Published in: BMC Musculoskeletal Disorders 1/2020

Open Access 01-12-2020 | Research article

How to get better TAD? Relationship between anteversion angle of nail and position of femoral neck guide pin during nailing of intertrochanteric fractures

Authors: Zhe Wang, Yadong Liu, Shenglong Li, Xiuhui Wang, Changjian Liu, Xin Tang

Published in: BMC Musculoskeletal Disorders | Issue 1/2020

Login to get access

Abstract

Background

To demonstrate the correlation between guide pin-shaft angle (PSA) at the anteroposterior film and anteversion angle of guide pin at the lateral film and investigate whether excellent tip–apex distance (TAD) can be obtained by changing the entry point via axial rotation of the main intramedullary nail.

Methods

Fifty patients with intertrochanteric femoral fractures (IFFs) undergoing internal fixation with intramedullary nails under 2D fluoroscopy were retrospectively enrolled. Both of the PSA at the anteroposterior film and anteversion angle at the lateral film before and after adjustment of the guide pin were collected. Pearson correlation analysis was performed to investigate their correlation. Intraoperative and postoperative outcomes were recorded. Furthermore, the software of Mimics 10.0 and Pro/E were used to establish the 3D models of the proximal femur and main intramedullary nail/guide pin, respectively. Surgery was simulated on the Pro/E software platform and solid geometry analysis was conducted to calculate the correlation between the PSA and the anteversion angle.

Results

Pearson correlation analysis indicated there was a positive correlation between PSA and anteversion angle, with the correlation coefficient of 0.902 (p < 0.01). By altering the PSA and anteversion angle, TAD was adjusted to be less than 25 mm in all patients. The mean operative time, fluoroscopy time and length of hospital stay were 65.82 ± 11.16 min, 2.03 ± 0.79 min and 6.66 ± 2.49 d. Thirty-one patients received blood transfusions (3.55 ± 1.95 U). Fracture reduction was considered to be good or acceptable in all patients. Complications occurred only in 6 patients (12.00%). At a 3-month follow-up, the mean Timed Up and Go was 31.54 ± 20.95 s and Harris Hip Score was 72.88 ± 8.79. The 3D surgery model also showed when the main intramedullary nail was externally rotated or internally rotated of 20° at the standard location, the PSA of guide pin at the anteroposterior position and anteversion angle of the guide pin at the lateral position were simultaneously increased or decreased.

Conclusion

Our findings suggest altering the PSA and anteversion angle may be beneficial for obtaining excellent TAD and achieving superior outcomes.
Appendix
Available only for authorised users
Literature
1.
go back to reference Thacker SB, Branche C, Stevens JA, Olson S. Reducing falls and resulting hip fractures among older women. Home Care Provid. 2000;5:134–41.CrossRef Thacker SB, Branche C, Stevens JA, Olson S. Reducing falls and resulting hip fractures among older women. Home Care Provid. 2000;5:134–41.CrossRef
2.
go back to reference Yoon BH, Lee YK, Kim SC, Kim SH, Ha YC, Koo KH. Epidemiology of proximal femoral fractures in South Korea. Arch Osteoporos. 2013;8:157.CrossRef Yoon BH, Lee YK, Kim SC, Kim SH, Ha YC, Koo KH. Epidemiology of proximal femoral fractures in South Korea. Arch Osteoporos. 2013;8:157.CrossRef
3.
go back to reference Gullberg B, Johnell O, Kanis JA. World-wide projections for hip fracture. Osteoporos Int. 1997;7:407–13.CrossRef Gullberg B, Johnell O, Kanis JA. World-wide projections for hip fracture. Osteoporos Int. 1997;7:407–13.CrossRef
4.
go back to reference Li AB, Zhang WJ, Wang J, Guo WJ, Wang XH, Zhao YM. Intramedullary and extramedullary fixations for the treatment of unstable femoral intertrochanteric fractures: a meta-analysis of prospective randomized controlled trials. Int Orthop. 2017;41:403–13.CrossRef Li AB, Zhang WJ, Wang J, Guo WJ, Wang XH, Zhao YM. Intramedullary and extramedullary fixations for the treatment of unstable femoral intertrochanteric fractures: a meta-analysis of prospective randomized controlled trials. Int Orthop. 2017;41:403–13.CrossRef
5.
go back to reference Lee YK, Chung CY, Park MS, Lee KM, Koo KH. Intramedullary nail versus extramedullary plate fixation for unstable intertrochanteric fractures: decision analysis. Arch Orthop Trauma Surg. 2013;133:961–8.CrossRef Lee YK, Chung CY, Park MS, Lee KM, Koo KH. Intramedullary nail versus extramedullary plate fixation for unstable intertrochanteric fractures: decision analysis. Arch Orthop Trauma Surg. 2013;133:961–8.CrossRef
6.
go back to reference Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J, Luan HX, Yang F, Zheng H, He SJ. Proximal femoral nails antirotation, gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res. 2014;100:859–66.CrossRef Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J, Luan HX, Yang F, Zheng H, He SJ. Proximal femoral nails antirotation, gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res. 2014;100:859–66.CrossRef
7.
go back to reference Wu D, Ren G, Peng C, Zheng X, Mao F, Zhang Y. InterTan nail versus Gamma3 nail for intramedullary nailing of unstable trochanteric fractures. Diagn Pathol. 2014;9:191.CrossRef Wu D, Ren G, Peng C, Zheng X, Mao F, Zhang Y. InterTan nail versus Gamma3 nail for intramedullary nailing of unstable trochanteric fractures. Diagn Pathol. 2014;9:191.CrossRef
8.
go back to reference Ma JX, Kuang MJ, Fan ZR, Xing F, Zhao YL, Zhang LK, Chen HT, Han C, Ma XL. Comparison of clinical outcomes with InterTan vs gamma nail or PFNA in the treatment of intertrochanteric fractures: a meta-analysis. Sci Rep. 2017;7:15962.CrossRef Ma JX, Kuang MJ, Fan ZR, Xing F, Zhao YL, Zhang LK, Chen HT, Han C, Ma XL. Comparison of clinical outcomes with InterTan vs gamma nail or PFNA in the treatment of intertrochanteric fractures: a meta-analysis. Sci Rep. 2017;7:15962.CrossRef
9.
go back to reference Li S, Chang SM, Niu WX, Ma H. Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis. J Orthop Sci. 2015;20:1062–9.CrossRef Li S, Chang SM, Niu WX, Ma H. Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis. J Orthop Sci. 2015;20:1062–9.CrossRef
10.
go back to reference Kraus M, Krischak G, Wiedmann K, Riepl C, Gebhard F, Jöckel JA, Scola A. Clinical evaluation of PFNA® and relationship between the tip-apex distance and mechanical failure. Unfallchirurg. 2011;114:470–8.CrossRef Kraus M, Krischak G, Wiedmann K, Riepl C, Gebhard F, Jöckel JA, Scola A. Clinical evaluation of PFNA® and relationship between the tip-apex distance and mechanical failure. Unfallchirurg. 2011;114:470–8.CrossRef
11.
go back to reference Flores SAWA, Caroom C, Jenkins M. The utility of the tip-apex distance in predicting axial migration and cutout with the trochanteric fixation nail system helical blade. J Orthop Trauma. 2016;30:e207–11.PubMed Flores SAWA, Caroom C, Jenkins M. The utility of the tip-apex distance in predicting axial migration and cutout with the trochanteric fixation nail system helical blade. J Orthop Trauma. 2016;30:e207–11.PubMed
12.
go back to reference Yang JC, Chen HC, Lai YS, Cheng CK. Measurement of tip apex distance and migration of lag screws and novel blade screw used for the fixation of intertrochanteric fractures. PLoS One. 2017;12:e0170048.CrossRef Yang JC, Chen HC, Lai YS, Cheng CK. Measurement of tip apex distance and migration of lag screws and novel blade screw used for the fixation of intertrochanteric fractures. PLoS One. 2017;12:e0170048.CrossRef
13.
go back to reference Yam M, Chawla A, Kwek E. Rewriting the tip apex distance for the proximal femoral nail anti-rotation. Injury. 2017;48:1843–7.CrossRef Yam M, Chawla A, Kwek E. Rewriting the tip apex distance for the proximal femoral nail anti-rotation. Injury. 2017;48:1843–7.CrossRef
14.
go back to reference Regling M, Blau A, Probe RA, Maxey JW, Solberg BD. Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study. BMC Musculoskelet Disord. 2014;15:189.CrossRef Regling M, Blau A, Probe RA, Maxey JW, Solberg BD. Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study. BMC Musculoskelet Disord. 2014;15:189.CrossRef
15.
go back to reference Johnson LJ, Cope MR, Shahrokhi S, Tamblyn P. Measuring tip-apex distance using a picture archiving and communication system (PACS). Injury. 2008;39:786–90.CrossRef Johnson LJ, Cope MR, Shahrokhi S, Tamblyn P. Measuring tip-apex distance using a picture archiving and communication system (PACS). Injury. 2008;39:786–90.CrossRef
16.
go back to reference Quah C, Mehta R, Shivji FS, Hassan S, Chandrasenan J, Moran CG, Forward DP. The effect of surgical experience on the amount of radiation exposure from fluoroscopy during dynamic hip screw fixation. Ann R Coll Surg Engl. 2017;99:198–202.CrossRef Quah C, Mehta R, Shivji FS, Hassan S, Chandrasenan J, Moran CG, Forward DP. The effect of surgical experience on the amount of radiation exposure from fluoroscopy during dynamic hip screw fixation. Ann R Coll Surg Engl. 2017;99:198–202.CrossRef
17.
go back to reference Sakagoshi D, Sawaguchi T, Shima Y, Inoue D, Oshima T, Goldhahn S. A refined definition improves the measurement reliability of the tip-apex distance. J Orthop Sci. 2016;21:475–80.CrossRef Sakagoshi D, Sawaguchi T, Shima Y, Inoue D, Oshima T, Goldhahn S. A refined definition improves the measurement reliability of the tip-apex distance. J Orthop Sci. 2016;21:475–80.CrossRef
18.
go back to reference Wright J, Kahane S, Moeed A, Macdowell A. Accuracy of the surgeon's eye: use of the tip–apex distance in clinical practice. Injury. 2015;46:1346–8.CrossRef Wright J, Kahane S, Moeed A, Macdowell A. Accuracy of the surgeon's eye: use of the tip–apex distance in clinical practice. Injury. 2015;46:1346–8.CrossRef
19.
go back to reference Kuhl M, Beimel C. Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system. Injury. 2016;47:2155–60.CrossRef Kuhl M, Beimel C. Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system. Injury. 2016;47:2155–60.CrossRef
20.
go back to reference Li S, Chang SM, Jin YM, Zhang YQ, Niu WX, Du SC, Zhang LZ, Ma H. A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws. Injury. 2016;47:1302–8.CrossRef Li S, Chang SM, Jin YM, Zhang YQ, Niu WX, Du SC, Zhang LZ, Ma H. A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws. Injury. 2016;47:1302–8.CrossRef
21.
go back to reference Li J, Cheng L, Jing J. The Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients. Injury. 2015;101:143–6. Li J, Cheng L, Jing J. The Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients. Injury. 2015;101:143–6.
22.
go back to reference Morris S, Morris ME, Iansek R. Reliability of measurements obtained with the timed “up & go” test in people with Parkinson disease. Phys Ther. 2001;81(2):810–8.CrossRef Morris S, Morris ME, Iansek R. Reliability of measurements obtained with the timed “up & go” test in people with Parkinson disease. Phys Ther. 2001;81(2):810–8.CrossRef
23.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by Moore arthroplasty. J Bone Joint Surg Am. 1969;51(4):737–55.CrossRef Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by Moore arthroplasty. J Bone Joint Surg Am. 1969;51(4):737–55.CrossRef
24.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058–64.CrossRef Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058–64.CrossRef
25.
go back to reference Rubio-Avila J, Madden K, Simunovic N, Bhandari M. Tip to apex distance in femoral intertrochanteric fractures: a systematic review. J Orthop Sci. 2013;18:592–8.CrossRef Rubio-Avila J, Madden K, Simunovic N, Bhandari M. Tip to apex distance in femoral intertrochanteric fractures: a systematic review. J Orthop Sci. 2013;18:592–8.CrossRef
26.
go back to reference Li AB, Zhang WJ, Wang JQ, Zhao YM, Guo WJ. Learning curve and clinical outcomes of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures. Biomed Res Int. 2017;2017:6781070.PubMedPubMedCentral Li AB, Zhang WJ, Wang JQ, Zhao YM, Guo WJ. Learning curve and clinical outcomes of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures. Biomed Res Int. 2017;2017:6781070.PubMedPubMedCentral
27.
go back to reference Mark RBI, Ruurd LJ. Intramedullary hip screw Wxation of reverse oblique and transverse trochanteric femur fractures. Eur J Orthop Surg Traumatol. 2008;18:323–6.CrossRef Mark RBI, Ruurd LJ. Intramedullary hip screw Wxation of reverse oblique and transverse trochanteric femur fractures. Eur J Orthop Surg Traumatol. 2008;18:323–6.CrossRef
28.
go back to reference Duramaz A, İlter MH. The impact of proximal femoral nail type on clinical and radiological outcomes in the treatment of intertrochanteric femur fractures: a comparative study. Eur J Orthop Surg Traumatol. 2019;29:1441–9.CrossRef Duramaz A, İlter MH. The impact of proximal femoral nail type on clinical and radiological outcomes in the treatment of intertrochanteric femur fractures: a comparative study. Eur J Orthop Surg Traumatol. 2019;29:1441–9.CrossRef
29.
go back to reference Gavaskar AS, Tummala NC, Srinivasan P, Gopalan H, Karthik B, Santosh S. Helical blade or the integrated lag screws: a matched pair analysis of 100 patients with unstable trochanteric fractures. J Orthop Trauma. 2018;32:274–7.CrossRef Gavaskar AS, Tummala NC, Srinivasan P, Gopalan H, Karthik B, Santosh S. Helical blade or the integrated lag screws: a matched pair analysis of 100 patients with unstable trochanteric fractures. J Orthop Trauma. 2018;32:274–7.CrossRef
30.
go back to reference Mallya S, Kamath SU, Madegowda A, Krishnamurthy SL, Jain MK, Holla R. Comparison of radiological and functional outcome of unstable intertrochanteric femur fractures treated using PFN and PFNA-2 in patients with osteoporosis. Eur J Orthop Surg Traumatol. 2019;29:1035–42.CrossRef Mallya S, Kamath SU, Madegowda A, Krishnamurthy SL, Jain MK, Holla R. Comparison of radiological and functional outcome of unstable intertrochanteric femur fractures treated using PFN and PFNA-2 in patients with osteoporosis. Eur J Orthop Surg Traumatol. 2019;29:1035–42.CrossRef
31.
go back to reference Nikoloski AN, Osbrough AL, Yates PJ. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study. J Orthop Surg Res. 2013;8:35.CrossRef Nikoloski AN, Osbrough AL, Yates PJ. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study. J Orthop Surg Res. 2013;8:35.CrossRef
32.
go back to reference Boukebous B, Flouzat-Lachaniette CH, Donadio J, Chenguel Z, Guillon P, Rousseau MA. Femoral offset loss and internal arch restoration defect are correlated with intramedullary nail cut-out complications after pertrochanteric fractures: a case-control study. Eur J Orthop Surg Traumatol. 2019;29:1451–60.CrossRef Boukebous B, Flouzat-Lachaniette CH, Donadio J, Chenguel Z, Guillon P, Rousseau MA. Femoral offset loss and internal arch restoration defect are correlated with intramedullary nail cut-out complications after pertrochanteric fractures: a case-control study. Eur J Orthop Surg Traumatol. 2019;29:1451–60.CrossRef
33.
go back to reference Walton NP, Wynn-Jones H, Ward MS, Wimhurst JA. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference? Injury. 2005;36(11):1361–4.CrossRef Walton NP, Wynn-Jones H, Ward MS, Wimhurst JA. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference? Injury. 2005;36(11):1361–4.CrossRef
34.
go back to reference Bhashyam AR, Rodriguez EK, Appleton P, Wixted JJ. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study. J Orthop Trauma. 2018;32(7):e258–62.CrossRef Bhashyam AR, Rodriguez EK, Appleton P, Wixted JJ. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study. J Orthop Trauma. 2018;32(7):e258–62.CrossRef
35.
go back to reference Kay RM, Jaki KA, Skaggs DL. The effect of femoral rotation on the projected femoral neck-shaft angle. J Pediatr Orthop. 2000;20(6):736–9.CrossRef Kay RM, Jaki KA, Skaggs DL. The effect of femoral rotation on the projected femoral neck-shaft angle. J Pediatr Orthop. 2000;20(6):736–9.CrossRef
36.
go back to reference Aros B, Tosteson A, Gottlieb DJ, Koval KJ. Is a sliding hip screw or IM nail the preferred implant for intertrochanteric fracture fixation? Clin Orthop Relat Res. 2008;466:2827–32.CrossRef Aros B, Tosteson A, Gottlieb DJ, Koval KJ. Is a sliding hip screw or IM nail the preferred implant for intertrochanteric fracture fixation? Clin Orthop Relat Res. 2008;466:2827–32.CrossRef
37.
go back to reference Roberts JW, Libet LA, Wolinsky PR. Who is in danger? Impingement and penetration of the anterior cortex of the distal femur during intramedullary nailing of proximal femur fractures: preoperatively measurable risk factors. J Trauma Acute Care Surg. 2012;73(1):249–54.CrossRef Roberts JW, Libet LA, Wolinsky PR. Who is in danger? Impingement and penetration of the anterior cortex of the distal femur during intramedullary nailing of proximal femur fractures: preoperatively measurable risk factors. J Trauma Acute Care Surg. 2012;73(1):249–54.CrossRef
38.
go back to reference Peña OR, Gómez Gélvez A, Espinosa KA, Cardona JR. Cephalomedullary nails: factors associated with impingement of the anterior cortex of the femur in a Hispanic population. Arch Orthop Trauma Surg. 2015;135(11):1533–40.CrossRef Peña OR, Gómez Gélvez A, Espinosa KA, Cardona JR. Cephalomedullary nails: factors associated with impingement of the anterior cortex of the femur in a Hispanic population. Arch Orthop Trauma Surg. 2015;135(11):1533–40.CrossRef
39.
go back to reference Chang SM, Hu SJ, Ma Z, Du SC, Zhang YQ. Femoral intertrochanteric nail (fitn): a new short version design with an anterior curvature and a geometric match study using post-operative radiographs. Injury. 2018;49(2):328–33.CrossRef Chang SM, Hu SJ, Ma Z, Du SC, Zhang YQ. Femoral intertrochanteric nail (fitn): a new short version design with an anterior curvature and a geometric match study using post-operative radiographs. Injury. 2018;49(2):328–33.CrossRef
40.
go back to reference Zhang K, Zhang S, Yang J, Dong W, Wang S, Cheng Y, Alqwbani M, Wang Q, Yu B. Proximal femoral nail vs. dynamic hip screw in treatment of intertrochanteric fractures: a meta-analysis. Med Sci Monit. 2014;20:1628–33.CrossRef Zhang K, Zhang S, Yang J, Dong W, Wang S, Cheng Y, Alqwbani M, Wang Q, Yu B. Proximal femoral nail vs. dynamic hip screw in treatment of intertrochanteric fractures: a meta-analysis. Med Sci Monit. 2014;20:1628–33.CrossRef
Metadata
Title
How to get better TAD? Relationship between anteversion angle of nail and position of femoral neck guide pin during nailing of intertrochanteric fractures
Authors
Zhe Wang
Yadong Liu
Shenglong Li
Xiuhui Wang
Changjian Liu
Xin Tang
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2020
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-020-03518-5

Other articles of this Issue 1/2020

BMC Musculoskeletal Disorders 1/2020 Go to the issue