Abstract

This review summarizes the state-of-the-art in electrical impedance tomography (EIT) for ventilation and perfusion imaging. EIT is a relatively new technology used to image regional impedance distributions in a cross-sectional area of the body. After the introduction, a brief overview of the recent history is provided followed by a review of the literature on regional ventilation monitoring using EIT. Several recently presented indices that are useful to extract information from EIT image streams are described. Selected experimental and clinical findings are discussed with respect to future routine applications in intensive care. Finally, past and ongoing research activities aimed at obtaining cardiac output and regional perfusion information from EIT image streams are summarized.
Appendix
Available only for authorised users
Literature
1.
go back to reference Arnold JH (2004) Electrical impedance tomography: on the path to the holy grail. Crit Care Med 32:894–895PubMedCrossRef Arnold JH (2004) Electrical impedance tomography: on the path to the holy grail. Crit Care Med 32:894–895PubMedCrossRef
2.
go back to reference Bodenstein M, David M, Markstaller K (2009) Principles of electrical impedance tomography and its clinical application. Crit Care Med 37:713–724PubMedCrossRef Bodenstein M, David M, Markstaller K (2009) Principles of electrical impedance tomography and its clinical application. Crit Care Med 37:713–724PubMedCrossRef
3.
4.
go back to reference Muders T, Luepschen H, Putensen C (2010) Impedance tomography as a new monitoring technique. Curr Opin Crit Care 16:269–275PubMedCrossRef Muders T, Luepschen H, Putensen C (2010) Impedance tomography as a new monitoring technique. Curr Opin Crit Care 16:269–275PubMedCrossRef
5.
go back to reference Moerer O, Hahn G, Quintel M (2011) Lung impedance measurements to monitor alveolar ventilation. Curr Opin Crit Care 17:260–267PubMedCrossRef Moerer O, Hahn G, Quintel M (2011) Lung impedance measurements to monitor alveolar ventilation. Curr Opin Crit Care 17:260–267PubMedCrossRef
6.
go back to reference Putensen C, Wrigge H, Zinserling J (2007) Electrical impedance tomography guided ventilation therapy. Curr Opin Crit Care 13:344–350PubMedCrossRef Putensen C, Wrigge H, Zinserling J (2007) Electrical impedance tomography guided ventilation therapy. Curr Opin Crit Care 13:344–350PubMedCrossRef
7.
go back to reference Domenighetti G, Maggiorini M (2010) Electrical impedance tomography to guide ventilation in ALI-ARDS patients: a research tool for zealous physiologists or an imminent support for the real world intensivist? Minerva Anestesiol 76:986–988PubMed Domenighetti G, Maggiorini M (2010) Electrical impedance tomography to guide ventilation in ALI-ARDS patients: a research tool for zealous physiologists or an imminent support for the real world intensivist? Minerva Anestesiol 76:986–988PubMed
8.
go back to reference Frerichs I, Weiler N (2012) Electrical impedance tomography: the next game level. Crit Care Med 40:1015–1016PubMedCrossRef Frerichs I, Weiler N (2012) Electrical impedance tomography: the next game level. Crit Care Med 40:1015–1016PubMedCrossRef
9.
go back to reference Avis NJ, Barber DC (1994) Image reconstruction using non-adjacent drive configurations. Physiol Meas 15(Suppl 2a):153–160CrossRef Avis NJ, Barber DC (1994) Image reconstruction using non-adjacent drive configurations. Physiol Meas 15(Suppl 2a):153–160CrossRef
10.
go back to reference Malmivuo J, Plonsey R (1995) Bioelectromagnetism—principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New YorkCrossRef Malmivuo J, Plonsey R (1995) Bioelectromagnetism—principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New YorkCrossRef
11.
12.
13.
go back to reference Hahn G, Sipinkov I, Baisch F, Hellige G (1995) Changes in the thoracic impedance distribution under different ventilatory conditions. Physiol Meas 16:161–173CrossRef Hahn G, Sipinkov I, Baisch F, Hellige G (1995) Changes in the thoracic impedance distribution under different ventilatory conditions. Physiol Meas 16:161–173CrossRef
14.
go back to reference Calzia E, Hahn G, Hellige G (2005) Electrical impedance tomography: looking behind the secrets of regional lung function. Intensive Care Med 31:1474–1475PubMedCrossRef Calzia E, Hahn G, Hellige G (2005) Electrical impedance tomography: looking behind the secrets of regional lung function. Intensive Care Med 31:1474–1475PubMedCrossRef
15.
go back to reference Adler A, Arnold JH, Bayford R, Borsic A, Brown B, Dixon P, Faes TJ, Frerichs I, Gagnon H, Gärber Y, Grychtol B, Hahn G, Lionheart WR, Malik A, Patterson RP, Stocks J, Tizzard A, Weiler N, Wolf GK (2009) GREIT: a unified approach to 2D linear EIT reconstruction of lung images. Physiol Meas 30:S35–S55PubMedCrossRef Adler A, Arnold JH, Bayford R, Borsic A, Brown B, Dixon P, Faes TJ, Frerichs I, Gagnon H, Gärber Y, Grychtol B, Hahn G, Lionheart WR, Malik A, Patterson RP, Stocks J, Tizzard A, Weiler N, Wolf GK (2009) GREIT: a unified approach to 2D linear EIT reconstruction of lung images. Physiol Meas 30:S35–S55PubMedCrossRef
16.
go back to reference Frerichs I, Hahn G, Hellige G (1999) Thoracic electrical impedance tomographic measurements during volume controlled ventilation—effects of tidal volume and positive end-expiratory pressure. IEEE Trans Med Imaging 18:764–773PubMedCrossRef Frerichs I, Hahn G, Hellige G (1999) Thoracic electrical impedance tomographic measurements during volume controlled ventilation—effects of tidal volume and positive end-expiratory pressure. IEEE Trans Med Imaging 18:764–773PubMedCrossRef
17.
go back to reference Meier T, Leibecke T, Eckmann C, Gosch UW, Grossherr M, Bruch HP, Gehring H, Leonhardt S (2006) Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model. Langenbecks Arch Surg 391:383–389PubMedCrossRef Meier T, Leibecke T, Eckmann C, Gosch UW, Grossherr M, Bruch HP, Gehring H, Leonhardt S (2006) Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model. Langenbecks Arch Surg 391:383–389PubMedCrossRef
18.
go back to reference Adler A, Amyot R, Guardo R, Bates JH, Berthiaume Y (1997) Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 83:1762–1767PubMed Adler A, Amyot R, Guardo R, Bates JH, Berthiaume Y (1997) Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 83:1762–1767PubMed
19.
go back to reference Marquis F, Coulombe N, Costa R, Gagnon H, Guardo R, Skrobik Y (2006) Electrical impedance tomography’s correlation to lung volume is not influenced by anthropometric parameters. J Clin Monit Comput 20:201–207PubMedCrossRef Marquis F, Coulombe N, Costa R, Gagnon H, Guardo R, Skrobik Y (2006) Electrical impedance tomography’s correlation to lung volume is not influenced by anthropometric parameters. J Clin Monit Comput 20:201–207PubMedCrossRef
20.
go back to reference Hinz J, Hahn G, Neumann P, Sydow M, Mohrenweiser P, Hellige G, Burchardi H (2003) End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change. Intensive Care Med 29:37–43PubMed Hinz J, Hahn G, Neumann P, Sydow M, Mohrenweiser P, Hellige G, Burchardi H (2003) End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change. Intensive Care Med 29:37–43PubMed
21.
go back to reference Odenstedt H, Lindgren S, Olegrd C, Erlandsson K, Lethvall S, Aneman A, Stenqvist O, Lundin S (2005) Slow moderate pressure recruitment maneuver minimizes negative circulatory and lung mechanic side effects: evaluation of recruitment maneuvers using electric impedance tomography. Intensive Care Med 31:1706–1714PubMedCrossRef Odenstedt H, Lindgren S, Olegrd C, Erlandsson K, Lethvall S, Aneman A, Stenqvist O, Lundin S (2005) Slow moderate pressure recruitment maneuver minimizes negative circulatory and lung mechanic side effects: evaluation of recruitment maneuvers using electric impedance tomography. Intensive Care Med 31:1706–1714PubMedCrossRef
22.
go back to reference Grivans C, Lundin S, Stenqvist O, Lindgren S (2011) Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography. Acta Anaesthesiol Scand 55:1068–1077PubMedCrossRef Grivans C, Lundin S, Stenqvist O, Lindgren S (2011) Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography. Acta Anaesthesiol Scand 55:1068–1077PubMedCrossRef
23.
go back to reference Bikker IG, Leonhardt S, Bakker J, Gommers D (2009) Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels. Intensive Care Med 35:1362–1367PubMedCrossRef Bikker IG, Leonhardt S, Bakker J, Gommers D (2009) Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels. Intensive Care Med 35:1362–1367PubMedCrossRef
24.
go back to reference Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M, Hellige G (2002) Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Trans Med Imaging 21:646–652PubMedCrossRef Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M, Hellige G (2002) Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Trans Med Imaging 21:646–652PubMedCrossRef
25.
go back to reference Victorino JA, Borges JB, Okamoto VN, Matos GF, Tucci MR, Caramez MP, Tanaka H, Sipmann FS, Santos DC, Barbas CS, Carvalho CR, Amato MB (2004) Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 169:791–800PubMedCrossRef Victorino JA, Borges JB, Okamoto VN, Matos GF, Tucci MR, Caramez MP, Tanaka H, Sipmann FS, Santos DC, Barbas CS, Carvalho CR, Amato MB (2004) Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 169:791–800PubMedCrossRef
26.
go back to reference Wrigge H, Zinserling J, Muders T, Varelmann D, Gnther U, von der Groeben C, Magnusson A, Hedenstierna G, Putensen C (2008) Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury. Crit Care Med 36:903–909PubMedCrossRef Wrigge H, Zinserling J, Muders T, Varelmann D, Gnther U, von der Groeben C, Magnusson A, Hedenstierna G, Putensen C (2008) Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury. Crit Care Med 36:903–909PubMedCrossRef
27.
go back to reference Hinz J, Neumann P, Dudykevych T, Andersson LG, Wrigge H, Burchardi H, Hedenstierna G (2003) Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 124:314–322PubMedCrossRef Hinz J, Neumann P, Dudykevych T, Andersson LG, Wrigge H, Burchardi H, Hedenstierna G (2003) Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 124:314–322PubMedCrossRef
28.
go back to reference Richard JC, Pouzot C, Gros A, Tourevieille C, Lebars D, Lavenne F, Frerichs I, Gurin C (2009) Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study. Crit Care 13:R82PubMedCrossRef Richard JC, Pouzot C, Gros A, Tourevieille C, Lebars D, Lavenne F, Frerichs I, Gurin C (2009) Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study. Crit Care 13:R82PubMedCrossRef
29.
go back to reference Luepschen H, Meier T, Grossherr M, Leibecke T, Karsten J, Leonhardt S (2007) Protective ventilation using electrical impedance tomography. Physiol Meas 28:247–260CrossRef Luepschen H, Meier T, Grossherr M, Leibecke T, Karsten J, Leonhardt S (2007) Protective ventilation using electrical impedance tomography. Physiol Meas 28:247–260CrossRef
30.
go back to reference Meier T, Luepschen H, Karsten J, Leibecke T, Grossherr M, Gehring H, Leonhardt S (2008) Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Intensive Care Med 34:543–550PubMedCrossRef Meier T, Luepschen H, Karsten J, Leibecke T, Grossherr M, Gehring H, Leonhardt S (2008) Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Intensive Care Med 34:543–550PubMedCrossRef
32.
go back to reference Bikker IG, Leonhardt S, Reis Miranda D, Bakker J, Gommers D (2010) Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients. Crit Care 14:R100PubMedCrossRef Bikker IG, Leonhardt S, Reis Miranda D, Bakker J, Gommers D (2010) Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients. Crit Care 14:R100PubMedCrossRef
33.
go back to reference Kunst PW, Vazquez de Anda G, Bhm SH, Faes TJ, Lachmann B, Postmus PE, de Vries PM (2000) Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:3891–3895PubMedCrossRef Kunst PW, Vazquez de Anda G, Bhm SH, Faes TJ, Lachmann B, Postmus PE, de Vries PM (2000) Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:3891–3895PubMedCrossRef
34.
go back to reference Frerichs I, Hahn G, Golisch W, Kurpitz M, Burchardi H, Hellige G (1998) Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography. Acta Anaesthesiol Scand 42:721–726PubMedCrossRef Frerichs I, Hahn G, Golisch W, Kurpitz M, Burchardi H, Hellige G (1998) Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography. Acta Anaesthesiol Scand 42:721–726PubMedCrossRef
35.
go back to reference Muders T, Luepschen H, Zinserling J, Greschus S, Fimmers R, Guenther U, Buchwald M, Grigutsch D, Leonhardt S, Putensen C, Wrigge H (2012) Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury. Crit Care Med 40:903–911PubMedCrossRef Muders T, Luepschen H, Zinserling J, Greschus S, Fimmers R, Guenther U, Buchwald M, Grigutsch D, Leonhardt S, Putensen C, Wrigge H (2012) Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury. Crit Care Med 40:903–911PubMedCrossRef
36.
go back to reference Zhao Z, Moller K, Steinmann D, Frerichs I, Guttmann J (2009) Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution. Intensive Care Med 35:1900–1906PubMedCrossRef Zhao Z, Moller K, Steinmann D, Frerichs I, Guttmann J (2009) Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution. Intensive Care Med 35:1900–1906PubMedCrossRef
37.
go back to reference Zhao Z, Steinmann D, Frerichs I, Guttmann J, Moller K (2010) PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography. Crit Care 14:R8PubMedCrossRef Zhao Z, Steinmann D, Frerichs I, Guttmann J, Moller K (2010) PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography. Crit Care 14:R8PubMedCrossRef
38.
go back to reference Costa EL, Borges JB, Melo A, Suarez-Sipmann F, Toufen C Jr, Bohm SH, Amato MB (2009) Bedside estimation of recruitable alveolar collapse and hyper-distension by electrical impedance tomography. Intensive Care Med 35:1132–1137PubMedCrossRef Costa EL, Borges JB, Melo A, Suarez-Sipmann F, Toufen C Jr, Bohm SH, Amato MB (2009) Bedside estimation of recruitable alveolar collapse and hyper-distension by electrical impedance tomography. Intensive Care Med 35:1132–1137PubMedCrossRef
39.
go back to reference Gómez-Laberge C, Arnold JH, Wolf GK (2012) A unified approach for EIT imaging of regional overdistension and atelectasis in acute lung injury. IEEE Trans Med Imaging 31:834–842PubMedCrossRef Gómez-Laberge C, Arnold JH, Wolf GK (2012) A unified approach for EIT imaging of regional overdistension and atelectasis in acute lung injury. IEEE Trans Med Imaging 31:834–842PubMedCrossRef
40.
go back to reference Lindgren S, Odenstedt H, Erlandsson K, Grivans C, Lundin S, Stenqvist O (2008) Bronchoscopic suctioning may cause lung collapse: a lung model and clinical evaluation. Acta Anaesthesiol Scand 52:209–218PubMedCrossRef Lindgren S, Odenstedt H, Erlandsson K, Grivans C, Lundin S, Stenqvist O (2008) Bronchoscopic suctioning may cause lung collapse: a lung model and clinical evaluation. Acta Anaesthesiol Scand 52:209–218PubMedCrossRef
41.
go back to reference Lindgren S, Odenstedt H, Olegrd C, Sondergaard S, Lundin S, Stenqvist O (2007) Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: a study using electric impedance tomography. Intensive Care Med 33:172–180PubMedCrossRef Lindgren S, Odenstedt H, Olegrd C, Sondergaard S, Lundin S, Stenqvist O (2007) Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: a study using electric impedance tomography. Intensive Care Med 33:172–180PubMedCrossRef
42.
go back to reference Wolf GK, Grychtol B, Frerichs I, van Genderingen HR, Zurakowski D, Thompson JE, Arnold JH (2007) Regional lung volume changes in children with acute respiratory distress syndrome during a derecruitment maneuver. Crit Care Med 35:1972–1978PubMedCrossRef Wolf GK, Grychtol B, Frerichs I, van Genderingen HR, Zurakowski D, Thompson JE, Arnold JH (2007) Regional lung volume changes in children with acute respiratory distress syndrome during a derecruitment maneuver. Crit Care Med 35:1972–1978PubMedCrossRef
43.
go back to reference Tingay DG, Copnell B, Grant CA, Dargaville PA, Dunster KR, Schibler A (2010) The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume. Intensive Care Med 36:888–896PubMedCrossRef Tingay DG, Copnell B, Grant CA, Dargaville PA, Dunster KR, Schibler A (2010) The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume. Intensive Care Med 36:888–896PubMedCrossRef
44.
go back to reference van Veenendaal MB, Miedema M, de Jongh FH, van der Lee JH, Frerichs I, van Kaam AH (2009) Effect of closed endotracheal suction in high frequency ventilated premature infants measured with electrical impedance tomography. Intensive Care Med 35:2130–2134PubMedCrossRef van Veenendaal MB, Miedema M, de Jongh FH, van der Lee JH, Frerichs I, van Kaam AH (2009) Effect of closed endotracheal suction in high frequency ventilated premature infants measured with electrical impedance tomography. Intensive Care Med 35:2130–2134PubMedCrossRef
45.
go back to reference Steinmann D, Stahl CA, Minner J, Schumann S, Loop T, Kirschbaum A, Priebe HJ, Guttmann J (2008) Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study. Br J Anaesth 101:411–418PubMedCrossRef Steinmann D, Stahl CA, Minner J, Schumann S, Loop T, Kirschbaum A, Priebe HJ, Guttmann J (2008) Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study. Br J Anaesth 101:411–418PubMedCrossRef
46.
go back to reference Gattinoni L, Pesenti A, Avalli L, Rossi F, Bombino M (1987) Pressure-volume curve of total respiratory system in acute respiratory failure. Computed tomographic scan study. Am Rev Respir Dis 136:730–736PubMedCrossRef Gattinoni L, Pesenti A, Avalli L, Rossi F, Bombino M (1987) Pressure-volume curve of total respiratory system in acute respiratory failure. Computed tomographic scan study. Am Rev Respir Dis 136:730–736PubMedCrossRef
47.
go back to reference Pelosi P, D’Andrea L, Vitale G, Pesenti A, Gattinoni L (1994) Vertical gradient of regional lung inflation in adult respiratory distress syndrome. Am J Respir Crit Care Med 149:8–13PubMed Pelosi P, D’Andrea L, Vitale G, Pesenti A, Gattinoni L (1994) Vertical gradient of regional lung inflation in adult respiratory distress syndrome. Am J Respir Crit Care Med 149:8–13PubMed
48.
go back to reference Kunst PW, Bohm SH, Vazquez de Anda G, Amato MB, Lachmann B, Postmus PE, de Vries PM (2000) Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:178–183PubMedCrossRef Kunst PW, Bohm SH, Vazquez de Anda G, Amato MB, Lachmann B, Postmus PE, de Vries PM (2000) Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:178–183PubMedCrossRef
49.
go back to reference Hinz J, Moerer O, Neumann P, Dudykevych T, Frerichs I, Hellige G, Quintel M (2006) Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography. Acta Anaesthesiol Scand 50:331–339PubMedCrossRef Hinz J, Moerer O, Neumann P, Dudykevych T, Frerichs I, Hellige G, Quintel M (2006) Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography. Acta Anaesthesiol Scand 50:331–339PubMedCrossRef
50.
go back to reference Grychtol B, Wolf GK, Arnold JH (2009) Differences in regional pulmonary pressure impedance curves before and after lung injury assessed with a novel algorithm. Physiol Meas 30:137–148CrossRef Grychtol B, Wolf GK, Arnold JH (2009) Differences in regional pulmonary pressure impedance curves before and after lung injury assessed with a novel algorithm. Physiol Meas 30:137–148CrossRef
51.
go back to reference van Genderingen HR, van Vught AJ, Jansen JR (2004) Regional lung volume during high-frequency oscillatory ventilation by electrical impedance tomography. Crit Care Med 32:787–794PubMedCrossRef van Genderingen HR, van Vught AJ, Jansen JR (2004) Regional lung volume during high-frequency oscillatory ventilation by electrical impedance tomography. Crit Care Med 32:787–794PubMedCrossRef
52.
go back to reference Dargaville PA, Rimensberger PC, Frerichs I (2010) Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre. Intensive Care Med 36:1953–1961PubMedCrossRef Dargaville PA, Rimensberger PC, Frerichs I (2010) Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre. Intensive Care Med 36:1953–1961PubMedCrossRef
53.
go back to reference Lowhagen K, Lundin S, Stenqvist O (2011) Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome—assessed by electric impedance tomography. Minerva Anestesiol 76:1024–1035 Lowhagen K, Lundin S, Stenqvist O (2011) Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome—assessed by electric impedance tomography. Minerva Anestesiol 76:1024–1035
54.
go back to reference Costa EL, Chaves CN, Gomes S, Beraldo MA, Volpe MS, Tucci MR, Schettino IA, Bohm SH, Carvalho CR, Tanaka H, Lima RG, Amato MB (2008) Real-time detection of pneumothorax using electrical impedance tomography. Crit Care Med 36:1230–1238PubMedCrossRef Costa EL, Chaves CN, Gomes S, Beraldo MA, Volpe MS, Tucci MR, Schettino IA, Bohm SH, Carvalho CR, Tanaka H, Lima RG, Amato MB (2008) Real-time detection of pneumothorax using electrical impedance tomography. Crit Care Med 36:1230–1238PubMedCrossRef
55.
go back to reference Preis C, Luepschen H, Leonhardt S, Gommers D (2009) Experimental case report: development of a pneumothorax monitored by electrical impedance tomography. Clin Physiol Funct Imaging 29:159–162PubMedCrossRef Preis C, Luepschen H, Leonhardt S, Gommers D (2009) Experimental case report: development of a pneumothorax monitored by electrical impedance tomography. Clin Physiol Funct Imaging 29:159–162PubMedCrossRef
56.
go back to reference Kunst PW, Vonk Noordegraaf A, Raaijmakers E, Bakker J, Groeneveld AB, Postmus PE, de Vries PM (1999) Electrical impedance tomography in the assessment of extravascular lung water in noncardiogenic acute respiratory failure. Chest 116:1695–1702PubMedCrossRef Kunst PW, Vonk Noordegraaf A, Raaijmakers E, Bakker J, Groeneveld AB, Postmus PE, de Vries PM (1999) Electrical impedance tomography in the assessment of extravascular lung water in noncardiogenic acute respiratory failure. Chest 116:1695–1702PubMedCrossRef
57.
go back to reference Arad M, Zlochiver S, Davidson T, Shoenfeld Y, Adunsky A, Abboud S (2009) The detection of pleural effusion using a parametric EIT technique. Physiol Meas 30:421–428PubMedCrossRef Arad M, Zlochiver S, Davidson T, Shoenfeld Y, Adunsky A, Abboud S (2009) The detection of pleural effusion using a parametric EIT technique. Physiol Meas 30:421–428PubMedCrossRef
58.
go back to reference Lachmann B, Robertson B, Vogel J (1980) In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand 24:231–236PubMedCrossRef Lachmann B, Robertson B, Vogel J (1980) In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand 24:231–236PubMedCrossRef
59.
go back to reference Kunst PW, de Vries PM, Postmus PE, Bakker J (1999) Evaluation of electrical impedance tomography in the measurement of PEEP-induced changes in lung volume. Chest 115:1102–1106PubMedCrossRef Kunst PW, de Vries PM, Postmus PE, Bakker J (1999) Evaluation of electrical impedance tomography in the measurement of PEEP-induced changes in lung volume. Chest 115:1102–1106PubMedCrossRef
60.
go back to reference Hinz J, Moerer O, Neumann P, Dudykevych T, Hellige G, Quintel M (2005) Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography. Eur J Anaesthesiol 22:817–825PubMedCrossRef Hinz J, Moerer O, Neumann P, Dudykevych T, Hellige G, Quintel M (2005) Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography. Eur J Anaesthesiol 22:817–825PubMedCrossRef
61.
go back to reference Lowhagen K, Lindgren S, Odenstedt H, Stenqvist O, Lundin S (2011) A new nonradiological method to assess potential lung recruitability: a pilot study in ALI patients. Acta Anaesthesiol Scand 55:165–174PubMedCrossRef Lowhagen K, Lindgren S, Odenstedt H, Stenqvist O, Lundin S (2011) A new nonradiological method to assess potential lung recruitability: a pilot study in ALI patients. Acta Anaesthesiol Scand 55:165–174PubMedCrossRef
62.
go back to reference Wolf GK, Grychtol B, Frerichs I, Zurakowski D, Arnold JH (2010) Regional lung volume changes during high-frequency oscillatory ventilation. Pediatr Crit Care Med 11:610–615PubMedCrossRef Wolf GK, Grychtol B, Frerichs I, Zurakowski D, Arnold JH (2010) Regional lung volume changes during high-frequency oscillatory ventilation. Pediatr Crit Care Med 11:610–615PubMedCrossRef
63.
go back to reference Vonk Noordegraaf A, Faes TJ, Marcus JT, Janse A, Heethaar RM, Postmus PE, de Vries PM (1996) Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration. Physiol Meas 17:179–188PubMedCrossRef Vonk Noordegraaf A, Faes TJ, Marcus JT, Janse A, Heethaar RM, Postmus PE, de Vries PM (1996) Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration. Physiol Meas 17:179–188PubMedCrossRef
64.
go back to reference Smit HJ, Vonk Noordegraaf A, Marcus JT, Boonstra A, de Vries PM, Postmus PE (2004) Determinants of pulmonary perfusion measured by electrical impedance tomography. Eur J Appl Physiol 92:45–49PubMedCrossRef Smit HJ, Vonk Noordegraaf A, Marcus JT, Boonstra A, de Vries PM, Postmus PE (2004) Determinants of pulmonary perfusion measured by electrical impedance tomography. Eur J Appl Physiol 92:45–49PubMedCrossRef
65.
go back to reference Smit HJ, Vonk-Noordegraaf A, Boonstra A, de Vries PM, Postmus PE (2006) Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography. Respiration 73:597–602PubMedCrossRef Smit HJ, Vonk-Noordegraaf A, Boonstra A, de Vries PM, Postmus PE (2006) Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography. Respiration 73:597–602PubMedCrossRef
66.
go back to reference Zadehkoochak M, Blott BH, Hames TK, George RF (1992) Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT images. Clin Phys Meas 13:191–196CrossRef Zadehkoochak M, Blott BH, Hames TK, George RF (1992) Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT images. Clin Phys Meas 13:191–196CrossRef
67.
go back to reference Leathard AD, Brown BH, Campbell J, Zhang F, Morice AH, Tayler D (1994) A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli. Physiol Meas 15:137–146CrossRef Leathard AD, Brown BH, Campbell J, Zhang F, Morice AH, Tayler D (1994) A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli. Physiol Meas 15:137–146CrossRef
68.
go back to reference Frerichs I, Pulletz S, Elke G, Reifferscheid F, Schadler D, Scholz J, Weiler N (2009) Assessment of changes in distribution of lung perfusion by electrical impedance tomography. Respiration 77:282–291PubMedCrossRef Frerichs I, Pulletz S, Elke G, Reifferscheid F, Schadler D, Scholz J, Weiler N (2009) Assessment of changes in distribution of lung perfusion by electrical impedance tomography. Respiration 77:282–291PubMedCrossRef
69.
go back to reference Carlisle HR, Armstrong RK, Davis PG, Schibler A, Frerichs I, Tingay DG (2010) Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation. Intensive Care Med 36:2101–2108PubMedCrossRef Carlisle HR, Armstrong RK, Davis PG, Schibler A, Frerichs I, Tingay DG (2010) Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation. Intensive Care Med 36:2101–2108PubMedCrossRef
70.
go back to reference Eyueboglu B, Brown B (1988) Methods of cardiac gating applied potential tomography. Clin Phys Meas 9:43–48CrossRef Eyueboglu B, Brown B (1988) Methods of cardiac gating applied potential tomography. Clin Phys Meas 9:43–48CrossRef
71.
go back to reference Vonk Noordegraaf A, Kunst PW, Janse A, Marcus JT, Postmus PE, Faes TJ, de Vries PM (1998) Pulmonary perfusion measured by means of electrical impedance tomography. Physiol Meas 19:263–273PubMedCrossRef Vonk Noordegraaf A, Kunst PW, Janse A, Marcus JT, Postmus PE, Faes TJ, de Vries PM (1998) Pulmonary perfusion measured by means of electrical impedance tomography. Physiol Meas 19:263–273PubMedCrossRef
72.
go back to reference Smit HJ, Handoko ML, Vonk Noordegraaf A, Faes TJ, Postmus PE, de Vries PM, Boonstra A (2003) Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? Physiol Meas 24:491–499PubMedCrossRef Smit HJ, Handoko ML, Vonk Noordegraaf A, Faes TJ, Postmus PE, de Vries PM, Boonstra A (2003) Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? Physiol Meas 24:491–499PubMedCrossRef
73.
go back to reference Vonk-Noordegraaf A, van Wolferen SA, Marcus JT, Boonstra A, Postmus PE, Peeters JW, Peacock AJ (2005) Noninvasive assessment and monitoring of pulmonary circulation. Europ Respir J 25:758–766CrossRef Vonk-Noordegraaf A, van Wolferen SA, Marcus JT, Boonstra A, Postmus PE, Peeters JW, Peacock AJ (2005) Noninvasive assessment and monitoring of pulmonary circulation. Europ Respir J 25:758–766CrossRef
74.
go back to reference Fagerberg A, Stenqvist O, Aneman A (2009) Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 53:152–158PubMedCrossRef Fagerberg A, Stenqvist O, Aneman A (2009) Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 53:152–158PubMedCrossRef
75.
go back to reference Fagerberg A, Stenqvist O, Aneman A (2009) Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model. Crit Care 13:R34PubMedCrossRef Fagerberg A, Stenqvist O, Aneman A (2009) Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model. Crit Care 13:R34PubMedCrossRef
76.
go back to reference Luepschen H, Muders T, Pikkemaat R, Meier T, Putensen C, Leonhardt S (2010) Bestimmung der Lungenperfusion mittels Elektrischer Impedanztomographie. Rostock, Germany, pp 5–8 (in German) Luepschen H, Muders T, Pikkemaat R, Meier T, Putensen C, Leonhardt S (2010) Bestimmung der Lungenperfusion mittels Elektrischer Impedanztomographie. Rostock, Germany, pp 5–8 (in German)
77.
go back to reference Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandstrom M, Park M, Costa EL, Hedenstierna G, Amato M (2012) Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol 112:225–236PubMedCrossRef Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandstrom M, Park M, Costa EL, Hedenstierna G, Amato M (2012) Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol 112:225–236PubMedCrossRef
78.
go back to reference Deibele J, Luepschen H, Leonhardt S (2008) Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Physiol Meas 29:1–14CrossRef Deibele J, Luepschen H, Leonhardt S (2008) Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Physiol Meas 29:1–14CrossRef
79.
go back to reference Kerrouche N, McLeod C, Lionheart W (2001) Time series of EIT chest images using singular value decomposition and Fourier transform. Physiol Meas 22:147–157PubMedCrossRef Kerrouche N, McLeod C, Lionheart W (2001) Time series of EIT chest images using singular value decomposition and Fourier transform. Physiol Meas 22:147–157PubMedCrossRef
80.
go back to reference Li J (2000) Multifrequente Impedanztomographie zur Darstellung der elektrischen Impedanzverteilung im menschlichen Thorax. Dissertation, University of Stuttgart, Germany (in German) Li J (2000) Multifrequente Impedanztomographie zur Darstellung der elektrischen Impedanzverteilung im menschlichen Thorax. Dissertation, University of Stuttgart, Germany (in German)
81.
go back to reference Hahn G, Thiel F, Dudykevych T, Frerichs I, Gersing E, Schroder T, Hartung C, Hellige G (2001) Quantitative evaluation of the performance of different electrical tomography devices. Biomed Tech 46:91–95CrossRef Hahn G, Thiel F, Dudykevych T, Frerichs I, Gersing E, Schroder T, Hartung C, Hellige G (2001) Quantitative evaluation of the performance of different electrical tomography devices. Biomed Tech 46:91–95CrossRef
82.
go back to reference Metherall P, Barber DC, Smallwood RH, Brown BH (1996) Three dimensional electrical impedance tomography. Nature 380:509–512PubMedCrossRef Metherall P, Barber DC, Smallwood RH, Brown BH (1996) Three dimensional electrical impedance tomography. Nature 380:509–512PubMedCrossRef
83.
go back to reference Bikker IG, Preis C, Egal M, Bakker J, Gommers D (2011) Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial. Crit Care 15:R193PubMedCrossRef Bikker IG, Preis C, Egal M, Bakker J, Gommers D (2011) Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial. Crit Care 15:R193PubMedCrossRef
84.
go back to reference Hahn G, Just A, Dudykevych T, Frerichs I, Hinz J, Quintel M, Hellige G (2006) Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT. Physiol Meas 27:187–198CrossRef Hahn G, Just A, Dudykevych T, Frerichs I, Hinz J, Quintel M, Hellige G (2006) Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT. Physiol Meas 27:187–198CrossRef
85.
go back to reference Denai MA, Mahfouf M, Mohamad-Samuri S, Panoutsos G, Brown BH, Mills GH (2010) Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends. IEEE Trans Inf Technol Biomed 14:641–649PubMedCrossRef Denai MA, Mahfouf M, Mohamad-Samuri S, Panoutsos G, Brown BH, Mills GH (2010) Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends. IEEE Trans Inf Technol Biomed 14:641–649PubMedCrossRef
Metadata
Title
Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?
Authors
Steffen Leonhardt
Burkhard Lachmann
Publication date
01-12-2012
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 12/2012
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-012-2684-z

Other articles of this Issue 12/2012

Intensive Care Medicine 12/2012 Go to the issue