Skip to main content
Top
Published in: Cardiovascular Ultrasound 1/2009

Open Access 01-12-2009 | Research

Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

Authors: Aristomenis Manouras, Arben Shala, Evangelia Nyktari, Kambiz Shahgaldi, Reidar Winter, Panagiotis Vardas, Lars-Åke Brodin, Jacek Nowak

Published in: Cardiovascular Ultrasound | Issue 1/2009

Login to get access

Abstract

Background

Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated.

Methods

Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 ± 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used.

Results

Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 ± 0.54 cm/sec in septal and 0.09 ± 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 ± 0.74 mm in septal and 0.02 ± 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases).

Conclusion

LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Isaaz K, Thompson A, Ethevenot G, Cloez JL, Brembilla B, Pernot C: Doppler echocardiographic measurement of low velocity motion of the left ventricular posterior wall. Am J Cardiol 1989, 64: 66-75.CrossRefPubMed Isaaz K, Thompson A, Ethevenot G, Cloez JL, Brembilla B, Pernot C: Doppler echocardiographic measurement of low velocity motion of the left ventricular posterior wall. Am J Cardiol 1989, 64: 66-75.CrossRefPubMed
2.
go back to reference McDicken WN, Sutherland GR, Moran CM, Gordon LN: Colour Doppler velocity imaging of the myocardium. Ultrasound Med Biol 1992, 18: 651-654.CrossRefPubMed McDicken WN, Sutherland GR, Moran CM, Gordon LN: Colour Doppler velocity imaging of the myocardium. Ultrasound Med Biol 1992, 18: 651-654.CrossRefPubMed
3.
go back to reference Sutherland GR, Bijnens B, McDicken WN: Tissue Doppler Echocardiography: Historical Perspective and Technological Considerations. Echocardiography 1999, 16: 445-453.CrossRefPubMed Sutherland GR, Bijnens B, McDicken WN: Tissue Doppler Echocardiography: Historical Perspective and Technological Considerations. Echocardiography 1999, 16: 445-453.CrossRefPubMed
4.
go back to reference Nagueh SF, Bachinski LL, Meyer D, Hill R, Zoghbi WA, Tam JW, Quinones MA, Roberts R, Marian AJ: Tissue Doppler imaging consistently detects myocardial abnormalities in patients with hypertrophic cardiomyopathy and provides a novel means for an early diagnosis before and independently of hypertrophy. Circulation 2001, 104: 128-130.CrossRefPubMedPubMedCentral Nagueh SF, Bachinski LL, Meyer D, Hill R, Zoghbi WA, Tam JW, Quinones MA, Roberts R, Marian AJ: Tissue Doppler imaging consistently detects myocardial abnormalities in patients with hypertrophic cardiomyopathy and provides a novel means for an early diagnosis before and independently of hypertrophy. Circulation 2001, 104: 128-130.CrossRefPubMedPubMedCentral
5.
go back to reference Fukuda K, Oki T, Tabata T, Iuchi A, Ito S: Regional left ventricular wall motion abnormalities in myocardial infarction and mitral annular descent velocities studied with pulsed tissue Doppler imaging. J Am Soc Echocardiogr 1998, 11: 841-848. 10.1016/S0894-7317(98)70003-3CrossRefPubMed Fukuda K, Oki T, Tabata T, Iuchi A, Ito S: Regional left ventricular wall motion abnormalities in myocardial infarction and mitral annular descent velocities studied with pulsed tissue Doppler imaging. J Am Soc Echocardiogr 1998, 11: 841-848. 10.1016/S0894-7317(98)70003-3CrossRefPubMed
6.
go back to reference Bolognesi R, Tsialtas D, Barilli AL, Manca C, Zeppellini R, Javernaro A, Cucchini F: Detection of early abnormalities of left ventricular function by hemodynamic, echo-tissue Doppler imaging, and mitral Doppler flow techniques in patients with coronary artery disease and normal ejection fraction. J Am Soc Echocardiogr 2001, 14: 764-772. 10.1067/mje.2001.113234CrossRefPubMed Bolognesi R, Tsialtas D, Barilli AL, Manca C, Zeppellini R, Javernaro A, Cucchini F: Detection of early abnormalities of left ventricular function by hemodynamic, echo-tissue Doppler imaging, and mitral Doppler flow techniques in patients with coronary artery disease and normal ejection fraction. J Am Soc Echocardiogr 2001, 14: 764-772. 10.1067/mje.2001.113234CrossRefPubMed
7.
go back to reference Sohn DW, Chai IH, Lee DJ, Kim HC, Kim HS, Oh BH, Lee MM, Park YB, Choi YS, Seo JD, Lee YW: Assessment of mitral annulus velocity by Doppler tissue imaging in the evaluation of left ventricular diastolic function. J Am Coll Cardiol 1997, 30: 474-480. 10.1016/S0735-1097(97)88335-0CrossRefPubMed Sohn DW, Chai IH, Lee DJ, Kim HC, Kim HS, Oh BH, Lee MM, Park YB, Choi YS, Seo JD, Lee YW: Assessment of mitral annulus velocity by Doppler tissue imaging in the evaluation of left ventricular diastolic function. J Am Coll Cardiol 1997, 30: 474-480. 10.1016/S0735-1097(97)88335-0CrossRefPubMed
8.
go back to reference Ommen SR, Nishimura RA, Appleton CP, Miller FA, Oh JK, Redfield MM, Tajik AJ: Clinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures: A comparative simultaneous Doppler-catheterization study. Circulation 2000, 102: 1788-1794.CrossRefPubMed Ommen SR, Nishimura RA, Appleton CP, Miller FA, Oh JK, Redfield MM, Tajik AJ: Clinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures: A comparative simultaneous Doppler-catheterization study. Circulation 2000, 102: 1788-1794.CrossRefPubMed
9.
go back to reference Garcia MJ, Rodriguez L, Ares M, Griffin BP, Klein AL, Stewart WJ, Thomas JD: Myocardial wall velocity assessment by pulsed Doppler tissue imaging: characteristic findings in normal subjects. Am Heart J 1996, 132: 648-656. 10.1016/S0002-8703(96)90251-3CrossRefPubMed Garcia MJ, Rodriguez L, Ares M, Griffin BP, Klein AL, Stewart WJ, Thomas JD: Myocardial wall velocity assessment by pulsed Doppler tissue imaging: characteristic findings in normal subjects. Am Heart J 1996, 132: 648-656. 10.1016/S0002-8703(96)90251-3CrossRefPubMed
10.
go back to reference Galiuto L, Ignone G, DeMaria AN: Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol 1998, 81: 609-614. 10.1016/S0002-9149(97)00990-9CrossRefPubMed Galiuto L, Ignone G, DeMaria AN: Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol 1998, 81: 609-614. 10.1016/S0002-9149(97)00990-9CrossRefPubMed
11.
go back to reference Donovan CL, Armstrong WF, Bach DS: Quantitative Doppler tissue imaging of the left ventricular myocardium: validation in normal subjects. Am Heart J 1995, 130: 100-104. 10.1016/0002-8703(95)90242-2CrossRefPubMed Donovan CL, Armstrong WF, Bach DS: Quantitative Doppler tissue imaging of the left ventricular myocardium: validation in normal subjects. Am Heart J 1995, 130: 100-104. 10.1016/0002-8703(95)90242-2CrossRefPubMed
12.
go back to reference Palka P, Lange A, Fleming AD, Sutherland GR, Fenn LN, McDicken WN: Doppler tissue imaging: myocardial wall motion velocities in normal subjects. J Am Soc Echocardiogr 1995, 8: 659-668. 10.1016/S0894-7317(05)80380-3CrossRefPubMed Palka P, Lange A, Fleming AD, Sutherland GR, Fenn LN, McDicken WN: Doppler tissue imaging: myocardial wall motion velocities in normal subjects. J Am Soc Echocardiogr 1995, 8: 659-668. 10.1016/S0894-7317(05)80380-3CrossRefPubMed
13.
go back to reference Sutherland GR, Stewart MJ, Groundstroem KW, Moran CM, Fleming A, Guell-Peris FJ, Riemersma RA, Fenn LN, Fox KA, McDicken WN: Color Doppler myocardial imaging: a new technique for the assessment of myocardial function. J Am Soc Echocardiogr 1994, 7: 441-458.CrossRefPubMed Sutherland GR, Stewart MJ, Groundstroem KW, Moran CM, Fleming A, Guell-Peris FJ, Riemersma RA, Fenn LN, Fox KA, McDicken WN: Color Doppler myocardial imaging: a new technique for the assessment of myocardial function. J Am Soc Echocardiogr 1994, 7: 441-458.CrossRefPubMed
14.
go back to reference Wilkenshoff UM, Sovany A, Wigstrom L, Olstad B, Lindstrom L, Engvall J, Janerot-Sjoberg B, Wranne B, Hatle L, Sutherland GR: Regional mean systolic myocardial velocity estimation by real-time color Doppler myocardial imaging: a new technique for quantifying regional systolic function. J Am Soc Echocardiogr 1998, 11: 683-692. 10.1053/je.1998.v11.a90584CrossRefPubMed Wilkenshoff UM, Sovany A, Wigstrom L, Olstad B, Lindstrom L, Engvall J, Janerot-Sjoberg B, Wranne B, Hatle L, Sutherland GR: Regional mean systolic myocardial velocity estimation by real-time color Doppler myocardial imaging: a new technique for quantifying regional systolic function. J Am Soc Echocardiogr 1998, 11: 683-692. 10.1053/je.1998.v11.a90584CrossRefPubMed
15.
go back to reference Vinereanu D, Khokhar A, Fraser AG: Reproducibility of pulsed wave tissue Doppler echocardiography. J Am Soc Echocardiogr 1999, 12: 492-499. 10.1016/S0894-7317(99)70086-6CrossRefPubMed Vinereanu D, Khokhar A, Fraser AG: Reproducibility of pulsed wave tissue Doppler echocardiography. J Am Soc Echocardiogr 1999, 12: 492-499. 10.1016/S0894-7317(99)70086-6CrossRefPubMed
16.
go back to reference Lind B, Nowak J, Dorph J, Linden J, Brodin LA: Analysis of temporal requirements for myocardial tissue velocity imaging. Eur J Echocardiogr 2002, 3: 214-219. 10.1053/euje.2002.0157CrossRefPubMed Lind B, Nowak J, Dorph J, Linden J, Brodin LA: Analysis of temporal requirements for myocardial tissue velocity imaging. Eur J Echocardiogr 2002, 3: 214-219. 10.1053/euje.2002.0157CrossRefPubMed
17.
go back to reference Manouras A, Shahgaldi K, Winter R, Nowak J, Brodin LA: Comparison between colour-coded and spectral tissue Doppler measurements of systolic and diastolic myocardial velocities: effect of temporal filtering and offline gain setting. Eur J Echocardiogr 2009, 10: 406-13. 10.1093/ejechocard/jen298CrossRefPubMed Manouras A, Shahgaldi K, Winter R, Nowak J, Brodin LA: Comparison between colour-coded and spectral tissue Doppler measurements of systolic and diastolic myocardial velocities: effect of temporal filtering and offline gain setting. Eur J Echocardiogr 2009, 10: 406-13. 10.1093/ejechocard/jen298CrossRefPubMed
18.
go back to reference Gunnes S, Storaa C, Lind B, Nowak J, Brodin LA: Analysis of the effect of temporal filtering in myocardial tissue velocity imaging. J Am Soc Echocardiogr 2004, 17: 1138-1145. 10.1016/j.echo.2004.06.006CrossRefPubMed Gunnes S, Storaa C, Lind B, Nowak J, Brodin LA: Analysis of the effect of temporal filtering in myocardial tissue velocity imaging. J Am Soc Echocardiogr 2004, 17: 1138-1145. 10.1016/j.echo.2004.06.006CrossRefPubMed
19.
go back to reference Kukulski T, Voigt JU, Wilkenshoff UM, Strotmann JM, Wranne B, Hatle L, Sutherland GR: A comparison of regional myocardial velocity information derived by pulsed and color Doppler techniques: an in vitro and in vivo study. Echocardiography 2000, 17: 639-651. 10.1046/j.1540-8175.2000.00639.xCrossRefPubMed Kukulski T, Voigt JU, Wilkenshoff UM, Strotmann JM, Wranne B, Hatle L, Sutherland GR: A comparison of regional myocardial velocity information derived by pulsed and color Doppler techniques: an in vitro and in vivo study. Echocardiography 2000, 17: 639-651. 10.1046/j.1540-8175.2000.00639.xCrossRefPubMed
20.
go back to reference McCulloch M, Zoghbi WA, Davis R, Thomas C, Dokainish H: Color tissue Doppler myocardial velocities consistently underestimate spectral tissue Doppler velocities: impact on calculation peak transmitral pulsed Doppler velocity/early diastolic tissue Doppler velocity (E/Ea). J Am Soc Echocardiogr 2006, 19: 744-748. 10.1016/j.echo.2006.01.020CrossRefPubMed McCulloch M, Zoghbi WA, Davis R, Thomas C, Dokainish H: Color tissue Doppler myocardial velocities consistently underestimate spectral tissue Doppler velocities: impact on calculation peak transmitral pulsed Doppler velocity/early diastolic tissue Doppler velocity (E/Ea). J Am Soc Echocardiogr 2006, 19: 744-748. 10.1016/j.echo.2006.01.020CrossRefPubMed
21.
go back to reference Lind B, Nowak J, Cain P, Quintana M, Brodin LA: Left ventricular isovolumic velocity and duration variables calculated from colour-coded myocardial velocity images in normal individuals. Eur J Echocardiogr 2004, 5: 284-293. 10.1016/j.euje.2003.11.007CrossRefPubMed Lind B, Nowak J, Cain P, Quintana M, Brodin LA: Left ventricular isovolumic velocity and duration variables calculated from colour-coded myocardial velocity images in normal individuals. Eur J Echocardiogr 2004, 5: 284-293. 10.1016/j.euje.2003.11.007CrossRefPubMed
22.
go back to reference Chen QM, Li W, O'Sullivan C, Francis DP, Gibson D, Henein MY: Clinical in vivo calibration of pulse wave tissue Doppler velocities in the assessment of ventricular wall motion. A comparison study with M-mode echocardiography. Int J Cardiol 2004, 97: 289-295. 10.1016/j.ijcard.2004.03.048CrossRefPubMed Chen QM, Li W, O'Sullivan C, Francis DP, Gibson D, Henein MY: Clinical in vivo calibration of pulse wave tissue Doppler velocities in the assessment of ventricular wall motion. A comparison study with M-mode echocardiography. Int J Cardiol 2004, 97: 289-295. 10.1016/j.ijcard.2004.03.048CrossRefPubMed
23.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed
24.
go back to reference Guo Z, Durand LG, Allard L, Cloutier G, Lee HC, Langlois YE: Cardiac Doppler blood-flow signal analysis. Part 1. Evaluation of the normality and stationarity of the temporal signal. Med Biol Eng Comput 1993, 31: 237-241. 10.1007/BF02458042CrossRefPubMed Guo Z, Durand LG, Allard L, Cloutier G, Lee HC, Langlois YE: Cardiac Doppler blood-flow signal analysis. Part 1. Evaluation of the normality and stationarity of the temporal signal. Med Biol Eng Comput 1993, 31: 237-241. 10.1007/BF02458042CrossRefPubMed
25.
go back to reference Walker A, Olsson E, Wranne B, Ringqvist I, Ask P: Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems. Ultrasound Med Biol 2004, 30: 127-132. 10.1016/j.ultrasmedbio.2003.08.020CrossRefPubMed Walker A, Olsson E, Wranne B, Ringqvist I, Ask P: Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems. Ultrasound Med Biol 2004, 30: 127-132. 10.1016/j.ultrasmedbio.2003.08.020CrossRefPubMed
26.
go back to reference Lind B, Eriksson M, Roumina S, Nowak J, Brodin LA: Longitudinal isovolumic displacement of the left ventricular myocardium assessed by tissue velocity echocardiography in healthy individuals. J Am Soc Echocardiogr 2006, 19: 255-65. 10.1016/j.echo.2005.10.012CrossRefPubMed Lind B, Eriksson M, Roumina S, Nowak J, Brodin LA: Longitudinal isovolumic displacement of the left ventricular myocardium assessed by tissue velocity echocardiography in healthy individuals. J Am Soc Echocardiogr 2006, 19: 255-65. 10.1016/j.echo.2005.10.012CrossRefPubMed
27.
go back to reference Ballo P, Bocelli A, Motto A, Mondillo S: Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects. Eur J Echocardiogr 2008, 9: 748-753. 10.1093/ejechocard/jen130CrossRefPubMed Ballo P, Bocelli A, Motto A, Mondillo S: Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects. Eur J Echocardiogr 2008, 9: 748-753. 10.1093/ejechocard/jen130CrossRefPubMed
28.
go back to reference Gulati VK, Katz WE, Follansbee WP, Gorcsan J 3rd: Mitral annular descent velocity by tissue Doppler echocardiography as an index of global left ventricular function. Am J Cardiol 1996, 77: 979-984. 10.1016/S0002-9149(96)00033-1CrossRefPubMed Gulati VK, Katz WE, Follansbee WP, Gorcsan J 3rd: Mitral annular descent velocity by tissue Doppler echocardiography as an index of global left ventricular function. Am J Cardiol 1996, 77: 979-984. 10.1016/S0002-9149(96)00033-1CrossRefPubMed
29.
go back to reference Nikitin NP, Witte KK, Thackray SD, de Silva R, Clark AL, Cleland JG: Longitudinal ventricular function: normal values of atrioventricular annular and myocardial velocities measured with quantitative two-dimensional color Doppler tissue imaging. J Am Soc Echocardiogr 2003, 16: 906-921. 10.1016/S0894-7317(03)00279-7CrossRefPubMed Nikitin NP, Witte KK, Thackray SD, de Silva R, Clark AL, Cleland JG: Longitudinal ventricular function: normal values of atrioventricular annular and myocardial velocities measured with quantitative two-dimensional color Doppler tissue imaging. J Am Soc Echocardiogr 2003, 16: 906-921. 10.1016/S0894-7317(03)00279-7CrossRefPubMed
30.
go back to reference Yuda S, Inaba Y, Fujii S, Kokubu N, Yoshioka T, Sakurai S, Nishizato K, Fujii N, Hashimoto A, Uno K, Nakata T, Tsuchihashi K, Miura T, Ura N, Natori H, Shimamoto K: Assessment of left ventricular ejection fraction using long-axis systolic function is independent of image quality: a study of tissue Doppler imaging and m-mode echocardiography. Echocardiography 2006, 23: 846-852. 10.1111/j.1540-8175.2006.00331.xCrossRefPubMed Yuda S, Inaba Y, Fujii S, Kokubu N, Yoshioka T, Sakurai S, Nishizato K, Fujii N, Hashimoto A, Uno K, Nakata T, Tsuchihashi K, Miura T, Ura N, Natori H, Shimamoto K: Assessment of left ventricular ejection fraction using long-axis systolic function is independent of image quality: a study of tissue Doppler imaging and m-mode echocardiography. Echocardiography 2006, 23: 846-852. 10.1111/j.1540-8175.2006.00331.xCrossRefPubMed
31.
go back to reference Vinereanu D, Khokhar A, Tweddel AC, Cinteza M, Fraser AG: Estimation of global left ventricular function from the velocity of longitudinal shortening. Echocardiography 2002, 19: 177-185. 10.1046/j.1540-8175.2002.00177.xCrossRefPubMed Vinereanu D, Khokhar A, Tweddel AC, Cinteza M, Fraser AG: Estimation of global left ventricular function from the velocity of longitudinal shortening. Echocardiography 2002, 19: 177-185. 10.1046/j.1540-8175.2002.00177.xCrossRefPubMed
32.
go back to reference Manouras A, Shahgaldi K, Winter R, Brodin LA, Nowak J: Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment? Cardiovasc Ultrasound 2009, 7: 12. 10.1186/1476-7120-7-12CrossRefPubMedPubMedCentral Manouras A, Shahgaldi K, Winter R, Brodin LA, Nowak J: Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment? Cardiovasc Ultrasound 2009, 7: 12. 10.1186/1476-7120-7-12CrossRefPubMedPubMedCentral
Metadata
Title
Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
Authors
Aristomenis Manouras
Arben Shala
Evangelia Nyktari
Kambiz Shahgaldi
Reidar Winter
Panagiotis Vardas
Lars-Åke Brodin
Jacek Nowak
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2009
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-7-29

Other articles of this Issue 1/2009

Cardiovascular Ultrasound 1/2009 Go to the issue