Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 4/2008

01-04-2008 | Original Article

Computer Navigation Did Not Improve Alignment in a Lower-volume Total Knee Practice

Authors: W. P. Yau, MBBS, FRCSE, FHKCOS, K. Y. Chiu, FHKCOS, J. L. Zuo, MD, W. M. Tang, FHKCOS, T. P. Ng, FHKCOS

Published in: Clinical Orthopaedics and Related Research® | Issue 4/2008

Login to get access

Abstract

Postoperative alignment of the implanted prosthesis in computer-navigated TKA has been reported to be superior to that using the conventional technique. There is an assumption that use of computer navigation techniques can make an inexperienced or occasional TKA surgeon perform more like an expert TKA surgeon. To assess improved accuracy in recreation of mechanical alignment in TKA performed using computer navigation, a retrospective review of the experience of one of the authors (WPY) before and after using computer navigation was performed. We reviewed the radiographic results of 104 TKAs (52 computer navigation, 52 conventional technique) and found the accuracy of postoperative radiographic alignment of the implanted prosthesis was not improved by using computer navigation as judged by (1) overall limb alignment (case: varus 1.3°; control: varus 0.3°); (2) femoral component alignment (case: 90.3°; control: 90.3°); and (3) tibial component alignment (case: 89°; control: 90°). Significant factors that affected postoperative overall mechanical alignment in the current navigation series included severity of the preoperative deformity, amount of error in making bone cuts, and experience of the surgeon in using the computer navigation system.
Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty: a comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br. 2004;86:682–687.PubMedCrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty: a comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br. 2004;86:682–687.PubMedCrossRef
2.
go back to reference Bolognesi M, Hofmann A. Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res. 2005;440:162–169.PubMedCrossRef Bolognesi M, Hofmann A. Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res. 2005;440:162–169.PubMedCrossRef
3.
go back to reference Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK. A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop Relat Res. 1991;263:175–179.PubMed Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK. A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop Relat Res. 1991;263:175–179.PubMed
4.
go back to reference Callaghan JJ, Liu SS, Warth LC. Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty. 2006;21(4 suppl 1):27–28.PubMedCrossRef Callaghan JJ, Liu SS, Warth LC. Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty. 2006;21(4 suppl 1):27–28.PubMedCrossRef
5.
go back to reference Cates HE, Ritter MA, Keating EM, Faris PM. Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res. 1993;286:32–39.PubMed Cates HE, Ritter MA, Keating EM, Faris PM. Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res. 1993;286:32–39.PubMed
6.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomized, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomized, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef
7.
go back to reference Chin PL, Yang KY, Yeo SJ, Lo NN. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005;20:618–626.PubMedCrossRef Chin PL, Yang KY, Yeo SJ, Lo NN. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005;20:618–626.PubMedCrossRef
8.
go back to reference Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005;20:282–288.PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005;20:282–288.PubMedCrossRef
9.
go back to reference Dennis DA, Channer M, Susman MH, Stringer EA. Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. J Arthroplasty. 1993;8:43–47.PubMedCrossRef Dennis DA, Channer M, Susman MH, Stringer EA. Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. J Arthroplasty. 1993;8:43–47.PubMedCrossRef
10.
go back to reference Engh GA, Petersen TL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty. 1990;5:1–8.PubMedCrossRef Engh GA, Petersen TL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty. 1990;5:1–8.PubMedCrossRef
11.
go back to reference Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M. Early failures in total knee arthroplasty. Clin Orthop Relat Res. 2001;392:315–318.PubMedCrossRef Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M. Early failures in total knee arthroplasty. Clin Orthop Relat Res. 2001;392:315–318.PubMedCrossRef
12.
go back to reference Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res. 2005;433:152–159.PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res. 2005;433:152–159.PubMedCrossRef
13.
go back to reference Hart R, Janecek M, Chaker A, Bucek P. Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop. 2003;27:366–369.PubMedCrossRef Hart R, Janecek M, Chaker A, Bucek P. Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop. 2003;27:366–369.PubMedCrossRef
14.
go back to reference Hood RW, Vanni M, Insall JN. The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop Relat Res. 1981;160:94–105.PubMed Hood RW, Vanni M, Insall JN. The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop Relat Res. 1981;160:94–105.PubMed
15.
go back to reference Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res. 1985;192:13–22.PubMed Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res. 1985;192:13–22.PubMed
16.
go back to reference Ishii Y, Ohmori G, Bechtold JE, Gustilo RB. Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res. 1995;318:167–175.PubMed Ishii Y, Ohmori G, Bechtold JE, Gustilo RB. Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res. 1995;318:167–175.PubMed
17.
go back to reference Kim SJ, MacDonald M, Hernandez J, Wixson RL. Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty. 2005;20(7 suppl 3):123–131.PubMedCrossRef Kim SJ, MacDonald M, Hernandez J, Wixson RL. Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty. 2005;20(7 suppl 3):123–131.PubMedCrossRef
18.
go back to reference Kim YH, Kim JS, Yoon SH. Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br. 2007;89:471–476.PubMedCrossRef Kim YH, Kim JS, Yoon SH. Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br. 2007;89:471–476.PubMedCrossRef
19.
go back to reference Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A. Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty. 1998;13:552–558.PubMedCrossRef Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A. Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty. 1998;13:552–558.PubMedCrossRef
20.
go back to reference Malik MH, Wadia F, Porter ML. Preliminary radiological evaluation of the Vector Vision CT-free knee module for implantation of the LCS knee prosthesis. Knee. 2007;14:19–21.PubMedCrossRef Malik MH, Wadia F, Porter ML. Preliminary radiological evaluation of the Vector Vision CT-free knee module for implantation of the LCS knee prosthesis. Knee. 2007;14:19–21.PubMedCrossRef
21.
go back to reference Martin A, von Strempel A. Two-year outcomes of computed tomography-based and computed tomography free navigation total knee arthroplasties. Clin Orthop Relat Res. 2006;449:275–282.PubMed Martin A, von Strempel A. Two-year outcomes of computed tomography-based and computed tomography free navigation total knee arthroplasties. Clin Orthop Relat Res. 2006;449:275–282.PubMed
22.
go back to reference Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S. Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop. 2004;28:282–285.PubMedCrossRef Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S. Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop. 2004;28:282–285.PubMedCrossRef
23.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007;89:236–243.PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007;89:236–243.PubMedCrossRef
24.
go back to reference Patil S, D’Lima DD, Fait JM, Colwell CW Jr. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planning device. J Bone Joint Surg Am. 2007;89:381–387.PubMedCrossRef Patil S, D’Lima DD, Fait JM, Colwell CW Jr. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planning device. J Bone Joint Surg Am. 2007;89:381–387.PubMedCrossRef
25.
go back to reference Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J. Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc. 2005;13:167–173.PubMedCrossRef Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J. Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc. 2005;13:167–173.PubMedCrossRef
26.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res. 1994;299:153–156.PubMed Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res. 1994;299:153–156.PubMed
27.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.PubMedCrossRef
28.
go back to reference Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A. Positioning of total knee arthroplasty with and without navigation support: a prospective randomised study. J Bone Joint Surg Br. 2003;85:830–835.PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A. Positioning of total knee arthroplasty with and without navigation support: a prospective randomised study. J Bone Joint Surg Br. 2003;85:830–835.PubMed
29.
go back to reference Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180–186.PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180–186.PubMedCrossRef
30.
go back to reference Stulberg BN, Zadzilka JD. Computer-assisted surgery: a wine before its time: in opposition. J Arthroplasty. 2006;21(4 suppl 1):29–32.PubMedCrossRef Stulberg BN, Zadzilka JD. Computer-assisted surgery: a wine before its time: in opposition. J Arthroplasty. 2006;21(4 suppl 1):29–32.PubMedCrossRef
31.
go back to reference Teter KE, Bregman D, Colwell CW Jr. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop Relat Res. 1995;321:106–110.PubMed Teter KE, Bregman D, Colwell CW Jr. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop Relat Res. 1995;321:106–110.PubMed
32.
go back to reference Teter KE, Bregman D, Colwell CW Jr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res. 1995;321:117–121.PubMed Teter KE, Bregman D, Colwell CW Jr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res. 1995;321:117–121.PubMed
33.
go back to reference Tillett ED, Engh GA, Petersen T. A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res. 1988;230:176–181.PubMed Tillett ED, Engh GA, Petersen T. A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res. 1988;230:176–181.PubMed
34.
go back to reference Victor J, Hoste D. Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res. 2004;428:131–139.PubMedCrossRef Victor J, Hoste D. Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res. 2004;428:131–139.PubMedCrossRef
Metadata
Title
Computer Navigation Did Not Improve Alignment in a Lower-volume Total Knee Practice
Authors
W. P. Yau, MBBS, FRCSE, FHKCOS
K. Y. Chiu, FHKCOS
J. L. Zuo, MD
W. M. Tang, FHKCOS
T. P. Ng, FHKCOS
Publication date
01-04-2008
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 4/2008
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0144-4

Other articles of this Issue 4/2008

Clinical Orthopaedics and Related Research® 4/2008 Go to the issue

50 Years Ago in CORR

50 Years Ago in CORR