Skip to main content
Top
Published in: Radiation Oncology 1/2009

Open Access 01-12-2009 | Methodology

Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy

Authors: Giorgia Nicolini, Alessandro Clivio, Antonella Fogliata, Eugenio Vanetti, Luca Cozzi

Published in: Radiation Oncology | Issue 1/2009

Login to get access

Abstract

Purpose

A study was performed comparing dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) on patients with bilateral breast carcinoma.

Materials and methods

Plans for IMRT and RA, were optimised for 10 patients prescribing 50 Gy to the breast (PTVII, 2.0 Gy/fraction) and 60 Gy to the tumour bed (PTVI, 2.4 Gy/fraction). Objectives were: for PTVs V90%>95%, Dmax<107%; Mean lung dose MLD<15 Gy, V20 Gy<22%; heart involvement was to be minimised. The MU and delivery time measured treatment efficiency. Pre-treatment dosimetry was performed using EPID and a 2D-array based methods.

Results

For PTVII minus PTVI, V90% was 97.8 ± 3.4% for RA and 94.0 ± 3.5% for IMRT (findings are reported as mean ± 1 standard deviation); D5%-D95% (homogeneity) was 7.3 ± 1.4 Gy (RA) and 11.0 ± 1.1 Gy (IMRT). Conformity index (V95%/VPTVII) was 1.10 ± 0.06 (RA) and 1.14 ± 0.09 (IMRT). MLD was <9.5 Gy for all cases on each lung, V20 Gy was 9.7 ± 1.3% (RA) and 12.8 ± 2.5% (IMRT) on left lung, similar for right lung. Mean dose to heart was 6.0 ± 2.7 Gy (RA) and 7.4 ± 2.5 Gy (IMRT). MU resulted in 796 ± 121 (RA) and 1398 ± 301 (IMRT); the average measured treatment time was 3.0 ± 0.1 minutes (RA) and 11.5 ± 2.0 (IMRT). From pre-treatment dosimetry, % of field area with γ <1 resulted 98.8 ± 1.3% and 99.1 ± 1.5% for RA and IMRT respectively with EPID and 99.1 ± 1.8% and 99.5 ± 1.3% with 2D-array (ΔD = 3% and DTA = 3 mm).

Conclusion

RapidArc showed dosimetric improvements with respect to IMRT, delivery parameters confirmed its logistical advantages, pre-treatment dosimetry proved its reliability.
Appendix
Available only for authorised users
Literature
1.
go back to reference Duthoy W, De Gersem W, Vergote K, Botenberf T, Derie C, Smeets P, De Wagter C, De Neve W: Clinical implementation of intensity modulated arc therapy (IMAT) for rectal cancer. Int J Radiat Oncol Biol Phys 2004, 60: 794-806.CrossRefPubMed Duthoy W, De Gersem W, Vergote K, Botenberf T, Derie C, Smeets P, De Wagter C, De Neve W: Clinical implementation of intensity modulated arc therapy (IMAT) for rectal cancer. Int J Radiat Oncol Biol Phys 2004, 60: 794-806.CrossRefPubMed
2.
go back to reference Yu CX: Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. Phys Med Biol 1995, 40: 1435-1449. 10.1088/0031-9155/40/9/004CrossRefPubMed Yu CX: Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. Phys Med Biol 1995, 40: 1435-1449. 10.1088/0031-9155/40/9/004CrossRefPubMed
3.
go back to reference Yu CX, Li XA, Ma L, Chen D, Naqvi S, Shepard D, Sarfaraz M, Holmes TW, Suntharalingam M, Mansfield CM: Clinical implementation of intensity-modulated arc therapy. Int J Radiat Oncol Biol Phys 2002, 53: 453-463.CrossRefPubMed Yu CX, Li XA, Ma L, Chen D, Naqvi S, Shepard D, Sarfaraz M, Holmes TW, Suntharalingam M, Mansfield CM: Clinical implementation of intensity-modulated arc therapy. Int J Radiat Oncol Biol Phys 2002, 53: 453-463.CrossRefPubMed
4.
go back to reference Otto K: Volumetric Modulated Arc Therapy: IMRT in a single arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed Otto K: Volumetric Modulated Arc Therapy: IMRT in a single arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed
5.
go back to reference Cozzi L, Dinshaw KA, Shrivastava SK, Mahantshetty U, Engineer R, Deshpande DD, Jamema SV, Vanetti E, Clivio A, Nicolini G, Fogliata A: A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008, 89: 180-91. 10.1016/j.radonc.2008.06.013CrossRefPubMed Cozzi L, Dinshaw KA, Shrivastava SK, Mahantshetty U, Engineer R, Deshpande DD, Jamema SV, Vanetti E, Clivio A, Nicolini G, Fogliata A: A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008, 89: 180-91. 10.1016/j.radonc.2008.06.013CrossRefPubMed
6.
go back to reference Fogliata A, Clivio A, Nicolini G, Vanetti E, Cozzi L: Intensity modulation with photons for benign intracranial tumours. A planning comparison of volumetric single arc, helical arc and fixed gantry techniques. Radiother Oncol 2008, 89: 254-62. 10.1016/j.radonc.2008.07.021CrossRefPubMed Fogliata A, Clivio A, Nicolini G, Vanetti E, Cozzi L: Intensity modulation with photons for benign intracranial tumours. A planning comparison of volumetric single arc, helical arc and fixed gantry techniques. Radiother Oncol 2008, 89: 254-62. 10.1016/j.radonc.2008.07.021CrossRefPubMed
7.
go back to reference Palma D, Vollans E, James K, Nakano S, Moiseenko V, Shaffer R, McKenzie M, Morris J, Otto K: Volumetric modulated arc therapy for delivery of prostate radiotherapy. Comparison with intensity modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 996-1001.CrossRefPubMed Palma D, Vollans E, James K, Nakano S, Moiseenko V, Shaffer R, McKenzie M, Morris J, Otto K: Volumetric modulated arc therapy for delivery of prostate radiotherapy. Comparison with intensity modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 996-1001.CrossRefPubMed
8.
go back to reference Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2008, 1-6. Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2008, 1-6.
9.
go back to reference Vanetti E, Clivio A, Nicolini G, Fogliata A, Gosh-Laskar S, Agarwal J, Upreti R, Budrukkar A, Murthy V, Deshpande D, Shrivastava S, Dinshaw K, Cozzi L: Volumetric arc modulated radiotherapy for carcinomas of the oro-pharynx, hypo.pharynx and larynx. A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009,92(1):111-7. 10.1016/j.radonc.2008.12.008CrossRefPubMed Vanetti E, Clivio A, Nicolini G, Fogliata A, Gosh-Laskar S, Agarwal J, Upreti R, Budrukkar A, Murthy V, Deshpande D, Shrivastava S, Dinshaw K, Cozzi L: Volumetric arc modulated radiotherapy for carcinomas of the oro-pharynx, hypo.pharynx and larynx. A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009,92(1):111-7. 10.1016/j.radonc.2008.12.008CrossRefPubMed
10.
go back to reference Verbakel WFAR, Senan S, Lagerwaard FJ, Hoffmans D, Slotman BJ: RapidArc vs. IMRT Planning: A comparative Study with Dosimetric Validation for Head and Neck, Glioma and Pancreas Cancer. Int J Radiat Oncol Biol Phys 2008, 72: S596-597.CrossRef Verbakel WFAR, Senan S, Lagerwaard FJ, Hoffmans D, Slotman BJ: RapidArc vs. IMRT Planning: A comparative Study with Dosimetric Validation for Head and Neck, Glioma and Pancreas Cancer. Int J Radiat Oncol Biol Phys 2008, 72: S596-597.CrossRef
11.
go back to reference Clivio A, Fogliata A, Franzetti-Pellanda A, Nicolini G, Vanetti E, Wyttenbach R, Cozzi L: Volumetric arc modulated radiotherapy for carcinoams of the anal canal. A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009,92(1):118-24. Epub 2009 Jan 30. 10.1016/j.radonc.2008.12.020CrossRefPubMed Clivio A, Fogliata A, Franzetti-Pellanda A, Nicolini G, Vanetti E, Wyttenbach R, Cozzi L: Volumetric arc modulated radiotherapy for carcinoams of the anal canal. A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009,92(1):118-24. Epub 2009 Jan 30. 10.1016/j.radonc.2008.12.020CrossRefPubMed
12.
go back to reference Fogliata A, Nicolini G, Alber M, Asell M, Dobler B, El-Haddad M, Hardemark B, Jelen U, Kania A, Larsson M, Lohr F, Munger T, Negri E, Rodrigues C, Cozzi L: IMRT for breast, a planning study. Radiother Oncol 2005, 76: 300-310. 10.1016/j.radonc.2005.08.004CrossRefPubMed Fogliata A, Nicolini G, Alber M, Asell M, Dobler B, El-Haddad M, Hardemark B, Jelen U, Kania A, Larsson M, Lohr F, Munger T, Negri E, Rodrigues C, Cozzi L: IMRT for breast, a planning study. Radiother Oncol 2005, 76: 300-310. 10.1016/j.radonc.2005.08.004CrossRefPubMed
13.
go back to reference Fogliata A, Bolsi A, Cozzi L: Critical appraisal of treatment techniques based on conventional photon beams, intensity modulated photon beams and proton beams for therapy of intact breast. Radiother Oncol 2002, 62: 137-145. 10.1016/S0167-8140(01)00476-5CrossRefPubMed Fogliata A, Bolsi A, Cozzi L: Critical appraisal of treatment techniques based on conventional photon beams, intensity modulated photon beams and proton beams for therapy of intact breast. Radiother Oncol 2002, 62: 137-145. 10.1016/S0167-8140(01)00476-5CrossRefPubMed
14.
go back to reference Hurkmans C, Meijer G, van Vliet-Vroegindeweij C, Sangen M, Cassee J: High dose simultaneously integrated breast boost using intensity modulated radiotherapy and inverse optimisation. Int J Radiat Oncol Biol Phys 2006, 66: 923-930.CrossRefPubMed Hurkmans C, Meijer G, van Vliet-Vroegindeweij C, Sangen M, Cassee J: High dose simultaneously integrated breast boost using intensity modulated radiotherapy and inverse optimisation. Int J Radiat Oncol Biol Phys 2006, 66: 923-930.CrossRefPubMed
15.
go back to reference Singla R, King S, Albuquerque K, Creech S, Dogan N: Simultaneous integrated boost intensity modulated radiation therapy (SIB-IMRT) in the treatment of early stage left sided breast carcinoma. Med Dosim 2006, 31: 190-196. 10.1016/j.meddos.2005.11.001CrossRefPubMed Singla R, King S, Albuquerque K, Creech S, Dogan N: Simultaneous integrated boost intensity modulated radiation therapy (SIB-IMRT) in the treatment of early stage left sided breast carcinoma. Med Dosim 2006, 31: 190-196. 10.1016/j.meddos.2005.11.001CrossRefPubMed
16.
go back to reference Laan H, Dolsma W, Maduro J, Korevaar E, Hollander M, Langendijk J: Three.dimensional conformal simultaneously integrated boost technique for breast conserving radiotherapy. Int J Radiat Oncol Biol Phys 2007, 68: 1018-1023.CrossRefPubMed Laan H, Dolsma W, Maduro J, Korevaar E, Hollander M, Langendijk J: Three.dimensional conformal simultaneously integrated boost technique for breast conserving radiotherapy. Int J Radiat Oncol Biol Phys 2007, 68: 1018-1023.CrossRefPubMed
17.
go back to reference Jobsen J, Palen J, Ong F, Meerwaldt J: Synchronous bilateral breast cancer: prognostic value and incidence. Breast 2003, 12: 83-88. 10.1016/S0960-9776(02)00278-3CrossRefPubMed Jobsen J, Palen J, Ong F, Meerwaldt J: Synchronous bilateral breast cancer: prognostic value and incidence. Breast 2003, 12: 83-88. 10.1016/S0960-9776(02)00278-3CrossRefPubMed
18.
go back to reference Skowronek J, Piotrowski T: Bilateral breast cancer. Neoplasma 2002, 49: 49-54.PubMed Skowronek J, Piotrowski T: Bilateral breast cancer. Neoplasma 2002, 49: 49-54.PubMed
19.
go back to reference Yamauchi C, Mitsumori M, Nagata Y, Kokubo M, Inamoto T, Mise K, Kodama H, Hiraoka M: Bilateral breast-conserving therapy for bilateral breast cancer: results and consideration of radiation technique. Breast Cancer 2005, 12: 135-9. 10.2325/jbcs.12.135CrossRefPubMed Yamauchi C, Mitsumori M, Nagata Y, Kokubo M, Inamoto T, Mise K, Kodama H, Hiraoka M: Bilateral breast-conserving therapy for bilateral breast cancer: results and consideration of radiation technique. Breast Cancer 2005, 12: 135-9. 10.2325/jbcs.12.135CrossRefPubMed
20.
go back to reference Graham M, Purdy J, Emami B, Harms W, Bosch W, Lockett MA, Perez CA: Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non small cell lung cancer (NSLC). Int J Radiat Oncol Biol Phys 1999, 45: 323-329.CrossRefPubMed Graham M, Purdy J, Emami B, Harms W, Bosch W, Lockett MA, Perez CA: Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non small cell lung cancer (NSLC). Int J Radiat Oncol Biol Phys 1999, 45: 323-329.CrossRefPubMed
21.
go back to reference Kwa SLS, Lebesque JV, Theuws JCM, Theuws JC, Marks LB, Munley MT, Bentel G, Oetzel D, Spahn U, Graham MV, Drzymala RE, Purdy JA, Lichter AS, Martel MK, Ten Haken RK: Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients. Int J Radiat Oncol Biol Phys 1998, 42: 1-9.CrossRefPubMed Kwa SLS, Lebesque JV, Theuws JCM, Theuws JC, Marks LB, Munley MT, Bentel G, Oetzel D, Spahn U, Graham MV, Drzymala RE, Purdy JA, Lichter AS, Martel MK, Ten Haken RK: Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients. Int J Radiat Oncol Biol Phys 1998, 42: 1-9.CrossRefPubMed
22.
go back to reference Oetzel D, Schraube P, Hensley F, Sroka-Perez G, Menke M, Flentje M: Estimation of pneumonitis risk in three-dimensional treatment planning using dose-volume histogram analysis. Int J Radiat Oncol Biol Phys 1995, 33: 455-460.CrossRefPubMed Oetzel D, Schraube P, Hensley F, Sroka-Perez G, Menke M, Flentje M: Estimation of pneumonitis risk in three-dimensional treatment planning using dose-volume histogram analysis. Int J Radiat Oncol Biol Phys 1995, 33: 455-460.CrossRefPubMed
23.
go back to reference Fogliata A, Vanetti E, Albers D, Brink C, Clivio A, Knöös T, Nicolini G, Cozzi L: On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations. Phys Med Biol 2007, 52: 1363-1385. 10.1088/0031-9155/52/5/011CrossRefPubMed Fogliata A, Vanetti E, Albers D, Brink C, Clivio A, Knöös T, Nicolini G, Cozzi L: On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations. Phys Med Biol 2007, 52: 1363-1385. 10.1088/0031-9155/52/5/011CrossRefPubMed
24.
go back to reference Ulmer W, Pyyry J, Kaissl W: A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol 2005, 50: 1767-90. 10.1088/0031-9155/50/8/010CrossRefPubMed Ulmer W, Pyyry J, Kaissl W: A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol 2005, 50: 1767-90. 10.1088/0031-9155/50/8/010CrossRefPubMed
25.
go back to reference Chui C, LoSasso T, Spirou S: Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. Med Phys 1994, 21: 1237-1244. 10.1118/1.597206CrossRefPubMed Chui C, LoSasso T, Spirou S: Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. Med Phys 1994, 21: 1237-1244. 10.1118/1.597206CrossRefPubMed
26.
go back to reference Spirou S, Chui C: A gradient inverse planning algorithm with dose-volume constrains. Med Phys 1998, 25: 321-333. 10.1118/1.598202CrossRefPubMed Spirou S, Chui C: A gradient inverse planning algorithm with dose-volume constrains. Med Phys 1998, 25: 321-333. 10.1118/1.598202CrossRefPubMed
27.
go back to reference Otto K: Letter to the editor on ‚Single Arc IMRT?’. Phys Med Biol 2009, 54: L37-L41. 10.1088/0031-9155/54/8/L03CrossRefPubMed Otto K: Letter to the editor on ‚Single Arc IMRT?’. Phys Med Biol 2009, 54: L37-L41. 10.1088/0031-9155/54/8/L03CrossRefPubMed
28.
go back to reference Nicolini G, Vanetti E, Clivio A, Fogliata A, Korreman S, Bocanek J, Cozzi L: The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy. Radiat Oncol 2008, 9: 3-24. Nicolini G, Vanetti E, Clivio A, Fogliata A, Korreman S, Bocanek J, Cozzi L: The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy. Radiat Oncol 2008, 9: 3-24.
29.
go back to reference Nicolini G, Fogliata A, Vanetti E, Clivio A, Cozzi L: GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications. Med Phys 2006, 33: 2839-2851. 10.1118/1.2218314CrossRefPubMed Nicolini G, Fogliata A, Vanetti E, Clivio A, Cozzi L: GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications. Med Phys 2006, 33: 2839-2851. 10.1118/1.2218314CrossRefPubMed
30.
go back to reference Deschavanne PJ, Fertil B, Chavaudra N, Malaise EP: The relationship between radiosensitivity and repair of potentially lethal damage in human tumor cell lines with implications for radioresponsiveness. Radiat Res 1990, 122: 29-37. 10.2307/3577579CrossRefPubMed Deschavanne PJ, Fertil B, Chavaudra N, Malaise EP: The relationship between radiosensitivity and repair of potentially lethal damage in human tumor cell lines with implications for radioresponsiveness. Radiat Res 1990, 122: 29-37. 10.2307/3577579CrossRefPubMed
31.
go back to reference Källmann P, Agren A, Brahme A: Tumour and normal tissue responses to fractionated non-uniform dose delivery. Int J Radiat Biol Phys 1992, 62: 249-262. 10.1080/09553009214552071CrossRef Källmann P, Agren A, Brahme A: Tumour and normal tissue responses to fractionated non-uniform dose delivery. Int J Radiat Biol Phys 1992, 62: 249-262. 10.1080/09553009214552071CrossRef
32.
go back to reference Agren-Cronqvist A: Quantification of the response of heterogeneous tumours and organized normal tissues to fractionated radiotherapy. In PhD Thesis. Stockholm University; 1995. Agren-Cronqvist A: Quantification of the response of heterogeneous tumours and organized normal tissues to fractionated radiotherapy. In PhD Thesis. Stockholm University; 1995.
33.
go back to reference Low DA, Harms WB, Mutic S, Purdy JA: A technique for quantitative evaluation of dose distributions. Med Phys 1998, 25: 656-661. 10.1118/1.598248CrossRefPubMed Low DA, Harms WB, Mutic S, Purdy JA: A technique for quantitative evaluation of dose distributions. Med Phys 1998, 25: 656-661. 10.1118/1.598248CrossRefPubMed
34.
go back to reference Korreman S, Medin J, Kjær-Kristoffersen F: Dosimetric verification of RapidArc treatment delivery. Acta Oncol 2008, 1-7. Korreman S, Medin J, Kjær-Kristoffersen F: Dosimetric verification of RapidArc treatment delivery. Acta Oncol 2008, 1-7.
35.
go back to reference Korreman S, Pedersen A, Josipovic M, Aarup L, Nottrup T, Specht L, Nystrom H: Reduction of cardiac and pulmonary complication probabilities after breathing adapted radiotherapy for breast cancer. Int J Radiat Oncol Biol Phys 2006, 65: 1375-1380.CrossRefPubMed Korreman S, Pedersen A, Josipovic M, Aarup L, Nottrup T, Specht L, Nystrom H: Reduction of cardiac and pulmonary complication probabilities after breathing adapted radiotherapy for breast cancer. Int J Radiat Oncol Biol Phys 2006, 65: 1375-1380.CrossRefPubMed
36.
go back to reference Zimmerman J, Korreman S, Persson G, Cattell H, Svatos M, Sawant A, Venkat R, Carlson D, Keall P: DMLC motion tracking of moving targets for intensity modulated arc therapy treatment. A feasibility study. Acta Oncol 2009,48(2):245-50. 10.1080/02841860802266722CrossRefPubMed Zimmerman J, Korreman S, Persson G, Cattell H, Svatos M, Sawant A, Venkat R, Carlson D, Keall P: DMLC motion tracking of moving targets for intensity modulated arc therapy treatment. A feasibility study. Acta Oncol 2009,48(2):245-50. 10.1080/02841860802266722CrossRefPubMed
Metadata
Title
Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy
Authors
Giorgia Nicolini
Alessandro Clivio
Antonella Fogliata
Eugenio Vanetti
Luca Cozzi
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2009
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-4-27

Other articles of this Issue 1/2009

Radiation Oncology 1/2009 Go to the issue