Skip to main content
Top
Published in: International Orthopaedics 2/2011

01-02-2011 | Review

Strategies for head and inlay exchange in revision hip arthroplasty

Authors: Martin Pospischill, Karl Knahr

Published in: International Orthopaedics | Issue 2/2011

Login to get access

Abstract

Due to the increasing number of total hip arthroplasties performed during the last three decades and the limited long-term survival, mainly because of wear, the number of revisions has increased during the last two years. If the implant itself is still considered to be stable, only head and inlay exchange is necessary. This requires comprehensive knowledge of the characteristics of the articulating materials by the surgeon as the wrong choice of wear couple can lead to early failure for a second time. The aim of this paper is to present considerations and strategies for head and inlay exchange in case of failure, either due to wear of the articulation material or of other indications for revision hip arthroplasty.
Literature
2.
go back to reference Harris WH (2001) Wear and periprosthetic osteolysis: the problem. Clin Orthop Relat Res 393:66–70CrossRefPubMed Harris WH (2001) Wear and periprosthetic osteolysis: the problem. Clin Orthop Relat Res 393:66–70CrossRefPubMed
3.
4.
go back to reference Harris WH (2004) Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros. Clin Orthop Relat Res 429:63–67CrossRefPubMed Harris WH (2004) Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros. Clin Orthop Relat Res 429:63–67CrossRefPubMed
5.
go back to reference Silva M, Heisel C, Schmalzried TP (2005) Metal-on-metal total hip replacement. Clin Orthop Relat Res 430:53–61CrossRefPubMed Silva M, Heisel C, Schmalzried TP (2005) Metal-on-metal total hip replacement. Clin Orthop Relat Res 430:53–61CrossRefPubMed
6.
go back to reference Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L (2002) Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84-A(1):69–77PubMed Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L (2002) Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84-A(1):69–77PubMed
7.
go back to reference MacDonald SJ (2004) Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res 429:86–93CrossRefPubMed MacDonald SJ (2004) Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res 429:86–93CrossRefPubMed
8.
go back to reference Barrack RL, Burak C, Skinner HB (2004) Concerns about ceramics in THA. Clin Orthop Relat Res 429:73–79CrossRefPubMed Barrack RL, Burak C, Skinner HB (2004) Concerns about ceramics in THA. Clin Orthop Relat Res 429:73–79CrossRefPubMed
9.
go back to reference Zichner L, Lindenfeld T (1997) In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metal-polyethylene. Orthopade 26(2):129–134PubMed Zichner L, Lindenfeld T (1997) In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metal-polyethylene. Orthopade 26(2):129–134PubMed
10.
go back to reference Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, Miller RK (2001) Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83-A(11):1688–1694PubMed Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, Miller RK (2001) Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83-A(11):1688–1694PubMed
12.
go back to reference Greenwald AS, Garino JP (2001) Alternative bearing surfaces: the good, the bad, and the ugly. J Bone Joint Surg Am 83-A(Suppl 2 Pt 2):68–72PubMed Greenwald AS, Garino JP (2001) Alternative bearing surfaces: the good, the bad, and the ugly. J Bone Joint Surg Am 83-A(Suppl 2 Pt 2):68–72PubMed
14.
go back to reference Karamat L, Pinggera O, Knahr K (2005) Blood analysis for trace metals in metal-on-metal, ceramic-on-ceramic and metal-on-cross-linked PE bearings in total hip arthroplasty. Hip International 15:136–142 Karamat L, Pinggera O, Knahr K (2005) Blood analysis for trace metals in metal-on-metal, ceramic-on-ceramic and metal-on-cross-linked PE bearings in total hip arthroplasty. Hip International 15:136–142
15.
go back to reference Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R (2003) Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am 85-A(11):2168–2173PubMed Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R (2003) Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am 85-A(11):2168–2173PubMed
16.
go back to reference Allen MJ, Myer BJ, Millett PJ, Rushton N (1997) The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro. J Bone Joint Surg Br 79(3):475–482CrossRefPubMed Allen MJ, Myer BJ, Millett PJ, Rushton N (1997) The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro. J Bone Joint Surg Br 79(3):475–482CrossRefPubMed
17.
go back to reference Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83-A(3):428–436PubMed Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83-A(3):428–436PubMed
19.
go back to reference Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36. doi:10.2106/JBJS.A.02039 CrossRefPubMed Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36. doi:10.​2106/​JBJS.​A.​02039 CrossRefPubMed
23.
go back to reference Mittelmeier H, Heisel J (1992) Sixteen-years' experience with ceramic hip prostheses. Clin Orthop Relat Res 282:64–72PubMed Mittelmeier H, Heisel J (1992) Sixteen-years' experience with ceramic hip prostheses. Clin Orthop Relat Res 282:64–72PubMed
24.
25.
go back to reference Kempf I, Semlitsch M (1990) Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 109(5):284–287CrossRefPubMed Kempf I, Semlitsch M (1990) Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 109(5):284–287CrossRefPubMed
27.
go back to reference Lee SC, Jung KA, Nam CH, Kim TH, Ahn NK, Hwang SH (2010) Acetabular screw head-induced ceramic acetabular liner fracture in cementless ceramic-on-ceramic total hip arthroplasty. Orthopedics 33(5). doi:10.3928/01477447-20100329-30 Lee SC, Jung KA, Nam CH, Kim TH, Ahn NK, Hwang SH (2010) Acetabular screw head-induced ceramic acetabular liner fracture in cementless ceramic-on-ceramic total hip arthroplasty. Orthopedics 33(5). doi:10.​3928/​01477447-20100329-30
28.
go back to reference Knahr K, Beck R (2002) An instrument for the insertion of ceramic liners. In: Garino JP, Willmann G (eds) Bioceramics in joint arthroplasty. Proceedings of the 7th International BIOLOX Symposium. Thieme, Stuttgart, pp 71–75 Knahr K, Beck R (2002) An instrument for the insertion of ceramic liners. In: Garino JP, Willmann G (eds) Bioceramics in joint arthroplasty. Proceedings of the 7th International BIOLOX Symposium. Thieme, Stuttgart, pp 71–75
Metadata
Title
Strategies for head and inlay exchange in revision hip arthroplasty
Authors
Martin Pospischill
Karl Knahr
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1164-8

Other articles of this Issue 2/2011

International Orthopaedics 2/2011 Go to the issue