Abstract

Successful total knee arthroplasty (TKA) has often been based on the restoration of the knee to neutral alignment postoperatively. Numerous reports have linked malaligned TKA components to increased wear, poor functional outcomes, and failure. There have been many different alignment philosophies and surgical techniques that have been established to attain the goal of proper alignment, which includes such techniques as computerized navigation, and custom cutting guides. In addition, these methods could potentially have the added benefit of leading to improved functional outcomes following total knee arthroplasty. In this report, we have reviewed and analyzed recent reports concerning mechanical, anatomic, and kinematic axis/alignment schemes used in total knee arthroplasty.
Literature
1.
go back to reference Blumenfeld TJ. CORR Insights (R): is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res. 2013;471:3996.PubMedCrossRef Blumenfeld TJ. CORR Insights (R): is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res. 2013;471:3996.PubMedCrossRef
2.
go back to reference Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA. Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty. 2011;26:1273.PubMedCrossRef Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA. Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty. 2011;26:1273.PubMedCrossRef
3.
go back to reference D'Lima DD, Chen PC, Colwell Jr CW. Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res. 2001;392:232.PubMedCrossRef D'Lima DD, Chen PC, Colwell Jr CW. Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res. 2001;392:232.PubMedCrossRef
5.
go back to reference D'Lima DD, Hermida JC, Chen PC, Colwell Jr CW. Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res. 2001;392:124.PubMedCrossRef D'Lima DD, Hermida JC, Chen PC, Colwell Jr CW. Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res. 2001;392:124.PubMedCrossRef
6.
go back to reference Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, et al. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26.PubMedCrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, et al. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26.PubMedCrossRef
7.
go back to reference Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res. 2007;457:156.PubMed Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res. 2007;457:156.PubMed
8.
go back to reference Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg (Br). 1991;73:709. Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg (Br). 1991;73:709.
9.
go back to reference Oswald MH, Jakob RP, Schneider E, Hoogewoud HM. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 1993;8:419.PubMedCrossRef Oswald MH, Jakob RP, Schneider E, Hoogewoud HM. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 1993;8:419.PubMedCrossRef
10.
go back to reference Sikorski JM. Alignment in total knee replacement. J Bone Joint Surg (Br). 2008;90:1121.CrossRef Sikorski JM. Alignment in total knee replacement. J Bone Joint Surg (Br). 2008;90:1121.CrossRef
11.
go back to reference Johnson AJ, Harwin SF, Krakow KA, Mont MA. Alignment in total knee arthroplasty: where have we come from and where are we going? Surg Technol Int. 2011;XXI:183.PubMed Johnson AJ, Harwin SF, Krakow KA, Mont MA. Alignment in total knee arthroplasty: where have we come from and where are we going? Surg Technol Int. 2011;XXI:183.PubMed
12.••
go back to reference Incavo SJ, Schmid S, Sreenivas K, Ismaily S, Noble PC. Total knee arthroplasty using anatomic alignment can produce mid-flexion laxity. Clin Biomech. 2013;28:429. With the use of anatomic alignment in TKA, mid-lexion laxity becomes a concern.CrossRef Incavo SJ, Schmid S, Sreenivas K, Ismaily S, Noble PC. Total knee arthroplasty using anatomic alignment can produce mid-flexion laxity. Clin Biomech. 2013;28:429. With the use of anatomic alignment in TKA, mid-lexion laxity becomes a concern.CrossRef
13.
go back to reference Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57.PubMedCentralPubMedCrossRef Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57.PubMedCentralPubMedCrossRef
14.
go back to reference Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br). 2007;89:893.CrossRef Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br). 2007;89:893.CrossRef
15.
go back to reference Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180.PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180.PubMedCrossRef
16.
go back to reference Harvie P, Sloan K, Beaver RJ. Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems. J Arthroplasty. 2011;26:1285.PubMedCrossRef Harvie P, Sloan K, Beaver RJ. Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems. J Arthroplasty. 2011;26:1285.PubMedCrossRef
17.
go back to reference Molli RG, Anderson KC, Buehler KC, Markel DC. Computer-assisted navigation software advancements improve the accuracy of total knee arthroplasty. J Arthroplasty. 2011;26:432.PubMedCrossRef Molli RG, Anderson KC, Buehler KC, Markel DC. Computer-assisted navigation software advancements improve the accuracy of total knee arthroplasty. J Arthroplasty. 2011;26:432.PubMedCrossRef
18.
go back to reference Schmitt J, Hauk C, Kienapfel H, Pfeiffer M, Efe T, Fuchs-Winkelmann S, et al. Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study. BMC Musculoskelet Disord. 2011;12:16.PubMedCentralPubMedCrossRef Schmitt J, Hauk C, Kienapfel H, Pfeiffer M, Efe T, Fuchs-Winkelmann S, et al. Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study. BMC Musculoskelet Disord. 2011;12:16.PubMedCentralPubMedCrossRef
19.
go back to reference Harvie P, Sloan K, Beaver RJ. Computer navigation vs conventional total knee arthroplasty: five-year functional results of a prospective randomized trial. J Arthroplasty. 2012;27:667.PubMedCrossRef Harvie P, Sloan K, Beaver RJ. Computer navigation vs conventional total knee arthroplasty: five-year functional results of a prospective randomized trial. J Arthroplasty. 2012;27:667.PubMedCrossRef
20.
go back to reference Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567.PubMedCentralPubMedCrossRef Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567.PubMedCentralPubMedCrossRef
22.
go back to reference Tang WM, Zhu YH, Chiu KY. Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am. 2000;82-A:1603.PubMed Tang WM, Zhu YH, Chiu KY. Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am. 2000;82-A:1603.PubMed
23.
go back to reference Moreland JR, Bassett LW, Hanker GJ. Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am. 1987;69:745.PubMed Moreland JR, Bassett LW, Hanker GJ. Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am. 1987;69:745.PubMed
24.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D. Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am. 1987;69:332.PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D. Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am. 1987;69:332.PubMed
25.
go back to reference Willcox NM, Clarke JV, Smith BR, Deakin AH, Deep K. A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement. J Bone Joint Surg (Br). 2012;94:1234.CrossRef Willcox NM, Clarke JV, Smith BR, Deakin AH, Deep K. A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement. J Bone Joint Surg (Br). 2012;94:1234.CrossRef
26.
go back to reference Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF. Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res. 2000;371:246.PubMedCrossRef Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF. Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res. 2000;371:246.PubMedCrossRef
27.
go back to reference Koshino T, Takeyama M, Jiang LS, Yoshida T, Saito T. Underestimation of varus angulation in knees with flexion deformity. Knee. 2002;9:275.PubMedCrossRef Koshino T, Takeyama M, Jiang LS, Yoshida T, Saito T. Underestimation of varus angulation in knees with flexion deformity. Knee. 2002;9:275.PubMedCrossRef
28.
go back to reference Scott W. Kinematic Alignment In Total Knee Arthroplasty. Insall & Scott Surgery of the Knee. 5th ed. Ch. 121; 1255–1268. Churchill Livingstone: 2012. Scott W. Kinematic Alignment In Total Knee Arthroplasty. Insall & Scott Surgery of the Knee. 5th ed. Ch. 121; 1255–1268. Churchill Livingstone: 2012.
29.••
go back to reference Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res. 2013;471:1000. Kinematically aligned TKA restores function without failure regardless of the alignment category.PubMedCentralPubMedCrossRef Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res. 2013;471:1000. Kinematically aligned TKA restores function without failure regardless of the alignment category.PubMedCentralPubMedCrossRef
30.••
go back to reference Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically vs mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160. Kinematic alignment of the knee lead to superior outcomes in WOMAC, Oxford Score, KSS, and flexion compared with mechanical alignment.PubMed Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically vs mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160. Kinematic alignment of the knee lead to superior outcomes in WOMAC, Oxford Score, KSS, and flexion compared with mechanical alignment.PubMed
31.
go back to reference Hsu RW, Himeno S, Coventry MB, Chao EY. Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res. 1990;255:215.PubMed Hsu RW, Himeno S, Coventry MB, Chao EY. Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res. 1990;255:215.PubMed
32.••
go back to reference Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45. A large portion of the population has a natural alignment of 3° of varus or more. Restoration of mechanical axis may not be desirable in these patients.PubMedCentralPubMedCrossRef Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45. A large portion of the population has a natural alignment of 3° of varus or more. Restoration of mechanical axis may not be desirable in these patients.PubMedCentralPubMedCrossRef
33.•
go back to reference Fahlman L, Sangeorzan E, Chheda N, Lambright D. Older adults without radiographic knee osteoarthritis: knee alignment and knee range of motion. Clin Med Insights Arthritis Musculoskelet Disord. 2014;7:1. This study demonstrated that a large portion of the population has varying alignment of both lower extremities.PubMedCentralPubMedCrossRef Fahlman L, Sangeorzan E, Chheda N, Lambright D. Older adults without radiographic knee osteoarthritis: knee alignment and knee range of motion. Clin Med Insights Arthritis Musculoskelet Disord. 2014;7:1. This study demonstrated that a large portion of the population has varying alignment of both lower extremities.PubMedCentralPubMedCrossRef
34.
go back to reference Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res. 1985;192:13.PubMed Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res. 1985;192:13.PubMed
35.
go back to reference Hungerford DS, Krackow KA. Total joint arthroplasty of the knee. Clin Orthop Relat Res. 1985;192:23.PubMed Hungerford DS, Krackow KA. Total joint arthroplasty of the knee. Clin Orthop Relat Res. 1985;192:23.PubMed
36.
go back to reference Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, et al. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87 Suppl 2:71.PubMedCrossRef Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, et al. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87 Suppl 2:71.PubMedCrossRef
37.
go back to reference Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259.PubMed Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259.PubMed
38.
go back to reference Teixeira LF, Olney SJ. Relationship between alignment and kinematic and kinetic measures of the knee of osteoarthritic elderly subjects in level walking. Clin Biomech. 1996;11:126.CrossRef Teixeira LF, Olney SJ. Relationship between alignment and kinematic and kinetic measures of the knee of osteoarthritic elderly subjects in level walking. Clin Biomech. 1996;11:126.CrossRef
39.••
go back to reference Nogler M, Hozack W, Collopy D, Mayr E, Deirmengian G, Sekyra K. Alignment for total knee replacement: a comparison of kinematic axis vs mechanical axis techniques. A cadaver study. Int Orthop. 2012;36:2249. In cadavers there were no significant differences in overall alignment between the use of kinematic and mechanical axis techniques.PubMedCentralPubMedCrossRef Nogler M, Hozack W, Collopy D, Mayr E, Deirmengian G, Sekyra K. Alignment for total knee replacement: a comparison of kinematic axis vs mechanical axis techniques. A cadaver study. Int Orthop. 2012;36:2249. In cadavers there were no significant differences in overall alignment between the use of kinematic and mechanical axis techniques.PubMedCentralPubMedCrossRef
40.•
go back to reference Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP. Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc. 2013;21:2206. There was no difference in obtaining mechanical axis and correct component position between patient specific surgery and conventional TKA.PubMedCrossRef Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP. Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc. 2013;21:2206. There was no difference in obtaining mechanical axis and correct component position between patient specific surgery and conventional TKA.PubMedCrossRef
41.
go back to reference Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(6 Suppl):39.PubMedCrossRef Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(6 Suppl):39.PubMedCrossRef
42.
go back to reference Choong PF, Dowsey MM, Stoney JD. Does accurate anatomic alignment result in better function and quality of life?.Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty. 2009;24:560.PubMedCrossRef Choong PF, Dowsey MM, Stoney JD. Does accurate anatomic alignment result in better function and quality of life?.Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty. 2009;24:560.PubMedCrossRef
43.•
go back to reference Khan MM, Khan MW, Al-Harbi HH, Weening BS, Zalzal PK. Assessing short-term functional outcomes and knee alignment of computer-assisted navigated total knee arthroplasty. J Arthroplasty. 2012;27:271. The use of CAS in TKA showed no improvement in WOMAC and SF-12 survey with functional arc alignment.PubMedCrossRef Khan MM, Khan MW, Al-Harbi HH, Weening BS, Zalzal PK. Assessing short-term functional outcomes and knee alignment of computer-assisted navigated total knee arthroplasty. J Arthroplasty. 2012;27:271. The use of CAS in TKA showed no improvement in WOMAC and SF-12 survey with functional arc alignment.PubMedCrossRef
44.••
go back to reference Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143. Patients that are outliers of mechanical alignment did not necessarily result in worse outcomes after total knee.PubMedCrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143. Patients that are outliers of mechanical alignment did not necessarily result in worse outcomes after total knee.PubMedCrossRef
45.••
go back to reference Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop. 2009;33:1571. This study demonstrated that custom-fit total knee has similar alignment compared with conventional techniques.PubMedCentralPubMedCrossRef Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop. 2009;33:1571. This study demonstrated that custom-fit total knee has similar alignment compared with conventional techniques.PubMedCentralPubMedCrossRef
Metadata
Title
Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications
Authors
Jeffrey J. Cherian
Bhaveen H. Kapadia
Samik Banerjee
Julio J. Jauregui
Kimona Issa
Michael A. Mont
Publication date
01-06-2014
Publisher
Springer US
Published in
Current Reviews in Musculoskeletal Medicine / Issue 2/2014
Electronic ISSN: 1935-9748
DOI
https://doi.org/10.1007/s12178-014-9218-y

Other articles of this Issue 2/2014

Current Reviews in Musculoskeletal Medicine 2/2014 Go to the issue

Resident Education (P Achan, Section Editor)

Matching residency numbers to the workforce needs

TKA Symposium (P Sancheti, Section Editor)

Patient specific implants: scope for the future

Resident Education (P Achan, Section Editor)

What makes a “great resident”: the resident perspective