Noninvasive estimation of quantitative myocardial blood flow with Tc-99m MIBI by a compartment model analysis in rat

Authors: Atsutaka Okizaki, MD, PhD, Michihiro Nakayama, MD, PhD, Kaori Nakajima, MD, Osuke Fujimoto, DVM, Shinobu Oshikiri, MS, Miho Koike-Satake, MS, Yuto Nakahara, MS

Published in: Journal of Nuclear Cardiology | Issue 4/2020

Login to get access

Abstract

Background

We aimed to investigate the use of dynamic cardiac planar images to estimate myocardial blood flow (MBF) by a compartment model analysis using time-to-peak (TP) map and compared it by the microsphere technique in rat. Positron emission tomography is considered the gold standard method, but is not available everywhere. By contrast, although myocardial perfusion imaging (MPI) with single-photon tracers is more widely available, it may be difficult to obtain adequate region of interest (ROI) settings. We proposed using the TP map to set the ROI, and hypothesized that this method could facilitate the measurement of absolute MBF by MPI in rat.

Methods

Twenty-one normal rats were studied. Dynamic planar images with Tc-99m MIBI were obtained, and input function and cardiac ROIs were set using the obtained TP map. MBF was estimated by a one-compartment model analysis with the Renkin-Crone model and by the microsphere technique.

Results

The MBFs from these two methods were significantly correlated. A negative proportional bias was observed, but no significant difference was observed between the mean MBFs calculated with each method.

Conclusions

MBF estimation by a compartment model analysis using TP map could facilitate absolute MBF measurement in rats.
Appendix
Available only for authorised users
Literature
1.
go back to reference Berti V, Sciagra R, Neglia D, Pietila M, Scholte AJ, Nekolla S, et al. Segmental quantitative myocardial perfusion with PET for the detection of significant coronary artery disease in patients with stable angina. Eur J Nucl Med Mol Imaging 2016;43:1522-9.CrossRef Berti V, Sciagra R, Neglia D, Pietila M, Scholte AJ, Nekolla S, et al. Segmental quantitative myocardial perfusion with PET for the detection of significant coronary artery disease in patients with stable angina. Eur J Nucl Med Mol Imaging 2016;43:1522-9.CrossRef
2.
go back to reference Bergmann SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.CrossRef Bergmann SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.CrossRef
3.
go back to reference Schindler TH, Schelbert HR, Quercioli A, Dilsizian V. Cardiac PET imaging for the detection and monitoring of coronary artery disease and microvascular health. JACC Cardiovasc Imaging 2010;3:623-40.CrossRef Schindler TH, Schelbert HR, Quercioli A, Dilsizian V. Cardiac PET imaging for the detection and monitoring of coronary artery disease and microvascular health. JACC Cardiovasc Imaging 2010;3:623-40.CrossRef
4.
go back to reference Ben Bouallegue F, Roubille F, Lattuca B, Cung TT, Macia JC, Gervasoni R, et al. SPECT myocardial perfusion reserve in patients with multivessel coronary disease: correlation with angiographic findings and invasive fractional flow reserve measurements. J Nucl Med 2015;56:1712-7.CrossRef Ben Bouallegue F, Roubille F, Lattuca B, Cung TT, Macia JC, Gervasoni R, et al. SPECT myocardial perfusion reserve in patients with multivessel coronary disease: correlation with angiographic findings and invasive fractional flow reserve measurements. J Nucl Med 2015;56:1712-7.CrossRef
5.
go back to reference Ben-Haim S, Murthy VL, Breault C, Allie R, Sitek A, Roth N, et al. Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: a feasibility study. J Nucl Med 2013;54:873-9.CrossRef Ben-Haim S, Murthy VL, Breault C, Allie R, Sitek A, Roth N, et al. Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: a feasibility study. J Nucl Med 2013;54:873-9.CrossRef
6.
go back to reference Miyagawa M, Nishiyama Y, Uetani T, Ogimoto A, Ikeda S, Ishimura H, et al. Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: comparison with coronary angiography, fractional flow reserve, and the SYNTAX score. Int J Cardiol 2017;244:347-53.CrossRef Miyagawa M, Nishiyama Y, Uetani T, Ogimoto A, Ikeda S, Ishimura H, et al. Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: comparison with coronary angiography, fractional flow reserve, and the SYNTAX score. Int J Cardiol 2017;244:347-53.CrossRef
7.
go back to reference Nkoulou R, Fuchs TA, Pazhenkottil AP, Kuest SM, Ghadri JR, Stehli J, et al. Absolute myocardial blood flow and flow reserve assessed by gated SPECT with cadmium-zinc-telluride detectors using 99mTc-Tetrofosmin: head-to-head comparison with 13N-Ammonia PET. J Nucl Med 2016;57:1887-92.CrossRef Nkoulou R, Fuchs TA, Pazhenkottil AP, Kuest SM, Ghadri JR, Stehli J, et al. Absolute myocardial blood flow and flow reserve assessed by gated SPECT with cadmium-zinc-telluride detectors using 99mTc-Tetrofosmin: head-to-head comparison with 13N-Ammonia PET. J Nucl Med 2016;57:1887-92.CrossRef
8.
go back to reference Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D, et al. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 2015;79:623-31.CrossRef Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D, et al. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 2015;79:623-31.CrossRef
9.
go back to reference Wells RG, Marvin B, Poirier M, Renaud J, deKemp RA, Ruddy TD. Optimization of SPECT measurement of myocardial blood flow with corrections for attenuation, motion, and blood binding compared with PET. J Nucl Med 2017;58:2013-9.CrossRef Wells RG, Marvin B, Poirier M, Renaud J, deKemp RA, Ruddy TD. Optimization of SPECT measurement of myocardial blood flow with corrections for attenuation, motion, and blood binding compared with PET. J Nucl Med 2017;58:2013-9.CrossRef
10.
go back to reference Hsu B, Hu LH, Yang BH, Chen LC, Chen YK, Ting CH, et al. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with 13N-Ammonia PET myocardial blood flow quantitation. Eur J Nucl Med Mol Imaging 2017;44:117-28.CrossRef Hsu B, Hu LH, Yang BH, Chen LC, Chen YK, Ting CH, et al. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with 13N-Ammonia PET myocardial blood flow quantitation. Eur J Nucl Med Mol Imaging 2017;44:117-28.CrossRef
11.
go back to reference Shrestha U, Sciammarella M, Alhassen F, Yeghiazarians Y, Ellin J, Verdin E, et al. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: method and validation. J Nucl Cardiol 2017;24:268-77.CrossRef Shrestha U, Sciammarella M, Alhassen F, Yeghiazarians Y, Ellin J, Verdin E, et al. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: method and validation. J Nucl Cardiol 2017;24:268-77.CrossRef
12.
go back to reference Storto G, Cirillo P, Vicario ML, Pellegrino T, Sorrentino AR, Petretta M, et al. Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: comparison with the results of intracoronary Doppler technique. J Nucl Cardiol 2004;11:682-8.CrossRef Storto G, Cirillo P, Vicario ML, Pellegrino T, Sorrentino AR, Petretta M, et al. Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: comparison with the results of intracoronary Doppler technique. J Nucl Cardiol 2004;11:682-8.CrossRef
13.
go back to reference Sugihara H, Yonekura Y, Kataoka K, Fukai D, Kitamura N, Taniguchi Y. Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin. J Nucl Cardiol 2001;8:575-9.CrossRef Sugihara H, Yonekura Y, Kataoka K, Fukai D, Kitamura N, Taniguchi Y. Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin. J Nucl Cardiol 2001;8:575-9.CrossRef
14.
go back to reference Odano I, Ohkubo M, Yokoi T. Noninvasive quantification of cerebral blood flow using 99mTc-ECD and SPECT. J Nucl Med 1999;40:1737-44.PubMed Odano I, Ohkubo M, Yokoi T. Noninvasive quantification of cerebral blood flow using 99mTc-ECD and SPECT. J Nucl Med 1999;40:1737-44.PubMed
15.
go back to reference Bassingthwaighte JB. A concurrent flow model for extraction during transcapillary passage. Circ. Res 1974;35:483-503.CrossRef Bassingthwaighte JB. A concurrent flow model for extraction during transcapillary passage. Circ. Res 1974;35:483-503.CrossRef
16.
go back to reference Crone C. The permeability of capillaries in various organs as determined by use of the ‘indicator diffusion’ method. Acta Physiol Scand 1963;58:292-305.CrossRef Crone C. The permeability of capillaries in various organs as determined by use of the ‘indicator diffusion’ method. Acta Physiol Scand 1963;58:292-305.CrossRef
17.
go back to reference Renkin EM. Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. Am J Physiol 1959;197:1205-10.CrossRef Renkin EM. Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. Am J Physiol 1959;197:1205-10.CrossRef
18.
go back to reference Leppo JA, Meerdink DJ. Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ. Res 1989;65:632-9.CrossRef Leppo JA, Meerdink DJ. Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ. Res 1989;65:632-9.CrossRef
19.
go back to reference Heymann MA, Payne BD, Hoffman JI, Rudolph AM. Blood flow measurements with radionuclide-labeled particles. Prog. Cardiovasc. Dis 1977;20:55-79.CrossRef Heymann MA, Payne BD, Hoffman JI, Rudolph AM. Blood flow measurements with radionuclide-labeled particles. Prog. Cardiovasc. Dis 1977;20:55-79.CrossRef
20.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London, England) 1986;1:307-310. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London, England) 1986;1:307-310.
21.
go back to reference Conzen PF, Vollmar B, Habazettl H, Frink EJ, Peter K, Messmer K. Systemic and regional hemodynamics of isoflurane and sevoflurane in rats. Anesth. Analg 1992;74:79-88.CrossRef Conzen PF, Vollmar B, Habazettl H, Frink EJ, Peter K, Messmer K. Systemic and regional hemodynamics of isoflurane and sevoflurane in rats. Anesth. Analg 1992;74:79-88.CrossRef
22.
go back to reference Croteau E, Benard F, Bentourkia M, Rousseau J, Paquette M, Lecomte R. Quantitative myocardial perfusion and coronary reserve in rats with 13N-ammonia and small animal PET: impact of anesthesia and pharmacologic stress agents. J Nucl Med 2004;45:1924-30.PubMed Croteau E, Benard F, Bentourkia M, Rousseau J, Paquette M, Lecomte R. Quantitative myocardial perfusion and coronary reserve in rats with 13N-ammonia and small animal PET: impact of anesthesia and pharmacologic stress agents. J Nucl Med 2004;45:1924-30.PubMed
23.
go back to reference Debaene B, Goldfarb G, Braillon A, Jolis P, Lebrec D. Effects of ketamine, halothane, enflurane, and isoflurane on systemic and splanchnic hemodynamics in normovolemic and hypovolemic cirrhotic rats. Anesthesiology 1990;73:118-24.CrossRef Debaene B, Goldfarb G, Braillon A, Jolis P, Lebrec D. Effects of ketamine, halothane, enflurane, and isoflurane on systemic and splanchnic hemodynamics in normovolemic and hypovolemic cirrhotic rats. Anesthesiology 1990;73:118-24.CrossRef
24.
go back to reference Gervais M, Demolis P, Domergue V, Lesage M, Richer C, Giudicelli JF. Systemic and regional hemodynamics assessment in rats with fluorescent microspheres. J Cardiovasc Pharmacol 1999;33:425-32.CrossRef Gervais M, Demolis P, Domergue V, Lesage M, Richer C, Giudicelli JF. Systemic and regional hemodynamics assessment in rats with fluorescent microspheres. J Cardiovasc Pharmacol 1999;33:425-32.CrossRef
25.
go back to reference Ishise S, Pegram BL, Yamamoto J, Kitamura Y, Frohlich ED. Reference sample microsphere method: cardiac output and blood flows in conscious rat. Am J Physiol 1980;239:H443-h9. Ishise S, Pegram BL, Yamamoto J, Kitamura Y, Frohlich ED. Reference sample microsphere method: cardiac output and blood flows in conscious rat. Am J Physiol 1980;239:H443-h9.
26.
go back to reference Wang X, Li F, Said S, Capasso JM, Gerdes AM. Measurement of regional myocardial blood flow in rats by unlabeled microspheres and Coulter channelyzer. Am J Physiol 1996;271:H1656-65.PubMed Wang X, Li F, Said S, Capasso JM, Gerdes AM. Measurement of regional myocardial blood flow in rats by unlabeled microspheres and Coulter channelyzer. Am J Physiol 1996;271:H1656-65.PubMed
27.
go back to reference Glover DK, Okada RD. Myocardial kinetics of Tc-MIBI in canine myocardium after dipyridamole. Circulation 1990;81:628-37.CrossRef Glover DK, Okada RD. Myocardial kinetics of Tc-MIBI in canine myocardium after dipyridamole. Circulation 1990;81:628-37.CrossRef
28.
go back to reference De Bondt P, Van de Wiele C, De Sutter J, De Winter F, De Backer G, Dierckx RA. Age- and gender-specific differences in left ventricular cardiac function and volumes determined by gated SPET. Eur J Nucl Med 2001;28:620-4.CrossRef De Bondt P, Van de Wiele C, De Sutter J, De Winter F, De Backer G, Dierckx RA. Age- and gender-specific differences in left ventricular cardiac function and volumes determined by gated SPET. Eur J Nucl Med 2001;28:620-4.CrossRef
29.
go back to reference Ford PV, Chatziioannou SN, Moore WH, Dhekne RD. Overestimation of the LVEF by quantitative gated SPECT in simulated left ventricles. J Nucl Med 2001;42:454-9.PubMed Ford PV, Chatziioannou SN, Moore WH, Dhekne RD. Overestimation of the LVEF by quantitative gated SPECT in simulated left ventricles. J Nucl Med 2001;42:454-9.PubMed
30.
go back to reference Hambye AS, Vervaet A, Dobbeleir A. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts. Eur J Nucl Med Mol Imaging 2004;31:1606-13.CrossRef Hambye AS, Vervaet A, Dobbeleir A. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts. Eur J Nucl Med Mol Imaging 2004;31:1606-13.CrossRef
Metadata
Title
Noninvasive estimation of quantitative myocardial blood flow with Tc-99m MIBI by a compartment model analysis in rat
Authors
Atsutaka Okizaki, MD, PhD
Michihiro Nakayama, MD, PhD
Kaori Nakajima, MD
Osuke Fujimoto, DVM
Shinobu Oshikiri, MS
Miho Koike-Satake, MS
Yuto Nakahara, MS
Publication date
01-08-2020
Publisher
Springer International Publishing
Published in
Journal of Nuclear Cardiology / Issue 4/2020
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-018-1274-z

Other articles of this Issue 4/2020

Journal of Nuclear Cardiology 4/2020 Go to the issue