Background

There have been conflicting studies published regarding the ability of various total knee arthroplasty (TKA) techniques to correct preoperative deformity. The purpose of this study was to compare the postoperative radiographic alignment in patients with severe preoperative coronal deformity (≥10° varus/valgus) who underwent three different TKA techniques; manual instrumentation (MAN), computer navigated instrumentation (NAV) and patient specific instrumentation (PSI).

Methods

Patients, who received a TKA with a preoperative coronal deformity of ≥10° with available radiographs were included in this retrospective study. The groups were: MAN; n = 54, NAV; n = 52 and PSI; n = 53. The mechanical axis (varus / valgus) and the posterior tibial slope were measured and analysed using standing long leg- and lateral radiographs.

Results

The overall mean postoperative varus / valgus deformity was 2.8° (range, 0 to 9.9; SD 2.3) and 2.5° (range, 0 to 14.7; SD 2.3), respectively. The overall outliers (>3°) represented 30.2% (48 /159) of cases and were distributed as followed: MAN group: 31.5%, NAV group: 34.6%, PSI group: 24.4%. No significant statistical differences were found between these groups. The distribution of the severe outliers (>5°) was 14.8% in the MAN group, 23% in the NAV group and 5.6% in the PSI group. The PSI group had significantly (p = 0.0108) fewer severe outliers compared to the NAV group while all other pairs were not statistically significant.

Conclusions

In severe varus / valgus deformity the three surgical techniques demonstrated similar postoperative radiographic alignment. However, in reducing severe outliers (> 5°) and in achieving the planned posterior tibial slope the PSI technique for TKA may be superior to computer navigation and the conventional technique. Further prospective studies are needed to determine which technique is the best regarding reducing outliers in patients with severe preoperative coronal deformity.
Literature
1.
go back to reference Green GV, Berend KR, Berend ME, Glisson RR, Vail TP. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: The posteromedial hot spot. J Arthroplast. 2002;17:1033–9.CrossRef Green GV, Berend KR, Berend ME, Glisson RR, Vail TP. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: The posteromedial hot spot. J Arthroplast. 2002;17:1033–9.CrossRef
2.
go back to reference Liau JJ, Cheng CK, Huang CH, Lo WH. The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis. Clin Biomech (Bristol, Avon). 2002;17:140–6.CrossRef Liau JJ, Cheng CK, Huang CH, Lo WH. The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis. Clin Biomech (Bristol, Avon). 2002;17:140–6.CrossRef
3.
go back to reference Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech. 2005;38:349–55.CrossRefPubMed Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech. 2005;38:349–55.CrossRefPubMed
4.
go back to reference Choong PF, Stoney JD. Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast. 2009;24:560–9. Elsevier Inc.CrossRef Choong PF, Stoney JD. Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast. 2009;24:560–9. Elsevier Inc.CrossRef
5.
go back to reference Figgie HE, Goldberg VM, Figgie MP, Inglis AE, Kelly M, Sobel M. The effect of alignment of the implant on fractures of the patella after condylar total knee arthroplasty. J Bone Joint Surg Am. 1989;71:1031–9.CrossRefPubMed Figgie HE, Goldberg VM, Figgie MP, Inglis AE, Kelly M, Sobel M. The effect of alignment of the implant on fractures of the patella after condylar total knee arthroplasty. J Bone Joint Surg Am. 1989;71:1031–9.CrossRefPubMed
6.
go back to reference Huang NFR, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF. Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast. 2012;27:1737–41.CrossRef Huang NFR, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF. Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast. 2012;27:1737–41.CrossRef
7.
go back to reference Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;229:31–43. Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;229:31–43.
8.
go back to reference Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK. Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplast. 2012;27:1177–82.CrossRef Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK. Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplast. 2012;27:1177–82.CrossRef
9.
go back to reference Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast. 2007;22:1097–106.CrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast. 2007;22:1097–106.CrossRef
10.
go back to reference Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP. Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res. 2008;466:935–45.CrossRefPubMedPubMedCentral Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP. Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res. 2008;466:935–45.CrossRefPubMedPubMedCentral
11.
go back to reference Kim Y-H, Kim J-S, Choi Y, Kwon O-R. Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am. 2009;91:14–9.CrossRefPubMed Kim Y-H, Kim J-S, Choi Y, Kwon O-R. Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am. 2009;91:14–9.CrossRefPubMed
12.
go back to reference Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br. 2004;86:818–23.CrossRefPubMed Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br. 2004;86:818–23.CrossRefPubMed
13.
go back to reference Gøthesen O, Espehaug B, Havelin LI, Petursson G, Hallan G, Strøm E, et al. Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J. 2014;96-B:609–18.CrossRefPubMed Gøthesen O, Espehaug B, Havelin LI, Petursson G, Hallan G, Strøm E, et al. Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J. 2014;96-B:609–18.CrossRefPubMed
14.
go back to reference Jenny J-Y, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplast. 2005;20:832–9.CrossRef Jenny J-Y, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplast. 2005;20:832–9.CrossRef
15.
go back to reference Blakeney WG, Khan RJK, Wall SJ. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2011;93:1377–84.CrossRefPubMed Blakeney WG, Khan RJK, Wall SJ. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2011;93:1377–84.CrossRefPubMed
16.
go back to reference Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, et al. Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am. 2007;89:261–9.PubMed Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, et al. Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am. 2007;89:261–9.PubMed
17.
go back to reference Desai AS, Dramis A, Kendoff D, Board TN. Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome. Curr Rev Musculoskelet Med. 2010;4:11–5.CrossRef Desai AS, Dramis A, Kendoff D, Board TN. Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome. Curr Rev Musculoskelet Med. 2010;4:11–5.CrossRef
18.
go back to reference Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, et al. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc. 2014; Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, et al. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc. 2014;
19.
go back to reference Koch PP, Müller D, Pisan M, Fucentese SF. Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc. 2013;21:2200–5.CrossRefPubMed Koch PP, Müller D, Pisan M, Fucentese SF. Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc. 2013;21:2200–5.CrossRefPubMed
20.
go back to reference MacDessi SJ, Jang B, Harris IA, Wheatley E, Bryant C, Chen DB. A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty. Knee. 2014;21:406–9. Elsevier B.VCrossRefPubMed MacDessi SJ, Jang B, Harris IA, Wheatley E, Bryant C, Chen DB. A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty. Knee. 2014;21:406–9. Elsevier B.VCrossRefPubMed
21.
go back to reference Yan CH, Chiu KY, Ng FY, Chan PK, Fang CX. Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2014; Yan CH, Chiu KY, Ng FY, Chan PK, Fang CX. Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2014;
22.
go back to reference Mannan A, Smith TO, Sagar C, London NJ, Molitor PJA. No demonstrable benefit for coronal alignment outcomes in PSI knee arthroplasty: a systematic review and meta-analysis. Orthop Traumatol Surg Res. 2015;101:461–8.CrossRefPubMed Mannan A, Smith TO, Sagar C, London NJ, Molitor PJA. No demonstrable benefit for coronal alignment outcomes in PSI knee arthroplasty: a systematic review and meta-analysis. Orthop Traumatol Surg Res. 2015;101:461–8.CrossRefPubMed
23.
go back to reference Chen JY, Yeo SJ, Yew AKS, Tay DKJ, Chia S-L, Lo NN, et al. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014;22:630–5.CrossRefPubMed Chen JY, Yeo SJ, Yew AKS, Tay DKJ, Chia S-L, Lo NN, et al. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014;22:630–5.CrossRefPubMed
24.
go back to reference Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res. 2011;470:99–107.CrossRefPubMedCentral Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res. 2011;470:99–107.CrossRefPubMedCentral
26.
go back to reference Sorrells RB, Murphy JA, Sheridan KC, Wasielewski RC. The effect of varus and valgus deformity on results of cementless mobile bearing TKA. Knee. 2007;14:284–8.CrossRefPubMed Sorrells RB, Murphy JA, Sheridan KC, Wasielewski RC. The effect of varus and valgus deformity on results of cementless mobile bearing TKA. Knee. 2007;14:284–8.CrossRefPubMed
27.
go back to reference Faschingbauer M, Sgroi M, Juchems M, Reichel H, Kappe T. Can the tibial slope be measured on lateral knee radiographs? Knee Surg Sports Traumatol Arthrosc. 2014;22:3163–7.CrossRefPubMed Faschingbauer M, Sgroi M, Juchems M, Reichel H, Kappe T. Can the tibial slope be measured on lateral knee radiographs? Knee Surg Sports Traumatol Arthrosc. 2014;22:3163–7.CrossRefPubMed
28.
go back to reference Karachalios T, Sarangi PP, Newman JH. Severe varus and valgus deformities treated by total knee arthroplasty. J Bone Joint Surg Br. 1994;76:938–42.PubMed Karachalios T, Sarangi PP, Newman JH. Severe varus and valgus deformities treated by total knee arthroplasty. J Bone Joint Surg Br. 1994;76:938–42.PubMed
29.
go back to reference Chandler JT, Moskal JT. Evaluation of knee and hindfoot alignment before and after total knee arthroplasty: a prospective analysis. J Arthroplast. 2004;19:211–6.CrossRef Chandler JT, Moskal JT. Evaluation of knee and hindfoot alignment before and after total knee arthroplasty: a prospective analysis. J Arthroplast. 2004;19:211–6.CrossRef
30.
go back to reference Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, et al. Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc. 2013;22:621–9.CrossRefPubMed Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, et al. Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc. 2013;22:621–9.CrossRefPubMed
31.
go back to reference Carli A, Aoude A, Reuven A, Matache B, Antoniou J, Zukor D. Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment. Can J Surg. 2014;57:305–13.CrossRefPubMedPubMedCentral Carli A, Aoude A, Reuven A, Matache B, Antoniou J, Zukor D. Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment. Can J Surg. 2014;57:305–13.CrossRefPubMedPubMedCentral
32.
go back to reference Willcox NMJ, Clarke JV, Smith BRK, Deakin AH, Deep K. A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement. J Bone Joint Surg Br. 2012;94:1234–40.CrossRefPubMed Willcox NMJ, Clarke JV, Smith BRK, Deakin AH, Deep K. A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement. J Bone Joint Surg Br. 2012;94:1234–40.CrossRefPubMed
33.
go back to reference Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res. 1996:102–6. Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res. 1996:102–6.
34.
go back to reference Krackow KA, Pepe CL, Galloway EJ. A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopedics. 1990;13:861–8.PubMed Krackow KA, Pepe CL, Galloway EJ. A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopedics. 1990;13:861–8.PubMed
Metadata
Title
Postoperative alignment of TKA in patients with severe preoperative varus or valgus deformity: is there a difference between surgical techniques?
Authors
Stefan Rahm
Roland S. Camenzind
Andreas Hingsammer
Christopher Lenz
David E. Bauer
Mazda Farshad
Sandro F. Fucentese
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2017
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-017-1628-8

Other articles of this Issue 1/2017

BMC Musculoskeletal Disorders 1/2017 Go to the issue