Skip to main content
Top
Published in: International Orthopaedics 6/2009

01-12-2009 | Original Paper

Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment

Authors: Brian A. Spencer, Michael A. Mont, Mike S. McGrath, Bradley Boyd, Michael F. Mitrick

Published in: International Orthopaedics | Issue 6/2009

Login to get access

Abstract

New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient’s pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon’s previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2° of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.
Literature
1.
go back to reference Coughlin KM, Incavo SJ, Churchill DL, Beynnon BD (2003) Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. J Arthroplasty 18(8):1048–1055CrossRefPubMed Coughlin KM, Incavo SJ, Churchill DL, Beynnon BD (2003) Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. J Arthroplasty 18(8):1048–1055CrossRefPubMed
2.
go back to reference Eckhoff DG, Bach JM, Spitzer VM et al (2005) Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 87(Suppl 2):71–80CrossRefPubMed Eckhoff DG, Bach JM, Spitzer VM et al (2005) Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 87(Suppl 2):71–80CrossRefPubMed
3.
go back to reference Eckhoff DG, Bach JM, Spitzer VM, Reinig KD et al (2003) Three-dimensional morphology and kinematics of the distal part of the femur viewed in virtual reality. J Bone Joint Surg Am 85(Suppl 4):97–104PubMed Eckhoff DG, Bach JM, Spitzer VM, Reinig KD et al (2003) Three-dimensional morphology and kinematics of the distal part of the femur viewed in virtual reality. J Bone Joint Surg Am 85(Suppl 4):97–104PubMed
4.
go back to reference Eckhoff DG, Dwyer TF, Bach JM, Spitzer VM et al (2001) Three-dimensional morphology of the distal part of the femur viewed in virtual reality. J Bone Joint Surg Am 83(Suppl 2):43–50PubMed Eckhoff DG, Dwyer TF, Bach JM, Spitzer VM et al (2001) Three-dimensional morphology of the distal part of the femur viewed in virtual reality. J Bone Joint Surg Am 83(Suppl 2):43–50PubMed
5.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed
6.
go back to reference Klatt BA, Goyal N, Austin MS, Hozack WJ (2008) Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 23(1):26–29CrossRefPubMed Klatt BA, Goyal N, Austin MS, Hozack WJ (2008) Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 23(1):26–29CrossRefPubMed
7.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, ramdomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89(2):236–243CrossRefPubMed Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, ramdomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89(2):236–243CrossRefPubMed
8.
go back to reference Parratte S, Trousdale R, Berry DJ, Pagnano MW (2008) Reproducing the mechanical axis did not improve the 15-year survival of 398 modern TKA. Scientific presentation, AAOS Annual Meeting, San Francisco, CA Parratte S, Trousdale R, Berry DJ, Pagnano MW (2008) Reproducing the mechanical axis did not improve the 15-year survival of 398 modern TKA. Scientific presentation, AAOS Annual Meeting, San Francisco, CA
9.
go back to reference Piazza SJ, Delp SL, Stulberg SD, Stern SH (1998) Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: a computer simulation study. J Orthop Res 16(2):264–270CrossRefPubMed Piazza SJ, Delp SL, Stulberg SD, Stern SH (1998) Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: a computer simulation study. J Orthop Res 16(2):264–270CrossRefPubMed
10.
go back to reference Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480CrossRefPubMed Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480CrossRefPubMed
11.
go back to reference Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Joint Surg Am 88(Suppl 4):47–54CrossRefPubMed Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Joint Surg Am 88(Suppl 4):47–54CrossRefPubMed
Metadata
Title
Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment
Authors
Brian A. Spencer
Michael A. Mont
Mike S. McGrath
Bradley Boyd
Michael F. Mitrick
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0693-x

Other articles of this Issue 6/2009

International Orthopaedics 6/2009 Go to the issue