Introduction

The adequate way of mesh fixation in laparoscopic ventral hernia repair is still subject to debate. So far, simulation has only been carried out in a static way, thereby omitting dynamic effects of coughing or vomiting. We developed a dynamic model of the anterior abdominal wall.

Materials and methods

An aluminium cylinder was equipped with a pressure controlled, fluid-filled plastic bag, simulating the abdominal viscera. A computer-controlled system allowed the control of influx and efflux, thus creating pressure peaks of up to 200 mmHg to simulate coughing and 290 mmHg to simulate vomiting. We tested fixation with tacks (Absorbatack, Covidien Deutschland, Neustadt a. D., Germany). The model was controlled for the friction coefficient of the tissue against the mesh and the physiologic elasticity of the abdominal wall surrogate.

Results

The model was able to create pressure peaks equivalent to physiologic coughs or vomiting. Physiologic elasticity was thereby maintained. We could show that the friction coefficient is crucial to achieve a physiologic situation.
The meshes showed a tendency to dislocate with an increasing number of coughs (Fig. 4). Nevertheless, when applied in a plain manner, the meshes withstood more cough cycles than when applied with a bulge as in laparoscopic surgery.

Conclusions

The dynamic movement of the abdominal wall, the friction between tissue and mesh and the way of mesh application are crucial factors that have to be controlled for in simulation of ventral abdominal hernia closure. We could demonstrate that patient specific factors such as the frequency of coughing as well as the application technique influence the long term stability of the mesh.
Literature
1.
go back to reference Helgstrand F, Rosenberg J, Kehlet H, Strandfelt P, Bisgaard T. (2012) Reoperation Versus Clinical Recurrence Rate After Ventral Hernia Repair. Ann Surg. (2012) May 10 Helgstrand F, Rosenberg J, Kehlet H, Strandfelt P, Bisgaard T. (2012) Reoperation Versus Clinical Recurrence Rate After Ventral Hernia Repair. Ann Surg. (2012) May 10
2.
go back to reference Byrd JF, Agee N, Swan RZ, Lau KN, Heath JJ, McKillop IH, Sindram D, Martinie JB, Iannitti DA (2011) Evaluation of absorbable and permanent mesh fixation devices: adhesion formation and mechanical strength. Hernia 15:553–558PubMedCrossRef Byrd JF, Agee N, Swan RZ, Lau KN, Heath JJ, McKillop IH, Sindram D, Martinie JB, Iannitti DA (2011) Evaluation of absorbable and permanent mesh fixation devices: adhesion formation and mechanical strength. Hernia 15:553–558PubMedCrossRef
3.
go back to reference Melman L, Jenkins ED, Deeken, CR, Brodt, MD, Brown SR, Brunt LM, Eagon JC, Frisella M and Matthews BD (2010) Evaluation of Acute Fixation Strength for Mechanical Tacking Devices and Fibrin Sealant Versus Polypropylene Suture for Laparoscopic Ventral Hernia Repair Surgical Innovation 17(4):285–290 Melman L, Jenkins ED, Deeken, CR, Brodt, MD, Brown SR, Brunt LM, Eagon JC, Frisella M and Matthews BD (2010) Evaluation of Acute Fixation Strength for Mechanical Tacking Devices and Fibrin Sealant Versus Polypropylene Suture for Laparoscopic Ventral Hernia Repair Surgical Innovation 17(4):285–290
4.
go back to reference Rieder E, Stoiber M, Scheikl V, Poglitsch M, Dal Borgo A, Prager G, Schima H (2011) Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes. J Am Coll Surg 212(1):80–86PubMedCrossRef Rieder E, Stoiber M, Scheikl V, Poglitsch M, Dal Borgo A, Prager G, Schima H (2011) Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes. J Am Coll Surg 212(1):80–86PubMedCrossRef
5.
go back to reference Cobb WS, Burns JM, Kercher KW, Matthews BD, James Norton H, Todd HB (2005) Normal intraabdominal pressure in healthy adults. J Surg Res 129(2):231–235PubMedCrossRef Cobb WS, Burns JM, Kercher KW, Matthews BD, James Norton H, Todd HB (2005) Normal intraabdominal pressure in healthy adults. J Surg Res 129(2):231–235PubMedCrossRef
6.
go back to reference Iqbal A, Haider M, Stadlhuber RJ, Karu A, Corkill S, Filipi CJ (2008) A study of intragastric and intravesicular pressure changes during rest, coughing, weight lifting, retching, and vomiting. Surg Endosc 22:2571–2575PubMedCrossRef Iqbal A, Haider M, Stadlhuber RJ, Karu A, Corkill S, Filipi CJ (2008) A study of intragastric and intravesicular pressure changes during rest, coughing, weight lifting, retching, and vomiting. Surg Endosc 22:2571–2575PubMedCrossRef
7.
go back to reference Schwab R, Klinge U, Schumacher O, Binnebosel M, Junge K, Schumpelick V (1999) In: Schumpelick V (ed) Biomechanical data—“Hernia Mechanics”: hernia size, overlap and mesh fixation in incisional hernia. Incisional Hernia, Berlin Schwab R, Klinge U, Schumacher O, Binnebosel M, Junge K, Schumpelick V (1999) In: Schumpelick V (ed) Biomechanical data—“Hernia Mechanics”: hernia size, overlap and mesh fixation in incisional hernia. Incisional Hernia, Berlin
8.
go back to reference Kelton JG, Ulan R, Stiller C, Holmes E (1978) Comparison of chemical composition of peritoneal fluid and serum: a method for monitoring dialysis patients and a tool for assessing binding to serum proteins in vivo. Ann Intern Med 89(1):67–70PubMedCrossRef Kelton JG, Ulan R, Stiller C, Holmes E (1978) Comparison of chemical composition of peritoneal fluid and serum: a method for monitoring dialysis patients and a tool for assessing binding to serum proteins in vivo. Ann Intern Med 89(1):67–70PubMedCrossRef
9.
go back to reference Zinther NB, Wara P, Friis-Andersen H (2010) Intraperitoneal onlay mesh: an experimental study of adhesion formation in a sheep model. Hernia 14:283–289PubMedCrossRef Zinther NB, Wara P, Friis-Andersen H (2010) Intraperitoneal onlay mesh: an experimental study of adhesion formation in a sheep model. Hernia 14:283–289PubMedCrossRef
10.
go back to reference Schug-Pass C, Lippert H, Köckerling F (2009) Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model. Surg Endosc 23:2809–2815PubMedCrossRef Schug-Pass C, Lippert H, Köckerling F (2009) Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model. Surg Endosc 23:2809–2815PubMedCrossRef
11.
go back to reference Schug-Pass C, Lippert H, Köckerling F, Mesh fixation with fibrin glue (Tissucol/Tisseel®) in hernia repair dependent on the mesh structure—is there an optimum fibrin–mesh combination?—Investigations on a biomechanical model Langenbecks Arch Surg doi:10.1007/s00423-009-0466-z Schug-Pass C, Lippert H, Köckerling F, Mesh fixation with fibrin glue (Tissucol/Tisseel®) in hernia repair dependent on the mesh structure—is there an optimum fibrin–mesh combination?—Investigations on a biomechanical model Langenbecks Arch Surg doi:10.​1007/​s00423-009-0466-z
Metadata
Title
Development of a dynamic model for ventral hernia mesh repair
Authors
M. Siassi
A. Mahn
E. Baumann
M. Vollmer
G. Huber
M. Morlock
F. Kallinowski
Publication date
01-10-2014
Publisher
Springer Berlin Heidelberg
Published in
Langenbeck's Archives of Surgery / Issue 7/2014
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-014-1239-x

Other articles of this Issue 7/2014

Langenbeck's Archives of Surgery 7/2014 Go to the issue