Abstract

Advanced echocardiography techniques such as speckle tracking imaging are sensitive diagnostic tools frequently used in various clinical and scientific scenarios. Importantly, imperfect reproducibility and dependence of post-processing algorithms on echocardiographic image quality are potential methodological limitations. Therefore, meticulous assessment of data quality and detailed reporting of study methodology, sample specifics, technical peculiarities and measurement conditions are crucial. Unfortunately, despite the recognized importance of this, there is still no broadly accepted standard for assessing the quality of echocardiographic images in clinical research reports. This article quintessentially highlights important shortcomings of data quality assessment and methodological study design, commonly occurring in clinical research reports using advanced echocardiography techniques. Finally, suggestions are made as to how researchers, scientific communities and biomedical journals can contribute to the ever-lasting process of improving the quality of clinical research in cardiovascular imaging.
Literature
1.
go back to reference Huang J, Yan ZN, Rui YF, Fan L, Liu C, Li J. Left ventricular short-axis systolic function changes in patients with hypertrophic cardiomyopathy detected by two-dimensional speckle tracking imaging. BMC Cardiovasc Disord. 2018;18(1):13.CrossRef Huang J, Yan ZN, Rui YF, Fan L, Liu C, Li J. Left ventricular short-axis systolic function changes in patients with hypertrophic cardiomyopathy detected by two-dimensional speckle tracking imaging. BMC Cardiovasc Disord. 2018;18(1):13.CrossRef
2.
go back to reference Chung ES, Leon AR, Tavazzi L, Sun JP, Nihoyannopoulos P, Merlino J, Abraham WT, Ghio S, Leclercq C, Bax JJ, et al. Results of the predictors of response to CRT (PROSPECT) trial. Circulation. 2008;117(20):2608–16.CrossRef Chung ES, Leon AR, Tavazzi L, Sun JP, Nihoyannopoulos P, Merlino J, Abraham WT, Ghio S, Leclercq C, Bax JJ, et al. Results of the predictors of response to CRT (PROSPECT) trial. Circulation. 2008;117(20):2608–16.CrossRef
3.
go back to reference Thorstensen A, Dalen H, Amundsen BH, Aase SA, Stoylen A. Reproducibility in echocardiographic assessment of the left ventricular global and regional function, the HUNT study. Eur J Echocardiogr. 2010;11(2):149–56.CrossRef Thorstensen A, Dalen H, Amundsen BH, Aase SA, Stoylen A. Reproducibility in echocardiographic assessment of the left ventricular global and regional function, the HUNT study. Eur J Echocardiogr. 2010;11(2):149–56.CrossRef
4.
go back to reference Wilke L, Abellan Schneyder FE, Roskopf M, Jenke AC, Heusch A, Hensel KO. Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality. Sci Rep. 2018;8(1):9185.CrossRef Wilke L, Abellan Schneyder FE, Roskopf M, Jenke AC, Heusch A, Hensel KO. Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality. Sci Rep. 2018;8(1):9185.CrossRef
5.
go back to reference Hensel KO, Roskopf M, Wilke L, Heusch A. Intraobserver and interobserver reproducibility of M-mode and B-mode acquired mitral annular plane systolic excursion (MAPSE) and its dependency on echocardiographic image quality in children. PLoS One. 2018;13(5):e0196614.CrossRef Hensel KO, Roskopf M, Wilke L, Heusch A. Intraobserver and interobserver reproducibility of M-mode and B-mode acquired mitral annular plane systolic excursion (MAPSE) and its dependency on echocardiographic image quality in children. PLoS One. 2018;13(5):e0196614.CrossRef
6.
go back to reference Tarr A, Stobe S, Trache T, Kluge JG, Varga A, Pfeiffer D, Hagendorff A. The impact of foreshortening on regional strain--a comparison of regional strain evaluation between speckle tracking and tissue velocity imaging. Ultraschall Med. 2013;34(5):446–53.CrossRef Tarr A, Stobe S, Trache T, Kluge JG, Varga A, Pfeiffer D, Hagendorff A. The impact of foreshortening on regional strain--a comparison of regional strain evaluation between speckle tracking and tissue velocity imaging. Ultraschall Med. 2013;34(5):446–53.CrossRef
7.
go back to reference Unlu S, Duchenne J, Mirea O, Pagourelias ED, Bezy S, Cvijic M, Beela AS, Thomas JD, Badano LP, Voigt JU. Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE strain standardization task force. Eur Heart J Cardiovasc Imaging. 2019. Unlu S, Duchenne J, Mirea O, Pagourelias ED, Bezy S, Cvijic M, Beela AS, Thomas JD, Badano LP, Voigt JU. Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE strain standardization task force. Eur Heart J Cardiovasc Imaging. 2019.
8.
go back to reference Gorcsan J 3rd, Tanaka H. Echocardiographic assessment of myocardial strain. J Am Coll Cardiol. 2011;58(14):1401–13.CrossRef Gorcsan J 3rd, Tanaka H. Echocardiographic assessment of myocardial strain. J Am Coll Cardiol. 2011;58(14):1401–13.CrossRef
9.
go back to reference Sanchez AA, Levy PT, Sekarski TJ, Hamvas A, Holland MR, Singh GK. Effects of frame rate on two-dimensional speckle tracking-derived measurements of myocardial deformation in premature infants. Echocardiography. 2015;32(5):839–47.CrossRef Sanchez AA, Levy PT, Sekarski TJ, Hamvas A, Holland MR, Singh GK. Effects of frame rate on two-dimensional speckle tracking-derived measurements of myocardial deformation in premature infants. Echocardiography. 2015;32(5):839–47.CrossRef
10.
go back to reference Kawamura R, Seo Y, Ishizu T, Atsumi A, Yamamoto M, Machino-Ohtsuka T, Nakajima H, Sakai S, Tanaka YO, Minami M, et al. Feasibility of left ventricular volume measurements by three-dimensional speckle tracking echocardiography depends on image quality and degree of left ventricular enlargement: validation study with cardiac magnetic resonance imaging. J Cardiol. 2014;63(3):230–8.CrossRef Kawamura R, Seo Y, Ishizu T, Atsumi A, Yamamoto M, Machino-Ohtsuka T, Nakajima H, Sakai S, Tanaka YO, Minami M, et al. Feasibility of left ventricular volume measurements by three-dimensional speckle tracking echocardiography depends on image quality and degree of left ventricular enlargement: validation study with cardiac magnetic resonance imaging. J Cardiol. 2014;63(3):230–8.CrossRef
11.
go back to reference Crowley AL, Yow E, Barnhart HX, Daubert MA, Bigelow R, Sullivan DC, Pencina M, Douglas PS. Critical Review of Current Approaches for Echocardiographic Reproducibility and Reliability Assessment in Clinical Research. J Am Soc Echocardiogr. 2016;29(12):1144–1154.e1147.CrossRef Crowley AL, Yow E, Barnhart HX, Daubert MA, Bigelow R, Sullivan DC, Pencina M, Douglas PS. Critical Review of Current Approaches for Echocardiographic Reproducibility and Reliability Assessment in Clinical Research. J Am Soc Echocardiogr. 2016;29(12):1144–1154.e1147.CrossRef
12.
go back to reference Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMC Med. 2010;8:18.CrossRef Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMC Med. 2010;8:18.CrossRef
13.
go back to reference Badano LP, Kolias TJ, Muraru D, Abraham TP, Aurigemma G, Edvardsen T, D'Hooge J, Donal E, Fraser AG, Marwick T, et al. Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/industry task force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging. 2018;19(6):591–600.CrossRef Badano LP, Kolias TJ, Muraru D, Abraham TP, Aurigemma G, Edvardsen T, D'Hooge J, Donal E, Fraser AG, Marwick T, et al. Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/industry task force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging. 2018;19(6):591–600.CrossRef
14.
go back to reference Day SJ, Altman DG. Statistics notes: blinding in clinical trials and other studies. BMJ. 2000;321(7259):504.CrossRef Day SJ, Altman DG. Statistics notes: blinding in clinical trials and other studies. BMJ. 2000;321(7259):504.CrossRef
15.
go back to reference Lijmer JG, Mol BW, Heisterkamp S, Bonsel GJ, Prins MH, van der Meulen JH, Bossuyt PM. Empirical evidence of design-related bias in studies of diagnostic tests. JAMA. 1999;282(11):1061–6.CrossRef Lijmer JG, Mol BW, Heisterkamp S, Bonsel GJ, Prins MH, van der Meulen JH, Bossuyt PM. Empirical evidence of design-related bias in studies of diagnostic tests. JAMA. 1999;282(11):1061–6.CrossRef
16.
go back to reference Levin B. On the holm, Simes, and Hochberg multiple test procedures. Am J Public Health. 1996;86(5):628–9.CrossRef Levin B. On the holm, Simes, and Hochberg multiple test procedures. Am J Public Health. 1996;86(5):628–9.CrossRef
17.
go back to reference Abozguia K, Nallur-Shivu G, Phan TT, Ahmed I, Kalra R, Weaver RA, McKenna WJ, Sanderson JE, Elliott P, Frenneaux MP. Left ventricular strain and untwist in hypertrophic cardiomyopathy: relation to exercise capacity. Am Heart J. 2010;159(5):825–32.CrossRef Abozguia K, Nallur-Shivu G, Phan TT, Ahmed I, Kalra R, Weaver RA, McKenna WJ, Sanderson JE, Elliott P, Frenneaux MP. Left ventricular strain and untwist in hypertrophic cardiomyopathy: relation to exercise capacity. Am Heart J. 2010;159(5):825–32.CrossRef
18.
go back to reference Soullier C, Obert P, Doucende G, Nottin S, Cade S, Perez-Martin A, Messner-Pellenc P, Schuster I. Exercise response in hypertrophic cardiomyopathy: blunted left ventricular deformational and twisting reserve with altered systolic-diastolic coupling. Circ Cardiovasc Imaging. 2012;5(3):324–32.CrossRef Soullier C, Obert P, Doucende G, Nottin S, Cade S, Perez-Martin A, Messner-Pellenc P, Schuster I. Exercise response in hypertrophic cardiomyopathy: blunted left ventricular deformational and twisting reserve with altered systolic-diastolic coupling. Circ Cardiovasc Imaging. 2012;5(3):324–32.CrossRef
Metadata
Title
Time to shape up – assessment and reporting standards for data quality in clinical research using echocardiographic imaging techniques require improvement
Author
Kai O. Hensel
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Cardiovascular Disorders / Issue 1/2019
Electronic ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-019-1247-4

Other articles of this Issue 1/2019

BMC Cardiovascular Disorders 1/2019 Go to the issue