01-08-2005 | Musculoskeletal

Quantitative cartilage volume measurement using MRI: comparison of different evaluation techniques

Authors: Adel Maataoui, Heiko Graichen, Nasreddin D. Abolmaali, Mohammad F. Khan, Jessen Gurung, Ralf Straub, Jun Qian, Stefan Hinterwimmer, Hanns Ackermann, Thomas J. Vogl

Published in: European Radiology | Issue 8/2005

Login to get access

Abstract

This study was aimed to investigate the accuracy and time saving of MRI Argus application in the assessment of cartilage volume in osteoarthritic knees. Twelve knees of patients suffering from osteoarthritis were scanned with a 1.5 T MRI using a 3D gradient echo sequence with selective water excitation. Cartilage volume of the tibial and patellar compartment was determined with a validated multiprocessing computer system (Octane Duo, Silicon Graphics, Mountain View, Calif., USA). The calculated cartilage volumes were compared to the results acquired by the Argus (Siemens Inc., Erlangen, Germany) application software using the MRI data sets. Compared to the multiprocessing computer system a time saving of at least 30 min for cartilage volume determination was achieved. The mean differences of Argus versus the multiprocessing computer system were 4.26±0.84 and 7.80±0.87% for the medial and lateral tibial plateau and 5.94±0.59% for the patella (no statistical significant difference; P>0.05). The applied Argus software can be used for fast and accurate determination of cartilage volume in the knee joint.
Literature
1.
go back to reference Felson DT, Naimark A, Anderson J, Kazis L, Castelli W, Meenan RF (1987) The prevalence of knee osteoarthritis in the elderly. The Framingham Osteoarthritis Study. Arthr Rheum 30:914–918 Felson DT, Naimark A, Anderson J, Kazis L, Castelli W, Meenan RF (1987) The prevalence of knee osteoarthritis in the elderly. The Framingham Osteoarthritis Study. Arthr Rheum 30:914–918
2.
go back to reference Preidler KW, Resnick D (1996) Imaging of osteoarthritis. Radiol Clin N Am 34:259–271 Preidler KW, Resnick D (1996) Imaging of osteoarthritis. Radiol Clin N Am 34:259–271
3.
go back to reference Ayral X, Gueguen A, Ike RW, Bonvarlet JP, Frizziero L, Kalunian K, Moreland LW, Myers S, O’Rourke KS, Roos H, Altman R, Dougados M (1998) Inter-observer reliability of the arthroscopic quantification of chondropathy of the knee. Osteoarthr Cartil 6:160–166 Ayral X, Gueguen A, Ike RW, Bonvarlet JP, Frizziero L, Kalunian K, Moreland LW, Myers S, O’Rourke KS, Roos H, Altman R, Dougados M (1998) Inter-observer reliability of the arthroscopic quantification of chondropathy of the knee. Osteoarthr Cartil 6:160–166
4.
go back to reference Peterfy CG (2002) Imaging of the disease process. Curr Opin Rheumatol 14:590–596 Peterfy CG (2002) Imaging of the disease process. Curr Opin Rheumatol 14:590–596
5.
go back to reference Disler DG (1997) Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: assessment of articular and physeal hyaline cartilage. Am J Roentgenol 169:1117–1123 Disler DG (1997) Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: assessment of articular and physeal hyaline cartilage. Am J Roentgenol 169:1117–1123
6.
go back to reference Disler DG, McCauley TR (1998) Clinical magnetic resonance imaging of articular cartilage. Top Magn Reson Imaging 9:360–376 Disler DG, McCauley TR (1998) Clinical magnetic resonance imaging of articular cartilage. Top Magn Reson Imaging 9:360–376
7.
go back to reference Kawahara Y, Uetani M, Nakahara N, Doiguchi Y, Nishiguchi M, Futagawa S, Kinoshita Y, Hayashi K (1998) Fast spin-echo MR of the articular cartilage in the osteoarthrotic knee. Correlation of MR and arthroscopic findings. Acta Radiol 39:120–125 Kawahara Y, Uetani M, Nakahara N, Doiguchi Y, Nishiguchi M, Futagawa S, Kinoshita Y, Hayashi K (1998) Fast spin-echo MR of the articular cartilage in the osteoarthrotic knee. Correlation of MR and arthroscopic findings. Acta Radiol 39:120–125
8.
go back to reference Roemer FW, Guermazi A, Lynch JA, Peterfy CG, Nevitt MC, Webb N, Li J, Mohr A, Genant HK, Felson DT (2005) Short tau inversion recovery and proton density-weighted fat suppressed sequences for the evaluation of osteoarthritis of the knee with a 1.0 T dedicated extremity MRI: development of a time-efficient sequence protocol. Eur Radiol DOI 10.1007/s00330-004-2608-6 Roemer FW, Guermazi A, Lynch JA, Peterfy CG, Nevitt MC, Webb N, Li J, Mohr A, Genant HK, Felson DT (2005) Short tau inversion recovery and proton density-weighted fat suppressed sequences for the evaluation of osteoarthritis of the knee with a 1.0 T dedicated extremity MRI: development of a time-efficient sequence protocol. Eur Radiol DOI 10.​1007/​s00330-004-2608-6
9.
go back to reference Libicher M, Ivancic M, Hoffmann V, Wenz W (2005) Early changes in experimental osteoarthritis using the Pond–Nuki dog model: technical procedure and initial results of in vivo MR imaging. Eur Radiol 15:390–394 Libicher M, Ivancic M, Hoffmann V, Wenz W (2005) Early changes in experimental osteoarthritis using the Pond–Nuki dog model: technical procedure and initial results of in vivo MR imaging. Eur Radiol 15:390–394
10.
go back to reference Vande Berg BC, Lecouvet FE, Maldague B, Malghem J (2004) MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis. Eur Radiol 14:208–214 Vande Berg BC, Lecouvet FE, Maldague B, Malghem J (2004) MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis. Eur Radiol 14:208–214
11.
go back to reference Guermazi A, Zaim S, Taouli B, Miaux Y, Peterfy CG, Genant HG (2003) MR findings in knee osteoarthritis. Eur Radiol 13:1370–1386 Guermazi A, Zaim S, Taouli B, Miaux Y, Peterfy CG, Genant HG (2003) MR findings in knee osteoarthritis. Eur Radiol 13:1370–1386
12.
go back to reference Graichen H, von Eisenhart-Rothe R, Vogl T, Englmeier KH, Eckstein F (2004) Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging: technical validation for use in analysis of cartilage volume and further morphologic parameters. Arthr Rheum 50:811–816 Graichen H, von Eisenhart-Rothe R, Vogl T, Englmeier KH, Eckstein F (2004) Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging: technical validation for use in analysis of cartilage volume and further morphologic parameters. Arthr Rheum 50:811–816
13.
go back to reference Burgkart R, Glaser C, Hyhlik-Durr A, Englmeier KH, Reiser M, Eckstein F (2001) Magnetic resonance imaging-based assessment of cartilage loss in severe osteoarthritis: accuracy, precision, and diagnostic value. Arthr Rheum 44:2072–2077 Burgkart R, Glaser C, Hyhlik-Durr A, Englmeier KH, Reiser M, Eckstein F (2001) Magnetic resonance imaging-based assessment of cartilage loss in severe osteoarthritis: accuracy, precision, and diagnostic value. Arthr Rheum 44:2072–2077
14.
go back to reference Eckstein F, Reiser M, Englmeier KH, Putz R (2001) In vivo morphometry and functional analysis of human articular cartilage with quantitative magnetic resonance imaging—from image to data, from data to theory. Anat Embryol (Berl) 203:147–173 Eckstein F, Reiser M, Englmeier KH, Putz R (2001) In vivo morphometry and functional analysis of human articular cartilage with quantitative magnetic resonance imaging—from image to data, from data to theory. Anat Embryol (Berl) 203:147–173
15.
go back to reference Piplani MA, Disler DG, McCauley TR, Holmes TJ, Cousins JP (1996) Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images. Radiology 198:855–859 Piplani MA, Disler DG, McCauley TR, Holmes TJ, Cousins JP (1996) Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images. Radiology 198:855–859
16.
go back to reference Eckstein F, Westhoff J, Sittek H, Maag KP, Haubner M, Faber S, Englmeier KH, Reiser M (1998) In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. Am J Roentgenol 170:593–597 Eckstein F, Westhoff J, Sittek H, Maag KP, Haubner M, Faber S, Englmeier KH, Reiser M (1998) In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. Am J Roentgenol 170:593–597
17.
go back to reference Cohen ZA, McCarthy DM, Kwak SD, Legrand P, Fogarasi F, Ciaccio EJ, Ateshian GA (1999) Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements. Osteoarthr Cartil 7:95–109 Cohen ZA, McCarthy DM, Kwak SD, Legrand P, Fogarasi F, Ciaccio EJ, Ateshian GA (1999) Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements. Osteoarthr Cartil 7:95–109
18.
go back to reference Mohr A, Priebe M, Taouli B, Grimm J, Heller M, Brossmann J (2003) Selective water excitation for faster MR imaging of articular cartilage defects: initial clinical results. Eur Radiol 13:686–689 Mohr A, Priebe M, Taouli B, Grimm J, Heller M, Brossmann J (2003) Selective water excitation for faster MR imaging of articular cartilage defects: initial clinical results. Eur Radiol 13:686–689
19.
go back to reference Stammberger T, Eckstein F, Michaelis M, Englmeier KH, Reiser M (1999) Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation. Magn Reson Imaging 17:1033–1042 Stammberger T, Eckstein F, Michaelis M, Englmeier KH, Reiser M (1999) Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation. Magn Reson Imaging 17:1033–1042
20.
go back to reference Graichen H, Springer V, Flaman T, Stammberger T, Glaser C, Englmeier KH, Reiser M, Eckstein F (2000) Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers. Osteoarthr Cartil 8:106–114 Graichen H, Springer V, Flaman T, Stammberger T, Glaser C, Englmeier KH, Reiser M, Eckstein F (2000) Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers. Osteoarthr Cartil 8:106–114
21.
go back to reference Kshirsagar AA, Watson PJ, Tyler JA, Hall LD (1998) Measurement of localized cartilage volume and thickness of human knee joints by computer analysis of three-dimensional magnetic resonance images. Invest Radiol 33:289–299 Kshirsagar AA, Watson PJ, Tyler JA, Hall LD (1998) Measurement of localized cartilage volume and thickness of human knee joints by computer analysis of three-dimensional magnetic resonance images. Invest Radiol 33:289–299
22.
go back to reference Cicuttini FM, Wluka AE, Forbes A, Wolfe R (2003) Comparison of tibial cartilage volume and radiologic grade of the tibiofemoral joint. Arthr Rheum 48:682–688 Cicuttini FM, Wluka AE, Forbes A, Wolfe R (2003) Comparison of tibial cartilage volume and radiologic grade of the tibiofemoral joint. Arthr Rheum 48:682–688
23.
go back to reference Uebelhart D, Malaise M, Marcolongo R, DeVathaire F, Piperno M, Mailleux E, Fioravanti A, Matoso L, Vignon E (2004) Intermittent treatment of knee osteoarthritis with oral chondroitin sulfate: a one-year, randomized, double-blind, multicenter study versus placebo. Osteoarthr Cartil 12:269–276 Uebelhart D, Malaise M, Marcolongo R, DeVathaire F, Piperno M, Mailleux E, Fioravanti A, Matoso L, Vignon E (2004) Intermittent treatment of knee osteoarthritis with oral chondroitin sulfate: a one-year, randomized, double-blind, multicenter study versus placebo. Osteoarthr Cartil 12:269–276
Metadata
Title
Quantitative cartilage volume measurement using MRI: comparison of different evaluation techniques
Authors
Adel Maataoui
Heiko Graichen
Nasreddin D. Abolmaali
Mohammad F. Khan
Jessen Gurung
Ralf Straub
Jun Qian
Stefan Hinterwimmer
Hanns Ackermann
Thomas J. Vogl
Publication date
01-08-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2744-7

Other articles of this Issue 8/2005

European Radiology 8/2005 Go to the issue