Skip to main content
Top
Published in: BMC Cardiovascular Disorders 1/2020

Open Access 01-12-2020 | Air Embolism | Case report

Transthoracic echocardiography-monitored CO2-insufflation esophageal endoscopy for diagnosis of Atrioesophageal fistula and prevention of iatrogenic air embolism: a case report

Authors: Bing Rong, Xiquan Zhang, Hui Tian, Hongyu Zhang, Ning Zhong, Jingquan Zhong

Published in: BMC Cardiovascular Disorders | Issue 1/2020

Login to get access

Abstract

Background

Atrioesophageal fistula (AEF) is the most fatal complication associated with catheter ablation for atrial fibrillation and cannot be easily detected when thoracic contrast-enhanced computed tomography (CT) is normal.

Case presentation

In this report, we described a diagnostic tool for detecting AEF with doubtful chest CT in which we introduced CO2-insufflation esophageal endoscopy with transthoracic echocardiography monitoring. Using this modified esophageal endoscopy, AEF was established due to the presence of both esophageal lesions and bubbles into the left atrium. That way, our patient accepted to be operated in time with good clinical prognosis.

Conclusions

This modified esophageal endoscopy is an alternative tool for early detection of AEF when normal or doubtful CT findings present.
Appendix
Available only for authorised users
Literature
1.
go back to reference Han HC, Ha FJ, Sanders P, Spencer R, Teh AW, O'Donnell D, Farouque O, Lim HS. Atrioesophageal Fistula: Clinical Presentation, Procedural Characteristics, Diagnostic Investigations, and Treatment Outcomes. Circ Arrhythm Electrophysiol. 2017;10(11):e005579.CrossRef Han HC, Ha FJ, Sanders P, Spencer R, Teh AW, O'Donnell D, Farouque O, Lim HS. Atrioesophageal Fistula: Clinical Presentation, Procedural Characteristics, Diagnostic Investigations, and Treatment Outcomes. Circ Arrhythm Electrophysiol. 2017;10(11):e005579.CrossRef
2.
go back to reference Ha FJ, Han HC, Sanders P, Teh AW, O'Donnell D, Farouque O, Lim HS. Challenges and limitations in the diagnosis of atrioesophageal fistula. J Cardiovasc Electrophysiol. 2018;29(6):861–71.CrossRef Ha FJ, Han HC, Sanders P, Teh AW, O'Donnell D, Farouque O, Lim HS. Challenges and limitations in the diagnosis of atrioesophageal fistula. J Cardiovasc Electrophysiol. 2018;29(6):861–71.CrossRef
3.
go back to reference Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, Akar JG, Badhwar V, Brugada J, Camm J, et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2018;20(1):e1–e160.CrossRef Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, Akar JG, Badhwar V, Brugada J, Camm J, et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2018;20(1):e1–e160.CrossRef
4.
go back to reference Zellerhoff S, Lenze F, Schulz R, Eckardt L. Fatal course of esophageal stenting of an atrioesophageal fistula after atrial fibrillation ablation. Heart Rhythm. 2011;8(4):624–6.CrossRef Zellerhoff S, Lenze F, Schulz R, Eckardt L. Fatal course of esophageal stenting of an atrioesophageal fistula after atrial fibrillation ablation. Heart Rhythm. 2011;8(4):624–6.CrossRef
5.
go back to reference Lambert CR, de Marchena EJ, Bikkina M, Arcement BK. Effects of intracoronary carbon dioxide on left ventricular function in swine. Clin Cardiol. 1996;19(6):461–5.CrossRef Lambert CR, de Marchena EJ, Bikkina M, Arcement BK. Effects of intracoronary carbon dioxide on left ventricular function in swine. Clin Cardiol. 1996;19(6):461–5.CrossRef
6.
go back to reference Zhao H, Yue Q, Wang T, Wang L, Pang Z, Dong H, Yang J, Li Y, Li S. Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure. Medicine (Baltimore). 2019;98(4):e14276.CrossRef Zhao H, Yue Q, Wang T, Wang L, Pang Z, Dong H, Yang J, Li Y, Li S. Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure. Medicine (Baltimore). 2019;98(4):e14276.CrossRef
Metadata
Title
Transthoracic echocardiography-monitored CO2-insufflation esophageal endoscopy for diagnosis of Atrioesophageal fistula and prevention of iatrogenic air embolism: a case report
Authors
Bing Rong
Xiquan Zhang
Hui Tian
Hongyu Zhang
Ning Zhong
Jingquan Zhong
Publication date
01-12-2020

Other articles of this Issue 1/2020

BMC Cardiovascular Disorders 1/2020 Go to the issue