Skip to main content
Top
Published in: Journal of Nuclear Cardiology 3/2014

01-06-2014 | Original Article

Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera

Authors: Simona Ben-Haim, MD, DSc, Omar Almukhailed, MD, Johanne Neill, MD, Piotr Slomka, PhD, Rayjanah Allie, BSc, Dalia Shiti, BSc, Daniel S. Berman, MD, FACC, Jamshed Bomanji, MBBS, MSc, PhD

Published in: Journal of Nuclear Cardiology | Issue 3/2014

Login to get access

Abstract

Purpose

We have assessed whether additional upright imaging increases the confidence of interpretation of stress only supine myocardial perfusion imaging (MPI) in obese patients.

Methods and results

Tc-MIBI stress MPI of 101 consecutive patients (M = 49, 62 ± 12 years) with BMI ≥30 scanned on the D-SPECT cardiac camera were assessed. Images were interpreted as diagnostic or equivocal and the need for a rest study was recorded. Stress supine MPI was interpreted first, then gated and finally upright data were added. Defects on supine but not on upright were defined as artefacts and defects seen on both as abnormal. The total perfusion deficit (TPD) was also quantified. There were 27 normal, 22 abnormal, and 52 equivocal supine scans. The median EF was 52%, unaffecting the need for rest imaging. Upright imaging reclassified 32/52 (62%) equivocal studies as normal and 6/52 (11%) as abnormal (P < 0.001). Rest scan was deemed needed in 74/101 patients on supine vs 42/101 on supine/upright (P < 0.001). Supine TPD was normal in 53 and supine/upright TPD was normal in 70 patients (P < 0.001).

Conclusion

Supine stress MPI is inadequate in obese patients. The addition of upright imaging significantly increases the ability to interpret scans as diagnostic and may reduce considerably the need for rest imaging.
Literature
1.
go back to reference Kim C, Kwok YS, Heagerty P, Redberg R. Pharmacologic stress testing for coronary disease diagnosis: a meta-analysis. Am Heart J 2001;142:934-44.PubMedCrossRef Kim C, Kwok YS, Heagerty P, Redberg R. Pharmacologic stress testing for coronary disease diagnosis: a meta-analysis. Am Heart J 2001;142:934-44.PubMedCrossRef
2.
go back to reference Singh B, Bateman TM, Case JA, Heller G. Attenuation artefact, attenuation correction and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.PubMedCrossRef Singh B, Bateman TM, Case JA, Heller G. Attenuation artefact, attenuation correction and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.PubMedCrossRef
3.
go back to reference DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artefact. J Nucl Med 1995;36:952-5.PubMed DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artefact. J Nucl Med 1995;36:952-5.PubMed
4.
go back to reference Kiat H, Van Train KF, Friedman JD, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed Kiat H, Van Train KF, Friedman JD, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed
5.
go back to reference Hayes SW, De Lorenzo A, Hachamovitch R, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed Hayes SW, De Lorenzo A, Hachamovitch R, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed
6.
go back to reference Ficaro EP, Fessler JA, Shreve PD, et al. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission tomography. Circulation 1996;93:463-73.PubMedCrossRef Ficaro EP, Fessler JA, Shreve PD, et al. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission tomography. Circulation 1996;93:463-73.PubMedCrossRef
7.
go back to reference Vidal R, Buvat I, Darcourt J, et al. Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images. J Nucl Med 1999;40:1301-9.PubMed Vidal R, Buvat I, Darcourt J, et al. Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images. J Nucl Med 1999;40:1301-9.PubMed
8.
go back to reference Hendel RC, Corbett JR, Cullom SJ, et al. The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and Society of Nuclear Medicine. J Nucl Cardiol 2002;9:135-43.PubMedCrossRef Hendel RC, Corbett JR, Cullom SJ, et al. The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and Society of Nuclear Medicine. J Nucl Cardiol 2002;9:135-43.PubMedCrossRef
9.
go back to reference Heller GV, Bateman TM, Johnson LL, et al. Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging. J Nucl Cardiol 2004;11:273-81.PubMedCrossRef Heller GV, Bateman TM, Johnson LL, et al. Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging. J Nucl Cardiol 2004;11:273-81.PubMedCrossRef
10.
go back to reference Mathur S, Heller GV, Bateman TM, et al. Clinical value of stress-only Tc-99m SPECT imaging: importance of attenuation correction. J Nucl Cardiol 2013;20:27-37.PubMedCrossRef Mathur S, Heller GV, Bateman TM, et al. Clinical value of stress-only Tc-99m SPECT imaging: importance of attenuation correction. J Nucl Cardiol 2013;20:27-37.PubMedCrossRef
11.
go back to reference Gibson PB, Demus D, Noto R, et al. Lowe vent rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.PubMedCrossRef Gibson PB, Demus D, Noto R, et al. Lowe vent rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.PubMedCrossRef
12.
go back to reference Gemignani AS, Muhlebach SG, Abbott BG, Roye GD, Harrington DT, Arrighi JA. Stress-only or stress/rest myocardial perfusion imaging in patients undergoing evaluation for bariatric surgery. J Nucl Cardiol 2011;18:886-92.PubMedCrossRef Gemignani AS, Muhlebach SG, Abbott BG, Roye GD, Harrington DT, Arrighi JA. Stress-only or stress/rest myocardial perfusion imaging in patients undergoing evaluation for bariatric surgery. J Nucl Cardiol 2011;18:886-92.PubMedCrossRef
13.
go back to reference Duvall WL, Baber U, Levine EJ, Croft LB, Henzlova MJ. A model for the prediction of a successful stress-first Tc-99m SPECT MPI. J Nucl Cardiol 2012;19:1124-34.PubMedCrossRef Duvall WL, Baber U, Levine EJ, Croft LB, Henzlova MJ. A model for the prediction of a successful stress-first Tc-99m SPECT MPI. J Nucl Cardiol 2012;19:1124-34.PubMedCrossRef
14.
go back to reference Nakazato R, Tamarappoo BK, Kang X, et al. Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography. J Nucl Med 2010;51:1724-31.PubMedCentralPubMedCrossRef Nakazato R, Tamarappoo BK, Kang X, et al. Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography. J Nucl Med 2010;51:1724-31.PubMedCentralPubMedCrossRef
15.
go back to reference Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.PubMedCrossRef Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.PubMedCrossRef
16.
go back to reference Gambhir SS, Berman DS, Ziffer J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.PubMedCrossRef Gambhir SS, Berman DS, Ziffer J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.PubMedCrossRef
17.
go back to reference Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.PubMedCrossRef Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.PubMedCrossRef
18.
go back to reference Slomka PJ, Nishina H, Berman DS, et al. Automated quantification of myocardial perfusion SPECT using simplified normal limits. J Nucl Cardiol 2005;12:66-77.PubMedCrossRef Slomka PJ, Nishina H, Berman DS, et al. Automated quantification of myocardial perfusion SPECT using simplified normal limits. J Nucl Cardiol 2005;12:66-77.PubMedCrossRef
19.
go back to reference Xu Y, Fish M, Gerlach J, et al. Combined quantitative analysis of attenuation corrected and non-corrected myocardial perfusion SPECT: method development and clinical validation. J Nucl Cardiol 2010;17:591-9.PubMedCentralPubMedCrossRef Xu Y, Fish M, Gerlach J, et al. Combined quantitative analysis of attenuation corrected and non-corrected myocardial perfusion SPECT: method development and clinical validation. J Nucl Cardiol 2010;17:591-9.PubMedCentralPubMedCrossRef
20.
go back to reference Bhavanni SP, Heller GV. Stress-only myocardial perfusion imaging … it IS time for a change! J Nucl Cardiol 2011;18:836-9.CrossRef Bhavanni SP, Heller GV. Stress-only myocardial perfusion imaging … it IS time for a change! J Nucl Cardiol 2011;18:836-9.CrossRef
21.
go back to reference Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol 1997;29:69-77.PubMedCrossRef Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol 1997;29:69-77.PubMedCrossRef
22.
go back to reference Berman DS, Kang X, Tamarappoo B, et al. Stress thallium 201/rest technetium 99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.PubMedCrossRef Berman DS, Kang X, Tamarappoo B, et al. Stress thallium 201/rest technetium 99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.PubMedCrossRef
23.
go back to reference Chang SM, Nabi F, Xu Y, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging: similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2009;55:221-30.PubMedCrossRef Chang SM, Nabi F, Xu Y, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging: similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2009;55:221-30.PubMedCrossRef
24.
go back to reference Duvall WL, Wijetunga MN, Klein TM, et al. The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study. J Nucl Cardiol 2010;17:370-7.PubMedCrossRef Duvall WL, Wijetunga MN, Klein TM, et al. The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study. J Nucl Cardiol 2010;17:370-7.PubMedCrossRef
25.
go back to reference Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, MArzullo P. Evaluation os ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 2012;39:1254-61.PubMedCrossRef Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, MArzullo P. Evaluation os ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 2012;39:1254-61.PubMedCrossRef
Metadata
Title
Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
Authors
Simona Ben-Haim, MD, DSc
Omar Almukhailed, MD
Johanne Neill, MD
Piotr Slomka, PhD
Rayjanah Allie, BSc
Dalia Shiti, BSc
Daniel S. Berman, MD, FACC
Jamshed Bomanji, MBBS, MSc, PhD
Publication date
01-06-2014
Publisher
Springer US
Published in
Journal of Nuclear Cardiology / Issue 3/2014
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-014-9853-0

Other articles of this Issue 3/2014

Journal of Nuclear Cardiology 3/2014 Go to the issue

CME ARTICLE REVIEW ARTICLE

Endocarditis and molecular imaging