Skip to main content
Top
Published in: Journal of Nuclear Cardiology 3/2010

01-06-2010 | Original Article

The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study

Authors: W. Lane Duvall, MD, Melanie N. Wijetunga, MD, Thomas M. Klein, MD, Louai Razzouk, MD, Jim Godbold, PhD, Lori B. Croft, MD, Milena J. Henzlova, MD

Published in: Journal of Nuclear Cardiology | Issue 3/2010

Login to get access

Abstract

Background

Stress-only imaging saves time and radiation exposure, but apprehension remains about the reliability, diagnostic, and prognostic accuracy of a normal stress-only study. The objective of this study was to determine the prognosis of stress-only SPECT MPI in routine clinical practice.

Methods

Patients at lower pre-test risk for CAD presenting for a Tc-99m SPECT MPI over a 2-year period underwent a stress-only protocol. If the stress images were normal (attenuation correction was routinely acquired on all patients), rest imaging was not done. Outcomes of the stress-only group were compared to a full rest-stress protocol cohort. Only patients with normal perfusion and left ventricular function, and no known CAD, were included. All-cause mortality was determined using the Social Security Death Index and specific causes of death were determined using the National Death Index. The difference in all-cause and cardiac mortality between groups in the presence of competing risks was assessed using log-normal survival models.

Results

Out of 10,609 patients studied during the time period, 1,673 had a normal stress-only study and 3,237 had a normal rest-stress study. At one year, there were 20 total and 3 cardiac deaths (1.2% and 0.2% mortality) in the stress-only group, and 40 total and 4 cardiac deaths (1.2% and 0.1% mortality) in the rest-stress cohort. At the end of follow-up (40 ± 9 months), there were 46 total and 7 cardiac deaths (2.7% and 0.4% mortality) in the stress-only group, and 119 total and 17 cardiac deaths (3.7% and 0.5% mortality) in the rest-stress cohort. No significant difference between the stress-only and rest-stress cohorts was found after controlling for confounding variables for both all-cause mortality (p = .94) and cardiac mortality (p = .82).

Conclusions

A normal stress-only MPI has an excellent short-term prognosis (both for all-cause and cardiac mortality) comparable to that of a normal rest-stress MPI study.
Literature
1.
go back to reference Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed
2.
go back to reference Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 2007;298:317-23.CrossRefPubMed Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 2007;298:317-23.CrossRefPubMed
3.
go back to reference Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.CrossRefPubMed Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.CrossRefPubMed
4.
go back to reference Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;1:113-22.CrossRefPubMed Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;1:113-22.CrossRefPubMed
5.
go back to reference Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 1984;8:306-16.PubMed Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 1984;8:306-16.PubMed
6.
go back to reference Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994;13:601-9.CrossRefPubMed Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994;13:601-9.CrossRefPubMed
7.
go back to reference Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.CrossRefPubMed Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.CrossRefPubMed
8.
go back to reference Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation 2007;116:1290-305.CrossRefPubMed Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation 2007;116:1290-305.CrossRefPubMed
9.
go back to reference Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, et al. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1995;26:639-47.CrossRefPubMed Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, et al. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1995;26:639-47.CrossRefPubMed
10.
go back to reference Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico JA, Friedman J, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification. Circulation 1996;93:905-14.PubMed Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico JA, Friedman J, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification. Circulation 1996;93:905-14.PubMed
11.
go back to reference Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed
12.
go back to reference Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation 2003;107:2900-7.CrossRefPubMed Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation 2003;107:2900-7.CrossRefPubMed
13.
go back to reference Brown KA, Altland E, Rowen M. Prognostic value of normal technetium-99m-sestamibi cardiac imaging. J Nucl Med 1994;35:554-7.PubMed Brown KA, Altland E, Rowen M. Prognostic value of normal technetium-99m-sestamibi cardiac imaging. J Nucl Med 1994;35:554-7.PubMed
14.
go back to reference Iskander S, Iskandrian AE. Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging. J Am Coll Cardiol 1998;32:57-62.CrossRefPubMed Iskander S, Iskandrian AE. Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging. J Am Coll Cardiol 1998;32:57-62.CrossRefPubMed
15.
go back to reference Singh B, Bateman TM, Case JA, Heller G. Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.CrossRefPubMed Singh B, Bateman TM, Case JA, Heller G. Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.CrossRefPubMed
16.
go back to reference Gibson PB, Demus D, Noto R, Hudson W, Johnson LL. Low event rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.CrossRefPubMed Gibson PB, Demus D, Noto R, Hudson W, Johnson LL. Low event rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.CrossRefPubMed
17.
go back to reference Duvall WL, Wijetunga M, Klein T, Hingorani R, Henzlova M. The prognosis of normal stress-only SPECT myocardial perfusion imaging studies (abstr). J Am Coll Cardiol 2009;53:287A. Duvall WL, Wijetunga M, Klein T, Hingorani R, Henzlova M. The prognosis of normal stress-only SPECT myocardial perfusion imaging studies (abstr). J Am Coll Cardiol 2009;53:287A.
18.
go back to reference Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed
19.
go back to reference Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke CD, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:e97-120.CrossRefPubMed Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke CD, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:e97-120.CrossRefPubMed
20.
go back to reference Schisterman EF, Whitcomb BW. Use of the Social Security Administration Death Master File for ascertainment of mortality status. Popul Health Metr 2004;2:2.CrossRefPubMed Schisterman EF, Whitcomb BW. Use of the Social Security Administration Death Master File for ascertainment of mortality status. Popul Health Metr 2004;2:2.CrossRefPubMed
21.
go back to reference Williams BC, Demitrack LB, Fries BE. The accuracy of the National Death Index when personal identifiers other than Social Security number are used. Am J Public Health 1992;82:1145-7.CrossRefPubMed Williams BC, Demitrack LB, Fries BE. The accuracy of the National Death Index when personal identifiers other than Social Security number are used. Am J Public Health 1992;82:1145-7.CrossRefPubMed
22.
go back to reference Miller TD, Roger VL, Hodge DO, Gibbons RJ. A simple clinical score accurately predicts outcome in a community-based population undergoing stress testing. Am J Med 2005;118:866-72.CrossRefPubMed Miller TD, Roger VL, Hodge DO, Gibbons RJ. A simple clinical score accurately predicts outcome in a community-based population undergoing stress testing. Am J Med 2005;118:866-72.CrossRefPubMed
23.
go back to reference Henzlova MJ, Cerqueira MD, Hansen CL, Taillefer R, Yao SS. ASNC announcement. J Nucl Cardiol 2009;16:331.CrossRef Henzlova MJ, Cerqueira MD, Hansen CL, Taillefer R, Yao SS. ASNC announcement. J Nucl Cardiol 2009;16:331.CrossRef
24.
go back to reference Lavalaye JM, Schroeder-Tanka JM, Tiel-van Buul MM, van der Wall EE, Lie KI, van Royen EA. Implementation of technetium-99m MIBI SPECT imaging guidelines: Optimizing the two day stress-rest protocol. Int J Card Imaging 1997;13:331-5.CrossRefPubMed Lavalaye JM, Schroeder-Tanka JM, Tiel-van Buul MM, van der Wall EE, Lie KI, van Royen EA. Implementation of technetium-99m MIBI SPECT imaging guidelines: Optimizing the two day stress-rest protocol. Int J Card Imaging 1997;13:331-5.CrossRefPubMed
25.
go back to reference Heller GV, Bateman TM, Johnson LL, Cullom SJ, Case JA, Galt JR, et al. Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging. J Nucl Cardiol 2004;11:273-81.CrossRefPubMed Heller GV, Bateman TM, Johnson LL, Cullom SJ, Case JA, Galt JR, et al. Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging. J Nucl Cardiol 2004;11:273-81.CrossRefPubMed
26.
go back to reference Garcia EV. SPECT attenuation correction: An essential tool to realize nuclear cardiology’s manifest destiny. J Nucl Cardiol 2007;14:16-24.CrossRefPubMed Garcia EV. SPECT attenuation correction: An essential tool to realize nuclear cardiology’s manifest destiny. J Nucl Cardiol 2007;14:16-24.CrossRefPubMed
27.
go back to reference Goldstein J. Coronary computed tomography for systemic triage of acute chest pain patients to treatment. American Heart Association Scientific Sessions. Orlando, Fl; 2009. Goldstein J. Coronary computed tomography for systemic triage of acute chest pain patients to treatment. American Heart Association Scientific Sessions. Orlando, Fl; 2009.
28.
go back to reference Ward RP, Al-Mallah MH, Grossman GB, Hansen CL, Hendel RC, Kerwin TC, et al. American Society of Nuclear Cardiology review of the ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). J Nucl Cardiol 2007;14:e26-38.CrossRefPubMed Ward RP, Al-Mallah MH, Grossman GB, Hansen CL, Hendel RC, Kerwin TC, et al. American Society of Nuclear Cardiology review of the ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). J Nucl Cardiol 2007;14:e26-38.CrossRefPubMed
Metadata
Title
The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study
Authors
W. Lane Duvall, MD
Melanie N. Wijetunga, MD
Thomas M. Klein, MD
Louai Razzouk, MD
Jim Godbold, PhD
Lori B. Croft, MD
Milena J. Henzlova, MD
Publication date
01-06-2010
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue 3/2010
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-010-9210-x

Other articles of this Issue 3/2010

Journal of Nuclear Cardiology 3/2010 Go to the issue

JOURNAL OF NUCLEAR CARDIOLOGY NEWS UPDATE

Radiation Reduction: How Low Can YOU go?