Skip to main content
Top
Published in: International Orthopaedics 10/2014

Open Access 01-10-2014 | Original Paper

Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study

Authors: Andrzej Kotela, Ireneusz Kotela

Published in: International Orthopaedics | Issue 10/2014

Login to get access

Abstract

Purpose

The aim of this study was to compare radiological results of total knee arthroplasties (TKAs) performed with patient-specific computed tomography (CT)-based instrumentation and conventional technique. The main study hypothesis was that CT-based patient-specific instrumentation (PSI) increases the accuracy of TKA.

Methods

A prospective, randomized controlled trial was carried out between January and December 2011. A group of 112 patients who met the inclusion and exclusion criteria were enrolled in this study and randomly assigned to an experimental or control group. The experimental group comprised 52 patients operated on with the aid of the Signature™ CT-based implant positioning system. The control group consisted of 60 patients operated on using conventional instrumentation. The radiographic evaluation of implant positioning and overall coronal alignment was performed 12 months after the surgery by using standing anteroposterior radiographs of the entire lower limb and standard lateral radiographs.

Results

Of the 112 patients initially enrolled for the study, 95 were included in the subsequent analyses. There were no statistically significant differences between groups in respect to coronal and sagittal component positioning and overall coronal alignment, except for frontal tibial component positioning. For this parameter, better results were obtained in the control group, with borderline statistical significance.

Conclusions

Our study did not reveal superiority of the CT-based PSI system over conventional instrumentation. Further high-quality investigations of patient-specific systems are absolutely indispensable to assess their utility for TKA. In our opinion, the surgeon applying PSI technology is required to have advanced knowledge and considerable experience with the conventional method.
Literature
1.
2.
3.
go back to reference Lombardi AV Jr, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31(9):927–930PubMedCrossRef Lombardi AV Jr, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31(9):927–930PubMedCrossRef
5.
go back to reference Pang CH, Chan WL, Yen CH, Cheng SC, Woo SB, Choi ST, Hui WK, Mak KH (2009) Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study. J Orthop Surg 17(2):170–173 Pang CH, Chan WL, Yen CH, Cheng SC, Woo SB, Choi ST, Hui WK, Mak KH (2009) Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study. J Orthop Surg 17(2):170–173
6.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef
7.
go back to reference Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed
9.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
10.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg 73(5):709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg 73(5):709–714
12.
go back to reference Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc: Off J ESSKA 20(7):1307–1322. doi:10.1007/s00167-011-1588-8 CrossRef Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc: Off J ESSKA 20(7):1307–1322. doi:10.​1007/​s00167-011-1588-8 CrossRef
14.
go back to reference Roh YW, Kim TW, Lee S, Seong SC, Lee MC (2013) Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res 471(12):3988–3995. doi:10.1007/s11999-013-3206-1 PubMedCrossRef Roh YW, Kim TW, Lee S, Seong SC, Lee MC (2013) Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res 471(12):3988–3995. doi:10.​1007/​s11999-013-3206-1 PubMedCrossRef
17.
go back to reference Thienpont E, Bellemans J, Delport H, Van Overschelde P, Stuyts B, Brabants K, Victor J (2013) Patient-specific instruments: industry's innovation with a surgeon's interest. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2227–2233. doi:10.1007/s00167-013-2626-5 CrossRef Thienpont E, Bellemans J, Delport H, Van Overschelde P, Stuyts B, Brabants K, Victor J (2013) Patient-specific instruments: industry's innovation with a surgeon's interest. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2227–2233. doi:10.​1007/​s00167-013-2626-5 CrossRef
18.
go back to reference Koch PP, Muller D, Pisan M, Fucentese SF (2013) Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2200–2205. doi:10.1007/s00167-013-2625-6 CrossRef Koch PP, Muller D, Pisan M, Fucentese SF (2013) Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2200–2205. doi:10.​1007/​s00167-013-2625-6 CrossRef
19.
go back to reference Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, Giannini S (2014) Intra- and postoperative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 22(3):621–629. doi:10.1007/s00167-013-2667-9 CrossRef Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, Giannini S (2014) Intra- and postoperative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 22(3):621–629. doi:10.​1007/​s00167-013-2667-9 CrossRef
20.
go back to reference Barrett W, Hoeffel D, Dalury D, Mason JB, Murphy J, Himden S (2014) In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. J Arthroplasty 29(2):343–347. doi:10.1016/j.arth.2013.06.029 PubMedCrossRef Barrett W, Hoeffel D, Dalury D, Mason JB, Murphy J, Himden S (2014) In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. J Arthroplasty 29(2):343–347. doi:10.​1016/​j.​arth.​2013.​06.​029 PubMedCrossRef
21.
go back to reference Stempin R, Kotela A, Ostrowska M, Kotela I (2011) Vanguard Signature TKR–first experiences. Chir Narzadow Ruchu Ortop Pol 76(6):350–352PubMed Stempin R, Kotela A, Ostrowska M, Kotela I (2011) Vanguard Signature TKR–first experiences. Chir Narzadow Ruchu Ortop Pol 76(6):350–352PubMed
25.
go back to reference Parratte S, Blanc G, Boussemart T, Ollivier M, Le Corroller T, Argenson JN (2013) Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2213–2219. doi:10.1007/s00167-013-2623-8 CrossRef Parratte S, Blanc G, Boussemart T, Ollivier M, Le Corroller T, Argenson JN (2013) Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2213–2219. doi:10.​1007/​s00167-013-2623-8 CrossRef
26.
go back to reference Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial. Clin Orthop Relat Res 472(1):263–271. doi:10.1007/s11999-013-2997-4 PubMedCrossRef Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial. Clin Orthop Relat Res 472(1):263–271. doi:10.​1007/​s11999-013-2997-4 PubMedCrossRef
27.
go back to reference Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2013) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2194–2199. doi:10.1007/s00167-012-2098-z CrossRef Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2013) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2194–2199. doi:10.​1007/​s00167-012-2098-z CrossRef
28.
go back to reference Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28(3):469–473. doi:10.1016/j.arth.2012.07.012 PubMedCrossRef Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28(3):469–473. doi:10.​1016/​j.​arth.​2012.​07.​012 PubMedCrossRef
31.
go back to reference Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP (2013) Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2206–2212. doi:10.1007/s00167-013-2620-y CrossRef Boonen B, Schotanus MG, Kerens B, van der Weegen W, van Drumpt RA, Kort NP (2013) Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial. Knee Surg Sports Traumatol Arthrosc : Off J ESSKA 21(10):2206–2212. doi:10.​1007/​s00167-013-2620-y CrossRef
33.
go back to reference Skytta ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg : SJS : Off Organ Finnish Surgical Society Scandinavian Surgical Society 98(4):250–253 Skytta ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg : SJS : Off Organ Finnish Surgical Society Scandinavian Surgical Society 98(4):250–253
34.
go back to reference Hunt MA, Fowler PJ, Birmingham TB, Jenkyn TR, Giffin JR (2006) Foot rotational effects on radiographic measures of lower limb alignment. Can J Surg J Canadien de Chirurgie 49(6):401–406 Hunt MA, Fowler PJ, Birmingham TB, Jenkyn TR, Giffin JR (2006) Foot rotational effects on radiographic measures of lower limb alignment. Can J Surg J Canadien de Chirurgie 49(6):401–406
35.
go back to reference Specogna AV, Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2007) Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weightbearing status and associations with dynamic joint load. Am J Sports Med 35(1):65–70. doi:10.1177/0363546506293024 PubMedCrossRef Specogna AV, Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2007) Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weightbearing status and associations with dynamic joint load. Am J Sports Med 35(1):65–70. doi:10.​1177/​0363546506293024​ PubMedCrossRef
36.
go back to reference Langenbach MR, Dohle J, Zirngibl H (2002) Determination of the axis after totalendoprosthesis of the knee: functional X-ray photography as golden standard. Zeitschrift fur Orthopadie und ihre Grenzgebiete 140(1):32–36. doi:10.1055/s-2002-22088 PubMedCrossRef Langenbach MR, Dohle J, Zirngibl H (2002) Determination of the axis after totalendoprosthesis of the knee: functional X-ray photography as golden standard. Zeitschrift fur Orthopadie und ihre Grenzgebiete 140(1):32–36. doi:10.​1055/​s-2002-22088 PubMedCrossRef
37.
go back to reference Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102–106PubMedCrossRef Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102–106PubMedCrossRef
38.
go back to reference Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Computer aided surgery : Official Journal of the International Society for Computer Aided Surgery 11(2):81–86. doi:10.3109/10929080600628985 CrossRef Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Computer aided surgery : Official Journal of the International Society for Computer Aided Surgery 11(2):81–86. doi:10.​3109/​1092908060062898​5 CrossRef
Metadata
Title
Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study
Authors
Andrzej Kotela
Ireneusz Kotela
Publication date
01-10-2014
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 10/2014
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2399-6

Other articles of this Issue 10/2014

International Orthopaedics 10/2014 Go to the issue