Abstract

Aim

Purpose of this study was to assess the impact of mediastinal region of interest (ROI) definition on intra- and inter-observer variability in relation to collimator type.

Methods

Thirty-five subjects with CHF (80% men, mean age 66 ± 9 years, NYHA 2.4 ± 0.5, LVEF 29 ± 8.4%) were enrolled. 15 minutes and 4 hours post-injection (p.i.) of 123I-MIBG, planar images were sequentially acquired with low energy high energy (LEHR) and medium energy (ME) collimators. In the first analysis, observer-defined mediastinal ROI was used. In the second analysis, a predefined mediastinal ROI was used. Intra- and inter-observer variability of late H/M was assessed using Lin’s concordance coefficient (LCC).

Results

There was substantial agreement between all three observers using predefined mediastinum ROI. LCCs for LEHR were 0.98, 0.96, and 0.95, for ME 0.98, 0.97, and 0.97. However, observer-defined mediastinal ROI resulted in poor-moderate agreement. LCCs for LEHR were 0.82, 0.94, and 0.70, for ME 0.77, 0.91, and 0.80. Intra-observer analysis using predefined mediastinal ROI showed substantial agreement. LCC was 0.97 for LEHR and 0.96 for ME.

Conclusion

Predefined mediastinal ROI results in low intra- and inter-observer variability of late H/M and is, therefore, to be preferred over observer-defined mediastinal ROI. Intra- and inter-observer variability of late H/M is not influenced by collimator choice.
Literature
1.
go back to reference Carrio I. Cardiac neurotransmission imaging. J Nucl Med 2001;42:1062-76.PubMed Carrio I. Cardiac neurotransmission imaging. J Nucl Med 2001;42:1062-76.PubMed
2.
go back to reference Caldwell JH, Link JM, Levy WC, Poole JE, Stratton JR. Evidence for pre- to postsynaptic mismatch of the cardiac sympathetic nervous system in ischemic congestive heart failure. J Nucl Med 2008;49:234-41.PubMedCrossRef Caldwell JH, Link JM, Levy WC, Poole JE, Stratton JR. Evidence for pre- to postsynaptic mismatch of the cardiac sympathetic nervous system in ischemic congestive heart failure. J Nucl Med 2008;49:234-41.PubMedCrossRef
3.
go back to reference Kline RC, Swanson DP, Wieland DM, Thrall JH, Gross MD, Pitt B, et al. Myocardial imaging in man with I-123 meta-iodobenzylguanidine. J Nucl Med 1981;22:129-32.PubMed Kline RC, Swanson DP, Wieland DM, Thrall JH, Gross MD, Pitt B, et al. Myocardial imaging in man with I-123 meta-iodobenzylguanidine. J Nucl Med 1981;22:129-32.PubMed
5.
go back to reference Paul M, Schafers M, Kies P, Acil T, Schafers K, Breithardt G, et al. Impact of sympathetic innervation on recurrent life-threatening arrhythmias in the follow-up of patients with idiopathic ventricular fibrillation. Eur J Nucl Med Mol Imaging 2006;33:866-70.PubMedCrossRef Paul M, Schafers M, Kies P, Acil T, Schafers K, Breithardt G, et al. Impact of sympathetic innervation on recurrent life-threatening arrhythmias in the follow-up of patients with idiopathic ventricular fibrillation. Eur J Nucl Med Mol Imaging 2006;33:866-70.PubMedCrossRef
6.
go back to reference Boogers MJ, Borleffs CJW, Henneman MM, van Bommel RJ, van Ramshorst J, Boersma E, et al. Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients. J Am Coll Cardiol 2010;55:2769-77.PubMedCrossRef Boogers MJ, Borleffs CJW, Henneman MM, van Bommel RJ, van Ramshorst J, Boersma E, et al. Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients. J Am Coll Cardiol 2010;55:2769-77.PubMedCrossRef
7.
go back to reference Tamaki S, Yamada T, Okuyama Y, Morita T, Sanada S, Tsukamoto Y, et al. Cardiac iodine-123 metaiodobenzylguanidine imaging predicts sudden cardiac death independently of left ventricular ejection fraction in patients with chronic heart failure and left ventricular systolic dysfunction: Results from a comparative study with signal-averaged electrocardiogram, heart rate variability, and QT dispersion. J Am Coll Cardiol 2009;53:426-35.PubMedCrossRef Tamaki S, Yamada T, Okuyama Y, Morita T, Sanada S, Tsukamoto Y, et al. Cardiac iodine-123 metaiodobenzylguanidine imaging predicts sudden cardiac death independently of left ventricular ejection fraction in patients with chronic heart failure and left ventricular systolic dysfunction: Results from a comparative study with signal-averaged electrocardiogram, heart rate variability, and QT dispersion. J Am Coll Cardiol 2009;53:426-35.PubMedCrossRef
8.
go back to reference Verberne HJ, Brewster LM, Somsen GA, van Eck-Smit BLF. Prognostic value of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters in patients with heart failure: A systematic review. Eur Heart J 2008;29:1147-59.PubMedCrossRef Verberne HJ, Brewster LM, Somsen GA, van Eck-Smit BLF. Prognostic value of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters in patients with heart failure: A systematic review. Eur Heart J 2008;29:1147-59.PubMedCrossRef
9.
go back to reference Flotats A, Carrio I, Agostini D, Guludec D, Marcassa C, Schafers M, et al. Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology. Eur J Nucl Med Mol Imaging 2010;37:1802-12.PubMedCrossRef Flotats A, Carrio I, Agostini D, Guludec D, Marcassa C, Schafers M, et al. Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology. Eur J Nucl Med Mol Imaging 2010;37:1802-12.PubMedCrossRef
10.
go back to reference Somsen GA, Verberne HJ, Fleury E, Righetti A. Normal values and within-subject variability of cardiac I-123 MIBG scintigraphy in healthy individuals: Implications for clinical studies. J Nucl Cardiol 2004;11:126-33.PubMedCrossRef Somsen GA, Verberne HJ, Fleury E, Righetti A. Normal values and within-subject variability of cardiac I-123 MIBG scintigraphy in healthy individuals: Implications for clinical studies. J Nucl Cardiol 2004;11:126-33.PubMedCrossRef
11.
go back to reference Veltman CE, Boogers MJ, Meinardi JE, Al Younis I, Dibbets-Schneider P, van der Wall EE, et al. Reproducibility of planar 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure. Eur J Nucl Med Mol Imaging 2012;39:1599-608.PubMedCentralPubMedCrossRef Veltman CE, Boogers MJ, Meinardi JE, Al Younis I, Dibbets-Schneider P, van der Wall EE, et al. Reproducibility of planar 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure. Eur J Nucl Med Mol Imaging 2012;39:1599-608.PubMedCentralPubMedCrossRef
12.
go back to reference McMurray JJ, Adamopoulos S, Anker SD, Auricchio A, Bohm M, Dickstein K, et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur Heart J 2012;33:1787-847.PubMedCrossRef McMurray JJ, Adamopoulos S, Anker SD, Auricchio A, Bohm M, Dickstein K, et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur Heart J 2012;33:1787-847.PubMedCrossRef
13.
go back to reference McBride GB. A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient. NIWA Client Report: HAM 2005-062; 2005 McBride GB. A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient. NIWA Client Report: HAM 2005-062; 2005
14.
go back to reference Jacobson AF, Senior R, Cerqueira MD, Wong ND, Thomas GS, Lopez VA, et al. Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure: Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol 2010;55:2212-21.PubMedCrossRef Jacobson AF, Senior R, Cerqueira MD, Wong ND, Thomas GS, Lopez VA, et al. Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure: Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol 2010;55:2212-21.PubMedCrossRef
15.
go back to reference Merlet P, Benvenuti C, Moyse D, Pouillart F, Dubois-Rand JL, Duval AM, et al. Prognostic value of MIBG imaging in idiopathic dilated cardiomyopathy. J Nucl Med 1999;40:917-23.PubMed Merlet P, Benvenuti C, Moyse D, Pouillart F, Dubois-Rand JL, Duval AM, et al. Prognostic value of MIBG imaging in idiopathic dilated cardiomyopathy. J Nucl Med 1999;40:917-23.PubMed
16.
go back to reference Verberne HJ, Habraken J, Eck-Smit BLF, Agostini D, Jacobson AF. Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: A need for standardisation and validation. Eur J Nucl Med Mol Imaging 2008;35:547-53.PubMedCentralPubMedCrossRef Verberne HJ, Habraken J, Eck-Smit BLF, Agostini D, Jacobson AF. Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: A need for standardisation and validation. Eur J Nucl Med Mol Imaging 2008;35:547-53.PubMedCentralPubMedCrossRef
17.
go back to reference Agostini D, Carrio I, Verberne HJ. How to use myocardial 123I-MIBG scintigraphy in chronic heart failure. Eur J Nucl Med Mol Imaging 2009;36:555-9.PubMedCrossRef Agostini D, Carrio I, Verberne HJ. How to use myocardial 123I-MIBG scintigraphy in chronic heart failure. Eur J Nucl Med Mol Imaging 2009;36:555-9.PubMedCrossRef
18.
go back to reference Verberne HJ, Somsen GA, Povinec P, Eck-Smit BLF, Jacobson AF. Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout. Eur J Nucl Med Mol Imaging 2009;36:1322-8.PubMedCentralPubMedCrossRef Verberne HJ, Somsen GA, Povinec P, Eck-Smit BLF, Jacobson AF. Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout. Eur J Nucl Med Mol Imaging 2009;36:1322-8.PubMedCentralPubMedCrossRef
19.
go back to reference Dobbeleir AA, Hambye AS, Franken PR. Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds in clinical practice. Eur J Nucl Med 1999;26:655-8.PubMedCrossRef Dobbeleir AA, Hambye AS, Franken PR. Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds in clinical practice. Eur J Nucl Med 1999;26:655-8.PubMedCrossRef
20.
go back to reference Fletcher AM, Motherwell DW, Small AD, McCurrach GM, Goodfield NE, Petrie MC, et al. I-123 MIBG cardiac uptake measurements: limitations of collimator choice and scatter correction in the clinical context. Nucl Med Commun 2010;31:629-36.PubMed Fletcher AM, Motherwell DW, Small AD, McCurrach GM, Goodfield NE, Petrie MC, et al. I-123 MIBG cardiac uptake measurements: limitations of collimator choice and scatter correction in the clinical context. Nucl Med Commun 2010;31:629-36.PubMed
Metadata
Title
Impact of a predefined mediastinal ROI on inter-observer variability of planar 123I-MIBG heart-to-mediastinum ratio
Authors
Derk O. Verschure, MD
Vivian Bongers, MD, PhD
Petronella J. Hagen, MD, PhD
G. Aernout Somsen, MD, PhD
Berthe L. F. van Eck-Smit, MD, PhD
Hein J. Verberne, MD, PhD
Publication date
01-06-2014
Publisher
Springer US
Published in
Journal of Nuclear Cardiology / Issue 3/2014
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-014-9854-z

Other articles of this Issue 3/2014

Journal of Nuclear Cardiology 3/2014 Go to the issue

Editor's Page

Do We Need PET?