Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer

Authors: Hongbo Chai, Yuichiro Narita, Masafumi Takagi, Mikiko Kudo, Tomomi Kimura, Keiichi Kattou

Published in: Radiological Physics and Technology | Issue 4/2019

Login to get access

Abstract

This study aimed to investigate an improved setup protocol for maintaining patient setup accuracy, with minimal or no use of image-guided radiation therapy in conventional radiotherapy for lung cancer. A coordinate value for the treatment couch in the anterior–posterior (AP) direction was obtained from the first fraction using bony anatomy image guidance. The coordinate value was invariably used for patient positioning in the second and subsequent treatment fractions. The errors of 2410 setup image sets (anterior and lateral) from 105 patients with lung cancer were analyzed. The systematic and random patient positioning errors in the AP direction were 0.6 ± 1.0 mm. Such errors accounted for 97% of all fractions within ± 2 mm. The protocol resulted in minimal patient setup errors in the AP direction using only one image for guidance; therefore, it may be applied to conventional radiotherapy for lung cancer in case of insufficient image guidance.
Literature
1.
go back to reference Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. J clin oncol. 2007;25:938–46.CrossRef Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. J clin oncol. 2007;25:938–46.CrossRef
2.
go back to reference Bujold A, Craig T, Jaffray D, Dawson LA. Image-guided radiotherapy: has it influenced patient outcomes? Semin Radiat Oncol. 2012;22:50–61.CrossRef Bujold A, Craig T, Jaffray D, Dawson LA. Image-guided radiotherapy: has it influenced patient outcomes? Semin Radiat Oncol. 2012;22:50–61.CrossRef
3.
go back to reference Guckenberger M, Meyer J, Wilbert J, et al. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol. 2006;45:897–906.CrossRef Guckenberger M, Meyer J, Wilbert J, et al. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol. 2006;45:897–906.CrossRef
4.
go back to reference Benedict SH, Yenice KM, Followill D, et al. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37(8):4078–101.CrossRef Benedict SH, Yenice KM, Followill D, et al. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37(8):4078–101.CrossRef
5.
go back to reference Higgins J, Bezjak A, Franks K, et al. Comparison of spine, carina, and tumor as registration landmarks for volumetric image-guided lung radiotherapy. Int J Radiat Oncol Biol Phys. 2009;73:1404–13.CrossRef Higgins J, Bezjak A, Franks K, et al. Comparison of spine, carina, and tumor as registration landmarks for volumetric image-guided lung radiotherapy. Int J Radiat Oncol Biol Phys. 2009;73:1404–13.CrossRef
6.
go back to reference Schmidt ML, Hoffmann L, Kandi M, Møller DS, Poulsen PR. Dosimetric impact of respiratory motion, interfraction baseline shifts, and anatomical changes in radiotherapy of non-small cell lung cancer. Acta Oncol. 2013;52:1490–6.CrossRef Schmidt ML, Hoffmann L, Kandi M, Møller DS, Poulsen PR. Dosimetric impact of respiratory motion, interfraction baseline shifts, and anatomical changes in radiotherapy of non-small cell lung cancer. Acta Oncol. 2013;52:1490–6.CrossRef
7.
go back to reference Murphy M, Balter JM, BenComo J, et al. The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. Med Phys. 2007;34:4041–63.CrossRef Murphy M, Balter JM, BenComo J, et al. The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. Med Phys. 2007;34:4041–63.CrossRef
8.
go back to reference Ding GX, Coffey CW. Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys. 2009;73:610–7.CrossRef Ding GX, Coffey CW. Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys. 2009;73:610–7.CrossRef
9.
go back to reference Ding GX, Munro P, Pawlowski J, Malcolm A, Coffey CW. Reducing radiation exposure to patients from kV-CBCT imaging. Radiother Oncol. 2010;97:585–92.CrossRef Ding GX, Munro P, Pawlowski J, Malcolm A, Coffey CW. Reducing radiation exposure to patients from kV-CBCT imaging. Radiother Oncol. 2010;97:585–92.CrossRef
10.
go back to reference Nabavizadeh N, Elliott DA, Chen Y, et al. Image guided radiation therapy (IGRT) practice patterns and IGRT’s impact on workflow and treatment planning: results from a national survey of American Society for Radiation Oncology members. Int J Radiat Oncol Biol Phys. 2016;94:850–7.CrossRef Nabavizadeh N, Elliott DA, Chen Y, et al. Image guided radiation therapy (IGRT) practice patterns and IGRT’s impact on workflow and treatment planning: results from a national survey of American Society for Radiation Oncology members. Int J Radiat Oncol Biol Phys. 2016;94:850–7.CrossRef
11.
go back to reference de Boer JCJ, Heijmen BJM. A protocol for the reduction of systematic patient set-up errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys. 2001;50:1350–65.CrossRef de Boer JCJ, Heijmen BJM. A protocol for the reduction of systematic patient set-up errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys. 2001;50:1350–65.CrossRef
12.
go back to reference de Boer JCJ, van Os MJH, Jansen PP, et al. Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers. Int J Radiat Oncol Biol Phys. 2005;61:969–83.CrossRef de Boer JCJ, van Os MJH, Jansen PP, et al. Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers. Int J Radiat Oncol Biol Phys. 2005;61:969–83.CrossRef
13.
go back to reference Higgins J, Bezjak A, Hope A, et al. Effect of image-guidance frequency on geometric accuracy and setup margins in radiotherapy for locally advanced lung cancer. Int J Radiat Oncol Biol Phys. 2011;80(5):1330–7.CrossRef Higgins J, Bezjak A, Hope A, et al. Effect of image-guidance frequency on geometric accuracy and setup margins in radiotherapy for locally advanced lung cancer. Int J Radiat Oncol Biol Phys. 2011;80(5):1330–7.CrossRef
14.
go back to reference Greer P, Mortensen T, Jose C. Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging. Int J Radiat Oncol Biol Phys. 1998;41:1193–9.CrossRef Greer P, Mortensen T, Jose C. Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging. Int J Radiat Oncol Biol Phys. 1998;41:1193–9.CrossRef
15.
go back to reference van Lin EN, Nijenhuis E, Huizenga H, van der Vight L, Visser A. Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys. 2001;50:569–77.CrossRef van Lin EN, Nijenhuis E, Huizenga H, van der Vight L, Visser A. Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys. 2001;50:569–77.CrossRef
16.
go back to reference Roels S, Verstraete J, Hausterman K. Set-up verification on a belly-board device using electronic portal imaging. J Radiother Pract. 2007;5:1–10. Roels S, Verstraete J, Hausterman K. Set-up verification on a belly-board device using electronic portal imaging. J Radiother Pract. 2007;5:1–10.
17.
go back to reference Ohira S, Ueda Y, Nishiyama K, et al. Couch height-based patient setup for abdominal radiation therapy. Med Dosim. 2016;41:59–63.CrossRef Ohira S, Ueda Y, Nishiyama K, et al. Couch height-based patient setup for abdominal radiation therapy. Med Dosim. 2016;41:59–63.CrossRef
18.
go back to reference Petillion S, Verhoeven K, Weltens C, Van den Heuvel F. Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action–level protocol in whole-breast radiotherapy. J Appl Clin Med Phys. 2015;16(2):79–290.CrossRef Petillion S, Verhoeven K, Weltens C, Van den Heuvel F. Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action–level protocol in whole-breast radiotherapy. J Appl Clin Med Phys. 2015;16(2):79–290.CrossRef
19.
go back to reference Maxim PG, Loo BW, Murphy JD, Chu KP, Hsu A, Le QT. On-board imaging validation of optically guided stereotactic radiosurgery positioning system for conventionally fractionated radiotherapy for paranasal sinus and skull base cancer. Int J Radiat Oncol Biol Phys. 2011;81:1153–9.CrossRef Maxim PG, Loo BW, Murphy JD, Chu KP, Hsu A, Le QT. On-board imaging validation of optically guided stereotactic radiosurgery positioning system for conventionally fractionated radiotherapy for paranasal sinus and skull base cancer. Int J Radiat Oncol Biol Phys. 2011;81:1153–9.CrossRef
20.
go back to reference Rønde HS, Hoffmann L. Validation of Varian’s AAA algorithm with focus on lung treatments. Acta Oncol. 2009;48(2):209–15.CrossRef Rønde HS, Hoffmann L. Validation of Varian’s AAA algorithm with focus on lung treatments. Acta Oncol. 2009;48(2):209–15.CrossRef
21.
go back to reference International Commission on Radiation Units and Measurements. ICRU report 62: Prescribing, recording, and reporting photon beam therapy (supplement to ICRU report 50). Bethesda: International Commission on Radiation Units and Measurements; 1999. International Commission on Radiation Units and Measurements. ICRU report 62: Prescribing, recording, and reporting photon beam therapy (supplement to ICRU report 50). Bethesda: International Commission on Radiation Units and Measurements; 1999.
22.
go back to reference Van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14:52–64.CrossRef Van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14:52–64.CrossRef
23.
go back to reference Borst GR, Sonke JJ, Betgen A, Remeijer P, van Herk M, Lebesque JV. Kilo-voltage cone-beam computed tomography setup ́measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys. 2007;68:555–61.CrossRef Borst GR, Sonke JJ, Betgen A, Remeijer P, van Herk M, Lebesque JV. Kilo-voltage cone-beam computed tomography setup ́measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys. 2007;68:555–61.CrossRef
24.
go back to reference Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008;70:1045–56.CrossRef Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008;70:1045–56.CrossRef
25.
go back to reference Yeung AR, Li JG, Shi W, Newlin HE, Chvetsov A, Liu C, et al. Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors. Int J Radiat Oncol Biol Phys. 2009;74:1100–7.CrossRef Yeung AR, Li JG, Shi W, Newlin HE, Chvetsov A, Liu C, et al. Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors. Int J Radiat Oncol Biol Phys. 2009;74:1100–7.CrossRef
26.
go back to reference Worm ES, Hansen AT, Petersen JB, Muren LP, Præstegaard LH, Høyer M. Inter-and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung. Acta Oncol. 2010;49(7):1177–83.CrossRef Worm ES, Hansen AT, Petersen JB, Muren LP, Præstegaard LH, Høyer M. Inter-and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung. Acta Oncol. 2010;49(7):1177–83.CrossRef
27.
go back to reference Bissonnette JP, Purdie TG, Higgins JA, Li W, Bezjak A. Cone-beam computed tomographic image guidance for lung cancer radiation therapy. Int J Radiat Oncol Biol Phys. 2009;73(3):927–34.CrossRef Bissonnette JP, Purdie TG, Higgins JA, Li W, Bezjak A. Cone-beam computed tomographic image guidance for lung cancer radiation therapy. Int J Radiat Oncol Biol Phys. 2009;73(3):927–34.CrossRef
28.
go back to reference Mesías MC, Boda-Heggemann J, Thoelking J, Lohr F, Wenz F, Wertz H. Quantification and assessment of interfraction setup errors based on cone beam CT and determination of safety margins for radiotherapy. PLoS ONE. 2016;11(3):e0150326.CrossRef Mesías MC, Boda-Heggemann J, Thoelking J, Lohr F, Wenz F, Wertz H. Quantification and assessment of interfraction setup errors based on cone beam CT and determination of safety margins for radiotherapy. PLoS ONE. 2016;11(3):e0150326.CrossRef
29.
go back to reference Kapandji AI, editor. Shiota E, translator. Anatomie fonctionnelle, Tome 3. 6th edn. Tokyo: Ishiyaku; 2010, pp. 146–7. (Japanese). Kapandji AI, editor. Shiota E, translator. Anatomie fonctionnelle, Tome 3. 6th edn. Tokyo: Ishiyaku; 2010, pp. 146–7. (Japanese).
30.
go back to reference Oatis CA, editor. Yamasaki A, Sato S, Shirahoshi S, translators. Kinesiology, The mechanics and pathomechanics of human movement. 2nd edn. Tokyo: Round flat. 2012; pp. 537–8. (Japanese). Oatis CA, editor. Yamasaki A, Sato S, Shirahoshi S, translators. Kinesiology, The mechanics and pathomechanics of human movement. 2nd edn. Tokyo: Round flat. 2012; pp. 537–8. (Japanese).
31.
go back to reference Purdie TG, Bissonnette JP, Franks K, et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys. 2007;68:243–52.CrossRef Purdie TG, Bissonnette JP, Franks K, et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys. 2007;68:243–52.CrossRef
32.
go back to reference Oehler C, Lang S, Dimmerling P, Bolesch C, Kloeck S, Tini A, et al. PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers. Radiat Oncol. 2014;9:229.CrossRef Oehler C, Lang S, Dimmerling P, Bolesch C, Kloeck S, Tini A, et al. PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers. Radiat Oncol. 2014;9:229.CrossRef
33.
go back to reference Fontanarosa D, van der Meer S, Bamber J, Harris E, O’Shea T, Verhaegen F. Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management. Phys Med Biol. 2015;60(3):R77–114.CrossRef Fontanarosa D, van der Meer S, Bamber J, Harris E, O’Shea T, Verhaegen F. Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management. Phys Med Biol. 2015;60(3):R77–114.CrossRef
34.
go back to reference Alvarado R, Booth JT, Bromley RM, Gustafsson HB. An investigation of image guidance dose for breast radiotherapy. J Appl Clin Med Phys. 2013;14(3):25–38.CrossRef Alvarado R, Booth JT, Bromley RM, Gustafsson HB. An investigation of image guidance dose for breast radiotherapy. J Appl Clin Med Phys. 2013;14(3):25–38.CrossRef
35.
go back to reference Moon YM, Kim HJ, Kwak DW, et al. Effective dose measurement for cone beam computed tomography using glass dosimeter. Nucl Eng Technol. 2014;46:255–62.CrossRef Moon YM, Kim HJ, Kwak DW, et al. Effective dose measurement for cone beam computed tomography using glass dosimeter. Nucl Eng Technol. 2014;46:255–62.CrossRef
Metadata
Title
Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer
Authors
Hongbo Chai
Yuichiro Narita
Masafumi Takagi
Mikiko Kudo
Tomomi Kimura
Keiichi Kattou
Publication date
01-12-2019
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 4/2019
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00537-3

Other articles of this Issue 4/2019

Radiological Physics and Technology 4/2019 Go to the issue

Acknowledgments

Acknowledgment