Skip to main content
Top
Published in: Cardiovascular Ultrasound 1/2009

Open Access 01-03-2009 | Research

Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

Authors: Aristomenis Manouras, Kambiz Shahgaldi, Reidar Winter, Lars-Åke Brodin, Jacek Nowak

Published in: Cardiovascular Ultrasound | Issue 1/2009

Login to get access

Abstract

Background

Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis.

Methods

In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 ± 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode.

Results

Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant.

Conclusion

Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.
Appendix
Available only for authorised users
Literature
1.
go back to reference Streeter DD, Spotnitz HM, Patel DP, Ross J, Sonnenblick EH: Fibre orientation in the canine left ventricle during diastole and systole. Circ Res. 1969, 24: 339-47.CrossRefPubMed Streeter DD, Spotnitz HM, Patel DP, Ross J, Sonnenblick EH: Fibre orientation in the canine left ventricle during diastole and systole. Circ Res. 1969, 24: 339-47.CrossRefPubMed
2.
3.
go back to reference Anderson RH, Yen Ho S, Redmann K, Sanchez-Quintana D, Lunkenheimer PP: The anatomical arrengement of the myocardial cells making up the ventricular mass. Eur J Cardiothorac Surg. 2005, 28: 517-25. 10.1016/j.ejcts.2005.06.043CrossRefPubMed Anderson RH, Yen Ho S, Redmann K, Sanchez-Quintana D, Lunkenheimer PP: The anatomical arrengement of the myocardial cells making up the ventricular mass. Eur J Cardiothorac Surg. 2005, 28: 517-25. 10.1016/j.ejcts.2005.06.043CrossRefPubMed
4.
go back to reference Hamilton WF, Rompf JH: Movements of the base of the ventricle and the relative constancy of the cardiac volume. Am J Physiol. 1932, 102: H559-65. Hamilton WF, Rompf JH: Movements of the base of the ventricle and the relative constancy of the cardiac volume. Am J Physiol. 1932, 102: H559-65.
5.
go back to reference Hoffman EA, Ritman EL: Invariant total heart volume in the intact thorax. Am J Physiol. 1985, 249: H883-90.PubMed Hoffman EA, Ritman EL: Invariant total heart volume in the intact thorax. Am J Physiol. 1985, 249: H883-90.PubMed
6.
go back to reference Slager CJ, Hooghoudt TE, Serruys PW, Schuurbiers JC, Reiber JH, Meester GT, Verdouw PD, Hugenholtz PG: Quantitative assessment of regional left ventricular motion using endocardial landmarks. J Am Coll Cardiol. 1986, 7: 317-26.CrossRefPubMed Slager CJ, Hooghoudt TE, Serruys PW, Schuurbiers JC, Reiber JH, Meester GT, Verdouw PD, Hugenholtz PG: Quantitative assessment of regional left ventricular motion using endocardial landmarks. J Am Coll Cardiol. 1986, 7: 317-26.CrossRefPubMed
7.
go back to reference Assmann PE, Slager CJ, Dreysse ST, Borden van der SG, Oomen JA, Roelandt JR: Two-dimensional echocardiographic analysis of the dynamic geometry of the left ventricle: the basis for an improved model of wall motion. J Am Soc Echocardiogr. 1988, 1: 393-405.CrossRefPubMed Assmann PE, Slager CJ, Dreysse ST, Borden van der SG, Oomen JA, Roelandt JR: Two-dimensional echocardiographic analysis of the dynamic geometry of the left ventricle: the basis for an improved model of wall motion. J Am Soc Echocardiogr. 1988, 1: 393-405.CrossRefPubMed
8.
go back to reference Gorman JH, Gupta KB, Streicher JT, Gorman RC, Jackson BM, Ratcliffe MB, Bogen DK, Edmunds LH: Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. J Thorac Cardiovasc Surg. 1996, 112: 712-26. 10.1016/S0022-5223(96)70056-9CrossRefPubMed Gorman JH, Gupta KB, Streicher JT, Gorman RC, Jackson BM, Ratcliffe MB, Bogen DK, Edmunds LH: Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. J Thorac Cardiovasc Surg. 1996, 112: 712-26. 10.1016/S0022-5223(96)70056-9CrossRefPubMed
9.
go back to reference Höglund C, Alam M, Thorstrand C: Atrioventricular valve displacement in healthy persons. An echocardiographic study. Acta Med Scand. 1988, 224: 557-62.CrossRefPubMed Höglund C, Alam M, Thorstrand C: Atrioventricular valve displacement in healthy persons. An echocardiographic study. Acta Med Scand. 1988, 224: 557-62.CrossRefPubMed
10.
go back to reference Simonson JS, Schiller NB: Descent of the base of the left ventricle: An echocardiographic index of the left ventricular function. J Am Soc Echocardiogr. 1989, 2: 25-35.CrossRefPubMed Simonson JS, Schiller NB: Descent of the base of the left ventricle: An echocardiographic index of the left ventricular function. J Am Soc Echocardiogr. 1989, 2: 25-35.CrossRefPubMed
11.
go back to reference Alam M, Rosenhamer G: Atrioventricular plane displacement and left ventricular function. J Am Soc Echocardiogr. 1992, 5: 427-33.CrossRefPubMed Alam M, Rosenhamer G: Atrioventricular plane displacement and left ventricular function. J Am Soc Echocardiogr. 1992, 5: 427-33.CrossRefPubMed
12.
go back to reference Rydberg E, Erhardt L, Brand B, Willenheimer R: Left atrioventricular plane displacement determined by echocardiography: a clinically useful, independent predictor of mortality in patients with stable coronary artery disease. J Intern Med. 2003, 254: 479-85. 10.1046/j.1365-2796.2003.01218.xCrossRefPubMed Rydberg E, Erhardt L, Brand B, Willenheimer R: Left atrioventricular plane displacement determined by echocardiography: a clinically useful, independent predictor of mortality in patients with stable coronary artery disease. J Intern Med. 2003, 254: 479-85. 10.1046/j.1365-2796.2003.01218.xCrossRefPubMed
13.
go back to reference Carlhäll C, Hatle L, Nylander E: A novel method to assess systolic ventricular function using atrioventricular plane displacement – a study in young healthy males and patients with heart disease. Clin Physiol Funct Imaging. 2004, 24: 190-5. 10.1111/j.1475-097X.2004.00547.xCrossRefPubMed Carlhäll C, Hatle L, Nylander E: A novel method to assess systolic ventricular function using atrioventricular plane displacement – a study in young healthy males and patients with heart disease. Clin Physiol Funct Imaging. 2004, 24: 190-5. 10.1111/j.1475-097X.2004.00547.xCrossRefPubMed
14.
go back to reference Mele D, Pedini I, Alboni P, Levine RA: Anatomic M-mode: a new technique for quantitative assessment of left ventricular size and function. Am J Cardiol. 1998, 81: 82G-85G. 10.1016/S0002-9149(98)00060-5CrossRefPubMed Mele D, Pedini I, Alboni P, Levine RA: Anatomic M-mode: a new technique for quantitative assessment of left ventricular size and function. Am J Cardiol. 1998, 81: 82G-85G. 10.1016/S0002-9149(98)00060-5CrossRefPubMed
15.
go back to reference Strotmann JM, Kvitting J-PE, Wilkenshoff UM, Wranne B, Hatle L, Sutherland GR: Anatomic M-mode echocardiography: a new approch to assess regional myocardial function – a comparative in vivo and in vitro study of both fundamental and second harmonic imaging modes. J Am Soc Echocardiogr. 1999, 12: 300-7. 10.1016/S0894-7317(99)70050-7CrossRefPubMed Strotmann JM, Kvitting J-PE, Wilkenshoff UM, Wranne B, Hatle L, Sutherland GR: Anatomic M-mode echocardiography: a new approch to assess regional myocardial function – a comparative in vivo and in vitro study of both fundamental and second harmonic imaging modes. J Am Soc Echocardiogr. 1999, 12: 300-7. 10.1016/S0894-7317(99)70050-7CrossRefPubMed
16.
go back to reference Isaaz K, Thompson A, Ethevenot G, Cloez B, Brembilla JL, Pernot C: Doppler echocardiographic measurement of low velocity motion of left ventricular posterior wall. Am J Cardiol. 1989, 64: 66-75. 10.1016/0002-9149(89)90655-3CrossRefPubMed Isaaz K, Thompson A, Ethevenot G, Cloez B, Brembilla JL, Pernot C: Doppler echocardiographic measurement of low velocity motion of left ventricular posterior wall. Am J Cardiol. 1989, 64: 66-75. 10.1016/0002-9149(89)90655-3CrossRefPubMed
17.
go back to reference McDicken WN, Sutherland GR, Moran CM, Gordon LN: Colour Doppler velocity imaging of the myocardium. Ultrasound Med Biol. 1992, 18: 651-4. 10.1016/0301-5629(92)90080-TCrossRefPubMed McDicken WN, Sutherland GR, Moran CM, Gordon LN: Colour Doppler velocity imaging of the myocardium. Ultrasound Med Biol. 1992, 18: 651-4. 10.1016/0301-5629(92)90080-TCrossRefPubMed
18.
go back to reference Sutherland GR, Stewart MJ, Groundstroem KW, Moran CM, Fleming A, Guell-Peris FJ, Riemersma RA, Fenn LN, Fox KA, McDicken WN: Colour Doppler myocardial imaging: a new technique for the assessment of myocardial function. J Am Soc Echocardiogr. 1994, 7: 441-58.CrossRefPubMed Sutherland GR, Stewart MJ, Groundstroem KW, Moran CM, Fleming A, Guell-Peris FJ, Riemersma RA, Fenn LN, Fox KA, McDicken WN: Colour Doppler myocardial imaging: a new technique for the assessment of myocardial function. J Am Soc Echocardiogr. 1994, 7: 441-58.CrossRefPubMed
19.
go back to reference Kukulski T, Voigt JU, Wilkenshoff UM, Strotmann JM, Wranne B, Hatle L, Sutherland GR: A comparison of regional myocardial velocity information derived by pulsed and color Doppler techniques: An in vitro and in vivo study. Echocardiography. 2000, 17: 639-51. 10.1046/j.1540-8175.2000.00639.xCrossRefPubMed Kukulski T, Voigt JU, Wilkenshoff UM, Strotmann JM, Wranne B, Hatle L, Sutherland GR: A comparison of regional myocardial velocity information derived by pulsed and color Doppler techniques: An in vitro and in vivo study. Echocardiography. 2000, 17: 639-51. 10.1046/j.1540-8175.2000.00639.xCrossRefPubMed
20.
go back to reference McCulloch M, Zoghbi WA, Davis R, Thomas C, Dokainish H: Color tissue Doppler myocardial velocities consistently underestimate spectral tissue Doppler velocities: impact on calculation peak transmitral pulsed Doppler velocity/early diastolic tisssue Doppler velcity (E/Ea). J Am Soc Echocardiogr. 2006, 19: 744-8. 10.1016/j.echo.2006.01.020CrossRefPubMed McCulloch M, Zoghbi WA, Davis R, Thomas C, Dokainish H: Color tissue Doppler myocardial velocities consistently underestimate spectral tissue Doppler velocities: impact on calculation peak transmitral pulsed Doppler velocity/early diastolic tisssue Doppler velcity (E/Ea). J Am Soc Echocardiogr. 2006, 19: 744-8. 10.1016/j.echo.2006.01.020CrossRefPubMed
21.
go back to reference Mondillo S, Galderisi M, Ballo P, Marino PN, : Left ventricular systolic longitudinal function: comparison among simple M-mode, pulsed, and M-mode color tissue Doppler of mitral annulus in healthy individuals. J Am Soc Echocardiogr. 2006, 19: 1085-91. 10.1016/j.echo.2006.04.005CrossRefPubMed Mondillo S, Galderisi M, Ballo P, Marino PN, : Left ventricular systolic longitudinal function: comparison among simple M-mode, pulsed, and M-mode color tissue Doppler of mitral annulus in healthy individuals. J Am Soc Echocardiogr. 2006, 19: 1085-91. 10.1016/j.echo.2006.04.005CrossRefPubMed
22.
go back to reference Ballo P, Bocelli A, Motto A, Mondillo S: Concordance between M-mode, pulsed tissue Doppler and colour tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects. Eur J Echocardiography. 2008, 9: 748-53. 10.1093/ejechocard/jen130.CrossRef Ballo P, Bocelli A, Motto A, Mondillo S: Concordance between M-mode, pulsed tissue Doppler and colour tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects. Eur J Echocardiography. 2008, 9: 748-53. 10.1093/ejechocard/jen130.CrossRef
23.
go back to reference Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005, 18: 1440-63. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005, 18: 1440-63.
24.
go back to reference Lind B, Nowak J, Cain P, Quintana M, Brodin L-Å: Left ventricular isovolumic velocity and duration variables calculated from colour-coded myocardial velocity images in normal individuals. Eur J Echocardiography. 2004, 5: 284-93. 10.1016/j.euje.2003.11.007.CrossRef Lind B, Nowak J, Cain P, Quintana M, Brodin L-Å: Left ventricular isovolumic velocity and duration variables calculated from colour-coded myocardial velocity images in normal individuals. Eur J Echocardiography. 2004, 5: 284-93. 10.1016/j.euje.2003.11.007.CrossRef
25.
go back to reference Altman DG, Bland JM: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 307-310.PubMed Altman DG, Bland JM: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 307-310.PubMed
26.
go back to reference Strotmann JM, Hatle L, Sutherland GR: Doppler myocardial imaging in the assessment of normal and ischemic myocardial function – past, present and future. Int J Cardiovasc Imaging. 2001, 17: 89-98. 10.1023/A:1010679522539CrossRefPubMed Strotmann JM, Hatle L, Sutherland GR: Doppler myocardial imaging in the assessment of normal and ischemic myocardial function – past, present and future. Int J Cardiovasc Imaging. 2001, 17: 89-98. 10.1023/A:1010679522539CrossRefPubMed
27.
go back to reference Guth B, Savage R, White F, Hagan A, Samotoy L, Bloor C: Detection of ischemic wall dysfunction: comparison between M-mode echocardiography and sonomicrometry. Am Heart J. 1984, 107: 449-57. 10.1016/0002-8703(84)90085-1CrossRefPubMed Guth B, Savage R, White F, Hagan A, Samotoy L, Bloor C: Detection of ischemic wall dysfunction: comparison between M-mode echocardiography and sonomicrometry. Am Heart J. 1984, 107: 449-57. 10.1016/0002-8703(84)90085-1CrossRefPubMed
28.
go back to reference Yumi Hayashi S, Lind BI, Seeberger A, Mazza do Nascimento M, Lindholm BJ, Brodin L-Å: Analysis of mitral annulus motion measurements derived from M-mode, amatomic M-mode, tissue Dopppler displacement, and 2-dimensional strain imaging. J Am Soc Echocradiogr. 2006, 19: 1092-101. 10.1016/j.echo.2006.04.014.CrossRef Yumi Hayashi S, Lind BI, Seeberger A, Mazza do Nascimento M, Lindholm BJ, Brodin L-Å: Analysis of mitral annulus motion measurements derived from M-mode, amatomic M-mode, tissue Dopppler displacement, and 2-dimensional strain imaging. J Am Soc Echocradiogr. 2006, 19: 1092-101. 10.1016/j.echo.2006.04.014.CrossRef
29.
go back to reference Vinereanu D, Khokhar A, Fraser AG: Reproducibility of pulsed wave tissue Doppler echocardiography. Am J Soc Echocardiogr. 1999, 12: 492-9. 10.1016/S0894-7317(99)70086-6.CrossRef Vinereanu D, Khokhar A, Fraser AG: Reproducibility of pulsed wave tissue Doppler echocardiography. Am J Soc Echocardiogr. 1999, 12: 492-9. 10.1016/S0894-7317(99)70086-6.CrossRef
30.
go back to reference Lui EY, Steinman AH, Cobbold RS, Johnston KW: Human factors as a source of error in peak Doppler velocity measurement. J Vasc Surg. 2005, 42: 972-9. 10.1016/j.jvs.2005.07.014CrossRefPubMed Lui EY, Steinman AH, Cobbold RS, Johnston KW: Human factors as a source of error in peak Doppler velocity measurement. J Vasc Surg. 2005, 42: 972-9. 10.1016/j.jvs.2005.07.014CrossRefPubMed
31.
go back to reference Sutherland GR, Bijnens B, McDicken WN: Tissue Doppler echocardiography: Historical perspective and technological considerations. Echocardiography. 1999, 16: 445-53. 10.1111/j.1540-8175.1999.tb00091.xCrossRefPubMed Sutherland GR, Bijnens B, McDicken WN: Tissue Doppler echocardiography: Historical perspective and technological considerations. Echocardiography. 1999, 16: 445-53. 10.1111/j.1540-8175.1999.tb00091.xCrossRefPubMed
32.
go back to reference Cain P, Baglin T, Case C, Spicer D, Short L, Marwick TH: Application of tissue Doppler to interpretation of dobutamine echocardiography and comparison with quantitative coronary angiography. Am J Cardiol. 2001, 87: 525-31. 10.1016/S0002-9149(00)01425-9CrossRefPubMed Cain P, Baglin T, Case C, Spicer D, Short L, Marwick TH: Application of tissue Doppler to interpretation of dobutamine echocardiography and comparison with quantitative coronary angiography. Am J Cardiol. 2001, 87: 525-31. 10.1016/S0002-9149(00)01425-9CrossRefPubMed
33.
go back to reference Mädler CF, Payne N, Wilkenshoff U, Cohen A, Derumeaux GA, Piérard LA, Engvall J, Brodin L-Å, Sutherlamd GR, Frazer AG: Non-invasive diagnosis of coronary artery disease by quantitative stress echocardiography: optimal diagnostic models using off-line tissue Doppler in the MYDISE study. Eur Heart J. 2003, 24: 1584-94. 10.1016/S0195-668X(03)00099-XCrossRefPubMed Mädler CF, Payne N, Wilkenshoff U, Cohen A, Derumeaux GA, Piérard LA, Engvall J, Brodin L-Å, Sutherlamd GR, Frazer AG: Non-invasive diagnosis of coronary artery disease by quantitative stress echocardiography: optimal diagnostic models using off-line tissue Doppler in the MYDISE study. Eur Heart J. 2003, 24: 1584-94. 10.1016/S0195-668X(03)00099-XCrossRefPubMed
Metadata
Title
Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?
Authors
Aristomenis Manouras
Kambiz Shahgaldi
Reidar Winter
Lars-Åke Brodin
Jacek Nowak
Publication date
01-03-2009
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2009
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-7-12

Other articles of this Issue 1/2009

Cardiovascular Ultrasound 1/2009 Go to the issue