Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2015

Open Access 01-12-2015 | Research article

Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference

Authors: Bjoern Gunnar Ochs, Fabian Maria Stuby, Ulrich Stoeckle, Christoph Emanuel Gonser

Published in: BMC Musculoskeletal Disorders | Issue 1/2015

Login to get access

Abstract

Background

Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons.

Methods

The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde posterior column screws were virtually implanted using iPlan® CMF (BrainLAB AG, Feldkirchen, Germany); maximal implant length, maximal implant diameter and angles between the screw trajectories and the reference planes anterior pelvic plane as well as the midsagittal plane were assessed for gender-specific differences.

Results

The virtual analysis of the preformed bone stock column showed two constrictions of crucial clinical importance. These were located 49.6 ± 3.4 (41.0–60.2) mm (inferior margin of acetabulum) and 77.0 ± 5.6 (66.5–95.3) mm (centre of acetabulum) from the entry point of the implant in men and respectively 43.7 ± 2.3 (38.3–49.3) mm as well as 71.2 ± 3.5 (63.5–79.99) mm in women (men vs. women: p < 0.001). The entry point of the retrograde posterior column screw was located dorsal from the transition of the lower margin of the ischial tuberosity to ramus inferior pointing to the medial margin of the ischial tuberosity. In female patients, the entry point was located significantly closer to the medial margin of the ischial tuberosity. However, 7.3 mm screws can generally be used in men and women. The angle between the screw trajectory and the anterior pelvic plane in sagittal section was 14.0 ± 4.9 (2.5–28.6) °, the angle between the screw trajectory and the midsagittal plane in axial section was 31.1 ± 12.8 (1.5–77.9) ° and the angle between the screw trajectory and the midsagittal plane in coronal section was 8.4 ± 3.8 (1.5–20.0) °. For all angles, significant gender-specific differences were found (p < 0.001).

Conclusion

Therefore, the anterior pelvic plane as well as the midsagittal plane can facilitate intraoperative orientation for retrograde posterior column screw placement considering gender-specific differences in preformed bone corridor, implant length as well as angles formed between screw trajectory and these reference planes.
Literature
1.
go back to reference Jimenez ML, Vrahas MS. Surgical approaches to the acetabulum. Orthop Clin North Am. 1997;28(3):419–34.CrossRefPubMed Jimenez ML, Vrahas MS. Surgical approaches to the acetabulum. Orthop Clin North Am. 1997;28(3):419–34.CrossRefPubMed
2.
go back to reference Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, et al. Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury. 2010;41(12):1297–305.CrossRefPubMed Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, et al. Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury. 2010;41(12):1297–305.CrossRefPubMed
3.
go back to reference Dienstknecht T, Muller M, Sellei R, Nerlich M, Pfeifer C, Krutsch W, et al. Percutaneous screw placement in acetabular posterior column surgery: Gender differences in implant positioning. Injury. 2014;45(4):715–20.CrossRefPubMed Dienstknecht T, Muller M, Sellei R, Nerlich M, Pfeifer C, Krutsch W, et al. Percutaneous screw placement in acetabular posterior column surgery: Gender differences in implant positioning. Injury. 2014;45(4):715–20.CrossRefPubMed
4.
go back to reference Ochs BG, Stuby FM, Ateschrang A, Stoeckle U, Gonser CE. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane-Virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis. Injury. 2014;45(10):1590–8.CrossRefPubMed Ochs BG, Stuby FM, Ateschrang A, Stoeckle U, Gonser CE. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane-Virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis. Injury. 2014;45(10):1590–8.CrossRefPubMed
5.
go back to reference Attias N, Lindsey RW, Starr AJ, Borer D, Bridges K, Hipp JA. The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. J Bone Joint Surg. 2005;87(11):1520–3.CrossRef Attias N, Lindsey RW, Starr AJ, Borer D, Bridges K, Hipp JA. The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. J Bone Joint Surg. 2005;87(11):1520–3.CrossRef
6.
go back to reference Ebraheim NA, Xu R, Biyani A, Benedetti JA. Anatomic basis of lag screw placement in the anterior column of the acetabulum. Clin Orthop Relat Res. 1997;339:200–5.CrossRefPubMed Ebraheim NA, Xu R, Biyani A, Benedetti JA. Anatomic basis of lag screw placement in the anterior column of the acetabulum. Clin Orthop Relat Res. 1997;339:200–5.CrossRefPubMed
7.
go back to reference Mu WD, Wang XQ, Jia TH, Zhou DS, Cheng AX. Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum. Archives of orthopaedic and trauma surgery. Berlin/Heidelberg; 2009. Mu WD, Wang XQ, Jia TH, Zhou DS, Cheng AX. Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum. Archives of orthopaedic and trauma surgery. Berlin/Heidelberg; 2009.
8.
go back to reference Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV. Mapping the columns of the acetabulum--implications for percutaneous fixation. Injury. 2010;41(4):339–42.CrossRefPubMed Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV. Mapping the columns of the acetabulum--implications for percutaneous fixation. Injury. 2010;41(4):339–42.CrossRefPubMed
9.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217–20.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217–20.PubMed
10.
go back to reference Starr AJ, Jones AL, Reinert CM, Borer DS. Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury. 2001;32 Suppl 1:SA45–50.CrossRefPubMed Starr AJ, Jones AL, Reinert CM, Borer DS. Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury. 2001;32 Suppl 1:SA45–50.CrossRefPubMed
11.
go back to reference Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury. 2005;36(11):1330–6.CrossRefPubMed Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury. 2005;36(11):1330–6.CrossRefPubMed
12.
go back to reference Chen W, Zhang Z, Lu Y, Li J, Zhang Y, Shen Y. Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum. BMC Musculoskelet Disord. 2014;15:303.CrossRefPubMedPubMedCentral Chen W, Zhang Z, Lu Y, Li J, Zhang Y, Shen Y. Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum. BMC Musculoskelet Disord. 2014;15:303.CrossRefPubMedPubMedCentral
13.
go back to reference Puchwein P, Enninghorst N, Sisak K, Ortner T, Schildhauer TA, Balogh ZJ, et al. Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion. Arch Orthop Trauma Surg. 2012;132(6):805–11.CrossRefPubMed Puchwein P, Enninghorst N, Sisak K, Ortner T, Schildhauer TA, Balogh ZJ, et al. Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion. Arch Orthop Trauma Surg. 2012;132(6):805–11.CrossRefPubMed
14.
go back to reference Dienstknecht T, Muller M, Sellei R, Nerlich M, Muller FJ, Fuechtmeier B, et al. Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study. Int Orthop. 2013;37(4):673–9.CrossRefPubMed Dienstknecht T, Muller M, Sellei R, Nerlich M, Muller FJ, Fuechtmeier B, et al. Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study. Int Orthop. 2013;37(4):673–9.CrossRefPubMed
15.
go back to reference Banerjee SS, C; Starr, AJ; Banerjee, R. Pelvic CT-Based Graphical Modeling for Safe Insertion of Anterior and Posterior Column Screws In: Orthopaedic Trauma Association (OTA) Annual Meeting. San Antonio, Texas, USA: Orthopedic Trauma Association, 2011. Banerjee SS, C; Starr, AJ; Banerjee, R. Pelvic CT-Based Graphical Modeling for Safe Insertion of Anterior and Posterior Column Screws In: Orthopaedic Trauma Association (OTA) Annual Meeting. San Antonio, Texas, USA: Orthopedic Trauma Association, 2011.
16.
go back to reference Murtha PE, Hafez MA, Jaramaz B, DiGioia 3rd AM. Variations in acetabular anatomy with reference to total hip replacement. J Bone Joint Surg. 2008;90(3):308–13.CrossRef Murtha PE, Hafez MA, Jaramaz B, DiGioia 3rd AM. Variations in acetabular anatomy with reference to total hip replacement. J Bone Joint Surg. 2008;90(3):308–13.CrossRef
17.
go back to reference Maruyama M, Feinberg JR, Capello WN, D’Antonio JA. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop Relat Res. 2001;393:52–65.CrossRefPubMed Maruyama M, Feinberg JR, Capello WN, D’Antonio JA. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop Relat Res. 2001;393:52–65.CrossRefPubMed
18.
go back to reference Murray DW. The definition and measurement of acetabular orientation. J BoneJoint Surg. 1993;75(2):228–32. Murray DW. The definition and measurement of acetabular orientation. J BoneJoint Surg. 1993;75(2):228–32.
19.
go back to reference Jaramaz B, DiGioia 3rd AM, Blackwell M, Nikou C. Computer assisted measurement of cup placement in total hip replacement. Clinical orthopaedics and related research. 1998;354:70–81.CrossRefPubMed Jaramaz B, DiGioia 3rd AM, Blackwell M, Nikou C. Computer assisted measurement of cup placement in total hip replacement. Clinical orthopaedics and related research. 1998;354:70–81.CrossRefPubMed
20.
go back to reference Amiot LP, Poulin F. Computed tomography-based navigation for hip, knee, and spine surgery. Clin Orthop Relat Res. 2004;421:77–86.CrossRefPubMed Amiot LP, Poulin F. Computed tomography-based navigation for hip, knee, and spine surgery. Clin Orthop Relat Res. 2004;421:77–86.CrossRefPubMed
21.
go back to reference Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A. Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J. 2005;25:1–9.PubMedPubMedCentral Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A. Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J. 2005;25:1–9.PubMedPubMedCentral
22.
go back to reference Pullen WM, Henebry A, Gaskill T. Variability of acetabular coverage between supine and weightbearing pelvic radiographs. Am J Sports Med. 2014;42(11):2643–8.CrossRefPubMed Pullen WM, Henebry A, Gaskill T. Variability of acetabular coverage between supine and weightbearing pelvic radiographs. Am J Sports Med. 2014;42(11):2643–8.CrossRefPubMed
Metadata
Title
Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
Authors
Bjoern Gunnar Ochs
Fabian Maria Stuby
Ulrich Stoeckle
Christoph Emanuel Gonser
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2015
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-015-0697-9

Other articles of this Issue 1/2015

BMC Musculoskeletal Disorders 1/2015 Go to the issue