Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2014

Open Access 01-12-2014 | Research article

Two-year follow-up of revision total hip arthroplasty using a ceramic revision head with a retained well-fixed femoral component: a case series

Authors: Dirk Ganzer, Lutz Forke, Ulrich Irlenbusch

Published in: Journal of Medical Case Reports | Issue 1/2014

Login to get access

Abstract

Introduction

It is known that a well-fixed stem can be left in situ when only the acetabular component and femoral head have to be changed. However, in a revision case, the use of a ceramic head on an existing taper is not recommended. Slight damages of the taper may increase the risk of a ceramic fracture. Until now in a revision case a primary ceramic-on-ceramic or ceramic-on-polyethylene pairing was changed to a metal-on-polyethylene pairing or the well-fixed stem was removed as well. During the past several years, a ceramic head with a metallic sleeve has been introduced as an option for revisions with a stem left in situ. We report short-term results of a ceramic revision head in this clinical setting.

Methods

Eight patients with a ceramic revision head were clinically and radiologically followed up two years after revision surgery. Their Harris Hip Score and visual analogue scale scores for pain and satisfaction were recorded, and their radiographs were checked for osteolysis and heterotopic ossifications.

Results

The mean Harris Hip Score increased from 46.5 points before surgery to 88.3 points 2 years after surgery. The mean visual analogue scale score for pain improved from 6.7 to 1.1, and the mean visual analogue scale for satisfaction rose from 5.1 to 8.3. The radiological results did not show osteolysis in any of the patients. Grade I heterotopic ossification according to the Brooker classification system was seen in one patient.

Conclusions

The early clinical and radiological results in this case series are in agreement with previously published studies. Ceramic revision heads with a metallic sleeve are a promising approach in the revision of a ceramic head with a well-fixed stem which can be left in situ. This solution avoids an unnecessary exchange of a well-fixed stem and thereby shortens the surgical time of the revision and may reduce the peri-operative complications.
Appendix
Available only for authorised users
Literature
1.
go back to reference Boutin P: Total arthroplasty of the hip by fitted aluminum prosthesis: experimental study and first clinical applications] [Article in French]. Rev Chir Orthop Reparatrice Appar Mot. 1972, 58: 229-246.PubMed Boutin P: Total arthroplasty of the hip by fitted aluminum prosthesis: experimental study and first clinical applications] [Article in French]. Rev Chir Orthop Reparatrice Appar Mot. 1972, 58: 229-246.PubMed
2.
go back to reference Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M: Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty. 2008, 23: 39-43. 10.1016/j.arth.2008.06.003.CrossRefPubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M: Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty. 2008, 23: 39-43. 10.1016/j.arth.2008.06.003.CrossRefPubMed
3.
go back to reference Kaddick C, Pfaff HG: Results of hip simulator testing with various wear couples. Bioceramics in Joint Arthroplasty: Proceedings of the 7th International BIOLOX Symposium. Edited by: Garino JP, Willmann G. 2002, Stuttgart, Germany: Thieme, 16-20. Kaddick C, Pfaff HG: Results of hip simulator testing with various wear couples. Bioceramics in Joint Arthroplasty: Proceedings of the 7th International BIOLOX Symposium. Edited by: Garino JP, Willmann G. 2002, Stuttgart, Germany: Thieme, 16-20.
4.
go back to reference Pulliam IT, Trousdale RT: Fracture of a ceramic femoral head after a revision operation: a case report. J Bone Joint Surg Am. 1997, 79: 118-121.PubMed Pulliam IT, Trousdale RT: Fracture of a ceramic femoral head after a revision operation: a case report. J Bone Joint Surg Am. 1997, 79: 118-121.PubMed
5.
go back to reference Holmer P, Nielsen PT: Fracture of ceramic femoral heads in total hip arthroplasty. J Arthroplasty. 1993, 8: 567-571. 10.1016/0883-5403(93)90001-K.CrossRefPubMed Holmer P, Nielsen PT: Fracture of ceramic femoral heads in total hip arthroplasty. J Arthroplasty. 1993, 8: 567-571. 10.1016/0883-5403(93)90001-K.CrossRefPubMed
6.
go back to reference Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L: Ceramics in total hip replacement. Clin Orthop Relat Res. 2005, 430: 62-71.CrossRefPubMed Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L: Ceramics in total hip replacement. Clin Orthop Relat Res. 2005, 430: 62-71.CrossRefPubMed
8.
go back to reference Wuttke V, Witte H, Kempf K, Oberbach T, Delfosse D: Influence of various types of damage on the fracture strength of ceramic femoral heads. Biomed Tech (Berl). 2011, 56: 333-339.CrossRef Wuttke V, Witte H, Kempf K, Oberbach T, Delfosse D: Influence of various types of damage on the fracture strength of ceramic femoral heads. Biomed Tech (Berl). 2011, 56: 333-339.CrossRef
9.
go back to reference Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D: Revision total hip arthroplasty performed after fracture of a ceramic femoral head: a multicenter survivorship study. J Bone Joint Surg Am. 2003, 85: 825-830.PubMed Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D: Revision total hip arthroplasty performed after fracture of a ceramic femoral head: a multicenter survivorship study. J Bone Joint Surg Am. 2003, 85: 825-830.PubMed
10.
go back to reference Park YS, Hwang SK, Choy WS, Kim YS, Moon YW, Lim SJ: Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006, 88: 780-787. 10.2106/JBJS.E.00618.CrossRefPubMed Park YS, Hwang SK, Choy WS, Kim YS, Moon YW, Lim SJ: Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006, 88: 780-787. 10.2106/JBJS.E.00618.CrossRefPubMed
11.
go back to reference Pospischill M, Knahr K: Strategies for head and inlay exchange in revision hip arthroplasty. Int Orthop. 2011, 35: 261-265. 10.1007/s00264-010-1164-8.CrossRefPubMed Pospischill M, Knahr K: Strategies for head and inlay exchange in revision hip arthroplasty. Int Orthop. 2011, 35: 261-265. 10.1007/s00264-010-1164-8.CrossRefPubMed
12.
go back to reference Hohman DW, Affonso J, Anders M: Ceramic-on-ceramic failure secondary to head-neck taper mismatch. Am J Orthop. 2011, 40: 571-573.PubMed Hohman DW, Affonso J, Anders M: Ceramic-on-ceramic failure secondary to head-neck taper mismatch. Am J Orthop. 2011, 40: 571-573.PubMed
13.
go back to reference Hannouche D, Delambre J, Zadegan F, Sedel L, Nizard R: Is there a risk in placing a ceramic head on a previously implanted trunion?. Clin Orthop Relat Res. 2010, 468: 3322-3327. 10.1007/s11999-010-1505-3.CrossRefPubMedPubMedCentral Hannouche D, Delambre J, Zadegan F, Sedel L, Nizard R: Is there a risk in placing a ceramic head on a previously implanted trunion?. Clin Orthop Relat Res. 2010, 468: 3322-3327. 10.1007/s11999-010-1505-3.CrossRefPubMedPubMedCentral
14.
go back to reference Poon ED, Lachiewicz PF: Results of isolated acetabular revisions: the fate of the unrevised femoral component. J Arthroplasty. 1998, 13: 42-49. 10.1016/S0883-5403(98)90074-2.CrossRefPubMed Poon ED, Lachiewicz PF: Results of isolated acetabular revisions: the fate of the unrevised femoral component. J Arthroplasty. 1998, 13: 42-49. 10.1016/S0883-5403(98)90074-2.CrossRefPubMed
15.
go back to reference de Thomasson E, Conso C, Mazel C: A well-fixed femoral stem facing a failed acetabular component: to exchange or not? A 5- to 15-year follow-up study. Orthop Traumatol Surg Res. 2012, 98: 24-29. 10.1016/j.otsr.2011.08.014.CrossRefPubMed de Thomasson E, Conso C, Mazel C: A well-fixed femoral stem facing a failed acetabular component: to exchange or not? A 5- to 15-year follow-up study. Orthop Traumatol Surg Res. 2012, 98: 24-29. 10.1016/j.otsr.2011.08.014.CrossRefPubMed
16.
go back to reference Kessler S, Kinkel S, Kafer W, Puhl W, Schochat T: Influence of operation duration on perioperative morbidity in revision total hip arthroplasty. Acta Orthop Belg. 2003, 69: 328-333.PubMed Kessler S, Kinkel S, Kafer W, Puhl W, Schochat T: Influence of operation duration on perioperative morbidity in revision total hip arthroplasty. Acta Orthop Belg. 2003, 69: 328-333.PubMed
17.
go back to reference Kinkel S, Kessler S, Mattes T, Reichel H, Käfer W: [Predictive factors of perioperative morbidity in revision total hip arthroplasty] [Article in German]. Z Orthop Ihre Grenzgeb. 2007, 145: 91-96. 10.1055/s-2007-960504.CrossRefPubMed Kinkel S, Kessler S, Mattes T, Reichel H, Käfer W: [Predictive factors of perioperative morbidity in revision total hip arthroplasty] [Article in German]. Z Orthop Ihre Grenzgeb. 2007, 145: 91-96. 10.1055/s-2007-960504.CrossRefPubMed
18.
go back to reference Habermann B, Ewald W, Rauschmann M, Zichner L, Kurth AA: Fracture of ceramic heads in total hip replacement. Arch Orthop Trauma Surg. 2006, 126: 464-470. 10.1007/s00402-006-0173-y.CrossRefPubMed Habermann B, Ewald W, Rauschmann M, Zichner L, Kurth AA: Fracture of ceramic heads in total hip replacement. Arch Orthop Trauma Surg. 2006, 126: 464-470. 10.1007/s00402-006-0173-y.CrossRefPubMed
19.
go back to reference Solarino G, Piazzolla A, Mori CM, Moretti L, Patella S, Notarnicola A: Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients. BMC Musculoskelet Disord. 2011, 12: 32-10.1186/1471-2474-12-32.CrossRefPubMedPubMedCentral Solarino G, Piazzolla A, Mori CM, Moretti L, Patella S, Notarnicola A: Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients. BMC Musculoskelet Disord. 2011, 12: 32-10.1186/1471-2474-12-32.CrossRefPubMedPubMedCentral
20.
go back to reference Kempf I, Semlitsch M: Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg. 1990, 109: 284-287. 10.1007/BF00419946.CrossRefPubMed Kempf I, Semlitsch M: Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg. 1990, 109: 284-287. 10.1007/BF00419946.CrossRefPubMed
21.
go back to reference Begand S, Oberbach T, Glien W: Tribological behaviour of an alumina toughened zirconia ceramic for an application in joint prostheses. Key Eng Mater. 2006, 309–311: 1261-1264.CrossRef Begand S, Oberbach T, Glien W: Tribological behaviour of an alumina toughened zirconia ceramic for an application in joint prostheses. Key Eng Mater. 2006, 309–311: 1261-1264.CrossRef
22.
go back to reference DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976, 121: 20-32.PubMed DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976, 121: 20-32.PubMed
23.
go back to reference Gruen TA, McNeice GM, Amstutz HC: “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979, 141: 17-27.PubMed Gruen TA, McNeice GM, Amstutz HC: “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979, 141: 17-27.PubMed
24.
go back to reference Brooker AF, Bowerman JW, Robinson RA, Riley LH: Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am. 1973, 55: 1629-1632.PubMed Brooker AF, Bowerman JW, Robinson RA, Riley LH: Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am. 1973, 55: 1629-1632.PubMed
25.
go back to reference Haddad RJ, Cook SD, Brinker MR: A comparison of three varieties of noncemented porous-coated hip replacement. J Bone Joint Surg Br. 1990, 72: 2-8.PubMed Haddad RJ, Cook SD, Brinker MR: A comparison of three varieties of noncemented porous-coated hip replacement. J Bone Joint Surg Br. 1990, 72: 2-8.PubMed
26.
go back to reference D’Antonio JA, Capello WN, Naughton M: Ceramic bearings for total hip arthroplasty have high survivorship at 10 years. Clin Orthop Relat Res. 2012, 470: 373-381. 10.1007/s11999-011-2076-7.CrossRefPubMed D’Antonio JA, Capello WN, Naughton M: Ceramic bearings for total hip arthroplasty have high survivorship at 10 years. Clin Orthop Relat Res. 2012, 470: 373-381. 10.1007/s11999-011-2076-7.CrossRefPubMed
27.
go back to reference Thorey F, Sakdinakiattikoon M, Thiengwittayaporn S, Windhagen H: Early results of revision hip arthroplasty using a ceramic revision ball head. Semin Arthroplasty. 2011, 22: 284-289. 10.1053/j.sart.2011.09.008.CrossRef Thorey F, Sakdinakiattikoon M, Thiengwittayaporn S, Windhagen H: Early results of revision hip arthroplasty using a ceramic revision ball head. Semin Arthroplasty. 2011, 22: 284-289. 10.1053/j.sart.2011.09.008.CrossRef
Metadata
Title
Two-year follow-up of revision total hip arthroplasty using a ceramic revision head with a retained well-fixed femoral component: a case series
Authors
Dirk Ganzer
Lutz Forke
Ulrich Irlenbusch
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2014
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-8-434

Other articles of this Issue 1/2014

Journal of Medical Case Reports 1/2014 Go to the issue