Published in: The International Journal of Cardiovascular Imaging 6/2018

Open Access 01-06-2018 | Original Paper

Scan–rescan reproducibility of diastolic left ventricular kinetic energy, viscous energy loss and vorticity assessment using 4D flow MRI: analysis in healthy subjects

Authors: Vivian P. Kamphuis, Jos J. M. Westenberg, Roel L. F. van der Palen, Pieter J. van den Boogaard, Rob J. van der Geest, Albert de Roos, Nico A. Blom, Arno A. W. Roest, Mohammed S. M. Elbaz

Published in: The International Journal of Cardiovascular Imaging | Issue 6/2018

Login to get access

Abstract

The aim of the current study was to assess the scan–rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. ELindex was computed to measure the amount of EL relative to KE over diastole. Scan–rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, ELindex and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64–0.95] and coefficients of variation (CV) ≤ 25%. ELindex showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan–rescan reproducibility of volumetric vorticity showed good–excellent ICCs (0.83–0.95) with CVs ≤ 11%. In conclusion, the current study shows strong–excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless ELindex, which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
Appendix
Available only for authorised users
Literature
10.
go back to reference Kheradvar AP, G (2012) Vortex formation in the heart. In: Vortex formation in the cardiovascular system. Springer, London, p 19CrossRef Kheradvar AP, G (2012) Vortex formation in the heart. In: Vortex formation in the cardiovascular system. Springer, London, p 19CrossRef
15.
16.
go back to reference Garg P, Westenberg JJM, van den Boogaard PJ, Swoboda PP, Aziz R, Foley JRJ, Fent GJ, Tyl FGJ, Coratella L, ElBaz MSM, van der Geest RJ, Higgins DM, Greenwood JP, Plein S (2017) Comparison of fast acquisition strategies in whole-heart four-dimensional flow cardiac MR: two-center, 1.5 T, phantom and in vivo validation study. J Magn Reson Imaging. https://doi.org/10.1002/jmri.25746 PubMedPubMedCentralCrossRef Garg P, Westenberg JJM, van den Boogaard PJ, Swoboda PP, Aziz R, Foley JRJ, Fent GJ, Tyl FGJ, Coratella L, ElBaz MSM, van der Geest RJ, Higgins DM, Greenwood JP, Plein S (2017) Comparison of fast acquisition strategies in whole-heart four-dimensional flow cardiac MR: two-center, 1.5 T, phantom and in vivo validation study. J Magn Reson Imaging. https://​doi.​org/​10.​1002/​jmri.​25746 PubMedPubMedCentralCrossRef
18.
go back to reference Agati L, Cimino S, Tonti G, Cicogna F, Petronilli V, De Luca L, Iacoboni C, Pedrizzetti G (2014) Quantitative analysis of intraventricular blood flow dynamics by echocardiographic particle image velocimetry in patients with acute myocardial infarction at different stages of left ventricular dysfunction. Eur Heart J Cardiovasc Imaging 15(11):1203–1212. https://doi.org/10.1093/ehjci/jeu106 CrossRefPubMed Agati L, Cimino S, Tonti G, Cicogna F, Petronilli V, De Luca L, Iacoboni C, Pedrizzetti G (2014) Quantitative analysis of intraventricular blood flow dynamics by echocardiographic particle image velocimetry in patients with acute myocardial infarction at different stages of left ventricular dysfunction. Eur Heart J Cardiovasc Imaging 15(11):1203–1212. https://​doi.​org/​10.​1093/​ehjci/​jeu106 CrossRefPubMed
19.
go back to reference Hyslop NP, White WH (2009) Estimating precision using duplicate measurements. J Air Waste Manag Assoc 59(9):1032–1039CrossRefPubMed Hyslop NP, White WH (2009) Estimating precision using duplicate measurements. J Air Waste Manag Assoc 59(9):1032–1039CrossRefPubMed
20.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed
22.
go back to reference Mohiaddin RH (1995) Flow patterns in the dilated ischemic left ventricle studied by MR imaging with velocity vector mapping. J Magn Reson Imaging 5(5):493–498CrossRefPubMed Mohiaddin RH (1995) Flow patterns in the dilated ischemic left ventricle studied by MR imaging with velocity vector mapping. J Magn Reson Imaging 5(5):493–498CrossRefPubMed
23.
27.
go back to reference Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ (2002) Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90(1):29–34CrossRefPubMed Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ (2002) Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90(1):29–34CrossRefPubMed
28.
go back to reference van der Geest RJ, Reiber JH (1999) Quantification in cardiac MRI. J Magn Reson Imaging 10(5):602–608CrossRefPubMed van der Geest RJ, Reiber JH (1999) Quantification in cardiac MRI. J Magn Reson Imaging 10(5):602–608CrossRefPubMed
Metadata
Title
Scan–rescan reproducibility of diastolic left ventricular kinetic energy, viscous energy loss and vorticity assessment using 4D flow MRI: analysis in healthy subjects
Authors
Vivian P. Kamphuis
Jos J. M. Westenberg
Roel L. F. van der Palen
Pieter J. van den Boogaard
Rob J. van der Geest
Albert de Roos
Nico A. Blom
Arno A. W. Roest
Mohammed S. M. Elbaz
Publication date
01-06-2018
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 6/2018
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1291-z

Other articles of this Issue 6/2018

The International Journal of Cardiovascular Imaging 6/2018 Go to the issue