Skip to main content
Top
Published in: Japanese Journal of Radiology 10/2017

01-10-2017 | Technical Note

Methods for optimizing the display conditions of brain magnetic resonance images

Authors: Toshimasa Hara, Yusuke Inoue, Ryutaro Ukisu, Hirofumi Hata

Published in: Japanese Journal of Radiology | Issue 10/2017

Login to get access

Abstract

Purpose

To investigate a method for optimizing the display conditions of brain magnetic resonance (MR) images.

Materials and methods

We retrospectively analyzed brain MR images of 120 adults classified into screening, acute cerebral infarction, and brain tumor groups (n = 40 each). Two observers independently displayed the images on a monitor and optimized the display conditions using the W/L and U/L methods. In the W/L method, the observers manipulated the width and level of the display window, while in the U/L method they manipulated the upper and lower levels of the window. The times required were compared between the two methods. Additionally, the appropriateness of the determined window setting was evaluated visually by the respective observer to exclude the possibility that rough, suboptimal adjustment shortened the adjustment time.

Results

For both observers and all groups, the time required for optimization was significantly shorter for the U/L method than for the W/L method. The appropriateness of the window setting for the U/L method was equal to or better than that for the W/L method.

Conclusion

Manipulating the upper and lower levels of the display window appears to improve the efficiency of interpreting brain MR images through rapid optimization of the display condition.
Literature
1.
go back to reference Pomerantz SM, White CS, Krebs TL, Daly B, Sukumar SA, Hooper F, et al. Liver and bone window settings for soft-copy interpretation of chest and abdominal CT. AJR Am J Roentgenol. 2000;174:311–4.CrossRefPubMed Pomerantz SM, White CS, Krebs TL, Daly B, Sukumar SA, Hooper F, et al. Liver and bone window settings for soft-copy interpretation of chest and abdominal CT. AJR Am J Roentgenol. 2000;174:311–4.CrossRefPubMed
2.
go back to reference Lamba R, McGahan JP, Corwin MT, Li CS, Tran T, Seibert JA, et al. CT Hounsfield numbers of soft tissues on unenhanced abdominal CT scans: variability between two different manufacturers’ MDCT scanners. AJR Am J Roentgenol. 2014;203:1013–20.CrossRefPubMedPubMedCentral Lamba R, McGahan JP, Corwin MT, Li CS, Tran T, Seibert JA, et al. CT Hounsfield numbers of soft tissues on unenhanced abdominal CT scans: variability between two different manufacturers’ MDCT scanners. AJR Am J Roentgenol. 2014;203:1013–20.CrossRefPubMedPubMedCentral
3.
go back to reference Nyúl LG, Udupa JK. On standardizing the MR image intensity scale. Magn Reson Med. 1999;42:1072–81.CrossRefPubMed Nyúl LG, Udupa JK. On standardizing the MR image intensity scale. Magn Reson Med. 1999;42:1072–81.CrossRefPubMed
4.
go back to reference Robitaille N, Mouiha A, Crépeault B, Valdivia F, Duchesne S. The Alzheimer’s disease neuroimaging initiative. Tissue-based MRI intensity standardization: application to multicentric datasets. Int J Biomed Imaging. 2012;2012:347120.PubMedPubMedCentral Robitaille N, Mouiha A, Crépeault B, Valdivia F, Duchesne S. The Alzheimer’s disease neuroimaging initiative. Tissue-based MRI intensity standardization: application to multicentric datasets. Int J Biomed Imaging. 2012;2012:347120.PubMedPubMedCentral
5.
go back to reference Sasaki M, Ida M, Yamada K, Watanabe Y, Matsui M. Standardizing display conditions of diffusion-weighted images using concurrent b0 images: a multi-vendor multi-institutional study. Magn Reson Med Sci. 2007;6:133–7.CrossRefPubMed Sasaki M, Ida M, Yamada K, Watanabe Y, Matsui M. Standardizing display conditions of diffusion-weighted images using concurrent b0 images: a multi-vendor multi-institutional study. Magn Reson Med Sci. 2007;6:133–7.CrossRefPubMed
6.
go back to reference Hirai T, Sasaki M, Maeda M, Ida M, Katsuragawa S, Sakoh M, et al. Diffusion-weighted imaging in ischemic stroke: effect of display method on observers’ diagnostic performance. Acad Radiol. 2009;16:305–12.CrossRefPubMed Hirai T, Sasaki M, Maeda M, Ida M, Katsuragawa S, Sakoh M, et al. Diffusion-weighted imaging in ischemic stroke: effect of display method on observers’ diagnostic performance. Acad Radiol. 2009;16:305–12.CrossRefPubMed
7.
go back to reference Nagashima H, Doi K, Ogura T, Fujita H. Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke. Radiol Phys Technol. 2013;6:202–9.CrossRefPubMed Nagashima H, Doi K, Ogura T, Fujita H. Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke. Radiol Phys Technol. 2013;6:202–9.CrossRefPubMed
8.
go back to reference Gillespy T 3rd, Rowberg AH. Displaying radiologic images on personal computers. J Digit Imaging. 1993;6:151–63.CrossRefPubMed Gillespy T 3rd, Rowberg AH. Displaying radiologic images on personal computers. J Digit Imaging. 1993;6:151–63.CrossRefPubMed
10.
go back to reference Wheaton AJ, Miyazaki M. Non-contrast enhanced MR angiography: physical principles. J Magn Reson Imaging. 2012;36:286–304.CrossRefPubMed Wheaton AJ, Miyazaki M. Non-contrast enhanced MR angiography: physical principles. J Magn Reson Imaging. 2012;36:286–304.CrossRefPubMed
Metadata
Title
Methods for optimizing the display conditions of brain magnetic resonance images
Authors
Toshimasa Hara
Yusuke Inoue
Ryutaro Ukisu
Hirofumi Hata
Publication date
01-10-2017
Publisher
Springer Japan
Published in
Japanese Journal of Radiology / Issue 10/2017
Print ISSN: 1867-1071
Electronic ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-017-0669-0

Other articles of this Issue 10/2017

Japanese Journal of Radiology 10/2017 Go to the issue