Skip to main content
Top
Published in: Pediatric Cardiology 4/2021

01-04-2021 | Pulmonary Valve Replacement | Original Article

Novel Minimal Radiation Approach for Percutaneous Pulmonary Valve Implantation

Authors: Jenny E. Zablah, Salvador A. Rodriguez, Ryan Leahy, Gareth J. Morgan

Published in: Pediatric Cardiology | Issue 4/2021

Login to get access

Abstract

The aim of the study is to evaluate the impact of multimodality imaging technology during percutaneous pulmonary valve implantation (PPVI). Among percutaneous procedures, PPVI traditionally has one of the highest patient radiation exposures. Different protocol modifications have been implemented to address this problem (i.e., improvements in guidance systems, delivery systems, valve design, post-implantation evaluation). Although the effectiveness of individual modifications has been proven, the effect of an approach which combines these changes has not been reported. We performed a retrospective chart review of 76 patients who underwent PPVI between January 2018 and December 2019. Patients were classified in “Traditional protocol,” using routine biplane angiography and/or 3D rotational angiography (3DRA); and “Multimodality protocol” that included the use of VesselNavigator for guidance, selective 3DRA for coronary evaluation, Long DrySeal Sheath for valve delivery, and Intracardiac Echocardiography for valve evaluation after implantation. Radiation metrics, procedural time, and clinical outcomes were compared between groups. When the traditional protocol group was compared with the multimodality protocol group, a significant reduction was described for total fluoroscopy time (31.6 min vs. 26.2 min), dose of contrast per kilogram (1.8 mL/Kg vs. 0.9 mL/Kg), DAP/kg (26.6 µGy·m2/kg vs. 19.9 µGy·m2/kg), and Air Kerma (194 mGy vs. 99.9 mGy). A reduction for procedure time was noted (140 min vs. 116.5 min), but this was not statistically significant. There was no difference in clinical outcomes or the presence of complications between groups. The combination of novel technology in PPVI caused a significant reduction in radiation metrics without increasing the complication rate in our population.
Appendix
Available only for authorised users
Literature
8.
go back to reference Cevallos PC, Armstrong AK, Glatz AC, Goldstein BH, Gudausky TM, Leahy RA et al (2017) Radiation dose benchmarks in pediatric cardiac catheterization: A prospective multi-center C3PO-QI study. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 90(2):269–280. https://doi.org/10.1002/ccd.26911CrossRef Cevallos PC, Armstrong AK, Glatz AC, Goldstein BH, Gudausky TM, Leahy RA et al (2017) Radiation dose benchmarks in pediatric cardiac catheterization: A prospective multi-center C3PO-QI study. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 90(2):269–280. https://​doi.​org/​10.​1002/​ccd.​26911CrossRef
11.
go back to reference Goreczny S, Moszura T, Dryzek P, Lukaszewski M, Krawczuk A, Moll J et al (2017) Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 25(2):91–99. https://doi.org/10.1007/s12471-016-0941-4CrossRefPubMed Goreczny S, Moszura T, Dryzek P, Lukaszewski M, Krawczuk A, Moll J et al (2017) Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 25(2):91–99. https://​doi.​org/​10.​1007/​s12471-016-0941-4CrossRefPubMed
12.
13.
go back to reference Góreczny S, Dryżek P, Moszura T, Łukaszewski M, Podgórski M, Nordmeyer S et al (2018) Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation. Postepy W Kardiologii Interwencyjnej Adv Interv Cardiol 14(4):413–421. https://doi.org/10.5114/aic.2018.79871CrossRef Góreczny S, Dryżek P, Moszura T, Łukaszewski M, Podgórski M, Nordmeyer S et al (2018) Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation. Postepy W Kardiologii Interwencyjnej Adv Interv Cardiol 14(4):413–421. https://​doi.​org/​10.​5114/​aic.​2018.​79871CrossRef
15.
go back to reference Fukuda T, Tan W, Sadeghi S, Lin J, Salem M, Levi D et al (2020) Utility of the long DrySeal sheath in facilitating transcatheter pulmonary valve implantation with the Edwards SAPIEN 3 valve. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv. https://doi.org/10.1002/ccd.28776CrossRef Fukuda T, Tan W, Sadeghi S, Lin J, Salem M, Levi D et al (2020) Utility of the long DrySeal sheath in facilitating transcatheter pulmonary valve implantation with the Edwards SAPIEN 3 valve. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv. https://​doi.​org/​10.​1002/​ccd.​28776CrossRef
16.
go back to reference Kenny D, Morgan GJ, Murphy M, AlAlwi K, Giugno L, Zablah J et al (2019) Use of 65 cm large caliber Dryseal sheaths to facilitate delivery of the Edwards SAPIEN valve to dysfunctional right ventricular outflow tracts. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 94(3):409–413. https://doi.org/10.1002/ccd.28409CrossRef Kenny D, Morgan GJ, Murphy M, AlAlwi K, Giugno L, Zablah J et al (2019) Use of 65 cm large caliber Dryseal sheaths to facilitate delivery of the Edwards SAPIEN valve to dysfunctional right ventricular outflow tracts. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 94(3):409–413. https://​doi.​org/​10.​1002/​ccd.​28409CrossRef
17.
Metadata
Title
Novel Minimal Radiation Approach for Percutaneous Pulmonary Valve Implantation
Authors
Jenny E. Zablah
Salvador A. Rodriguez
Ryan Leahy
Gareth J. Morgan
Publication date
01-04-2021
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 4/2021
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-021-02564-7

Other articles of this Issue 4/2021

Pediatric Cardiology 4/2021 Go to the issue