Skip to main content
Top
Published in: Clinical Oral Investigations 2/2010

01-04-2010 | Original Article

Parameters affecting retentive force of electroformed double-crown systems

Authors: Florian Beuer, Daniel Edelhoff, Wolfgang Gernet, Michael Naumann

Published in: Clinical Oral Investigations | Issue 2/2010

Login to get access

Abstract

The aim of this study was to determine the values of retentive forces of double crowns. The effect of the abutment height, the material of the inner crown, and the taper were evaluated. Sixty inner crowns each were fabricated from zirconia and a gold alloy having three different abutment heights (5, 7, and 9 mm) and two different tapers (0° and 2°). All outer crowns were made with an electroforming system. The removal test was performed by a standardized setup using a universal testing machine at a crosshead speed of 1,000 mm min−1. Ten separation cycles were performed of each specimen, and the mean was imported into a statistical program. The retention forces were in the range of 0.37 and 2.65 N. The abutment height (p < 0.001), the material of the inner crown (p = 0.035), and the taper (p < 0.001) showed statistical influence on the retention force in the two-way ANOVA. Zirconia primary crowns performed better than gold alloy in the 0° group, especially with short abutments. However, a taper of 0° and short abutments have clinical drawbacks that were not evaluated in this study. In situations with long abutment teeth and a 2° taper zirconia is an alternative to gold alloy primary crowns.
Literature
1.
go back to reference Becker H (1982) Untersuchung der Abzugskräfte abnehmbarer Teleskop-Prothesen. Zahnärztl Prax 33:153–156PubMed Becker H (1982) Untersuchung der Abzugskräfte abnehmbarer Teleskop-Prothesen. Zahnärztl Prax 33:153–156PubMed
2.
go back to reference Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90CrossRefPubMed Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90CrossRefPubMed
3.
go back to reference Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22:927–928, 929-932, 934 passim; quiz 942PubMed Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22:927–928, 929-932, 934 passim; quiz 942PubMed
4.
go back to reference Besimo CH, Graber G, Fluhler M (1996) Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 23:372–378CrossRefPubMed Besimo CH, Graber G, Fluhler M (1996) Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 23:372–378CrossRefPubMed
5.
go back to reference Beuer F, Aggstaller H, Edelhoff D, Gernet W (2008) Effect of Preparation Design on the Fracture Resistance of Zirconia Crown Copings. Dent Mater J 27:362–367CrossRefPubMed Beuer F, Aggstaller H, Edelhoff D, Gernet W (2008) Effect of Preparation Design on the Fracture Resistance of Zirconia Crown Copings. Dent Mater J 27:362–367CrossRefPubMed
6.
go back to reference Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J (2009) Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 25:94–102CrossRefPubMed Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J (2009) Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 25:94–102CrossRefPubMed
7.
go back to reference Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511CrossRefPubMed Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511CrossRefPubMed
8.
go back to reference Beuer F, Steff B, Naumann M, Sorensen J (2008) Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated materials. Eur J Oral Sci 116:381–386CrossRefPubMed Beuer F, Steff B, Naumann M, Sorensen J (2008) Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated materials. Eur J Oral Sci 116:381–386CrossRefPubMed
9.
go back to reference Bindl A, Mormann WH (2003) Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns. Eur J Oral Sci 111:163–169CrossRefPubMed Bindl A, Mormann WH (2003) Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns. Eur J Oral Sci 111:163–169CrossRefPubMed
10.
go back to reference Bindl A, Mormann WH (2004) Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2–5 years. Eur J Oral Sci 112:197–204CrossRefPubMed Bindl A, Mormann WH (2004) Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2–5 years. Eur J Oral Sci 112:197–204CrossRefPubMed
11.
go back to reference Eisenburger M, Gray G, Tschernitschek H (2000) Long-term results of telescopic crown retained dentures–a retrospective study. Eur J Prosthodont Restor Dent 8:87–91PubMed Eisenburger M, Gray G, Tschernitschek H (2000) Long-term results of telescopic crown retained dentures–a retrospective study. Eur J Prosthodont Restor Dent 8:87–91PubMed
12.
go back to reference El-Mowafy O, Brochu JF (2002) Longevity and clinical performance of IPS-Empress ceramic restorations–a literature review. J Can Dent Assoc 68:233–237PubMed El-Mowafy O, Brochu JF (2002) Longevity and clinical performance of IPS-Empress ceramic restorations–a literature review. J Can Dent Assoc 68:233–237PubMed
13.
go back to reference Gungor MA, Artunc C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31:271–277CrossRefPubMed Gungor MA, Artunc C, Sonugelen M (2004) Parameters affecting retentive force of conus crowns. J Oral Rehabil 31:271–277CrossRefPubMed
14.
go back to reference Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed
15.
go back to reference Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed
17.
go back to reference Lee MW, Baum L, Pence B Sr, Hererra W (1995) O-ring coping attachments for removable partial dentures. J Prosthet Dent 74:235–241CrossRefPubMed Lee MW, Baum L, Pence B Sr, Hererra W (1995) O-ring coping attachments for removable partial dentures. J Prosthet Dent 74:235–241CrossRefPubMed
18.
go back to reference Luthardt RG, Holzhuter M, Sandkuhl O, Herold V, Schnapp JD, Kuhlisch E et al (2002) Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res 81:487–491CrossRefPubMed Luthardt RG, Holzhuter M, Sandkuhl O, Herold V, Schnapp JD, Kuhlisch E et al (2002) Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res 81:487–491CrossRefPubMed
19.
go back to reference Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81:684–688CrossRefPubMed Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81:684–688CrossRefPubMed
20.
go back to reference Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64:153–158CrossRefPubMed Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64:153–158CrossRefPubMed
21.
go back to reference Ohlmann B, Rohstock K, Kugler J, Gilde H, Nat R, Dreyhaupt J et al (2007) Influences on clinical wear of acrylic denture teeth: a pilot study. Int J Prosthodont 20:496–498PubMed Ohlmann B, Rohstock K, Kugler J, Gilde H, Nat R, Dreyhaupt J et al (2007) Influences on clinical wear of acrylic denture teeth: a pilot study. Int J Prosthodont 20:496–498PubMed
22.
go back to reference Owall G, Bieniek K, Spiekermann H (1995) Removable partial denture production in western Germany. Quintessence Int 26:621–627PubMed Owall G, Bieniek K, Spiekermann H (1995) Removable partial denture production in western Germany. Quintessence Int 26:621–627PubMed
24.
go back to reference Raigrodski AJ (2005) All-ceramic full-coverage restorations: concepts and guidelines for material selection. Pract Proced Aesthet Dent 17:249–256, quiz 258PubMed Raigrodski AJ (2005) All-ceramic full-coverage restorations: concepts and guidelines for material selection. Pract Proced Aesthet Dent 17:249–256, quiz 258PubMed
25.
go back to reference Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S et al (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244CrossRefPubMed Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S et al (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244CrossRefPubMed
26.
go back to reference Raigrodski AJ, Chiche GJ, Swift EJ Jr (2002) All-ceramic fixed partial dentures, Part III: clinical studies. J Esthet Restor Dent 14:313–319CrossRefPubMed Raigrodski AJ, Chiche GJ, Swift EJ Jr (2002) All-ceramic fixed partial dentures, Part III: clinical studies. J Esthet Restor Dent 14:313–319CrossRefPubMed
27.
go back to reference Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed
28.
go back to reference Sorensen JA, Choi C, Fanuscu MI, Mito WT (1998) IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc 26:130–136PubMed Sorensen JA, Choi C, Fanuscu MI, Mito WT (1998) IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc 26:130–136PubMed
29.
go back to reference Tinschert J, Natt G, Hassenpflug S, Spiekermann H (2004) Status of current CAD/CAM technology in dental medicine. Int J Comput Dent 7:25–45PubMed Tinschert J, Natt G, Hassenpflug S, Spiekermann H (2004) Status of current CAD/CAM technology in dental medicine. Int J Comput Dent 7:25–45PubMed
30.
go back to reference Tinschert J, Zwez D, Marx R, Anusavice KJ (2000) Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. J Dent 28:529–535CrossRefPubMed Tinschert J, Zwez D, Marx R, Anusavice KJ (2000) Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. J Dent 28:529–535CrossRefPubMed
31.
go back to reference Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187CrossRefPubMed Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187CrossRefPubMed
32.
33.
go back to reference Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed
34.
go back to reference Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed
35.
go back to reference Wenz HJ, Hertrampf K, Lehmann KM (2001) Clinical longevity of removable partial dentures retained by telescopic crowns: outcome of the double crown with clearance fit. Int J Prosthodont 14:207–213PubMed Wenz HJ, Hertrampf K, Lehmann KM (2001) Clinical longevity of removable partial dentures retained by telescopic crowns: outcome of the double crown with clearance fit. Int J Prosthodont 14:207–213PubMed
36.
go back to reference Wenz HJ, Lehmann KM (1998) A telescopic crown concept for the restoration of the partially edentulous arch: the Marburg double crown system. Int J Prosthodont 11:541–550PubMed Wenz HJ, Lehmann KM (1998) A telescopic crown concept for the restoration of the partially edentulous arch: the Marburg double crown system. Int J Prosthodont 11:541–550PubMed
37.
go back to reference Witkowski S, Komine F, Gerds T (2006) Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent 96:47–52CrossRefPubMed Witkowski S, Komine F, Gerds T (2006) Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent 96:47–52CrossRefPubMed
Metadata
Title
Parameters affecting retentive force of electroformed double-crown systems
Authors
Florian Beuer
Daniel Edelhoff
Wolfgang Gernet
Michael Naumann
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 2/2010
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-009-0271-7

Other articles of this Issue 2/2010

Clinical Oral Investigations 2/2010 Go to the issue