Skip to main content
Top
Published in: BMC Nephrology 1/2022

Open Access 01-12-2022 | Ultrasound | Research

Automated lung ultrasound image assessment using artificial intelligence to identify fluid overload in dialysis patients

Authors: Grace Feng Ling Tan, Tiehua Du, Justin Shuang Liu, Chung Cheen Chai, Chan Maung Nyein, Allen Yan Lun Liu

Published in: BMC Nephrology | Issue 1/2022

Login to get access

Abstract

Background

Fluid assessment is challenging, and fluid overload poses a significant problem among dialysis patients, with pulmonary oedema being the most serious consequence. Our study aims to develop a simple objective fluid assessment strategy using lung ultrasound (LUS) and artificial intelligence (AI) to assess the fluid status of dialysis patients.

Methods

This was a single-centre study of 76 hemodialysis and peritoneal dialysis patients carried out between July 2020 to May 2022. The fluid status of dialysis patients was assessed via a simplified 8-point LUS method using a portable handheld ultrasound device (HHUSD), clinical examination and bioimpedance analysis (BIA).
The primary outcome was the performance of 8-point LUS using a portable HHUSD in diagnosing fluid overload compared to physical examination and BIA. The secondary outcome was to develop and validate a novel AI software program to quantify B-line count and assess the fluid status of dialysis patients.

Results

Our study showed a moderate correlation between LUS B-line count and fluid overload assessed by clinical examination (r = 0.475, p < 0.001) and BIA (r = 0.356. p < 0.001). The use of AI to detect B-lines on LUS in our study for dialysis patients was shown to have good agreement with LUS B lines observed by physicians; (r = 0.825, p < 0.001) for the training dataset and (r = 0.844, p < 0.001) for the validation dataset.

Conclusion

Our study confirms that 8-point LUS using HHUSD, with AI-based detection of B lines, can provide clinically useful information on the assessment of hydration status and diagnosis of fluid overload for dialysis patients in a user-friendly and time-efficient way.
Literature
1.
go back to reference Zoccali C, Torino C, Tripepi R, Tripepi G, D’Arrigo G, et al. Pulmonary congestion predicts cardiac events and mortality in ESRD. JASN. 2013;24(4):639–46.CrossRef Zoccali C, Torino C, Tripepi R, Tripepi G, D’Arrigo G, et al. Pulmonary congestion predicts cardiac events and mortality in ESRD. JASN. 2013;24(4):639–46.CrossRef
2.
go back to reference Giannese D, Puntoni A, Cupisti A, Morganti R, Varricchio E, D’Alessandro C, et al. Lung ultrasound and BNP to detect hidden pulmonary congestion in euvolemic hemodialysis patients: a single Centre experience. BMC Nephrol. 2021;22(1):36.CrossRef Giannese D, Puntoni A, Cupisti A, Morganti R, Varricchio E, D’Alessandro C, et al. Lung ultrasound and BNP to detect hidden pulmonary congestion in euvolemic hemodialysis patients: a single Centre experience. BMC Nephrol. 2021;22(1):36.CrossRef
3.
go back to reference Adamska-Wełnicka A, Wełnicki M, Krzesiński P, Niemczyk S, Lubas A. Multi-method complex approach for hydration assessment does not detect a hydration difference in hemodialysis versus peritoneal Dialysis patient. Diagnostics (Basel). 2020;10(10). Adamska-Wełnicka A, Wełnicki M, Krzesiński P, Niemczyk S, Lubas A. Multi-method complex approach for hydration assessment does not detect a hydration difference in hemodialysis versus peritoneal Dialysis patient. Diagnostics (Basel). 2020;10(10).
4.
go back to reference Koratala A, Ronco C, Kazory A. The promising role of lung ultrasound in assessment of volume status for patients receiving maintenance renal replacement therapy. Blood Purif. 2020;49(6):643–6.CrossRef Koratala A, Ronco C, Kazory A. The promising role of lung ultrasound in assessment of volume status for patients receiving maintenance renal replacement therapy. Blood Purif. 2020;49(6):643–6.CrossRef
5.
go back to reference Zoccali C, Torino C, Tripepi R, Tripepi G, D'Arrigo G, Postorino M, et al. Pulmonary congestion predicts cardiac events and mortality in ESRD. J Am Soc Nephrol. 2013;24(4):639–46.CrossRef Zoccali C, Torino C, Tripepi R, Tripepi G, D'Arrigo G, Postorino M, et al. Pulmonary congestion predicts cardiac events and mortality in ESRD. J Am Soc Nephrol. 2013;24(4):639–46.CrossRef
6.
go back to reference Beaubien-Souligny W, Rhéaume M, Blondin MC, El-Barnachawy S, Fortier A, Éthier J, et al. A simplified approach to extravascular lung water assessment using point-of-care ultrasound in patients with end-stage chronic renal failure undergoing hemodialysis. Blood Purif. 2018;45(1–3):79–87.CrossRef Beaubien-Souligny W, Rhéaume M, Blondin MC, El-Barnachawy S, Fortier A, Éthier J, et al. A simplified approach to extravascular lung water assessment using point-of-care ultrasound in patients with end-stage chronic renal failure undergoing hemodialysis. Blood Purif. 2018;45(1–3):79–87.CrossRef
7.
go back to reference Jambrik Z, Monti S, Coppola V, Agricola E, Mottola G, Miniati M, et al. Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water. Am J Cardiol. 2004;93(10):1265–70.CrossRef Jambrik Z, Monti S, Coppola V, Agricola E, Mottola G, Miniati M, et al. Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water. Am J Cardiol. 2004;93(10):1265–70.CrossRef
8.
go back to reference Reisinger N, Lohani S, Hagemeier J, Panebianco N, Baston C. Lung ultrasound to diagnose pulmonary congestion among patients on hemodialysis: comparison of full versus abbreviated scanning protocols. Am J Kidney Dis. 2022 Feb;79(2):193–201.e1.CrossRef Reisinger N, Lohani S, Hagemeier J, Panebianco N, Baston C. Lung ultrasound to diagnose pulmonary congestion among patients on hemodialysis: comparison of full versus abbreviated scanning protocols. Am J Kidney Dis. 2022 Feb;79(2):193–201.e1.CrossRef
9.
go back to reference Torino C, Tripepi R, Loutradis C, Sarafidis P, Tripepi G, Mallamaci F, et al. Can the assessment of ultrasound lung water in haemodialysis patients be simplified? Nephrol Dial Transplant. 2020;22:36. Torino C, Tripepi R, Loutradis C, Sarafidis P, Tripepi G, Mallamaci F, et al. Can the assessment of ultrasound lung water in haemodialysis patients be simplified? Nephrol Dial Transplant. 2020;22:36.
10.
go back to reference Platz E, Pivetta E, Merz AA, Peck J, Rivero J, Cheng S. Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure. Am J Emerg Med. 2015;33(11):1552–6.CrossRef Platz E, Pivetta E, Merz AA, Peck J, Rivero J, Cheng S. Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure. Am J Emerg Med. 2015;33(11):1552–6.CrossRef
11.
go back to reference Moore CL, Wang J, Battisti AJ, Chen A, Fincke J, Wang A, et al. Interobserver agreement and correlation of an automated algorithm for B-line identification and quantification with expert Sonologist review in a handheld ultrasound device. J Ultrasound Med. 2022;41(10):2487–95.CrossRef Moore CL, Wang J, Battisti AJ, Chen A, Fincke J, Wang A, et al. Interobserver agreement and correlation of an automated algorithm for B-line identification and quantification with expert Sonologist review in a handheld ultrasound device. J Ultrasound Med. 2022;41(10):2487–95.CrossRef
12.
go back to reference Short J, Acebes C, Rodriguez-de-Lema G, La Paglia GMC, Pavón M, Sánchez-Pernaute O, et al. Visual versus automatic ultrasound scoring of lung B-lines: reliability and consistency between systems. Med Ultrason. 2019;21(1):45–9.CrossRef Short J, Acebes C, Rodriguez-de-Lema G, La Paglia GMC, Pavón M, Sánchez-Pernaute O, et al. Visual versus automatic ultrasound scoring of lung B-lines: reliability and consistency between systems. Med Ultrason. 2019;21(1):45–9.CrossRef
13.
go back to reference Basso F, Milan Manani S, Cruz DN, Teixeira C, Brendolan A, Nalesso F, et al. Comparison and reproducibility of techniques for fluid status assessment in chronic hemodialysis patients. Cardiorenal Med. 2013;3(2):104–12.CrossRef Basso F, Milan Manani S, Cruz DN, Teixeira C, Brendolan A, Nalesso F, et al. Comparison and reproducibility of techniques for fluid status assessment in chronic hemodialysis patients. Cardiorenal Med. 2013;3(2):104–12.CrossRef
14.
go back to reference Brusasco C, Santori G, Bruzzo E, Trò R, Robba C, Tavazzi G, et al. Quantitative lung ultrasonography: a putative new algorithm for automatic detection and quantification of B-lines. Crit Care. 2019;23(1):288.CrossRef Brusasco C, Santori G, Bruzzo E, Trò R, Robba C, Tavazzi G, et al. Quantitative lung ultrasonography: a putative new algorithm for automatic detection and quantification of B-lines. Crit Care. 2019;23(1):288.CrossRef
15.
go back to reference Russell FM, Ehrman RR, Barton A, Sarmiento E, Ottenhoff JE, Nti BK. B-line quantification: comparing learners novice to lung ultrasound assisted by machine artificial intelligence technology to expert review. Ultrasound J. 2021;13(1):33.CrossRef Russell FM, Ehrman RR, Barton A, Sarmiento E, Ottenhoff JE, Nti BK. B-line quantification: comparing learners novice to lung ultrasound assisted by machine artificial intelligence technology to expert review. Ultrasound J. 2021;13(1):33.CrossRef
16.
go back to reference Volpicelli G, Mussa A, Garofalo G, Cardinale L, Casoli G, Perotto F, et al. Bedside lung ultrasound in the assessment of alveolar-interstitial syndrome. Am J Emerg Med. 2006;24(6):689–96.CrossRef Volpicelli G, Mussa A, Garofalo G, Cardinale L, Casoli G, Perotto F, et al. Bedside lung ultrasound in the assessment of alveolar-interstitial syndrome. Am J Emerg Med. 2006;24(6):689–96.CrossRef
17.
go back to reference Picano E, Frassi F, Agricola E, Gligorova S, Gargani L, Mottola G. Ultrasound lung comets: a clinically useful sign of extravascular lung water. J Am Soc Echocardiogr. 2006;19(3):356–63.CrossRef Picano E, Frassi F, Agricola E, Gligorova S, Gargani L, Mottola G. Ultrasound lung comets: a clinically useful sign of extravascular lung water. J Am Soc Echocardiogr. 2006;19(3):356–63.CrossRef
18.
go back to reference Bolya D, Zhou C, Xiao F, Lee YJ, Yolact: real-time instance segmentation. Proceedings of the IEEE/CVF international conference on computer vision; 2019. Bolya D, Zhou C, Xiao F, Lee YJ, Yolact: real-time instance segmentation. Proceedings of the IEEE/CVF international conference on computer vision; 2019.
19.
go back to reference He K, Gkioxari G, Dollar P, Girshick R. Mask R-CNN. IEEE Trans Pattern Anal Mach Intell. 2020;42(2):386–97.CrossRef He K, Gkioxari G, Dollar P, Girshick R. Mask R-CNN. IEEE Trans Pattern Anal Mach Intell. 2020;42(2):386–97.CrossRef
20.
go back to reference Kim EJ, Choi MJ, Lee JH, Oh JE, Seo JW, Lee YK, et al. Extracellular fluid/intracellular fluid volume ratio as a novel risk Indicator for all-cause mortality and cardiovascular disease in hemodialysis patients. PLoS One. 2017;12(1):e0170272.CrossRef Kim EJ, Choi MJ, Lee JH, Oh JE, Seo JW, Lee YK, et al. Extracellular fluid/intracellular fluid volume ratio as a novel risk Indicator for all-cause mortality and cardiovascular disease in hemodialysis patients. PLoS One. 2017;12(1):e0170272.CrossRef
21.
go back to reference Cha K, Chertow GM, Gonzalez J, Lazarus JM, Wilmore DW. Multifrequency bioelectrical impedance estimates the distribution of body water. J Appl Physiol. 1995;79(4):1316–9.CrossRef Cha K, Chertow GM, Gonzalez J, Lazarus JM, Wilmore DW. Multifrequency bioelectrical impedance estimates the distribution of body water. J Appl Physiol. 1995;79(4):1316–9.CrossRef
22.
go back to reference Mallamaci F, Benedetto FA, Tripepi R, Rastelli S, Castellino P, Tripepi G, et al. Detection of pulmonary congestion by chest ultrasound in dialysis patients. JACC Cardiovasc Imaging. 2010;3(6):586–94.CrossRef Mallamaci F, Benedetto FA, Tripepi R, Rastelli S, Castellino P, Tripepi G, et al. Detection of pulmonary congestion by chest ultrasound in dialysis patients. JACC Cardiovasc Imaging. 2010;3(6):586–94.CrossRef
23.
go back to reference Enia G, Torino C, Panuccio V, Tripepi R, Postorino M, Aliotta R, et al. Asymptomatic pulmonary congestion and physical functioning in hemodialysis patients. Clin J Am Soc Nephrol. 2013;8(8):1343–8.CrossRef Enia G, Torino C, Panuccio V, Tripepi R, Postorino M, Aliotta R, et al. Asymptomatic pulmonary congestion and physical functioning in hemodialysis patients. Clin J Am Soc Nephrol. 2013;8(8):1343–8.CrossRef
24.
go back to reference Zoccali C, Torino C, Mallamaci F, Sarafidis P, Papagianni A, Ekart R, et al. A randomised multicenter trial on a lung ultrasound-guided treatment strategy in patients on chronic hemodialysis with high cardiovascular risk. Kidney Int. 2021;100:1325–33. Zoccali C, Torino C, Mallamaci F, Sarafidis P, Papagianni A, Ekart R, et al. A randomised multicenter trial on a lung ultrasound-guided treatment strategy in patients on chronic hemodialysis with high cardiovascular risk. Kidney Int. 2021;100:1325–33.
25.
go back to reference Miao J, Sy-Go JPT, Issa M, Jenad H, Manohar S, Zoghby Z, et al. Ultrasonographic assessment of extravascular lung water in hospitalised patients requiring hemodialysis: a prospective observational study. Cardiorenal Med. 2021;11(3):151–60.CrossRef Miao J, Sy-Go JPT, Issa M, Jenad H, Manohar S, Zoghby Z, et al. Ultrasonographic assessment of extravascular lung water in hospitalised patients requiring hemodialysis: a prospective observational study. Cardiorenal Med. 2021;11(3):151–60.CrossRef
26.
go back to reference Torino C, Gargani L, Sicari R, Letachowicz K, Ekart R, Fliser D, et al. The agreement between auscultation and lung ultrasound in hemodialysis patients: the LUST study. Clin J Am Soc Nephrol. 2016;11(11):2005–11.CrossRef Torino C, Gargani L, Sicari R, Letachowicz K, Ekart R, Fliser D, et al. The agreement between auscultation and lung ultrasound in hemodialysis patients: the LUST study. Clin J Am Soc Nephrol. 2016;11(11):2005–11.CrossRef
27.
go back to reference Marino F, Martorano C, Tripepi R, Bellantoni M, Tripepi G, Mallamaci F, et al. Subclinical pulmonary congestion is prevalent in nephrotic syndrome. Kidney Int. 2016;89(2):421–8.CrossRef Marino F, Martorano C, Tripepi R, Bellantoni M, Tripepi G, Mallamaci F, et al. Subclinical pulmonary congestion is prevalent in nephrotic syndrome. Kidney Int. 2016;89(2):421–8.CrossRef
28.
go back to reference Panuccio V, Enia G, Tripepi R, Torino C, Garozzo M, Battaglia GG, et al. Chest ultrasound and hidden lung congestion in peritoneal dialysis patients. Nephrology Dialysis Transplantation. 2012;27(9):3601–5.CrossRef Panuccio V, Enia G, Tripepi R, Torino C, Garozzo M, Battaglia GG, et al. Chest ultrasound and hidden lung congestion in peritoneal dialysis patients. Nephrology Dialysis Transplantation. 2012;27(9):3601–5.CrossRef
29.
go back to reference Siriopol D, Hogas S, Voroneanu L, Onofriescu M, Apetrii M, Oleniuc M, et al. Predicting mortality in haemodialysis patients: a comparison between lung ultrasonography, bioimpedance data and echocardiography parameters. Nephrol Dial Transplant. 2013;28(11):2851–9.CrossRef Siriopol D, Hogas S, Voroneanu L, Onofriescu M, Apetrii M, Oleniuc M, et al. Predicting mortality in haemodialysis patients: a comparison between lung ultrasonography, bioimpedance data and echocardiography parameters. Nephrol Dial Transplant. 2013;28(11):2851–9.CrossRef
30.
go back to reference Saad MM, Kamal J, Moussaly E, Karam B, Mansour W, Gobran E, et al. Relevance of B-lines on lung ultrasound in volume overload and pulmonary congestion: clinical correlations and outcomes in patients on hemodialysis. Cardiorenal Med. 2018;8(2):83–91.CrossRef Saad MM, Kamal J, Moussaly E, Karam B, Mansour W, Gobran E, et al. Relevance of B-lines on lung ultrasound in volume overload and pulmonary congestion: clinical correlations and outcomes in patients on hemodialysis. Cardiorenal Med. 2018;8(2):83–91.CrossRef
31.
go back to reference Wallin CJ, Jacobson SH, Leksell LG. Subclinical pulmonary oedema and intermittent haemodialysis. Nephrol Dial Transplant. 1996;11(11):2269–75.CrossRef Wallin CJ, Jacobson SH, Leksell LG. Subclinical pulmonary oedema and intermittent haemodialysis. Nephrol Dial Transplant. 1996;11(11):2269–75.CrossRef
32.
go back to reference Vitturi N, Dugo M, Soattin M, Simoni F, Maresca L, Zagatti R, et al. Lung ultrasound during hemodialysis: the role in the assessment of volume status. Int Urol Nephrol. 2014;46(1):169–74.CrossRef Vitturi N, Dugo M, Soattin M, Simoni F, Maresca L, Zagatti R, et al. Lung ultrasound during hemodialysis: the role in the assessment of volume status. Int Urol Nephrol. 2014;46(1):169–74.CrossRef
33.
go back to reference Paudel K, Kausik T, Visser A, Ramballi C, Fan SL. Comparing lung ultrasound with bioimpedance spectroscopy for evaluating hydration in peritoneal dialysis patients. Nephrology (Carlton). 2015;20(1):1–5.CrossRef Paudel K, Kausik T, Visser A, Ramballi C, Fan SL. Comparing lung ultrasound with bioimpedance spectroscopy for evaluating hydration in peritoneal dialysis patients. Nephrology (Carlton). 2015;20(1):1–5.CrossRef
34.
go back to reference van Sloun RJG, Demi L. Localizing B-lines in lung ultrasonography by weakly supervised deep learning, in-vivo results. IEEE J Biomed Health Inform. 2020;24(4):957–64.CrossRef van Sloun RJG, Demi L. Localizing B-lines in lung ultrasonography by weakly supervised deep learning, in-vivo results. IEEE J Biomed Health Inform. 2020;24(4):957–64.CrossRef
Metadata
Title
Automated lung ultrasound image assessment using artificial intelligence to identify fluid overload in dialysis patients
Authors
Grace Feng Ling Tan
Tiehua Du
Justin Shuang Liu
Chung Cheen Chai
Chan Maung Nyein
Allen Yan Lun Liu
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Nephrology / Issue 1/2022
Electronic ISSN: 1471-2369
DOI
https://doi.org/10.1186/s12882-022-03044-7

Other articles of this Issue 1/2022

BMC Nephrology 1/2022 Go to the issue