01-01-2021 | Autopsy | Short Communication

Usefulness of a blood glucose and ketone monitoring device as a screening tool for lethal diabetic ketoacidosis

Authors: Pierre-Antoine Peyron, Maëlle Plawecki, Maisy Lossois, Manuela Lotierzo, Eric Baccino, Jean-Paul Cristol

Published in: International Journal of Legal Medicine | Issue 1/2021

Login to get access

Abstract

Diabetic ketoacidosis (DKA) is a frequent and life-threatening complication, whose diagnosis remains challenging in forensic practice. We aimed at assessing the performance of a commercially available blood glucose and ketone monitoring device (BGMD) in measuring glucose and ketone levels in post-mortem vitreous (VH) and blood samples, in order to determine if such a device can be used for screening lethal cases of DKA at autopsy. VH and blood samples were collected in cases of unexplained causes of death at autopsy. Glucose and β-hydroxybutyrate (BHB) were measured in VH and BHB in blood using the BGMD. The values were compared to those obtained with validated enzymatic methods. Values ≥ 10 mmol/L were considered to be elevated for glucose, and BHB values ≥ 2.5 mmol/L were considered to indicate ketoacidosis. There was a strong and significant correlation between VH glucose and blood BHB concentrations measured with the BGMD and the validated method (r = 0.78 and r = 0.80, p < 0.0001, respectively), whereas no correlation was found for VH BHB values (r = 0.19, p = 0.19). The sensitivity and specificity of the BGMD were both excellent (1.0) to detect elevated VH glucose levels with a threshold of 14.4 mmol/L, and to detect elevated blood BHB levels with a threshold of 2.85 mmol/L. In contrast, the specificity of the BGMD to detect high BHB levels in VH was poor (0.50) with an optimal threshold of 2.5 mmol/L. We showed that a commercially available BGMD is suitable for identifying cases of lethal DKA and other metabolic disorders at autopsy, through the investigation of vitreous glucose and blood BHB. We therefore recommend the systematic use of a BGMD for screening these conditions in cases of unexplained deaths.
Literature
10.
go back to reference (2019) Classification of diabetes mellitus. World Health Organization, Geneva (2019) Classification of diabetes mellitus. World Health Organization, Geneva
12.
go back to reference Iten PX, Meier M (2000) Beta-hydroxybutyric acid--an indicator for an alcoholic ketoacidosis as cause of death in deceased alcohol abusers. J Forensic Sci 45:624–632CrossRef Iten PX, Meier M (2000) Beta-hydroxybutyric acid--an indicator for an alcoholic ketoacidosis as cause of death in deceased alcohol abusers. J Forensic Sci 45:624–632CrossRef
16.
go back to reference Heimer J, Gascho D, Madea B, Steuer A, Martinez RM, Thali MJ, Zoelch N (2020) Comparison of the beta-hydroxybutyrate, glucose, and lactate concentrations derived from postmortem proton magnetic resonance spectroscopy and biochemical analysis for the diagnosis of fatal metabolic disorders. Int J Legal Med 134:603–612. https://doi.org/10.1007/s00414-019-02235-6CrossRefPubMed Heimer J, Gascho D, Madea B, Steuer A, Martinez RM, Thali MJ, Zoelch N (2020) Comparison of the beta-hydroxybutyrate, glucose, and lactate concentrations derived from postmortem proton magnetic resonance spectroscopy and biochemical analysis for the diagnosis of fatal metabolic disorders. Int J Legal Med 134:603–612. https://​doi.​org/​10.​1007/​s00414-019-02235-6CrossRefPubMed
17.
go back to reference Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRef Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRef
18.
go back to reference Sturner WQ, Gantner GE (1964) Postmortem vitreous glucose determinations. J Forensic Sci 9:485–491PubMed Sturner WQ, Gantner GE (1964) Postmortem vitreous glucose determinations. J Forensic Sci 9:485–491PubMed
19.
go back to reference Gagajewski A, Murakami MM, Kloss J, Edstrom M, Hillyer M, Peterson GF, Amatuzio J, Apple FS (2004) Measurement of chemical analytes in vitreous humor: stability and precision studies. J Forensic Sci 49:371–374CrossRef Gagajewski A, Murakami MM, Kloss J, Edstrom M, Hillyer M, Peterson GF, Amatuzio J, Apple FS (2004) Measurement of chemical analytes in vitreous humor: stability and precision studies. J Forensic Sci 49:371–374CrossRef
Metadata
Title
Usefulness of a blood glucose and ketone monitoring device as a screening tool for lethal diabetic ketoacidosis
Authors
Pierre-Antoine Peyron
Maëlle Plawecki
Maisy Lossois
Manuela Lotierzo
Eric Baccino
Jean-Paul Cristol
Publication date
01-01-2021
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 1/2021
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-020-02343-8

Other articles of this Issue 1/2021

International Journal of Legal Medicine 1/2021 Go to the issue