01-08-2016 | Debate Article

Traditional gamma cameras are preferred

Author: E. Gordon DePuey, MD

Published in: Journal of Nuclear Cardiology | Issue 4/2016

Login to get access

Abstract

Although the new solid-state dedicated cardiac cameras provide excellent spatial and energy resolution and allow for markedly reduced SPECT acquisition times and/or injected radiopharmaceutical activity, they have some distinct disadvantages compared to traditional sodium iodide SPECT cameras. They are expensive. Attenuation correction is not available. Cardio-focused collimation, advantageous to increase depth-dependent resolution and myocardial count density, accentuates diaphragmatic attenuation and scatter from subdiaphragmatic structures. Although supplemental prone imaging is therefore routinely advised, many patients cannot tolerate it. Moreover, very large patients cannot be accommodated in the solid-state camera gantries. Since data are acquired simultaneously with an arc of solid-state detectors around the chest, no temporally dependent “rotating” projection images are obtained. Therefore, patient motion can be neither detected nor corrected. In contrast, traditional sodium iodide SPECT cameras provide rotating projection images to allow technologists and physicians to detect and correct patient motion and to accurately detect the position of soft tissue attenuators and to anticipate associated artifacts. Very large patients are easily accommodated. Low-dose x-ray attenuation correction is widely available. Also, relatively inexpensive low-count density software is provided by many vendors, allowing shorter SPECT acquisition times and reduced injected activity approaching that achievable with solid-state cameras.
Literature
1.
go back to reference DePuey EG. New software methods to cope with reduced counting statistics: Shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol 2009;16:335-8.CrossRefPubMed DePuey EG. New software methods to cope with reduced counting statistics: Shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol 2009;16:335-8.CrossRefPubMed
2.
go back to reference DePuey EG, Ata P, Wray R, Friedman M. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing. J Nucl Cardiol 2012;19:931-44.CrossRefPubMed DePuey EG, Ata P, Wray R, Friedman M. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing. J Nucl Cardiol 2012;19:931-44.CrossRefPubMed
3.
go back to reference Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed
4.
go back to reference DePuey EG. Image artifacts. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77. DePuey EG. Image artifacts. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77.
5.
go back to reference Agrawal V, DePuey EG. Myocardial perfusion SPECT horizontal motion artifact. J Nucl Cardiol 2014;21:1260-5.CrossRef Agrawal V, DePuey EG. Myocardial perfusion SPECT horizontal motion artifact. J Nucl Cardiol 2014;21:1260-5.CrossRef
6.
go back to reference Esteves FP, Galt JR. SPECT attenuation correction. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77. Esteves FP, Galt JR. SPECT attenuation correction. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77.
7.
go back to reference Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT. J Nucl Med 2010;4:733. Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT. J Nucl Med 2010;4:733.
8.
go back to reference Armstrong I, Saint K, Tonge C, Arumugam P. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study. J Nucl Cardiol 2016. doi:10.1007/s12350-015-0368-0.PubMed Armstrong I, Saint K, Tonge C, Arumugam P. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study. J Nucl Cardiol 2016. doi:10.​1007/​s12350-015-0368-0.PubMed
Metadata
Title
Traditional gamma cameras are preferred
Author
E. Gordon DePuey, MD
Publication date
01-08-2016
Publisher
Springer US
Published in
Journal of Nuclear Cardiology / Issue 4/2016
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0460-0

Other articles of this Issue 4/2016

Journal of Nuclear Cardiology 4/2016 Go to the issue