Skip to main content
Top
Published in: Pediatric Cardiology 8/2016

01-12-2016 | Original Article

Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory

Authors: Hoang H. Nguyen, David T. Balzer, Joshua J. Murphy, Ramzi Nicolas, Shabana Shahanavaz

Published in: Pediatric Cardiology | Issue 8/2016

Login to get access

Abstract

This retrospective study aims to evaluate radiation exposure by three-dimensional rotational angiography (3DRA) during trans-catheter Melody pulmonary valve (TMPV) procedures. 3DRA has been reported to have added value in the management of complex congenital heart disease aiding in the performance of interventional procedures albeit with concerns of higher radiation exposure. We test the hypothesis that 3DRA does not cause additional radiation exposure during TMPV procedures. We analyzed all 81 TMPV procedures performed at St. Louis Children’s Hospital, MO, USA, from January 1, 2011 to December 31, 2014. Dose-area product (DAP), DAP indexed to body weight (DAP/BW), fluoroscopy time (FT), and weight–fluoroscopy time product of each procedure were recorded. We reviewed each procedure’s images to determine whether additional interventions were performed (e.g., pulmonary artery angioplasty or treatment of conduit pseudo-aneurysm). 3DRA was used in 36 % of the procedures. 3DRA group had a higher number of additional procedures performed. The 3DRA group did not differ from the non-3DRA group in DAP, DAP/BW, and weight–fluoroscopy time product. 3DRA does not cause greater radiation exposure during TMPV procedures.
Literature
1.
go back to reference Johnson JN, Hornik CP, Li JS, Benjamin DK, Yoshizumi TT, Reiman RE, Frush DP, Hill KD (2014) Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation 130:161–167CrossRefPubMedPubMedCentral Johnson JN, Hornik CP, Li JS, Benjamin DK, Yoshizumi TT, Reiman RE, Frush DP, Hill KD (2014) Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation 130:161–167CrossRefPubMedPubMedCentral
2.
go back to reference Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed
3.
go back to reference Ghelani SJ, Glatz AC, Stuthi D, Leahy R, Hirsch R, Armsby LB, Trucco SM, Holzer RJ, Bergersen L (2014) Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States. J Am Coll Cardiol Interv 7:1060–1069CrossRef Ghelani SJ, Glatz AC, Stuthi D, Leahy R, Hirsch R, Armsby LB, Trucco SM, Holzer RJ, Bergersen L (2014) Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States. J Am Coll Cardiol Interv 7:1060–1069CrossRef
4.
go back to reference Hijazi ZM, Awad SM (2008) Pediatric cardiac interventions. J Am Coll Cardiol Interv 1:603–611CrossRef Hijazi ZM, Awad SM (2008) Pediatric cardiac interventions. J Am Coll Cardiol Interv 1:603–611CrossRef
5.
go back to reference Glatz AC, Zhu X, Gillespie J, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. J Am Coll Cardiol Imaging 3:1149–1157CrossRef Glatz AC, Zhu X, Gillespie J, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. J Am Coll Cardiol Imaging 3:1149–1157CrossRef
6.
go back to reference Glockler M, Koch A, Greim V, Shabaiek A, Ruffer A, Cesnjevar R, Achenbach S, Dittrich S (2011) The value of flat-detector computed tomography during catheterization of congenital heart disease. Eur Radiol 21:2511–2520CrossRefPubMed Glockler M, Koch A, Greim V, Shabaiek A, Ruffer A, Cesnjevar R, Achenbach S, Dittrich S (2011) The value of flat-detector computed tomography during catheterization of congenital heart disease. Eur Radiol 21:2511–2520CrossRefPubMed
7.
go back to reference Glockler M, Halbfass J, Koch A, Achenbach S, Dittrich S (2013) Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease: a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 82:436–442CrossRefPubMed Glockler M, Halbfass J, Koch A, Achenbach S, Dittrich S (2013) Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease: a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 82:436–442CrossRefPubMed
8.
go back to reference Fagan T, Kay J, Carroll J, Neubauer A (2012) 3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay. Catheter Cardiovasc Interv 79:414–421CrossRefPubMed Fagan T, Kay J, Carroll J, Neubauer A (2012) 3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay. Catheter Cardiovasc Interv 79:414–421CrossRefPubMed
9.
go back to reference Boothroyd A, McDonald E, Moores BM, Sluming V, Carty H (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185CrossRefPubMed Boothroyd A, McDonald E, Moores BM, Sluming V, Carty H (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185CrossRefPubMed
10.
go back to reference Rassow J, Schmaltz AA, Heintrich F, Steffer C (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183CrossRefPubMed Rassow J, Schmaltz AA, Heintrich F, Steffer C (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183CrossRefPubMed
11.
go back to reference Martinez LC, Vano E, Gutierrez F, Rodriguez C, Gilarranz R, Manzanas MJ (2007) Patient doses from fluoroscopically guided cardiac procedures in pediatrics. Phys Med Biol 52:4749–4759CrossRefPubMed Martinez LC, Vano E, Gutierrez F, Rodriguez C, Gilarranz R, Manzanas MJ (2007) Patient doses from fluoroscopically guided cardiac procedures in pediatrics. Phys Med Biol 52:4749–4759CrossRefPubMed
12.
go back to reference Ubeda C, Vano E, Miranda P, Leyton F (2012) Pilot program on patient dosimetry in pediatric interventional cardiology in Chile. Med Phys 39:2424–2430CrossRefPubMed Ubeda C, Vano E, Miranda P, Leyton F (2012) Pilot program on patient dosimetry in pediatric interventional cardiology in Chile. Med Phys 39:2424–2430CrossRefPubMed
13.
go back to reference Chida K, Ohno T, Takegawa M, Yuuki H, Nakada M, Takahashi S, Zuguchi M (2010) Radiation doses to the pediatric cardiac catheterization and intervention patient. Am J Roent 195:1175–1179CrossRef Chida K, Ohno T, Takegawa M, Yuuki H, Nakada M, Takahashi S, Zuguchi M (2010) Radiation doses to the pediatric cardiac catheterization and intervention patient. Am J Roent 195:1175–1179CrossRef
14.
go back to reference Glatz AC, Patel A, Zhu X, Dori Y, Hanna BD, Gillespie MJ, Rome JJ (2014) Patient radiation exposure in a modern, large-volume, pediatric cardiac catheterization laboratory. Pediatr Cardiol 35:870–878CrossRefPubMed Glatz AC, Patel A, Zhu X, Dori Y, Hanna BD, Gillespie MJ, Rome JJ (2014) Patient radiation exposure in a modern, large-volume, pediatric cardiac catheterization laboratory. Pediatr Cardiol 35:870–878CrossRefPubMed
15.
go back to reference Verghese GR, McElhinney DB, Strauss KJ, Bergensen L (2012) Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab. Catheter Cardiovasc Interv 79:294–301CrossRefPubMed Verghese GR, McElhinney DB, Strauss KJ, Bergensen L (2012) Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab. Catheter Cardiovasc Interv 79:294–301CrossRefPubMed
16.
go back to reference Reinke G, Halbfass J, Dittrich S, Banckwitz R, Kohler C, Achenbach S, Rompel O, Glocker M (2013) Three-dimensional rotational angiography in congenital heart disease: estimation of radiation exposure. Open J Radiol 3:124–129CrossRef Reinke G, Halbfass J, Dittrich S, Banckwitz R, Kohler C, Achenbach S, Rompel O, Glocker M (2013) Three-dimensional rotational angiography in congenital heart disease: estimation of radiation exposure. Open J Radiol 3:124–129CrossRef
17.
go back to reference Manica JLL, Borges MS, de Medeiros RF, dos Santos Fischer L, Broetto G, Rossi Filho RI (2014) A comparison of radiation dose between standard and 3D angiography in congenital heart disease. Arq Bras Cardiol 103:131–137PubMedPubMedCentral Manica JLL, Borges MS, de Medeiros RF, dos Santos Fischer L, Broetto G, Rossi Filho RI (2014) A comparison of radiation dose between standard and 3D angiography in congenital heart disease. Arq Bras Cardiol 103:131–137PubMedPubMedCentral
18.
go back to reference Corredoira E, Vano E, Ubeda C, Gutierrez-Larraya F (2015) Patient doses in pediatric interventional cardiology: impact of 3D rotational angiography. J Radiol Prot 35:179–195CrossRefPubMed Corredoira E, Vano E, Ubeda C, Gutierrez-Larraya F (2015) Patient doses in pediatric interventional cardiology: impact of 3D rotational angiography. J Radiol Prot 35:179–195CrossRefPubMed
19.
go back to reference Peters M, Krings G, Koster M, Molenschot M, Freund MW, Breur JMPJ (2015) Effective radiation dosage of three-dimensional rotational angiography in children. Europace 17:611–616CrossRefPubMed Peters M, Krings G, Koster M, Molenschot M, Freund MW, Breur JMPJ (2015) Effective radiation dosage of three-dimensional rotational angiography in children. Europace 17:611–616CrossRefPubMed
20.
go back to reference Kapins CEB, Coutinho RB, Barbosa FB, Silva CMC, Lima VC, Carvalho AC (2010) Use of 3D rotational angiography in congenital heart disease: experience with 53 patients. Rev Bras Cardiol Invasiva 18:199–203CrossRef Kapins CEB, Coutinho RB, Barbosa FB, Silva CMC, Lima VC, Carvalho AC (2010) Use of 3D rotational angiography in congenital heart disease: experience with 53 patients. Rev Bras Cardiol Invasiva 18:199–203CrossRef
21.
go back to reference Berman DP, Khan DM, Gutierrez Y, Zahn EM (2012) The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle. Catheter Cardiovasc Interv 80:922–930CrossRefPubMed Berman DP, Khan DM, Gutierrez Y, Zahn EM (2012) The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle. Catheter Cardiovasc Interv 80:922–930CrossRefPubMed
22.
go back to reference Kobayashi D, Meadows J, Forbes TJ, Moore P, Javois AJ, Pedra CA, Du W, Gruenstein DH, Wax DF, Hill JA, Graziano JN, Fagan TE, Alvarez WM, Nykanen DG, Divekar AA (2014) Standardizing radiation dose reporting in the pediatric cardiac catheterization laboratory: a multicenter study by the CCISC (Congenital Cardiovascular Interventional Study Consortium). Catheter Cardiovasc Interv 84:785–793CrossRefPubMed Kobayashi D, Meadows J, Forbes TJ, Moore P, Javois AJ, Pedra CA, Du W, Gruenstein DH, Wax DF, Hill JA, Graziano JN, Fagan TE, Alvarez WM, Nykanen DG, Divekar AA (2014) Standardizing radiation dose reporting in the pediatric cardiac catheterization laboratory: a multicenter study by the CCISC (Congenital Cardiovascular Interventional Study Consortium). Catheter Cardiovasc Interv 84:785–793CrossRefPubMed
Metadata
Title
Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory
Authors
Hoang H. Nguyen
David T. Balzer
Joshua J. Murphy
Ramzi Nicolas
Shabana Shahanavaz
Publication date
01-12-2016
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 8/2016
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1453-0

Other articles of this Issue 8/2016

Pediatric Cardiology 8/2016 Go to the issue