Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 6/2012

01-06-2012 | Trauma Surgery

Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion

Authors: Paul Puchwein, Natalie Enninghorst, Krisztian Sisak, Thomas Ortner, Thomas Armin Schildhauer, Zsolt J. Balogh, Wolfgang Pichler

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 6/2012

Login to get access

Abstract

Introduction

Percutaneous retrograde screw fixation for acetabular fractures is a demanding procedure due to the complex anatomy of the pelvis and the varying narrow safe bony corridors. Limited information is available on optimal screw placement and the geometry of safe zones for screw insertion in the pelvis.

Methods

Three-dimensional reconstructions of 50 consecutive CT scans of polytrauma patients (35 males, 15 females) were used to introduce three virtual CAD bolts (representing screws) into the anterior column (superior ramus of the pubic bone), posterior column (the ischial bone) and the supraacetabular region, as performed during percutaneous screw fixation. The three-dimensional (3D) position of these screws was evaluated with a computer software (MIMICS) after virtual optimal insertion. The 3D position, the narrowest zone and the distance to the hip joint of the two columns and the supraacetabular region were defined.

Results

The mean maximal screw length for the three virtual screws measured between 107.4 and 148 ± 18.7 mm. The narrowest zone of the pelvic bone (superior pubic ramus) had a width of 9.2 ± 2.4 mm. The average distances between the bolts and the hip joint were 3.9 and 19.4 ± 7.4 mm. For the anterior column (superior pubic ramus) screw, the mean lateral angle to the sagittal midline plane was 39.0 ± 3.2° and the mean posterior angle to the transversal midline plane was 15.1 ± 4.0°. The mean supraacetabular screw angles measured 22.4 ± 3.4° (medial), 35.3 ± 4.6° (cranial) and the mean angles for the ischial screw were 12.0 ± 5.4° (posterior) and 18.4 ± 4.0° (lateral).

Conclusions

The zones for safe screw positioning are very narrow, making percutaneous screw fixation of the acetabulum a challenging procedure. The predefined angles for the most frequently positioned percutaneous screws may aid in preoperative planning, decrease operative and radiation times and help to increase safe insertion of screws.
Literature
1.
go back to reference Carroll EA, Huber FG, Goldman AT, Virkus WW, Pagenkopf E, Lorich DG, Helfet DL (2010) Treatment of acetabular fractures in an older population. J Orthop Trauma 24(10):637–644PubMedCrossRef Carroll EA, Huber FG, Goldman AT, Virkus WW, Pagenkopf E, Lorich DG, Helfet DL (2010) Treatment of acetabular fractures in an older population. J Orthop Trauma 24(10):637–644PubMedCrossRef
2.
go back to reference Ferguson TA, Patel R, Bhandari M, Matta JM (2010) Fractures of the acetabulum in patients aged 60 years and older: an epidemiological and radiological study. J Bone Joint Surg Br 92(2):250–257PubMedCrossRef Ferguson TA, Patel R, Bhandari M, Matta JM (2010) Fractures of the acetabulum in patients aged 60 years and older: an epidemiological and radiological study. J Bone Joint Surg Br 92(2):250–257PubMedCrossRef
3.
go back to reference Mears DC (1999) Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone. J Am Acad Orthop Surg 7(2):128–141 ReviewPubMed Mears DC (1999) Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone. J Am Acad Orthop Surg 7(2):128–141 ReviewPubMed
4.
go back to reference Vallier HA, Cureton BA, Ekstein C, Oldenburg FP, Wilber JH (2010) Early definitive stabilization of unstable pelvis and acetabulum fractures reduces morbidity. J Trauma 69(3):677–684PubMedCrossRef Vallier HA, Cureton BA, Ekstein C, Oldenburg FP, Wilber JH (2010) Early definitive stabilization of unstable pelvis and acetabulum fractures reduces morbidity. J Trauma 69(3):677–684PubMedCrossRef
5.
go back to reference Bates P, Gary J, Singh G, Reinert C, Starr A (2011) Percutaneous treatment of pelvic and acetabular fractures in obese patients. Orthop Clin North Am 42(1):55–67PubMedCrossRef Bates P, Gary J, Singh G, Reinert C, Starr A (2011) Percutaneous treatment of pelvic and acetabular fractures in obese patients. Orthop Clin North Am 42(1):55–67PubMedCrossRef
6.
go back to reference Starr AJ, Jones AL, Reinert CM, Borer DS (2001) Preliminary results andcomplications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury 32(Suppl 1):SA45–SA50PubMed Starr AJ, Jones AL, Reinert CM, Borer DS (2001) Preliminary results andcomplications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury 32(Suppl 1):SA45–SA50PubMed
7.
go back to reference Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12(1):51–58PubMedCrossRef Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12(1):51–58PubMedCrossRef
8.
go back to reference Kaempffe FA, Bone LB, Border JR (1991) Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma 5(4):439–445PubMedCrossRef Kaempffe FA, Bone LB, Border JR (1991) Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma 5(4):439–445PubMedCrossRef
9.
go back to reference Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV (2010) Mapping the columns of the acetabulum—implications for percutaneous fixation. Injury. 41(4):339–342PubMedCrossRef Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV (2010) Mapping the columns of the acetabulum—implications for percutaneous fixation. Injury. 41(4):339–342PubMedCrossRef
10.
go back to reference Attias N, Lindsey RW, Starr AJ, Borer D, Bridges K, Hipp JA (2005) The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. J Bone Joint Surg Br 87(11):1520–1523PubMedCrossRef Attias N, Lindsey RW, Starr AJ, Borer D, Bridges K, Hipp JA (2005) The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. J Bone Joint Surg Br 87(11):1520–1523PubMedCrossRef
11.
go back to reference Zhang YZ, Lu S, Chen B, Zhao JM, Liu R, Pei GX (2011) Application of computer-aided design osteotomy template for treatment of cubitus varus deformity in teenagers: a pilot study. J Shoulder Elbow Surg 20(1):51–56PubMedCrossRef Zhang YZ, Lu S, Chen B, Zhao JM, Liu R, Pei GX (2011) Application of computer-aided design osteotomy template for treatment of cubitus varus deformity in teenagers: a pilot study. J Shoulder Elbow Surg 20(1):51–56PubMedCrossRef
12.
go back to reference Pichler W, Windisch G, Schaffler G, Heidari N, Dorr K, Grechenig W (2010) Computer-assisted 3-dimensional anthropometry of the scaphoid. Orthopedics 33(2):85–88PubMedCrossRef Pichler W, Windisch G, Schaffler G, Heidari N, Dorr K, Grechenig W (2010) Computer-assisted 3-dimensional anthropometry of the scaphoid. Orthopedics 33(2):85–88PubMedCrossRef
13.
go back to reference Pichler W, Windisch G, Schaffler G, Rienmüller R, Grechenig WJ (2009) Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. Hand Surg Eur 34(5):598–602CrossRef Pichler W, Windisch G, Schaffler G, Rienmüller R, Grechenig WJ (2009) Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. Hand Surg Eur 34(5):598–602CrossRef
14.
go back to reference Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, Moretti B, Leyvraz PF (2005) Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 36(11):1330–1336PubMedCrossRef Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, Moretti B, Leyvraz PF (2005) Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 36(11):1330–1336PubMedCrossRef
15.
go back to reference Gay SB, Sistrom C, Wang GJ, Kahler DA, Boman T, McHugh N, Goitz HT (1992) Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique. AJR Am J Roentgenol 158(4):819–822PubMed Gay SB, Sistrom C, Wang GJ, Kahler DA, Boman T, McHugh N, Goitz HT (1992) Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique. AJR Am J Roentgenol 158(4):819–822PubMed
16.
go back to reference Routt ML Jr, Simonian PT, Grujic L (1995) The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma 9(1):35–44PubMedCrossRef Routt ML Jr, Simonian PT, Grujic L (1995) The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma 9(1):35–44PubMedCrossRef
17.
go back to reference Routt ML, Nork SE, Mills WJ (2000) Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res 375:15–29PubMedCrossRef Routt ML, Nork SE, Mills WJ (2000) Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res 375:15–29PubMedCrossRef
18.
go back to reference Parker PJ, Copeland C (1997) Percutaneous fluoroscopic screw fixation of acetabularfractures. Injury 28(910):597–600PubMedCrossRef Parker PJ, Copeland C (1997) Percutaneous fluoroscopic screw fixation of acetabularfractures. Injury 28(910):597–600PubMedCrossRef
19.
go back to reference Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, Stuby FM (2010) Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury 41(12) Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, Stuby FM (2010) Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury 41(12)
20.
go back to reference Vioreanu MH, Mulhall KJ (2011) Intra-operative imaging technique to aid safe placement of screws in percutaneous fixation of pelvic and acetabular fractures. Acta Orthop Belg 77(3):398–401PubMed Vioreanu MH, Mulhall KJ (2011) Intra-operative imaging technique to aid safe placement of screws in percutaneous fixation of pelvic and acetabular fractures. Acta Orthop Belg 77(3):398–401PubMed
Metadata
Title
Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion
Authors
Paul Puchwein
Natalie Enninghorst
Krisztian Sisak
Thomas Ortner
Thomas Armin Schildhauer
Zsolt J. Balogh
Wolfgang Pichler
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 6/2012
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-012-1486-7

Other articles of this Issue 6/2012

Archives of Orthopaedic and Trauma Surgery 6/2012 Go to the issue