Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2017

Open Access 01-12-2017 | Case report

Double localization of a non-anastomotic pseudoaneurysm after an axillofemoral bypass: a case report and review of the literature

Authors: Badr Bensaid, Tarek Bakkali, Youssef Tijani, Samir Elkhalloufi, Brahim Lekehal, Yassir Sefiani, Abess El Mesnaoui, Younes Bensaid

Published in: Journal of Medical Case Reports | Issue 1/2017

Login to get access

Abstract

Background

A traumatic non-anastomotic pseudoaneurysm is a rare complication of an axillofemoral bypass graft. Fewer than 20 cases have been reported in the literature. Our case is unusual in that we report a double localization of this complication.

Case presentation

We report the case of a 60-year-old Arabic male patient who was diagnosed with two hematomas in the trajectory of his axillofemoral bypass secondary to a traumatism. The diagnosis of a non-anastomotic pseudoaneurysm was retained considering the results of a computed tomography angiography scan, which showed the double localization of the pseudoaneurysm. Surgical management consisted of flattening the pseudoaneurysm along with the interposition of a prosthetic segment. There were no postoperative complications and our patient was well 3 years after discharge.

Conclusions

Non-anastomotic pseudoaneurysm is a rarely described complication of a axillofemoral bypass graft. To the best of our knowledge, a double localization has not been described in the literature before. Minimally invasive techniques as a treatment option are being widely used as an alternative to open repair.
Literature
1.
go back to reference Blaisdell FW, Hall AD. Axillary-femoral artery bypass for lower extremity ischemia. Surgery. 1963;54:563–8.PubMed Blaisdell FW, Hall AD. Axillary-femoral artery bypass for lower extremity ischemia. Surgery. 1963;54:563–8.PubMed
2.
go back to reference Taylor Jr LM, Park TC, Edwards JM, et al. Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses: a complication of axillofemoral grafting. J Vasc Surg. 1994;20(4):520–6.CrossRefPubMed Taylor Jr LM, Park TC, Edwards JM, et al. Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses: a complication of axillofemoral grafting. J Vasc Surg. 1994;20(4):520–6.CrossRefPubMed
3.
go back to reference Yeager RA, Taylor Jr LM. Axillary artery anastomosis to avoid axillofemoral bypass disruption. Semin Vasc Surg. 2000;13(1):74–6.PubMed Yeager RA, Taylor Jr LM. Axillary artery anastomosis to avoid axillofemoral bypass disruption. Semin Vasc Surg. 2000;13(1):74–6.PubMed
4.
go back to reference Piazza D, Ameli FM, von Schroeder HP, et al. Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft. J Vasc Surg. 1993;17(4):777–9.CrossRefPubMed Piazza D, Ameli FM, von Schroeder HP, et al. Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft. J Vasc Surg. 1993;17(4):777–9.CrossRefPubMed
5.
go back to reference Oz BS, Yilmaz AT, Gunay C, et al. True aneurysm formation in axillofemoral bypass with a reinforced Eptfe graft-a case report. Vasc Endovascular Surg. 2002;36(4):327–9.CrossRefPubMed Oz BS, Yilmaz AT, Gunay C, et al. True aneurysm formation in axillofemoral bypass with a reinforced Eptfe graft-a case report. Vasc Endovascular Surg. 2002;36(4):327–9.CrossRefPubMed
6.
go back to reference Mousa AY, Nanjundappa A, Abu-Halimah S, et al. Traumatic nonanastomotic pseudoaneurysm of axillofemoral bypass graft: a case report and review of the literature. Vasc Endovascular Surg. 2013;47(1):57–60.CrossRefPubMed Mousa AY, Nanjundappa A, Abu-Halimah S, et al. Traumatic nonanastomotic pseudoaneurysm of axillofemoral bypass graft: a case report and review of the literature. Vasc Endovascular Surg. 2013;47(1):57–60.CrossRefPubMed
7.
go back to reference Liedenbaum MH, Verdam FJ, Spelt D, et al. The outcome of the axillofemoral bypass: a retrospective analysis of 45 patients. World J Surg. 2009;33(11):2490–6.CrossRefPubMedPubMedCentral Liedenbaum MH, Verdam FJ, Spelt D, et al. The outcome of the axillofemoral bypass: a retrospective analysis of 45 patients. World J Surg. 2009;33(11):2490–6.CrossRefPubMedPubMedCentral
8.
go back to reference Taylor Jr LM, Moneta GL, McConnell D, et al. Axillofemoral grafting with externally supported polytetrafluoroethylene. Arch Surg. 1994;129(6):588–94.CrossRefPubMed Taylor Jr LM, Moneta GL, McConnell D, et al. Axillofemoral grafting with externally supported polytetrafluoroethylene. Arch Surg. 1994;129(6):588–94.CrossRefPubMed
9.
go back to reference Schneider JR, McDaniel MD, Walsh DB, et al. Axillofemoral bypass: outcome and hemodynamic results in high-risk patients. J Vasc Surg. 1992;15(6):952–62.CrossRefPubMed Schneider JR, McDaniel MD, Walsh DB, et al. Axillofemoral bypass: outcome and hemodynamic results in high-risk patients. J Vasc Surg. 1992;15(6):952–62.CrossRefPubMed
10.
go back to reference Ylönen K, Biancari F, Leo E, et al. Predictors of development of anastomotic femoral pseudoaneurysms after aortobifemoral reconstruction for abdominal aortic aneurysm. Am J Surg. 2004;187(1):83–7.CrossRefPubMed Ylönen K, Biancari F, Leo E, et al. Predictors of development of anastomotic femoral pseudoaneurysms after aortobifemoral reconstruction for abdominal aortic aneurysm. Am J Surg. 2004;187(1):83–7.CrossRefPubMed
11.
go back to reference Gherman C, Mironiuc A, Olinic D, et al. Aortic anastamotic pseudoaneurysm. a complication of abdominal aortic surgery. Timisoara Med J. 2003;53(3–4):279–82. Gherman C, Mironiuc A, Olinic D, et al. Aortic anastamotic pseudoaneurysm. a complication of abdominal aortic surgery. Timisoara Med J. 2003;53(3–4):279–82.
12.
go back to reference Anthony Yuk-Wai Wu, Wissam Al-Jundi, Zehra Ziadi, Mohamed Barkat, Amjad Khushal. Huge anastomotic femoral pseudoaneurysm following aorto-bifemoral bypass. BMJ Case Reports 2011; doi: 10.1136/bcr.07.2010.3160. Anthony Yuk-Wai Wu, Wissam Al-Jundi, Zehra Ziadi, Mohamed Barkat, Amjad Khushal. Huge anastomotic femoral pseudoaneurysm following aorto-bifemoral bypass. BMJ Case Reports 2011; doi: 10.​1136/​bcr.​07.​2010.​3160.
13.
go back to reference Daar AS, Finch RA. Graft avulsion: an unreported complication of axillofemoral bypass grafts. Br J Surg. 1978;65(6):442.CrossRefPubMed Daar AS, Finch RA. Graft avulsion: an unreported complication of axillofemoral bypass grafts. Br J Surg. 1978;65(6):442.CrossRefPubMed
14.
go back to reference Huang CK, Lu MS, Chang JP, et al. Axillary anastomotic disruption after axillofemoral bypass. J Emerg Med. 2007;32(3):305–7.CrossRefPubMed Huang CK, Lu MS, Chang JP, et al. Axillary anastomotic disruption after axillofemoral bypass. J Emerg Med. 2007;32(3):305–7.CrossRefPubMed
15.
go back to reference Buche M, Noirhomme P, Devaux P, et al. Posttraumatic false aneurysm of axillofemoral bypass graft. J Vasc Surg. 1992;16(3):498–500.CrossRefPubMed Buche M, Noirhomme P, Devaux P, et al. Posttraumatic false aneurysm of axillofemoral bypass graft. J Vasc Surg. 1992;16(3):498–500.CrossRefPubMed
16.
go back to reference Kruger K, Landwehr P, Kristen F, et al. Unusual pseudoaneurysm of an axillofemoral bypass caused by seat belt trauma: case report. J Trauma. 1999;46(1):189–91.CrossRefPubMed Kruger K, Landwehr P, Kristen F, et al. Unusual pseudoaneurysm of an axillofemoral bypass caused by seat belt trauma: case report. J Trauma. 1999;46(1):189–91.CrossRefPubMed
17.
go back to reference Grochow RM, Raffetto JD. Chronic traumatic pseudoaneurysm of polytetrafluoroethylene axillofemoral bypass graft in a quadriplegic patient. Ann Vasc Surg. 2008;22(5):688–91.CrossRefPubMed Grochow RM, Raffetto JD. Chronic traumatic pseudoaneurysm of polytetrafluoroethylene axillofemoral bypass graft in a quadriplegic patient. Ann Vasc Surg. 2008;22(5):688–91.CrossRefPubMed
18.
go back to reference Shibutani S, Obara H, Kakefuda T, et al. Nonanastomotic pseudoaneurysm with complete disruption of an expanded polytetrafluoroethylene axillofemoral bypass graft. Ann Vasc Surg. 2012;26(3):422. e9–422.e12.CrossRefPubMed Shibutani S, Obara H, Kakefuda T, et al. Nonanastomotic pseudoaneurysm with complete disruption of an expanded polytetrafluoroethylene axillofemoral bypass graft. Ann Vasc Surg. 2012;26(3):422. e9–422.e12.CrossRefPubMed
Metadata
Title
Double localization of a non-anastomotic pseudoaneurysm after an axillofemoral bypass: a case report and review of the literature
Authors
Badr Bensaid
Tarek Bakkali
Youssef Tijani
Samir Elkhalloufi
Brahim Lekehal
Yassir Sefiani
Abess El Mesnaoui
Younes Bensaid
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2017
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-016-1149-3

Other articles of this Issue 1/2017

Journal of Medical Case Reports 1/2017 Go to the issue