Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging

Authors: Anthony Merlocco, Laura Olivieri, Peter Kellman, Hui Xue, Russell Cross

Published in: Pediatric Cardiology | Issue 1/2019

Login to get access

Abstract

Cardiac MR traditionally requires breath-holding for cine imaging. Younger or less stable patients benefit from free-breathing during cardiac MR but current free-breathing cine images can be spatially blurred. Motion corrected re-binning (MOC) is a novel approach that acquires and then reformats real-time images over multiple cardiac cycles with high spatial resolution. The technique was previously limited by reconstruction time but distributed computing has reduced these times. Using this technique, left ventricular volumetry has compared favorably to breath-held balanced steady-state free precession cine imaging (BH), the current gold-standard, however, right ventricular volumetry validation remains incomplete, limiting the applicability of MOC in clinical practice. Fifty subjects underwent cardiac MR for evaluation of right ventricular size and function by end-diastolic (EDV) and end-systolic (ESV) volumetry. Measurements using MOC were compared to those using BH. Pearson correlation coefficients and Bland–Altman plots tested agreement across techniques. Total scan plus reconstruction times were tested for significant differences using paired t-test. Volumes obtained by MOC compared favorably to BH (R = 0.9911 for EDV, 0.9690 for ESV). Combined acquisition and reconstruction time (previously reported) were reduced 37% for MOC, requiring a mean of 5.2 min compared to 8.2 min for BH (p < 0.0001). Right ventricular volumetry compares favorably to BH using MOC image reconstruction, but is obtained in a fraction of the time. Combined with previous validation of its use for the left ventricle, this novel method now offers an alternative imaging approach in appropriate clinical settings.
Literature
3.
go back to reference Scheffler KLS (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13:2409–2418CrossRefPubMed Scheffler KLS (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13:2409–2418CrossRefPubMed
5.
go back to reference Maceira A, Prasad S, Khan MPD (2006) Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 8:417–426CrossRefPubMed Maceira A, Prasad S, Khan MPD (2006) Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 8:417–426CrossRefPubMed
8.
go back to reference Pattynama PM, Lamb HJ, van der Velde EA, van der Wall EE, de Ross A (1993) Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 187:261–268CrossRefPubMed Pattynama PM, Lamb HJ, van der Velde EA, van der Wall EE, de Ross A (1993) Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 187:261–268CrossRefPubMed
11.
go back to reference Kühl HP, Spuentrup E, Wall A, Franke A, Schröder J, Heussen N, Hanrath P, Gunther RBA (2004) Assessment of myocardial function with interactive non-breath-hold realtime MR imaging: comparison with echocardiography and breath-hold cine MR imaging. Radiology 231(1):198–207CrossRefPubMed Kühl HP, Spuentrup E, Wall A, Franke A, Schröder J, Heussen N, Hanrath P, Gunther RBA (2004) Assessment of myocardial function with interactive non-breath-hold realtime MR imaging: comparison with echocardiography and breath-hold cine MR imaging. Radiology 231(1):198–207CrossRefPubMed
12.
go back to reference Lee VS, Resnick D, Bundy JM, Simonetti OP, Lee PWJ (2002) Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession. Radiology 222:835–842CrossRefPubMed Lee VS, Resnick D, Bundy JM, Simonetti OP, Lee PWJ (2002) Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession. Radiology 222:835–842CrossRefPubMed
16.
go back to reference Hansen M, Sørensen T (2013) Gadgetron: an open source framework for medical image reconstruction. Magn Reson Med 69:1768–1776CrossRefPubMed Hansen M, Sørensen T (2013) Gadgetron: an open source framework for medical image reconstruction. Magn Reson Med 69:1768–1776CrossRefPubMed
17.
go back to reference Xue H, Inati S, Sørensen TS, Kellman PHM (2015) Distributed MRI reconstruction using Gadgetron-based cloud computing. Magn Reson Med 73:1015–1025CrossRefPubMed Xue H, Inati S, Sørensen TS, Kellman PHM (2015) Distributed MRI reconstruction using Gadgetron-based cloud computing. Magn Reson Med 73:1015–1025CrossRefPubMed
18.
go back to reference Bland JMAD (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRefPubMed Bland JMAD (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRefPubMed
19.
go back to reference McBride G (2005) A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient. In: NIWA Client Report: HAM 2005-06. Report to Ministry of Health, p 6 McBride G (2005) A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient. In: NIWA Client Report: HAM 2005-06. Report to Ministry of Health, p 6
20.
go back to reference Lin L (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRefPubMed Lin L (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRefPubMed
23.
go back to reference Blalock SE, Banka P, Geva T, Powell AJ, Zhou J, Prakash A (2013) Interstudy variability in cardiac magnetic resonance imaging measurements of ventricular volume, mass, and ejection fraction in repaired tetralogy of Fallot: a prospective observational study. J Magn Reson Imaging 38(4):829–835. https://doi.org/10.1002/jmri.24050 CrossRefPubMed Blalock SE, Banka P, Geva T, Powell AJ, Zhou J, Prakash A (2013) Interstudy variability in cardiac magnetic resonance imaging measurements of ventricular volume, mass, and ejection fraction in repaired tetralogy of Fallot: a prospective observational study. J Magn Reson Imaging 38(4):829–835. https://​doi.​org/​10.​1002/​jmri.​24050 CrossRefPubMed
Metadata
Title
Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging
Authors
Anthony Merlocco
Laura Olivieri
Peter Kellman
Hui Xue
Russell Cross
Publication date
01-01-2019
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 1/2019
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-018-1963-z

Other articles of this Issue 1/2019

Pediatric Cardiology 1/2019 Go to the issue