheses.

Questions/purposes

We therefore determined (1) the rate of achieving postoperative HF after HF TKA; (2) whether the aseptic loosening rate of HF prostheses is high; and (3) whether the survivorship was worsened in patients who achieved postoperative deep knee flexion in our cohort of Korean patients.

Methods

We retrospectively reviewed 488 patients who had 698 primary TKAs using the NexGen® Legacy Posterior-Stabilized Flex system implanted from 2003 to 2010. There were 40 men and 448 women with a mean age of 68 years. We obtained Hospital for Special Surgery scores, maximal flexion, and radiographs. The minimum followup for functional and radiographic evaluations was 2 years (median, 4.8 years; range, 2–8.7 years). We performed a survival analysis on all patients for aseptic loosening.

Results

Three hundred sixty knees (52%) could achieve ≥ 135° maximum flexion. Six of the 698 knees (0.9%) developed aseptic loosening (three femoral and three tibial). The survival at 5 years for aseptic loosening was 99.1%. The overall survival for aseptic failure did not differ between knees that achieved HF and those that did not.

Conclusions

We observed a low incidence of early aseptic loosening of HF designs in this series. Our findings suggest HF TKAs have high survival in Asian patients at 5 years although half of the patients attained maximum flexion more than 135° postoperatively.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Ahmed I, Gray AC, van der Linden M, Nutton R. Range of flexion after primary TKA: the effect of soft tissue release and implant design. Orthopedics. 2009;32:811.PubMed Ahmed I, Gray AC, van der Linden M, Nutton R. Range of flexion after primary TKA: the effect of soft tissue release and implant design. Orthopedics. 2009;32:811.PubMed
2.
go back to reference Bach CM, Biedermann R, Goebel G, Mayer E, Rachbauer F. Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res. 2005;434:183–188.PubMedCrossRef Bach CM, Biedermann R, Goebel G, Mayer E, Rachbauer F. Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res. 2005;434:183–188.PubMedCrossRef
3.
go back to reference Bauman RD, Johnson DR, Menge TJ, Kim RH, Dennis DA. Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure? Clin Orthop Relat Res. 2012;470:150–158.PubMedCrossRef Bauman RD, Johnson DR, Menge TJ, Kim RH, Dennis DA. Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure? Clin Orthop Relat Res. 2012;470:150–158.PubMedCrossRef
4.
go back to reference Bertin KC. Cruciate-retaining total knee arthroplasty at 5 to 7 years followup. Clin Orthop Relat Res. 2005;436:177–183.PubMedCrossRef Bertin KC. Cruciate-retaining total knee arthroplasty at 5 to 7 years followup. Clin Orthop Relat Res. 2005;436:177–183.PubMedCrossRef
5.
go back to reference Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15:350–355.PubMedCrossRef Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15:350–355.PubMedCrossRef
6.
go back to reference Bollars P, Luyckx JP, Innocenti B, Labey L, Victor J, Bellemans J. Femoral component loosening in high-flexion total knee replacement: an in vitro comparison of high-flexion versus conventional designs. J Bone Joint Surg Br. 2011;93:1355–1361.PubMed Bollars P, Luyckx JP, Innocenti B, Labey L, Victor J, Bellemans J. Femoral component loosening in high-flexion total knee replacement: an in vitro comparison of high-flexion versus conventional designs. J Bone Joint Surg Br. 2011;93:1355–1361.PubMed
7.
go back to reference Cho SD, Youm YS, Park KB. Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc. 2011;19:899–903.PubMedCrossRef Cho SD, Youm YS, Park KB. Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc. 2011;19:899–903.PubMedCrossRef
8.
go back to reference Choi WC, Lee S, Seong SC, Jung JH, Lee MC. Comparison between standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties: a randomized controlled study. J Bone Joint Surg Am. 2010;92:2634–2642.PubMedCrossRef Choi WC, Lee S, Seong SC, Jung JH, Lee MC. Comparison between standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties: a randomized controlled study. J Bone Joint Surg Am. 2010;92:2634–2642.PubMedCrossRef
9.
go back to reference D’Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell CW Jr. In vivo contact stresses during activities of daily living after knee arthroplasty. J Orthop Res. 2008;26:1549–1555.PubMedCrossRef D’Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell CW Jr. In vivo contact stresses during activities of daily living after knee arthroplasty. J Orthop Res. 2008;26:1549–1555.PubMedCrossRef
10.
go back to reference Dalury DF, Gonzales RA, Adams MJ, Gruen TA, Trier K. Midterm results with the PFC Sigma total knee arthroplasty system. J Arthroplasty. 2008;23:175–181.PubMedCrossRef Dalury DF, Gonzales RA, Adams MJ, Gruen TA, Trier K. Midterm results with the PFC Sigma total knee arthroplasty system. J Arthroplasty. 2008;23:175–181.PubMedCrossRef
11.
go back to reference Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg. 2004;240:205–213.PubMedCrossRef Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg. 2004;240:205–213.PubMedCrossRef
12.
go back to reference Dobbs HS. Survivorship of total hip replacements. J Bone Joint Surg Br. 1980;62:168–173.PubMed Dobbs HS. Survivorship of total hip replacements. J Bone Joint Surg Br. 1980;62:168–173.PubMed
13.
go back to reference Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed
14.
go back to reference R, Tso P, Davey JR, Mahomed NN. High-flexion implants in primary total knee arthroplasty: a meta-analysis. Knee. 2009;16:14–17. R, Tso P, Davey JR, Mahomed NN. High-flexion implants in primary total knee arthroplasty: a meta-analysis. Knee. 2009;16:14–17.
15.
go back to reference Gonzalez MH, Mekhail AO. The failed total knee arthroplasty: evaluation and etiology. J Am Acad Orthop Surg. 2004;12:436–446.PubMed Gonzalez MH, Mekhail AO. The failed total knee arthroplasty: evaluation and etiology. J Am Acad Orthop Surg. 2004;12:436–446.PubMed
16.
go back to reference Gupta SK, Ranawat AS, Shah V, Zikria BA, Zikria JF, Ranawat CS. The PFC Sigma RP-F TKA designed for improved performance: a matched-pair study. Orthopedics. 2006;29:S49–52.PubMed Gupta SK, Ranawat AS, Shah V, Zikria BA, Zikria JF, Ranawat CS. The PFC Sigma RP-F TKA designed for improved performance: a matched-pair study. Orthopedics. 2006;29:S49–52.PubMed
17.
go back to reference Han HS, Kang SB, Yoon KS. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br. 2007;89:1457–1461.PubMedCrossRef Han HS, Kang SB, Yoon KS. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br. 2007;89:1457–1461.PubMedCrossRef
18.
go back to reference Huang HT, Su JY, Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty. 2005;20:674–679.PubMedCrossRef Huang HT, Su JY, Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty. 2005;20:674–679.PubMedCrossRef
19.
go back to reference Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am. 1976;58:754–765.PubMed Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am. 1976;58:754–765.PubMed
20.
go back to reference Kim TH, Lee DH, Bin SI. The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br. 2008;90:1304–1310.PubMedCrossRef Kim TH, Lee DH, Bin SI. The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br. 2008;90:1304–1310.PubMedCrossRef
21.
go back to reference Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC. Causes and predictors of patient’s dissatisfaction after uncomplicated total knee arthroplasty. J Arthroplasty. 2009;24:263–271.PubMedCrossRef Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC. Causes and predictors of patient’s dissatisfaction after uncomplicated total knee arthroplasty. J Arthroplasty. 2009;24:263–271.PubMedCrossRef
22.
go back to reference Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC. Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty. 2010;25:458–464.PubMedCrossRef Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC. Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty. 2010;25:458–464.PubMedCrossRef
23.
go back to reference Kim TW, Park SH, Suh JT. Comparison of mobile-bearing and fixed-bearing designs in high flexion total knee arthroplasty: using a navigation system. Knee Surg Relat Res. 2012;24:25–33.PubMedCrossRef Kim TW, Park SH, Suh JT. Comparison of mobile-bearing and fixed-bearing designs in high flexion total knee arthroplasty: using a navigation system. Knee Surg Relat Res. 2012;24:25–33.PubMedCrossRef
24.
go back to reference Kim YH, Choi Y, Kim JS. Comparison of a standard and a gender-specific posterior cruciate-substituting high-flexion knee prosthesis: a prospective, randomized, short-term outcome study. J Bone Joint Surg Am. 2010;92:1911–1920.PubMedCrossRef Kim YH, Choi Y, Kim JS. Comparison of a standard and a gender-specific posterior cruciate-substituting high-flexion knee prosthesis: a prospective, randomized, short-term outcome study. J Bone Joint Surg Am. 2010;92:1911–1920.PubMedCrossRef
25.
go back to reference Kim YH, Choi Y, Kwon OR, Kim JS. Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2009;91:753–760.PubMedCrossRef Kim YH, Choi Y, Kwon OR, Kim JS. Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2009;91:753–760.PubMedCrossRef
26.
go back to reference Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005;87:1470–1475.PubMedCrossRef Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005;87:1470–1475.PubMedCrossRef
27.
go back to reference King TV, Scott RD. Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res. 1985;194:285–290.PubMed King TV, Scott RD. Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res. 1985;194:285–290.PubMed
28.
go back to reference Kotani A, Yonekura A, Bourne RB. Factors influencing range of motion after contemporary total knee arthroplasty. J Arthroplasty. 2005;20:850–856.PubMedCrossRef Kotani A, Yonekura A, Bourne RB. Factors influencing range of motion after contemporary total knee arthroplasty. J Arthroplasty. 2005;20:850–856.PubMedCrossRef
29.
go back to reference Lee BS, Lee SJ, Kim JM, Lee DH, Cha EJ, Bin SI. No impact of severe varus deformity on clinical outcome after posterior stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2011;19:960–966.PubMedCrossRef Lee BS, Lee SJ, Kim JM, Lee DH, Cha EJ, Bin SI. No impact of severe varus deformity on clinical outcome after posterior stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2011;19:960–966.PubMedCrossRef
30.
go back to reference Massin P, Dupuy FR, Khlifi H, Fornasieri C, De Polignac T, Schifrine P, Farenq C, Mertl P. Does hyperflex total knee design improve postoperative active flexion? Orthop Traumatol Surg Res. 2010;96:376–380.PubMedCrossRef Massin P, Dupuy FR, Khlifi H, Fornasieri C, De Polignac T, Schifrine P, Farenq C, Mertl P. Does hyperflex total knee design improve postoperative active flexion? Orthop Traumatol Surg Res. 2010;96:376–380.PubMedCrossRef
31.
go back to reference Mehin R, Burnett RS, Brasher PM. Does the new generation of high-flex knee prostheses improve the post-operative range of movement? A meta-analysis. J Bone Joint Surg Br. 2010;92:1429–1434.PubMedCrossRef Mehin R, Burnett RS, Brasher PM. Does the new generation of high-flex knee prostheses improve the post-operative range of movement? A meta-analysis. J Bone Joint Surg Br. 2010;92:1429–1434.PubMedCrossRef
32.
go back to reference Mulholland SJ, Wyss UP. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res. 2001;24:191–198.PubMedCrossRef Mulholland SJ, Wyss UP. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res. 2001;24:191–198.PubMedCrossRef
33.
go back to reference Murphy M, Journeaux S, Russell T. High-flexion total knee arthroplasty: a systematic review. Int Orthop. 2009;33:887–893.PubMedCrossRef Murphy M, Journeaux S, Russell T. High-flexion total knee arthroplasty: a systematic review. Int Orthop. 2009;33:887–893.PubMedCrossRef
34.
go back to reference Ng FY, Wong HL, Yau WP, Chiu KY, Tang WM. Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement. Int Orthop. 2008;32:795–798.PubMedCrossRef Ng FY, Wong HL, Yau WP, Chiu KY, Tang WM. Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement. Int Orthop. 2008;32:795–798.PubMedCrossRef
35.
go back to reference Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Joint Surg Br. 2008;90:37–42.PubMedCrossRef Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone Joint Surg Br. 2008;90:37–42.PubMedCrossRef
36.
go back to reference Piedade SR, Pinaroli A, Servien E, Neyret P. Revision after early aseptic failures in primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2009;17:248–253.PubMedCrossRef Piedade SR, Pinaroli A, Servien E, Neyret P. Revision after early aseptic failures in primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2009;17:248–253.PubMedCrossRef
37.
go back to reference Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME. Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am. 2003;85:1278–1285.PubMed Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME. Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am. 2003;85:1278–1285.PubMed
38.
go back to reference Rowe PJ, Myles CM, Walker C, Nutton R. Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life? Gait Posture. 2000;12:143–155.PubMedCrossRef Rowe PJ, Myles CM, Walker C, Nutton R. Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life? Gait Posture. 2000;12:143–155.PubMedCrossRef
39.
go back to reference Scuderi GR, Hedden DR, Maltry JA, Traina SM, Sheinkop MB, Hartzband MA. Early clinical results of a high-flexion, posterior-stabilized, mobile-bearing total knee arthroplasty: a US investigational device exemption trial. J Arthroplasty. 2012;27:421–429.PubMedCrossRef Scuderi GR, Hedden DR, Maltry JA, Traina SM, Sheinkop MB, Hartzband MA. Early clinical results of a high-flexion, posterior-stabilized, mobile-bearing total knee arthroplasty: a US investigational device exemption trial. J Arthroplasty. 2012;27:421–429.PubMedCrossRef
40.
go back to reference Seng C, Yeo SJ, Wee JL, Subanesh S, Chong HC, Lo NN. Improved clinical outcomes after high-flexion total knee arthroplasty: a 5-year follow-up study. J Arthroplasty. 2011;26:1025–1030.PubMedCrossRef Seng C, Yeo SJ, Wee JL, Subanesh S, Chong HC, Lo NN. Improved clinical outcomes after high-flexion total knee arthroplasty: a 5-year follow-up study. J Arthroplasty. 2011;26:1025–1030.PubMedCrossRef
41.
go back to reference Seon JK, Park JK, Shin YJ, Seo HY, Lee KB, Song EK. Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs substituting designs. Knee Surg Sports Traumatol Arthrosc. 2011;19:2016–2022.PubMedCrossRef Seon JK, Park JK, Shin YJ, Seo HY, Lee KB, Song EK. Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs substituting designs. Knee Surg Sports Traumatol Arthrosc. 2011;19:2016–2022.PubMedCrossRef
42.
go back to reference Sharma A, Komistek RD, Scuderi GR, Cates HE Jr. High-flexion TKA designs: what are their in vivo contact mechanics? Clin Orthop Relat Res. 2007;464:117–126.PubMed Sharma A, Komistek RD, Scuderi GR, Cates HE Jr. High-flexion TKA designs: what are their in vivo contact mechanics? Clin Orthop Relat Res. 2007;464:117–126.PubMed
43.
go back to reference Tanavalee A, Ngarmukos S, Tantavisut S, Limtrakul A. High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up. Int Orthop. 2011;35:1321–1326.PubMedCrossRef Tanavalee A, Ngarmukos S, Tantavisut S, Limtrakul A. High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up. Int Orthop. 2011;35:1321–1326.PubMedCrossRef
44.
go back to reference Tanzer M, Smith K, Burnett S. Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gap. J Arthroplasty. 2002;17:813–819.PubMedCrossRef Tanzer M, Smith K, Burnett S. Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gap. J Arthroplasty. 2002;17:813–819.PubMedCrossRef
45.
go back to reference Tarabichi S, Tarabichi Y, Hawari M. Achieving deep flexion after primary total knee arthroplasty. J Arthroplasty. 2010;25:219–224.PubMedCrossRef Tarabichi S, Tarabichi Y, Hawari M. Achieving deep flexion after primary total knee arthroplasty. J Arthroplasty. 2010;25:219–224.PubMedCrossRef
46.
go back to reference Victor J, Ries M, Bellemans J, Robb WM, Van Hellemondt G. High-flexion, motion-guided total knee arthroplasty: who benefits the most? Orthopedics. 2007;30:77–79.PubMed Victor J, Ries M, Bellemans J, Robb WM, Van Hellemondt G. High-flexion, motion-guided total knee arthroplasty: who benefits the most? Orthopedics. 2007;30:77–79.PubMed
47.
go back to reference Weeden SH, Schmidt R. A randomized, prospective study of primary total knee components designed for increased flexion. J Arthroplasty. 2007;22:349–352.PubMedCrossRef Weeden SH, Schmidt R. A randomized, prospective study of primary total knee components designed for increased flexion. J Arthroplasty. 2007;22:349–352.PubMedCrossRef
48.
go back to reference Windsor RE, Scuderi GR, Moran MC, Insall JN. Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:15–19; discussion 19–20. Windsor RE, Scuderi GR, Moran MC, Insall JN. Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:15–19; discussion 19–20.
49.
go back to reference Wohlrab D, Hube R, Zeh A, Hein W. Clinical and radiological results of high flex total knee arthroplasty: a 5 year follow-up. Arch Orthop Trauma Surg. 2009;129:21–24.PubMedCrossRef Wohlrab D, Hube R, Zeh A, Hein W. Clinical and radiological results of high flex total knee arthroplasty: a 5 year follow-up. Arch Orthop Trauma Surg. 2009;129:21–24.PubMedCrossRef
50.
go back to reference Yagishita K, Muneta T, Ju YJ, Morito T, Yamazaki J, Sekiya I. High-flex posterior cruciate-retaining vs posterior cruciate-substituting designs in simultaneous bilateral total knee arthroplasty: a prospective, randomized study. J Arthroplasty. 2012;27:368–374.PubMedCrossRef Yagishita K, Muneta T, Ju YJ, Morito T, Yamazaki J, Sekiya I. High-flex posterior cruciate-retaining vs posterior cruciate-substituting designs in simultaneous bilateral total knee arthroplasty: a prospective, randomized study. J Arthroplasty. 2012;27:368–374.PubMedCrossRef
Metadata
Title
High-flexion Prosthesis Improves Function of TKA in Asian Patients Without Decreasing Early Survivorship
Authors
Bum-Sik Lee, MD
Jong-Won Chung, MD
Jong-Min Kim, MD
Kyung-Ah Kim, PhD
Seong-Il Bin, MD
Publication date
01-05-2013
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 5/2013
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2661-4

Other articles of this Issue 5/2013

Clinical Orthopaedics and Related Research® 5/2013 Go to the issue

Symposium: Special Considerations for TKA in Asian Patients

Comparative Demographics, ROM, and Function After TKA in Chinese, Malays, and Indians