Skip to main content
Top
Published in: Updates in Surgery 3/2021

01-06-2021 | Computed Tomography | Original Article

Robotic assistance for quick and accurate image-guided needle placement

Authors: Abigail J. Fong, Camille L. Stewart, Kelly Lafaro, Christopher J. LaRocca, Yuman Fong, Joseph D. Femino, Brooke Crawford

Published in: Updates in Surgery | Issue 3/2021

Login to get access

Abstract

Computed tomography (CT) image-guided procedures including biopsy, drug delivery, and ablation are gaining increasing application in medicine. Robotic technology holds the promise for allowing surgeons, and other proceduralists, access to such CT-guided procedures by potentially shortening training, improving accuracy, decreasing needle passes, and reducing radiation exposure. We evaluated surgeon learning and proficiency for image-guided needle placement with an FDA-cleared robotic arm. Five out of six surgeons had no prior CT-guided procedural experience, while one had prior experience with freehand CT-guided needle placement. All surgeons underwent a 60-min training with the MAXIO robot (Perfint Healthcare, Redmond, WA). The robot was used to place needles into three different pre-specified targets on a spine model. Performance time, procedural errors, and needle placement accuracy were recorded. All participants successfully placed needles into the targets using the robotic arm. The average time for needle placement was 3:44 ± 1:43 min. Time for needle placement decreased with subsequent attempts, with average third placement taking 2:29 ± 1:51 min less than the first attempt. The average vector distance from the target was 2.3 ± 1.2 mm. One error resulted in the need for reimaging by CT scan. No errant needle placement occurred. Surgeons (attending fellows and residents) without previous experience and minimal training could successfully place percutaneous needles under CT guidance quickly, accurately, and reproducibly using a robotic arm. This suggests that robotic technology may be used to facilitate surgeon adoption of CT image-guided needle-based procedures in the future.
Literature
5.
go back to reference Cornelis F, Takaki H, Laskhmanan M, Durack JC, Erinjeri JP, Getrajdman GI, Maybody M, Sofocleous CT, Solomon SB, Srimathveeravalli G (2015) Comparison of CT fluoroscopy-guided manual and CT-guided robotic positioning system for in vivo needle placements in swine liver. CardiovascInterventRadiol 38(5):1252–1260. https://doi.org/10.1007/s00270-014-1016-9CrossRef Cornelis F, Takaki H, Laskhmanan M, Durack JC, Erinjeri JP, Getrajdman GI, Maybody M, Sofocleous CT, Solomon SB, Srimathveeravalli G (2015) Comparison of CT fluoroscopy-guided manual and CT-guided robotic positioning system for in vivo needle placements in swine liver. CardiovascInterventRadiol 38(5):1252–1260. https://​doi.​org/​10.​1007/​s00270-014-1016-9CrossRef
8.
go back to reference Maier-Hein L, Tekbas A, Seitel A, Pianka F, Muller SA, Satzl S, Schawo S, Radeleff B, Tetzlaff R, Franz AM, Muller-Stich BP, Wolf I, Kauczor HU, Schmied BM, Meinzer HP (2008) In vivo accuracy assessment of a needle-based navigation system for CT-guided radiofrequency ablation of the liver. Med Phys 35(12):5385–5396. https://doi.org/10.1118/1.3002315CrossRefPubMed Maier-Hein L, Tekbas A, Seitel A, Pianka F, Muller SA, Satzl S, Schawo S, Radeleff B, Tetzlaff R, Franz AM, Muller-Stich BP, Wolf I, Kauczor HU, Schmied BM, Meinzer HP (2008) In vivo accuracy assessment of a needle-based navigation system for CT-guided radiofrequency ablation of the liver. Med Phys 35(12):5385–5396. https://​doi.​org/​10.​1118/​1.​3002315CrossRefPubMed
10.
go back to reference Hinds S, Jaeger HA, Burke R, O’Sullivan B, Keane J, Trauzettel F, Marques B, Cotin S, Bird B, Leira HO, Hofstad EF, Solberg OV, Lango T, Cantillon-Murphy P (2019) An open electromagnetic tracking framework applied to targeted liver tumour ablation. Int J Comput Assist RadiolSurg 14(9):1475–1484. https://doi.org/10.1007/s11548-019-01983-5CrossRef Hinds S, Jaeger HA, Burke R, O’Sullivan B, Keane J, Trauzettel F, Marques B, Cotin S, Bird B, Leira HO, Hofstad EF, Solberg OV, Lango T, Cantillon-Murphy P (2019) An open electromagnetic tracking framework applied to targeted liver tumour ablation. Int J Comput Assist RadiolSurg 14(9):1475–1484. https://​doi.​org/​10.​1007/​s11548-019-01983-5CrossRef
11.
go back to reference Moser C, Becker J, Deli M, Busch M, Boehme M, Groenemeyer DH (2013) A novel Laser Navigation System reduces radiation exposure and improves accuracy and workflow of CT-guided spinal interventions: a prospective, randomized, controlled, clinical trial in comparison to conventional freehand puncture. Eur J Radiol 82(4):627–632. https://doi.org/10.1016/j.ejrad.2012.10.028CrossRefPubMed Moser C, Becker J, Deli M, Busch M, Boehme M, Groenemeyer DH (2013) A novel Laser Navigation System reduces radiation exposure and improves accuracy and workflow of CT-guided spinal interventions: a prospective, randomized, controlled, clinical trial in comparison to conventional freehand puncture. Eur J Radiol 82(4):627–632. https://​doi.​org/​10.​1016/​j.​ejrad.​2012.​10.​028CrossRefPubMed
Metadata
Title
Robotic assistance for quick and accurate image-guided needle placement
Authors
Abigail J. Fong
Camille L. Stewart
Kelly Lafaro
Christopher J. LaRocca
Yuman Fong
Joseph D. Femino
Brooke Crawford
Publication date
01-06-2021
Publisher
Springer International Publishing
Published in
Updates in Surgery / Issue 3/2021
Print ISSN: 2038-131X
Electronic ISSN: 2038-3312
DOI
https://doi.org/10.1007/s13304-020-00956-7

Other articles of this Issue 3/2021

Updates in Surgery 3/2021 Go to the issue