Skip to main content
Top
Published in: Antimicrobial Resistance & Infection Control 1/2018

Open Access 01-12-2018 | Research

Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission

Authors: Lorna K. P. Suen, Yue Ping Guo, Danny W. K. Tong, Polly H. M. Leung, David Lung, Mandy S. P. Ng, Timothy K. H. Lai, Kiki Y. K. Lo, Cypher H. Au-Yeung, Winnie Yu

Published in: Antimicrobial Resistance & Infection Control | Issue 1/2018

Login to get access

Abstract

Background

Healthcare workers (HCWs) use personal protective equipment (PPE) in Ebola virus disease (EVD) situations. However, preventing the contamination of HCWs and the environment during PPE removal crucially requires improved strategies. This study aimed to compare the efficacy of three PPE ensembles, namely, Hospital Authority (HA) Standard Ebola PPE set (PPE1), Dupont Tyvek Model, style 1422A (PPE2), and HA isolation gown for routine patient care and performing aerosol-generating procedures (PPE3) to prevent EVD transmission by measuring the degree of contamination of HCWs and the environment.

Methods

A total of 59 participants randomly performed PPE donning and doffing. The trial consisted of PPE donning, applying fluorescent solution on the PPE surface, PPE doffing of participants, and estimation of the degree of contamination as indicated by the number of fluorescent stains on the working clothes and environment. Protocol deviations during PPE donning and doffing were monitored.

Results

PPE2 and PPE3 presented higher contamination risks than PPE1. Environmental contaminations such as those originating from rubbish bin covers, chairs, faucets, and sinks were detected. Procedure deviations were observed during PPE donning and doffing, with PPE1 presenting the lowest overall deviation rate (%) among the three PPE ensembles (p < 0.05).

Conclusion

Contamination of the subjects’ working clothes and surrounding environment occurred frequently during PPE doffing. Procedure deviations were observed during PPE donning and doffing. Although PPE1 presented a lower contamination risk than PPE2 and PPE3 during doffing and protocol deviations, the design of PPE1 can still be further improved. Future directions should focus on designing a high-coverage-area PPE with simple ergonomic features and on evaluating the doffing procedure to minimise the risk of recontamination. Regular training for users should be emphasised to minimise protocol deviations, and in turn, guarantee the best protection to HCWs.
Appendix
Available only for authorised users
Literature
3.
go back to reference Lim SM, Cha WC, Chae MK, Jo IJ. Contamination during doffing of personal protective equipment by healthcare providers. Clin Exp Emerg Med. 2015;2(3):162–7.CrossRefPubMedPubMedCentral Lim SM, Cha WC, Chae MK, Jo IJ. Contamination during doffing of personal protective equipment by healthcare providers. Clin Exp Emerg Med. 2015;2(3):162–7.CrossRefPubMedPubMedCentral
4.
go back to reference Bell T, Smoot J, Patterson J, Smalligan R, Jordan R. Ebola virus disease: the use of fluorescents as markers of contamination for personal protective equipment. ID Cases. 2015;2:27–30.PubMed Bell T, Smoot J, Patterson J, Smalligan R, Jordan R. Ebola virus disease: the use of fluorescents as markers of contamination for personal protective equipment. ID Cases. 2015;2:27–30.PubMed
5.
go back to reference Centers for Disease Control and Prevention: Guidance on Personal Protective Equipment (PPE) To Be Used By Healthcare Workers during Management of Patients with Confirmed Ebola or Persons under Investigation (PUIs) for Ebola who are Clinically Unstable or Have Bleeding, Vomiting, or Diarrhea in U.S. Hospitals, Including Procedures for Donning and Doffing PPE. 2015. https://www.cdc.gov/vhf/ebola/healthcare-us/ppe/guidance.html. Centers for Disease Control and Prevention: Guidance on Personal Protective Equipment (PPE) To Be Used By Healthcare Workers during Management of Patients with Confirmed Ebola or Persons under Investigation (PUIs) for Ebola who are Clinically Unstable or Have Bleeding, Vomiting, or Diarrhea in U.S. Hospitals, Including Procedures for Donning and Doffing PPE. 2015. https://​www.​cdc.​gov/​vhf/​ebola/​healthcare-us/​ppe/​guidance.​html.
6.
go back to reference Casanova LM, Rutala WA, Weber DJ, Sobsey MD. Effect of single- versus double-gloving on virus transfer to health care workers’ skin and clothing during removal of personal protective equipment. Am J Infect Control. 2012;40:369–74.CrossRefPubMed Casanova LM, Rutala WA, Weber DJ, Sobsey MD. Effect of single- versus double-gloving on virus transfer to health care workers’ skin and clothing during removal of personal protective equipment. Am J Infect Control. 2012;40:369–74.CrossRefPubMed
8.
go back to reference Guo YP, Li Y, Wong PL. Environment and body contamination: a comparison of two different removal methods in three types of personal protective clothing. Am J Infect Control. 2014;42(4):e39–45.CrossRefPubMedPubMedCentral Guo YP, Li Y, Wong PL. Environment and body contamination: a comparison of two different removal methods in three types of personal protective clothing. Am J Infect Control. 2014;42(4):e39–45.CrossRefPubMedPubMedCentral
9.
go back to reference Wong TKS, Chung JWY, Li Y, Chan WF, Ching PTY, Lam CHS, Chow CH. Effective personal protective clothing (PPC) for healthcare workers attending patients with severe acute respiratory syndrome (SARS). Am J Infect Control. 2004;32:90–6.CrossRefPubMedPubMedCentral Wong TKS, Chung JWY, Li Y, Chan WF, Ching PTY, Lam CHS, Chow CH. Effective personal protective clothing (PPC) for healthcare workers attending patients with severe acute respiratory syndrome (SARS). Am J Infect Control. 2004;32:90–6.CrossRefPubMedPubMedCentral
13.
go back to reference Lai JY, Guo YP, Or PP, Li Y. Comparison of hand contamination rates and environmental contamination levels between two different glove removal methods and distances. Am J Infect Control. 2011;39(2):104–11.CrossRefPubMed Lai JY, Guo YP, Or PP, Li Y. Comparison of hand contamination rates and environmental contamination levels between two different glove removal methods and distances. Am J Infect Control. 2011;39(2):104–11.CrossRefPubMed
15.
go back to reference Edmond MB, Diekema DJ, Perencevich EN. Ebola virus disease and the need for new personal protective equipment. JAMA. 2014;312(23):2495–6.CrossRefPubMed Edmond MB, Diekema DJ, Perencevich EN. Ebola virus disease and the need for new personal protective equipment. JAMA. 2014;312(23):2495–6.CrossRefPubMed
16.
17.
go back to reference Kang JK, O’Donnell JM, Colaianne B, Bircher N, Ren D, Smith KJ. Use of personal protective equipment among health care personnel: results of clinical observations and simulations. Am J Infect Control. 2017;45:17–23.CrossRefPubMed Kang JK, O’Donnell JM, Colaianne B, Bircher N, Ren D, Smith KJ. Use of personal protective equipment among health care personnel: results of clinical observations and simulations. Am J Infect Control. 2017;45:17–23.CrossRefPubMed
18.
go back to reference Casanova L, Alfano-Sobsey E, Rutala WA, Weber DJ, Sobsey M. Virus transfer from personal protective equipment to healthcare employees’ skin and clothing. Emerg Infect Dis. 2008;14(8):1291–3.CrossRefPubMedPubMedCentral Casanova L, Alfano-Sobsey E, Rutala WA, Weber DJ, Sobsey M. Virus transfer from personal protective equipment to healthcare employees’ skin and clothing. Emerg Infect Dis. 2008;14(8):1291–3.CrossRefPubMedPubMedCentral
19.
go back to reference Tomas ME, Kundrapu S, Thota P, Sunkesula VCK, Cadnum JF, Mana TSC, Jencson A, O’Donnell M, Zabarsky TF, Hecker MT, Ray AJ, Wilson BM, Donskey CJ. Contamination of health care personnel during removal of personal protective equipment. JAMA Intern Med. 2015;175(12):1904–10.CrossRefPubMed Tomas ME, Kundrapu S, Thota P, Sunkesula VCK, Cadnum JF, Mana TSC, Jencson A, O’Donnell M, Zabarsky TF, Hecker MT, Ray AJ, Wilson BM, Donskey CJ. Contamination of health care personnel during removal of personal protective equipment. JAMA Intern Med. 2015;175(12):1904–10.CrossRefPubMed
20.
go back to reference Kwon JH, Burnham CD, Reske KA, Liang SY, Hink T, Wallace MA, Shupe A, Seiler S, Cass C, Fraser VJ, Dubberke ER. MSPH for the CDC prevention epicenters. Assessment of healthcare worker protocol deviations and self-contamination during personal protective equipment donning and doffing. Infect Control Hosp Epidemiol. 2017;38(9):1077–83.CrossRefPubMedPubMedCentral Kwon JH, Burnham CD, Reske KA, Liang SY, Hink T, Wallace MA, Shupe A, Seiler S, Cass C, Fraser VJ, Dubberke ER. MSPH for the CDC prevention epicenters. Assessment of healthcare worker protocol deviations and self-contamination during personal protective equipment donning and doffing. Infect Control Hosp Epidemiol. 2017;38(9):1077–83.CrossRefPubMedPubMedCentral
21.
go back to reference Hall S, Poller B, Bailey C, Gregory S, Clark R, Roberts P, Tunbridge A, Poran V, Evans C, Crook B. Use of ultraviolet-fluorescence-based simulation in evaluation of personal protective equipment worn for first assessment and care of a patient with suspected high-consequence infectious disease. J Hosp Infect. 2018;99(2018):218–28.CrossRefPubMed Hall S, Poller B, Bailey C, Gregory S, Clark R, Roberts P, Tunbridge A, Poran V, Evans C, Crook B. Use of ultraviolet-fluorescence-based simulation in evaluation of personal protective equipment worn for first assessment and care of a patient with suspected high-consequence infectious disease. J Hosp Infect. 2018;99(2018):218–28.CrossRefPubMed
22.
go back to reference Herlihey TA, Gelmi S, Flewwelling CJ, Hall TNT, BEng CB, Morita PP, Beverley P, Cafaxxo JA, Hota S. Personal protective equipment for infectious disease preparedness: a human factors evaluation. Infect Control Hosp Epidemiol. 2016;37:1022–8.CrossRefPubMed Herlihey TA, Gelmi S, Flewwelling CJ, Hall TNT, BEng CB, Morita PP, Beverley P, Cafaxxo JA, Hota S. Personal protective equipment for infectious disease preparedness: a human factors evaluation. Infect Control Hosp Epidemiol. 2016;37:1022–8.CrossRefPubMed
23.
go back to reference Casanova LM, Teal LJ, Sickbert-Bennett EE, Anderson DJ, Sexton DJ, Rutala WA, Weber DJ. The CDC prevention epicenters program: assessment of self-contamination during removal of personal protective equipment for Ebola patient care. Infect Control Hosp Epidemiol. 2016;37(10):1156–61.CrossRefPubMed Casanova LM, Teal LJ, Sickbert-Bennett EE, Anderson DJ, Sexton DJ, Rutala WA, Weber DJ. The CDC prevention epicenters program: assessment of self-contamination during removal of personal protective equipment for Ebola patient care. Infect Control Hosp Epidemiol. 2016;37(10):1156–61.CrossRefPubMed
24.
go back to reference Centre for Health Protection. Infection Control Recommendation for Ebola Virus Disease (EVD) in Healthcare Settings. Hong Kong: Centre for Health Protection; 2014 (Last updated on 11 July 2016). Centre for Health Protection. Infection Control Recommendation for Ebola Virus Disease (EVD) in Healthcare Settings. Hong Kong: Centre for Health Protection; 2014 (Last updated on 11 July 2016).
26.
go back to reference Clay KA, O’Shea MK, Fletcher T, Moore AJ, Burns DS, Craig D, Adam M, Johnston AM, Bailey MS, Gibson C. Use of an ultraviolet tracer in simulation training for the clinical management of Ebola virus disease. J Hosp Infect. 2015;91(3):275–7.CrossRefPubMed Clay KA, O’Shea MK, Fletcher T, Moore AJ, Burns DS, Craig D, Adam M, Johnston AM, Bailey MS, Gibson C. Use of an ultraviolet tracer in simulation training for the clinical management of Ebola virus disease. J Hosp Infect. 2015;91(3):275–7.CrossRefPubMed
27.
go back to reference Poller B, Hall S, Bailey C, Gregory S, Clark R, Roberts P, Tunbridge A, Poran V, Crook B, Evans C. ‘VIOLET’: a fluorescence-based simulation exercise for training healthcare workers in the use of personal protective equipment. J Hosp Infect. 2018;99(2018):229–35.CrossRefPubMedPubMedCentral Poller B, Hall S, Bailey C, Gregory S, Clark R, Roberts P, Tunbridge A, Poran V, Crook B, Evans C. ‘VIOLET’: a fluorescence-based simulation exercise for training healthcare workers in the use of personal protective equipment. J Hosp Infect. 2018;99(2018):229–35.CrossRefPubMedPubMedCentral
Metadata
Title
Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission
Authors
Lorna K. P. Suen
Yue Ping Guo
Danny W. K. Tong
Polly H. M. Leung
David Lung
Mandy S. P. Ng
Timothy K. H. Lai
Kiki Y. K. Lo
Cypher H. Au-Yeung
Winnie Yu
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Antimicrobial Resistance & Infection Control / Issue 1/2018
Electronic ISSN: 2047-2994
DOI
https://doi.org/10.1186/s13756-018-0433-y

Other articles of this Issue 1/2018

Antimicrobial Resistance & Infection Control 1/2018 Go to the issue