Published in: Current Cardiovascular Imaging Reports 4/2013

01-08-2013 | Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

State of the Art in Cardiac Hybrid Technology: PET/MR

Authors: Carmela Nappi, Georges El Fakhri

Published in: Current Cardiovascular Imaging Reports | Issue 4/2013

Login to get access

Abstract

Simultaneous PET/MRI is an emerging technique combining two powerful imaging modalities in a single device. The wide variety of available tracers for perfusion and metabolic studies and the high sensitivity of positron emission tomography (PET) combined with the high spatial resolution and soft tissue contrast of magnetic resonance imaging (MRI) in depicting cardiac morphology and function as well as MRI’s absence of ionizing radiation makes PET/MRI very attractive to radiologists and clinicians. Nevertheless, PET/MR scientific and clinical promise is to be considered in the context of numerous technical challenges that hinder its use in the clinical setting. For example, in order for a PET system to work correctly within an MR field, major changes are required to the photon detection chain such as the elimination of photomultiplier tubes, etc. Another significant limitation of PET/MRI is the lack of an electron density map (as is the case with PET-CT) that can be readily obtained from MRI (the latter measures proton not electron density) and used to correct PET data for attenuation. Moreover, as with PET-CT, cardiac and respiratory motions cause image degradations that affect image quality and accuracy both in static and dynamic PET imaging. As a result, overcoming these (and other) technical limitations is a very active area of research both in academic institutions as well as industry. In this paper, we review recent literature on cardiac PET/MRI, present the state-of-the-art of this technology, and explore promising preclinical and clinical cardiac applications where PET/MRI could play a substantial role.
Literature
1.
go back to reference Nesto RW, Kowalchuk GJ. The ischemic cascade: temporal sequence of hemodynamic, electrocardiographic and symptomatic expressions of ischemia. Am J Cardiol. 1987;59(7):23C–30.PubMedCrossRef Nesto RW, Kowalchuk GJ. The ischemic cascade: temporal sequence of hemodynamic, electrocardiographic and symptomatic expressions of ischemia. Am J Cardiol. 1987;59(7):23C–30.PubMedCrossRef
2.
go back to reference Loghin C, Sdringola S, Gould KL. Common artifacts in PET myocardial perfusion images due to attenuation–emission misregistration: clinical significance, causes, and solutions. J Nucl Med. 2004;45(6):1029–39.PubMed Loghin C, Sdringola S, Gould KL. Common artifacts in PET myocardial perfusion images due to attenuation–emission misregistration: clinical significance, causes, and solutions. J Nucl Med. 2004;45(6):1029–39.PubMed
3.
go back to reference Di Carli MF, Dorbala S, Hachamovitch R. Integrated cardiac PET-CT for the diagnosis and management of CAD. J Nucl Cardiol. 2006;13(2):139–44.PubMedCrossRef Di Carli MF, Dorbala S, Hachamovitch R. Integrated cardiac PET-CT for the diagnosis and management of CAD. J Nucl Cardiol. 2006;13(2):139–44.PubMedCrossRef
4.
5.
go back to reference Miller SW, Boxt L, Abbara S. The requisites—cardiac imaging. 3rd ed. Elseviers Mosby; 2009. ISBN-13: 978-0323055277. Miller SW, Boxt L, Abbara S. The requisites—cardiac imaging. 3rd ed. Elseviers Mosby; 2009. ISBN-13: 978-0323055277.
6.
go back to reference • Petibon Y et al. Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study. Phys Med Biol. 2013;58(7):2085–102. Good paper about a novel method for cardiac motion compensation in a list-mode iterative reconstruction framework in simultaneous PET-MR.PubMedCrossRef • Petibon Y et al. Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study. Phys Med Biol. 2013;58(7):2085–102. Good paper about a novel method for cardiac motion compensation in a list-mode iterative reconstruction framework in simultaneous PET-MR.PubMedCrossRef
7.
go back to reference •• Rischpler C et al. Hybrid PET/MR imaging of the heart: potential, initial experiences, and future prospects. J Nucl Med. 2013;54(3):402–15. Great review of hybrid PET/MRI application in heart disease.PubMedCrossRef •• Rischpler C et al. Hybrid PET/MR imaging of the heart: potential, initial experiences, and future prospects. J Nucl Med. 2013;54(3):402–15. Great review of hybrid PET/MRI application in heart disease.PubMedCrossRef
8.
go back to reference Koepfli P et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J Nucl Med. 2004;45(4):537–42.PubMed Koepfli P et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J Nucl Med. 2004;45(4):537–42.PubMed
9.
go back to reference Zhang H et al. Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005;53(5):1135–42.PubMedCrossRef Zhang H et al. Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005;53(5):1135–42.PubMedCrossRef
10.
11.
go back to reference Zaidi H et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol. 2011;56(10):3091–106.PubMedCrossRef Zaidi H et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol. 2011;56(10):3091–106.PubMedCrossRef
12.
go back to reference Veit-Haibach P et al. PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine. MAGMA. 2013;26(1):25–35.PubMedCrossRef Veit-Haibach P et al. PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine. MAGMA. 2013;26(1):25–35.PubMedCrossRef
13.
go back to reference Delso G et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med. 2011;52(12):1914–22.PubMedCrossRef Delso G et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med. 2011;52(12):1914–22.PubMedCrossRef
14.
go back to reference Judenhofer MS, Cherry SR. Applications for preclinical PET/MRI. Semin Nucl Med. 2013;43(1):19–29.PubMedCrossRef Judenhofer MS, Cherry SR. Applications for preclinical PET/MRI. Semin Nucl Med. 2013;43(1):19–29.PubMedCrossRef
15.
go back to reference Judenhofer MS et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14(4):459–65.PubMedCrossRef Judenhofer MS et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14(4):459–65.PubMedCrossRef
16.
go back to reference Prince JL, McVeigh ER. Motion estimation from tagged MR image sequences. IEEE Trans Med Imaging. 1992;11(2):238–49.PubMedCrossRef Prince JL, McVeigh ER. Motion estimation from tagged MR image sequences. IEEE Trans Med Imaging. 1992;11(2):238–49.PubMedCrossRef
17.
go back to reference Chun SY et al. MRI-based nonrigid motion correction in simultaneous PET/MRI. J Nucl Med. 2012;53(8):1284–91.PubMedCrossRef Chun SY et al. MRI-based nonrigid motion correction in simultaneous PET/MRI. J Nucl Med. 2012;53(8):1284–91.PubMedCrossRef
18.
go back to reference Stickel JR, Cherry SR. High-resolution PET detector design: modelling components of intrinsic spatial resolution. Phys Med Biol. 2005;50(2):179–95.PubMedCrossRef Stickel JR, Cherry SR. High-resolution PET detector design: modelling components of intrinsic spatial resolution. Phys Med Biol. 2005;50(2):179–95.PubMedCrossRef
19.
go back to reference Sureau FC et al. Impact of image-space resolution modeling for studies with the high-resolution research tomograph. J Nucl Med. 2008;49(6):1000–8.PubMedCrossRef Sureau FC et al. Impact of image-space resolution modeling for studies with the high-resolution research tomograph. J Nucl Med. 2008;49(6):1000–8.PubMedCrossRef
20.
go back to reference Wiant D et al. Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM. Med Phys. 2010;37(3):1169–82.PubMedCrossRef Wiant D et al. Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM. Med Phys. 2010;37(3):1169–82.PubMedCrossRef
21.
go back to reference Alessio AM et al. Application and evaluation of a measured spatially variant system model for PET image reconstruction. IEEE Trans Med Imaging. 2010;29(3):938–49.PubMedCrossRef Alessio AM et al. Application and evaluation of a measured spatially variant system model for PET image reconstruction. IEEE Trans Med Imaging. 2010;29(3):938–49.PubMedCrossRef
22.
go back to reference Boucher L et al. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J Nucl Med. 2004;45(2):214–9.PubMed Boucher L et al. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J Nucl Med. 2004;45(2):214–9.PubMed
23.
go back to reference Blume M, Navab N, Rafecas M. Joint image and motion reconstruction for PET using a B-spline motion model. Phys Med Biol. 2012;57(24):8249–70.PubMedCrossRef Blume M, Navab N, Rafecas M. Joint image and motion reconstruction for PET using a B-spline motion model. Phys Med Biol. 2012;57(24):8249–70.PubMedCrossRef
24.
go back to reference Buscher K et al. Isochronous assessment of cardiac metabolism and function in mice using hybrid PET/MRI. J Nucl Med. 2010;51(8):1277–84.PubMedCrossRef Buscher K et al. Isochronous assessment of cardiac metabolism and function in mice using hybrid PET/MRI. J Nucl Med. 2010;51(8):1277–84.PubMedCrossRef
25.
go back to reference Lee WW et al. PET/MRI of inflammation in myocardial infarction. J Am Coll Cardiol. 2012;59(2):153–63.PubMedCrossRef Lee WW et al. PET/MRI of inflammation in myocardial infarction. J Am Coll Cardiol. 2012;59(2):153–63.PubMedCrossRef
26.
go back to reference Ouyang J, Li Q, El Fakhri G. Magnetic resonance-based motion correction for positron emission tomography imaging. Semin Nucl Med. 2013;43(1):60–7.PubMedCrossRef Ouyang J, Li Q, El Fakhri G. Magnetic resonance-based motion correction for positron emission tomography imaging. Semin Nucl Med. 2013;43(1):60–7.PubMedCrossRef
27.
go back to reference Higuchi T et al. Targeting of endothelin receptors in the healthy and infarcted rat heart using the PET tracer 18F-FBzBMS. J Nucl Med. 2013;54(2):277–82.PubMedCrossRef Higuchi T et al. Targeting of endothelin receptors in the healthy and infarcted rat heart using the PET tracer 18F-FBzBMS. J Nucl Med. 2013;54(2):277–82.PubMedCrossRef
28.
go back to reference Majmudar MD, Nahrendorf M. Cardiovascular molecular imaging: the road ahead. J Nucl Med. 2012;53(5):673–6.PubMedCrossRef Majmudar MD, Nahrendorf M. Cardiovascular molecular imaging: the road ahead. J Nucl Med. 2012;53(5):673–6.PubMedCrossRef
29.
go back to reference Majmudar MD et al. Polymeric nanoparticle PET/MR imaging allows macrophage detection in atherosclerotic plaques. Circ Res. 2013;112(5):755–61.PubMedCrossRef Majmudar MD et al. Polymeric nanoparticle PET/MR imaging allows macrophage detection in atherosclerotic plaques. Circ Res. 2013;112(5):755–61.PubMedCrossRef
30.
go back to reference Parker MW et al. Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis. Circ Cardiovasc Imaging. 2012;5(6):700–7.PubMedCrossRef Parker MW et al. Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis. Circ Cardiovasc Imaging. 2012;5(6):700–7.PubMedCrossRef
31.
go back to reference de Jong MC et al. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. Eur Radiol. 2012;22(9):1881–95.PubMedCrossRef de Jong MC et al. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. Eur Radiol. 2012;22(9):1881–95.PubMedCrossRef
32.
go back to reference Koller A, Balasko M, Bagi Z. Endothelial regulation of coronary microcirculation in health and cardiometabolic diseases. Intern Emerg Med. 2013;8 Suppl 1:51–4.CrossRef Koller A, Balasko M, Bagi Z. Endothelial regulation of coronary microcirculation in health and cardiometabolic diseases. Intern Emerg Med. 2013;8 Suppl 1:51–4.CrossRef
33.
go back to reference Rischpler C et al. Advances in PET myocardial perfusion imaging: F-18 labeled tracers. Ann Nucl Med. 2012;26(1):1–6.PubMedCrossRef Rischpler C et al. Advances in PET myocardial perfusion imaging: F-18 labeled tracers. Ann Nucl Med. 2012;26(1):1–6.PubMedCrossRef
34.
go back to reference Berman DS, Germano G, Slomka PJ. Improvement in PET myocardial perfusion image quality and quantification with flurpiridaz F 18. J Nucl Cardiol. 2012;19 Suppl 1:S38–45.PubMedCrossRef Berman DS, Germano G, Slomka PJ. Improvement in PET myocardial perfusion image quality and quantification with flurpiridaz F 18. J Nucl Cardiol. 2012;19 Suppl 1:S38–45.PubMedCrossRef
35.
go back to reference Dweck MR et al. Coronary arterial 18F-sodium fluoride uptake: a novel marker of plaque biology. J Am Coll Cardiol. 2012;59(17):1539–48.PubMedCrossRef Dweck MR et al. Coronary arterial 18F-sodium fluoride uptake: a novel marker of plaque biology. J Am Coll Cardiol. 2012;59(17):1539–48.PubMedCrossRef
36.
go back to reference Dweck MR et al. Assessment of valvular calcification and inflammation by positron emission tomography in patients with aortic stenosis. Circulation. 2012;125(1):76–86.PubMedCrossRef Dweck MR et al. Assessment of valvular calcification and inflammation by positron emission tomography in patients with aortic stenosis. Circulation. 2012;125(1):76–86.PubMedCrossRef
38.
go back to reference O’Meara C, Menezes LJ, White SK, Elliott P. Inital experience of imaging cardiac sarcoidosis using hybrid PET-MR—a technologist's case study. J Cardiovasc Magn Reson. 2013. doi:10.1186/1532-429X-15-S1-T1. O’Meara C, Menezes LJ, White SK, Elliott P. Inital experience of imaging cardiac sarcoidosis using hybrid PET-MR—a technologist's case study. J Cardiovasc Magn Reson. 2013. doi:10.​1186/​1532-429X-15-S1-T1.
39.
go back to reference Youssef G et al. The use of 18F-FDG PET in the diagnosis of cardiac sarcoidosis: a systematic review and metaanalysis including the Ontario experience. J Nucl Med. 2012;53(2):241–8.PubMedCrossRef Youssef G et al. The use of 18F-FDG PET in the diagnosis of cardiac sarcoidosis: a systematic review and metaanalysis including the Ontario experience. J Nucl Med. 2012;53(2):241–8.PubMedCrossRef
40.
go back to reference Ibrahim T et al. Simultaneous positron emission tomography/magnetic resonance imaging identifies sustained regional abnormalities in cardiac metabolism and function in stress-induced transient midventricular ballooning syndrome: a variant of Takotsubo cardiomyopathy. Circulation. 2012;126(21):e324–6.PubMedCrossRef Ibrahim T et al. Simultaneous positron emission tomography/magnetic resonance imaging identifies sustained regional abnormalities in cardiac metabolism and function in stress-induced transient midventricular ballooning syndrome: a variant of Takotsubo cardiomyopathy. Circulation. 2012;126(21):e324–6.PubMedCrossRef
41.
go back to reference Rota Kops E, Herzog H. Alternative methods for attenuation correction for PET images in MR-PET scanners. IEEE Nucl Sci Symp Conf Rec. 2007;6:4327–30. Rota Kops E, Herzog H. Alternative methods for attenuation correction for PET images in MR-PET scanners. IEEE Nucl Sci Symp Conf Rec. 2007;6:4327–30.
42.
go back to reference Rota Kops E, Qin P, Muller-Veggian M, Herzog H. MRI based attenuation correction for brain PET images. Springer Proc Phys. 2007;114:93–7.CrossRef Rota Kops E, Qin P, Muller-Veggian M, Herzog H. MRI based attenuation correction for brain PET images. Springer Proc Phys. 2007;114:93–7.CrossRef
43.
go back to reference Beyer T et al. MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med Mol Imaging. 2008;35(6):1142–6.PubMedCrossRef Beyer T et al. MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med Mol Imaging. 2008;35(6):1142–6.PubMedCrossRef
44.
go back to reference Hofmann M et al. MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008;49(11):1875–83.PubMedCrossRef Hofmann M et al. MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008;49(11):1875–83.PubMedCrossRef
45.
go back to reference Hofmann M et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med. 2011;52(9):1392–9.PubMedCrossRef Hofmann M et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med. 2011;52(9):1392–9.PubMedCrossRef
46.
go back to reference Steinberg J et al. Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol. 2010;37(2):227–35.PubMedCrossRef Steinberg J et al. Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol. 2010;37(2):227–35.PubMedCrossRef
47.
go back to reference Martinez-Moller A et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50(4):520–6.PubMedCrossRef Martinez-Moller A et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50(4):520–6.PubMedCrossRef
48.
go back to reference Schulz V et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging. 2011;38(1):138–52.PubMedCrossRef Schulz V et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging. 2011;38(1):138–52.PubMedCrossRef
49.
go back to reference Eiber M et al. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions. Eur J Nucl Med Mol Imaging. 2011;38(9):1691–701.PubMedCrossRef Eiber M et al. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions. Eur J Nucl Med Mol Imaging. 2011;38(9):1691–701.PubMedCrossRef
50.
go back to reference Catana C, Guimaraes AR, Rosen BR. PET and MR Imaging: the odd couple or a match made in heaven? J Nucl Med. 2013; Mar 14. [Epub ahead of print]. Catana C, Guimaraes AR, Rosen BR. PET and MR Imaging: the odd couple or a match made in heaven? J Nucl Med. 2013; Mar 14. [Epub ahead of print].
Metadata
Title
State of the Art in Cardiac Hybrid Technology: PET/MR
Authors
Carmela Nappi
Georges El Fakhri
Publication date
01-08-2013
Publisher
Springer US
Published in
Current Cardiovascular Imaging Reports / Issue 4/2013
Print ISSN: 1941-9066
Electronic ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-013-9213-5

Other articles of this Issue 4/2013

Current Cardiovascular Imaging Reports 4/2013 Go to the issue

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

Advances in Molecular Imaging: Cardiac Regeneration

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

New Software Solutions for Cardiac SPECT Imaging