Skip to main content
Top
Published in: European Radiology 11/2003

01-11-2003 | Magnetic Resonance

Principles and applications of balanced SSFP techniques

Authors: Klaus Scheffler, Stefan Lehnhardt

Published in: European Radiology | Issue 11/2003

Login to get access

Abstract

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.
Literature
2.
go back to reference Carr HY (1958) Steady-state free precession in nuclear magnetic resonance. Phys Rev 112:1693–1701CrossRef Carr HY (1958) Steady-state free precession in nuclear magnetic resonance. Phys Rev 112:1693–1701CrossRef
3.
go back to reference Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a new fast MRI sequence. Electromedica (Engl Ed) 54:15–18 Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a new fast MRI sequence. Electromedica (Engl Ed) 54:15–18
4.
go back to reference Scheffler K (1999) A pictorial description of steady states in fast magnetic resonance imaging: concept. Magn Res 11:291–304 Scheffler K (1999) A pictorial description of steady states in fast magnetic resonance imaging: concept. Magn Res 11:291–304
5.
go back to reference Deimling M, Heid O (1994) Magnetization prepared true FISP imaging. In: Proc Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495 Deimling M, Heid O (1994) Magnetization prepared true FISP imaging. In: Proc Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495
6.
go back to reference Freeman R, Hill HDW (1971) Phase and intensity anomalities in Fourier transform NMR. J Magn Reson 4:366–383 Freeman R, Hill HDW (1971) Phase and intensity anomalities in Fourier transform NMR. J Magn Reson 4:366–383
7.
go back to reference Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:17–193CrossRef Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:17–193CrossRef
8.
go back to reference Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) In: Magnetic resonance imaging: physical principles and sequence design. Mosby, St. Louis, chap. 18 Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) In: Magnetic resonance imaging: physical principles and sequence design. Mosby, St. Louis, chap. 18
9.
go back to reference Scheffler K. Hennig J (2003) Is TrueFISP a spin-echo or gradient-echo sequence? Magn Reson Med 49:395–397CrossRef Scheffler K. Hennig J (2003) Is TrueFISP a spin-echo or gradient-echo sequence? Magn Reson Med 49:395–397CrossRef
10.
go back to reference Schaeffter T, Weiss S, Börnert P (2002) A SAR-reduced steady-state free precessing (SSFP) acquisition. Proc ISMRM, Honolulu, p 2351 Schaeffter T, Weiss S, Börnert P (2002) A SAR-reduced steady-state free precessing (SSFP) acquisition. Proc ISMRM, Honolulu, p 2351
11.
go back to reference Haase A (1990) Snapshot FLASH MRI: applications to T1, T2, and chemical-shift imaging. Magn Reson Med 13:77–89CrossRef Haase A (1990) Snapshot FLASH MRI: applications to T1, T2, and chemical-shift imaging. Magn Reson Med 13:77–89CrossRef
12.
go back to reference Norris D, Börnert P, Reese T, Leibfritz D (1992) On the application of ultra-fast RARE experiments. Magn Reson Med 27:142–164CrossRef Norris D, Börnert P, Reese T, Leibfritz D (1992) On the application of ultra-fast RARE experiments. Magn Reson Med 27:142–164CrossRef
13.
go back to reference Scheffler K, Hennig J (2001) T1 quantification with inversion recovery TrueFISP. Magn Reson Med 45:720–723CrossRef Scheffler K, Hennig J (2001) T1 quantification with inversion recovery TrueFISP. Magn Reson Med 45:720–723CrossRef
14.
go back to reference Scheffler K, Thiel T, Thesen S (2002) Assessment of perfusion with arterial spin labeling and TrueFISP. Proc ISMRM, Honolulu, p 628 Scheffler K, Thiel T, Thesen S (2002) Assessment of perfusion with arterial spin labeling and TrueFISP. Proc ISMRM, Honolulu, p 628
15.
go back to reference Nishimura DG, Vasanawala SS (2000) Analysis and reduction of the transient response in SSFP imaging. Proc 8th Annual Meeting ISMRM, p 301 Nishimura DG, Vasanawala SS (2000) Analysis and reduction of the transient response in SSFP imaging. Proc 8th Annual Meeting ISMRM, p 301
16.
go back to reference Hennig J, Speck O, Scheffler K (2002) Optimization of the signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 48:801–809CrossRef Hennig J, Speck O, Scheffler K (2002) Optimization of the signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 48:801–809CrossRef
17.
go back to reference Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG (2001) Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 46:149–158CrossRef Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG (2001) Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 46:149–158CrossRef
18.
go back to reference Scheffler K, Heid O, Hennig J (2001) Magnetization preparation during the steady state: 3D fat saturated TrueFISP. Magn Reson Med 45:1075–1080CrossRef Scheffler K, Heid O, Hennig J (2001) Magnetization preparation during the steady state: 3D fat saturated TrueFISP. Magn Reson Med 45:1075–1080CrossRef
19.
go back to reference Wagner S, Buser P, Auffermann W, Holt WW, Wolfe CL, Higgins CB (1989) Cine magnetic resonance imaging: tomographic analysis of left ventricular function. Cardiol Clin 7:651–659CrossRef Wagner S, Buser P, Auffermann W, Holt WW, Wolfe CL, Higgins CB (1989) Cine magnetic resonance imaging: tomographic analysis of left ventricular function. Cardiol Clin 7:651–659CrossRef
20.
go back to reference Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269CrossRef Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269CrossRef
21.
go back to reference Jung BA, Hennig J, Scheffler K (2002) Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 48:921–925CrossRef Jung BA, Hennig J, Scheffler K (2002) Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 48:921–925CrossRef
22.
go back to reference Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D (2001) 3D magnetization-prepared TrueFISP: a new technique for imaging coronary arteries. Magn Reson Med 46:494–502CrossRef Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D (2001) 3D magnetization-prepared TrueFISP: a new technique for imaging coronary arteries. Magn Reson Med 46:494–502CrossRef
23.
go back to reference Leupold J,Hennig J, Scheffler K (2002) 3D time-of-flight MRI using inversion recovery TrueFISP. Proc ISMRM, Honolulu, p 138 Leupold J,Hennig J, Scheffler K (2002) 3D time-of-flight MRI using inversion recovery TrueFISP. Proc ISMRM, Honolulu, p 138
24.
go back to reference Scheffler K, Winterer JT, Langer M, Hennig J (2002) Contrast-enhanced angiography using T1-weighted TrueFISP. Proc ISMRM, Honolulu, p 139 Scheffler K, Winterer JT, Langer M, Hennig J (2002) Contrast-enhanced angiography using T1-weighted TrueFISP. Proc ISMRM, Honolulu, p 139
25.
go back to reference Amartur SC, Wielopolski PA, Kormos DW, Modic MT, Clampitt M (1991) Tissue segmentation for three-dimensional display of human spines. Med Phys 18:305–308CrossRef Amartur SC, Wielopolski PA, Kormos DW, Modic MT, Clampitt M (1991) Tissue segmentation for three-dimensional display of human spines. Med Phys 18:305–308CrossRef
26.
go back to reference Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317CrossRef Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317CrossRef
27.
go back to reference Overall WR, Conolly SM, Nishimura DG, Hu BS (2002) Oscillating dual-equilibrium steady-state angiography. Magn Reson Med 47:513–522CrossRef Overall WR, Conolly SM, Nishimura DG, Hu BS (2002) Oscillating dual-equilibrium steady-state angiography. Magn Reson Med 47:513–522CrossRef
28.
go back to reference Vasanawala SS, Pauly JM, Nishimura DG (2000) Linear combination steady-state free precession MRI. Magn Reson Med 43:82–90CrossRef Vasanawala SS, Pauly JM, Nishimura DG (2000) Linear combination steady-state free precession MRI. Magn Reson Med 43:82–90CrossRef
29.
go back to reference Hardy CJ, Dixon WT (2002) Steady-state free precession imaging with inherent fat suppression. Proc ISMRM, Honolulu, p 473 Hardy CJ, Dixon WT (2002) Steady-state free precession imaging with inherent fat suppression. Proc ISMRM, Honolulu, p 473
30.
go back to reference Petsch R, Helmberger T, Reiser M (1999) New techniques and pulse sequences in MRI of the liver. Radiologe 39:662–670CrossRef Petsch R, Helmberger T, Reiser M (1999) New techniques and pulse sequences in MRI of the liver. Radiologe 39:662–670CrossRef
31.
go back to reference Herborn CU, Vogt F, Lauenstein TC, Goyen M, Debatin JF, Ruehm SG (2003) MRI of the liver: Can TrueFISP replace HASTE? J Magn Reson Med 17:190–196 Herborn CU, Vogt F, Lauenstein TC, Goyen M, Debatin JF, Ruehm SG (2003) MRI of the liver: Can TrueFISP replace HASTE? J Magn Reson Med 17:190–196
32.
go back to reference Rieber A, Aschoff A, Brambs HJ (2000) MRI in the diagnosis of small bowel disease: use of positive and negative oral contrast media in combination with enteroclysis. Eur Radiol 10:1377–1382CrossRef Rieber A, Aschoff A, Brambs HJ (2000) MRI in the diagnosis of small bowel disease: use of positive and negative oral contrast media in combination with enteroclysis. Eur Radiol 10:1377–1382CrossRef
Metadata
Title
Principles and applications of balanced SSFP techniques
Authors
Klaus Scheffler
Stefan Lehnhardt
Publication date
01-11-2003
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 11/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1957-x

Other articles of this Issue 11/2003

European Radiology 11/2003 Go to the issue