Skip to main content
Top
Published in: Clinical Oral Investigations 8/2014

01-11-2014 | Original Article

Retention and surface changes of zirconia primary crowns with secondary crowns of different materials

Authors: Işıl Turp, Ergün Bozdağ, Emin Sünbüloğlu, Cem Kahruman, İbrahim Yusufoğlu, Gülsen Bayraktar

Published in: Clinical Oral Investigations | Issue 8/2014

Login to get access

Abstract

Objectives

To evaluate zirconia as a substitute for gold alloy in primary crowns facing secondary crowns manufactured with different materials, in terms of long-term retention force changes, wear, and phase transformation was aimed.

Materials and Methods

A total of 12 groups, each containing six samples, consisting of gold alloy primary crown-electroformed gold secondary crowns (AA), zirconia primary crown-electroformed gold secondary crowns (ZA) and zirconia primary crown-casted non-precious alloy secondary crowns (ZC) with conus angles of 0°, 2°, 4°, and 6° were evaluated. Samples were subjected to 10,000 insertion–separation cycles in artificial saliva and retention force was measured. X-ray diffraction and scanning electron microscope analysis were performed on the sample surfaces.

Results

The highest retention forces were obtained from ZC-0° group (72.09–71.26 N) and the lowest were obtained from ZA-4° (12.73–19.44 N) and ZA-6° (5.36–19.73 N) groups in the beginning and after 10,000 cycles, respectively. Retention force increased as the conus angle decreased. The monoclinic phase ratio of the zirconia primary crowns decreased after the experiments. No wear was observed in zirconia primary crowns except for the ZC-0° and ZC-2° groups. The use of zirconia primary crowns resulted in a less excursive retention force.

Conclusions

A more predictable and less excursive retention force can be obtained using a hard and rigid primary crown material like zirconia.

Clinical Relevance

Despite a lack of knowledge about the aging of zirconia without a veneer layer in the oral environment, zirconia primary crowns are more advantageous in terms of retention force development and wear.
Literature
1.
2.
go back to reference Besimo CH, Graber G, Flühler M (1996) Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 23:372–378PubMedCrossRef Besimo CH, Graber G, Flühler M (1996) Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 23:372–378PubMedCrossRef
3.
go back to reference Beuer F, Edelhoff D, Gernet W, Naumann M (2010) Parameters affecting retentive force of electroformed double-crown systems. Clin Oral Investig 14:129–135PubMedCrossRef Beuer F, Edelhoff D, Gernet W, Naumann M (2010) Parameters affecting retentive force of electroformed double-crown systems. Clin Oral Investig 14:129–135PubMedCrossRef
4.
go back to reference Kurbad A, Reichel K (2003) All-ceramic primary telescopic crowns with Cerec inLab. Int J Comput Dent 6:103–111PubMed Kurbad A, Reichel K (2003) All-ceramic primary telescopic crowns with Cerec inLab. Int J Comput Dent 6:103–111PubMed
5.
go back to reference Landes CA, Paffrath C, Koehler C, Thai VD, Stübinger S, Sader R, Lauer HC, Piwowarczyk A (2009) Zygoma implants for midfacial prosthetic rehabilitation using telescopes: 9-year follow-up. Int J Prosthodont 22:20–32PubMed Landes CA, Paffrath C, Koehler C, Thai VD, Stübinger S, Sader R, Lauer HC, Piwowarczyk A (2009) Zygoma implants for midfacial prosthetic rehabilitation using telescopes: 9-year follow-up. Int J Prosthodont 22:20–32PubMed
6.
go back to reference Pellecchia R, Kang KH, Hirayama H (2004) Fixed partial denture supported by all-ceramic copings: a clinical report. J Prosthet Dent 92:220–223PubMedCrossRef Pellecchia R, Kang KH, Hirayama H (2004) Fixed partial denture supported by all-ceramic copings: a clinical report. J Prosthet Dent 92:220–223PubMedCrossRef
7.
go back to reference Rösch R, Mericske-Stern R (2008) Zirkoniumdioxid in der abnehmbaren Prothetik. Schweiz Monatsschr Zahnmed 118:959–974PubMed Rösch R, Mericske-Stern R (2008) Zirkoniumdioxid in der abnehmbaren Prothetik. Schweiz Monatsschr Zahnmed 118:959–974PubMed
8.
go back to reference Shimakura M, Nagata T, Takeuchi M, Nemoto T (2008) Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system. Dent Mater J 27:211–215PubMedCrossRef Shimakura M, Nagata T, Takeuchi M, Nemoto T (2008) Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system. Dent Mater J 27:211–215PubMedCrossRef
9.
go back to reference Stamouli K, Smeekens S (2009) Rehabilitation of a periodontally compromised case using the conical crown system: Part I. Eur J Esthet Dent 4:70–80PubMed Stamouli K, Smeekens S (2009) Rehabilitation of a periodontally compromised case using the conical crown system: Part I. Eur J Esthet Dent 4:70–80PubMed
10.
go back to reference Stamouli K, Smeekens S (2009) Rehabilitation of a periodontally compromised case using the conical crown system: Part II. Eur J Esthet Dent 4:164–176PubMed Stamouli K, Smeekens S (2009) Rehabilitation of a periodontally compromised case using the conical crown system: Part II. Eur J Esthet Dent 4:164–176PubMed
11.
go back to reference Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures: ceramic vs. electroplated gold copings: Part I. In vitro tribology effects. J Biomed Mater Res 53:320–336PubMedCrossRef Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures: ceramic vs. electroplated gold copings: Part I. In vitro tribology effects. J Biomed Mater Res 53:320–336PubMedCrossRef
12.
go back to reference Weigl P (2003) Implant prosthodontics: what next? Quintessence Int 34:653–669PubMed Weigl P (2003) Implant prosthodontics: what next? Quintessence Int 34:653–669PubMed
13.
go back to reference Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures: ceramic vs. electroplated gold copings: Part II. Clinical effects. J Biomed Mater Res 53:337–347PubMedCrossRef Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures: ceramic vs. electroplated gold copings: Part II. Clinical effects. J Biomed Mater Res 53:337–347PubMedCrossRef
14.
go back to reference Valderhaug J, Ellingsen JE, Jokstad A (1993) Oral hygiene, periodontal conditions and carious lesions in patients treated with dental bridges. A 15-year clinical and radiographic follow-up study. J Clin Periodontol 20:482–489PubMedCrossRef Valderhaug J, Ellingsen JE, Jokstad A (1993) Oral hygiene, periodontal conditions and carious lesions in patients treated with dental bridges. A 15-year clinical and radiographic follow-up study. J Clin Periodontol 20:482–489PubMedCrossRef
15.
go back to reference Uludağ B, Şahin V, Öztürk Ö (2008) Fabrication of zirconium primary copings to provide retention for a mandibular telescopic overdenture: a clinical report. Int J Prosthodont 21:509–510PubMed Uludağ B, Şahin V, Öztürk Ö (2008) Fabrication of zirconium primary copings to provide retention for a mandibular telescopic overdenture: a clinical report. Int J Prosthodont 21:509–510PubMed
16.
go back to reference Bayer S, Zuziak W, Kraus D, Keilig L, Stark H, Enkling N (2011) Conical crowns with electroplated gold copings: retention force changes caused by wear and combined off-axial load. Clin Oral Implants Res 22:323–329PubMedCrossRef Bayer S, Zuziak W, Kraus D, Keilig L, Stark H, Enkling N (2011) Conical crowns with electroplated gold copings: retention force changes caused by wear and combined off-axial load. Clin Oral Implants Res 22:323–329PubMedCrossRef
17.
go back to reference Engels J, Schubert O, Güth JF, Hoffmann M, Jauernig C, Erdelt K, Stimmelmayr M, Beuer F (2013) Wear behavior of different double-crown systems. Clin Oral Investig 17:503–510PubMedCrossRef Engels J, Schubert O, Güth JF, Hoffmann M, Jauernig C, Erdelt K, Stimmelmayr M, Beuer F (2013) Wear behavior of different double-crown systems. Clin Oral Investig 17:503–510PubMedCrossRef
18.
go back to reference Shannon IL (1982) Fluoride treatment programs for high-caries-risk patients. Clin Prevent Dent 4:11–20 Shannon IL (1982) Fluoride treatment programs for high-caries-risk patients. Clin Prevent Dent 4:11–20
19.
go back to reference Garvie RC, Nicholson PS (1972) Phase analysis in zirconia systems. J Am Ceram Soc 55:303–305CrossRef Garvie RC, Nicholson PS (1972) Phase analysis in zirconia systems. J Am Ceram Soc 55:303–305CrossRef
20.
go back to reference Toraya H, Yoshimura M, Sōmiya S (1984) Calibration curve for quantitative analysis of the monoclinictetragonal ZrO2 system by X-ray diffraction. J Am Ceram Soc 67:C119–C121 Toraya H, Yoshimura M, Sōmiya S (1984) Calibration curve for quantitative analysis of the monoclinictetragonal ZrO2 system by X-ray diffraction. J Am Ceram Soc 67:C119–C121
21.
go back to reference Greven B, Luepke M, von Dorsche SH (2007) Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 98:239–244PubMedCrossRef Greven B, Luepke M, von Dorsche SH (2007) Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 98:239–244PubMedCrossRef
22.
go back to reference Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64:153–158PubMedCrossRef Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64:153–158PubMedCrossRef
23.
go back to reference Güngör MA, Artunç C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31:271–277PubMedCrossRef Güngör MA, Artunç C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31:271–277PubMedCrossRef
24.
go back to reference Fernandes CP, Glantz PO, Svensson SA, Bergmark A (2003) A novel sensor for bite force determinations. Dent Mater 19:118–126PubMedCrossRef Fernandes CP, Glantz PO, Svensson SA, Bergmark A (2003) A novel sensor for bite force determinations. Dent Mater 19:118–126PubMedCrossRef
25.
go back to reference Rössler J (2005) Der Haftmechanismus von Galvano-Doppelkronen-Systemen und seine Beeinflussbarkeit durch Zwischenflüssigkeiten. Dissertation, Die Friedrich-Schiller-Universität Jena Rössler J (2005) Der Haftmechanismus von Galvano-Doppelkronen-Systemen und seine Beeinflussbarkeit durch Zwischenflüssigkeiten. Dissertation, Die Friedrich-Schiller-Universität Jena
26.
go back to reference Anusavice KJ (2003) Phillips’ science of dental materials. Elsevier, Missouri Anusavice KJ (2003) Phillips’ science of dental materials. Elsevier, Missouri
30.
go back to reference Körber KH (1973) Konuskronen Teleskope Einführung in Klinik und Technik. Dr. Alfred Hüthig Verlag GmbH, Heidelberg Körber KH (1973) Konuskronen Teleskope Einführung in Klinik und Technik. Dr. Alfred Hüthig Verlag GmbH, Heidelberg
31.
go back to reference Gütschow F (1994) Möglichkeit der Beeiflussung des Verschliessen von Teleskopkronen durch TIN-Beschichtung. Deutsche Zahnaerztliche Zeitschrift 49:444 Gütschow F (1994) Möglichkeit der Beeiflussung des Verschliessen von Teleskopkronen durch TIN-Beschichtung. Deutsche Zahnaerztliche Zeitschrift 49:444
32.
go back to reference Lenz J, Schindler HJ, Pelka H (1992) Die Keramikverblendete NEM-Konuskrone. Quintessenz Verlags-GmbH, Berlin Lenz J, Schindler HJ, Pelka H (1992) Die Keramikverblendete NEM-Konuskrone. Quintessenz Verlags-GmbH, Berlin
33.
go back to reference Deville S, Chevalier J, Gremillard L (2006) Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia. Biomaterials 27:2186–2192PubMedCrossRef Deville S, Chevalier J, Gremillard L (2006) Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia. Biomaterials 27:2186–2192PubMedCrossRef
34.
go back to reference Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L (1999) The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater 15:426–433PubMedCrossRef Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L (1999) The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater 15:426–433PubMedCrossRef
35.
go back to reference Guazzato M, Albakry M, Quach L, Swain MV (2005) Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic. Dent Mater 21:454–463PubMedCrossRef Guazzato M, Albakry M, Quach L, Swain MV (2005) Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic. Dent Mater 21:454–463PubMedCrossRef
36.
go back to reference Papanagiotou HP, Morgano SM, Giordano RA, Pober R (2006) In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthet Dent 96:154–164PubMedCrossRef Papanagiotou HP, Morgano SM, Giordano RA, Pober R (2006) In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthet Dent 96:154–164PubMedCrossRef
37.
go back to reference Pittayachawan P, McDonald A, Young A, Knowles JC (2009) Flexural strength, fatigue life, and stress-induced phase transformation study of Y-TZP dental ceramic. J Biomed Mater Res B Appl Biomater 88:366–377PubMedCrossRef Pittayachawan P, McDonald A, Young A, Knowles JC (2009) Flexural strength, fatigue life, and stress-induced phase transformation study of Y-TZP dental ceramic. J Biomed Mater Res B Appl Biomater 88:366–377PubMedCrossRef
38.
go back to reference Denry IL, Holloway JA (2006) Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics. J Biomed Mater Res B Appl Biomater 76:440–448PubMedCrossRef Denry IL, Holloway JA (2006) Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics. J Biomed Mater Res B Appl Biomater 76:440–448PubMedCrossRef
39.
go back to reference Deville S, Gremillard L, Chevalier J, Fantozzi G (2005) A critical comparison of methods for the determination of the aging sensitivity in biomedical grade yttria-stabilized zirconia. J Biomed Mater Res B Appl Biomater 72:239–245PubMedCrossRef Deville S, Gremillard L, Chevalier J, Fantozzi G (2005) A critical comparison of methods for the determination of the aging sensitivity in biomedical grade yttria-stabilized zirconia. J Biomed Mater Res B Appl Biomater 72:239–245PubMedCrossRef
40.
go back to reference Brown SS, Green DD, Pezzotti G, Donaldson TK, Clarke IC (2008) Possible triggers for phase transformation in zirconia hip balls. J Biomed Mater Res Part B: Appl Biomater 85B:444–452CrossRef Brown SS, Green DD, Pezzotti G, Donaldson TK, Clarke IC (2008) Possible triggers for phase transformation in zirconia hip balls. J Biomed Mater Res Part B: Appl Biomater 85B:444–452CrossRef
41.
go back to reference He YJ, Winnubst L, Burggraaf AJ, Verwerji H, vander Varst PGT, deWith B (1996) Grain-size dependence of sliding wear in tetragonal zirconia polycrystals. J Am Ceram Soc 79:3090–3096CrossRef He YJ, Winnubst L, Burggraaf AJ, Verwerji H, vander Varst PGT, deWith B (1996) Grain-size dependence of sliding wear in tetragonal zirconia polycrystals. J Am Ceram Soc 79:3090–3096CrossRef
42.
go back to reference Hooper RM, Morgan JE (1989) Wear processes in the diamond grinding of zirconia ceramics. Wear 130:353–356CrossRef Hooper RM, Morgan JE (1989) Wear processes in the diamond grinding of zirconia ceramics. Wear 130:353–356CrossRef
43.
go back to reference Vagkopoulou T, Koutayas SO, Koidis P, Strub JR (2009) Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent 4:130–151PubMed Vagkopoulou T, Koutayas SO, Koidis P, Strub JR (2009) Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent 4:130–151PubMed
44.
go back to reference Bayer S, Steinheuser D, Grüner M, Keilig L, Enkling N, Stark H, Mues S (2009) Comparative study of four retentive anchor systems for implant supported overdentures—retention force changes. Gerodontology 26:268–272PubMedCrossRef Bayer S, Steinheuser D, Grüner M, Keilig L, Enkling N, Stark H, Mues S (2009) Comparative study of four retentive anchor systems for implant supported overdentures—retention force changes. Gerodontology 26:268–272PubMedCrossRef
45.
go back to reference Wichmann MG, Kuntze W (1999) Wear behavior of precision attachments. Int J Prosthodont 12:409–414PubMed Wichmann MG, Kuntze W (1999) Wear behavior of precision attachments. Int J Prosthodont 12:409–414PubMed
46.
go back to reference Lughi V, Sergo V (2010) Low temperature degradation — aging – of zirconia: a critical review of the relevant aspects in dentistry. Dent Mater 26:807–820PubMedCrossRef Lughi V, Sergo V (2010) Low temperature degradation — aging – of zirconia: a critical review of the relevant aspects in dentistry. Dent Mater 26:807–820PubMedCrossRef
Metadata
Title
Retention and surface changes of zirconia primary crowns with secondary crowns of different materials
Authors
Işıl Turp
Ergün Bozdağ
Emin Sünbüloğlu
Cem Kahruman
İbrahim Yusufoğlu
Gülsen Bayraktar
Publication date
01-11-2014
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 8/2014
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-013-1183-0

Other articles of this Issue 8/2014

Clinical Oral Investigations 8/2014 Go to the issue