Skip to main content
Top
Published in: European Radiology 8/2005

01-08-2005 | Cardiac

3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography

Authors: M. Hackenbroch, K. Nehrke, J. Gieseke, C. Meyer, K. Tiemann, H. Litt, O. Dewald, C. P. Naehle, H. Schild, T. Sommer

Published in: European Radiology | Issue 8/2005

Login to get access

Abstract

This study aimed to evaluate the influence of a new navigator technique (3D MAG) on navigator efficiency, total acquisition time, image quality and diagnostic accuracy. Fifty-six patients with suspected coronary artery disease underwent free breathing navigator gated coronary MRA (Intera, Philips Medical Systems, 1.5 T, spatial resolution 0.9×0.9×3 mm3) with and without 3D MAG. Evaluation of both sequences included: 1) navigator scan efficiency, 2) total acquisition time, 3) assessment of image quality and 4) detection of stenoses >50%. Average navigator efficiencies of the LCA and RCA were 43±12% and 42±12% with and 36±16% and 35±16% without 3D MAG (P<0.01). Scan time was reduced from 12 min 7 s without to 8 min 55 s with 3D MAG for the LCA and from 12 min 19 s to 9 min 7 s with 3D MAG for the RCA (P<0.01). The average scores of image quality of the coronary MRAs with and without 3D MAG were 3.5±0.79 and 3.46±0.84 (P>0.05). There was no significant difference in the sensitivity and specificity in the detection of coronary artery stenoses between coronary MRAs with and without 3D MAG (P>0.05). 3D MAG provides accelerated acquisition of navigator gated coronary MRA by about 19% while maintaining image quality and diagnostic accuracy.
Literature
1.
go back to reference Paulin S, von Schulthess GK, Fossel E, Grayenbuehl HP (1987) MR imaging of the aortic root and proximal coronary arteries. Am J Roentgenol 148:665–670 Paulin S, von Schulthess GK, Fossel E, Grayenbuehl HP (1987) MR imaging of the aortic root and proximal coronary arteries. Am J Roentgenol 148:665–670
2.
go back to reference Sandstede JJ, Pabst T, Beer M, Geis N, Kenn W, Neubauer S, Hahn D (1999) Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. Am J Roentgenol 172:135–139 Sandstede JJ, Pabst T, Beer M, Geis N, Kenn W, Neubauer S, Hahn D (1999) Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. Am J Roentgenol 172:135–139
4.
go back to reference Manning WJ, Li W, Edelman RR (1993) A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 328:828–832 Manning WJ, Li W, Edelman RR (1993) A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 328:828–832
5.
go back to reference Pennell DJ, Keegan J et al. (1993) Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J 70:315–326 Pennell DJ, Keegan J et al. (1993) Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J 70:315–326
6.
go back to reference Duerinckx AJ, Urman MK (1994) Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 193:731–732 Duerinckx AJ, Urman MK (1994) Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 193:731–732
7.
go back to reference Dewey M et al. (2004) Coronary artery disease: new insights and their implications for radiology. Eur Radiol 14(6):1048–1054CrossRefPubMed Dewey M et al. (2004) Coronary artery disease: new insights and their implications for radiology. Eur Radiol 14(6):1048–1054CrossRefPubMed
8.
go back to reference Barkhausen J, Hunold P, Waltering KU (2004) MRI in coronary artery disease. Eur Radiol 14(12):2155–2162 Barkhausen J, Hunold P, Waltering KU (2004) MRI in coronary artery disease. Eur Radiol 14(12):2155–2162
9.
go back to reference Stuber M, Botnar R, Danias PG, Kissinger KV, Manning WJ (1999) Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587 Stuber M, Botnar R, Danias PG, Kissinger KV, Manning WJ (1999) Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587
10.
go back to reference Stuber M, Botnar RM, Danias PG et al. (1999) Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 34(2):524–531CrossRefPubMed Stuber M, Botnar RM, Danias PG et al. (1999) Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 34(2):524–531CrossRefPubMed
11.
go back to reference Spuentrup E et al (2003) Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling. Fortschr Rontgenstr 175:1330–1334 Spuentrup E et al (2003) Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling. Fortschr Rontgenstr 175:1330–1334
12.
go back to reference Sommer T, Hofer U, Hackenbroch M, Meyer C, Flacke S et al. (2002) Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease. Fortschr Rontgenstr 174(4):459–466 Sommer T, Hofer U, Hackenbroch M, Meyer C, Flacke S et al. (2002) Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease. Fortschr Rontgenstr 174(4):459–466
13.
go back to reference Kim WY, Danias PG, Stuber M et al. (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345(26):1863–1869CrossRefPubMed Kim WY, Danias PG, Stuber M et al. (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345(26):1863–1869CrossRefPubMed
14.
go back to reference Maintz D, Apfelbacher FC, Kissinger KV et al. (2004) Coronary MR Angiography: comparison of quantitative and qualitative data from four techniques. Am J Roentgenol 182(2):515–521 Maintz D, Apfelbacher FC, Kissinger KV et al. (2004) Coronary MR Angiography: comparison of quantitative and qualitative data from four techniques. Am J Roentgenol 182(2):515–521
15.
go back to reference Fischer SE, Wickline SA, Lorenz CH (1993) Novel real-time R-wave detection algorithm based on the vektorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 30:191–200 Fischer SE, Wickline SA, Lorenz CH (1993) Novel real-time R-wave detection algorithm based on the vektorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 30:191–200
16.
go back to reference Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ, Botnar RM (1999) Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 99(24):3139–3348 Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ, Botnar RM (1999) Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 99(24):3139–3348
17.
go back to reference Brittain JH, Hu BS, Wright GA et al. (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMed Brittain JH, Hu BS, Wright GA et al. (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMed
18.
go back to reference Harrison R, Bronskill MJ, Henkelmann RM (1995) Magnetization transfer and T2-relaxation components in tissue. Magn Reson Med 33:490–496 Harrison R, Bronskill MJ, Henkelmann RM (1995) Magnetization transfer and T2-relaxation components in tissue. Magn Reson Med 33:490–496
19.
go back to reference Plein S, Jones TR, Ridgway JP et al. (2003) Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. Am J Roentgenol 180:505–512 Plein S, Jones TR, Ridgway JP et al. (2003) Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. Am J Roentgenol 180:505–512
20.
go back to reference Taylor A, Jhooti P et al. (1997) MR navigator-echo monitoring of temporal changes in diaphragmatic position: implications for MR coronary angiography. J Magn Reson Imaging 7:629–636 Taylor A, Jhooti P et al. (1997) MR navigator-echo monitoring of temporal changes in diaphragmatic position: implications for MR coronary angiography. J Magn Reson Imaging 7:629–636
21.
go back to reference Taylor A, Jhooti P et al. (1999) Automated monitoring of diaphragmatic end-expiratory position for real-time navigator echo MR coronary angiography. J Magn Reson Imaging 9:395–401 Taylor A, Jhooti P et al. (1999) Automated monitoring of diaphragmatic end-expiratory position for real-time navigator echo MR coronary angiography. J Magn Reson Imaging 9:395–401
22.
go back to reference Wang Y, Riederer SJ, Ehman RL (1995) Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 33(5):713–779 Wang Y, Riederer SJ, Ehman RL (1995) Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 33(5):713–779
23.
go back to reference Baim DS, Grossman W (eds) (1996) Cardiac catheterization, angiography and intervention, 5th edn. Williams and Wilkins, Philadelphia Baim DS, Grossman W (eds) (1996) Cardiac catheterization, angiography and intervention, 5th edn. Williams and Wilkins, Philadelphia
24.
go back to reference Lansky AJ, Desai K, Leon MB (2002) Quantitative coronary angiography in regression trials: a review of methodologic considerations, endpoint selection, and limitations. Am J Cardiol 89(4A):4B–9B Lansky AJ, Desai K, Leon MB (2002) Quantitative coronary angiography in regression trials: a review of methodologic considerations, endpoint selection, and limitations. Am J Cardiol 89(4A):4B–9B
25.
go back to reference Liu YL et al. (1993) A monitoring feedback and triggering system for reproducible breath-hold MR-imaging. Magn Reson Med 30(4):507–511 Liu YL et al. (1993) A monitoring feedback and triggering system for reproducible breath-hold MR-imaging. Magn Reson Med 30(4):507–511
26.
go back to reference Jhooti P, Gatehouse PD et al. (2000) Phase Ordering With Automatic Window Selection (PAWS): a novel motion-resitant technique for 3D coronary imaging. Magn Reson Med 43:470–480 Jhooti P, Gatehouse PD et al. (2000) Phase Ordering With Automatic Window Selection (PAWS): a novel motion-resitant technique for 3D coronary imaging. Magn Reson Med 43:470–480
27.
go back to reference Flamm S, Muthupillai R (2004) Coronary artery magnetic resonance angiography. J Magn Reson Med 19:686–709 Flamm S, Muthupillai R (2004) Coronary artery magnetic resonance angiography. J Magn Reson Med 19:686–709
28.
go back to reference Weber C et al. (2002) Correlation of 3D MR Coronary angiography with selective coronary angiography: feasibility of the motion-adapted gating technique. Eur Radiol 12:718–726CrossRefPubMed Weber C et al. (2002) Correlation of 3D MR Coronary angiography with selective coronary angiography: feasibility of the motion-adapted gating technique. Eur Radiol 12:718–726CrossRefPubMed
29.
go back to reference Wang Y, Rossman PJ, Grimm RC et al. (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55–60 Wang Y, Rossman PJ, Grimm RC et al. (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55–60
30.
go back to reference Taylor A et al. (1999) Differences between normal subjects and patients with coronary artery disease for three different MR coronary angiography respiratory suppression techniques. J Magn Reson Imaging 9:786–793 Taylor A et al. (1999) Differences between normal subjects and patients with coronary artery disease for three different MR coronary angiography respiratory suppression techniques. J Magn Reson Imaging 9:786–793
31.
go back to reference Edelman RR, Manning WJ, Pearlman J et al. (1993) Human coronary arteries: projection angiograms reconstructed from breath-hold two-dimensional MR images. Radiology 187:719–722 Edelman RR, Manning WJ, Pearlman J et al. (1993) Human coronary arteries: projection angiograms reconstructed from breath-hold two-dimensional MR images. Radiology 187:719–722
32.
go back to reference Manning WJ, Li W, Boyle NG et al. (1993) Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 87:94–104 Manning WJ, Li W, Boyle NG et al. (1993) Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 87:94–104
33.
go back to reference Stuber M, Botnar RM, Danias PG et al. (1999) Submillimeter three dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587 Stuber M, Botnar RM, Danias PG et al. (1999) Submillimeter three dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587
34.
go back to reference Li D, Kaushikkar S, Haacke EM et al. (1996) Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology 201:857–863 Li D, Kaushikkar S, Haacke EM et al. (1996) Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology 201:857–863
Metadata
Title
3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
Authors
M. Hackenbroch
K. Nehrke
J. Gieseke
C. Meyer
K. Tiemann
H. Litt
O. Dewald
C. P. Naehle
H. Schild
T. Sommer
Publication date
01-08-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2731-z

Other articles of this Issue 8/2005

European Radiology 8/2005 Go to the issue