Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 1/2013

01-01-2013 | Symposium: Papers Presented at the Annual Meetings of the Knee Society

Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes

Authors: Benjamin M. Stronach, MD, Christopher E. Pelt, MD, Jill Erickson, PA, Christopher L. Peters, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 1/2013

Login to get access

Abstract

Background

Patient-specific instrumentation potentially improves surgical precision and decreases operative time in total knee arthroplasty (TKA) but there is little supporting data to confirm this presumption.

Questions/purposes

We asked whether patient-specific instrumentation would require infrequent intraoperative changes to replicate a single surgeon’s preferences during TKA and whether patient-specific instrumentation guides would fit securely.

Methods

We prospectively evaluated the plan and surgery in 60 patients treated with 66 TKAs performed with patient-specific instrumentation and recorded any changes. A subset of six postoperative radiographic changes to the femoral and tibial components (implant size, coronal and sagittal alignment) was analyzed to determine if surgeon intervention was beneficial. Each guide was evaluated to determine fit. We compared patient demographics and implant sizing in the patient-specific instrumentation group with a control group in which traditional instrumentation was used.

Results

We recorded 161 intraoperative changes in 66 knee arthroplasties (2.4 changes/knee) performed with patient-specific instrumentation. The predetermined implant size was changed intraoperatively in 77% of femurs and 53% of tibias. We identified a subset of 95 intraoperative changes that could be radiographically evaluated to determine if our changes were an improvement or detriment to reaching goal alignment. Eighty-two of the 95 changes (86%) made by the surgeon were an improvement to the recommended alignment or size of patient-specific instrumentation. The guide did not fit securely on eight femurs (12%) and three tibias (5%). Tourniquet time and blood loss were not improved with patient-specific instrumentation.

Conclusions

We caution surgeons against blind acceptance of patient-specific instrumentation technology without supportive data.

Level of Evidence

Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Ecker ML, Lotke PA, Windsor RE, Cella JP. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res. 1987;216:151–158.PubMed Ecker ML, Lotke PA, Windsor RE, Cella JP. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res. 1987;216:151–158.PubMed
2.
go back to reference Fehring TK, Odum SM, Troyer JL, Iorio R, Kurtz SM, Lau EC. Joint replacement access in 2016: a supply side crisis. J Arthroplasty. 2010;25:1175–1181.PubMedCrossRef Fehring TK, Odum SM, Troyer JL, Iorio R, Kurtz SM, Lau EC. Joint replacement access in 2016: a supply side crisis. J Arthroplasty. 2010;25:1175–1181.PubMedCrossRef
3.
go back to reference Hariri S, York SC, O’Connor MI, Parsley BS, McCarthy JC. A resident survey study of orthopedic fellowship specialty decision making and views on arthroplasty as a career. J Arthroplasty. 2011;26:961–968;e961.PubMedCrossRef Hariri S, York SC, O’Connor MI, Parsley BS, McCarthy JC. A resident survey study of orthopedic fellowship specialty decision making and views on arthroplasty as a career. J Arthroplasty. 2011;26:961–968;e961.PubMedCrossRef
4.
go back to reference Howell SM, Kuznik K, Hull ML, Siston RA. Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics. 2008;31:857–863.PubMedCrossRef Howell SM, Kuznik K, Hull ML, Siston RA. Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics. 2008;31:857–863.PubMedCrossRef
5.
go back to reference Klatt BA, Goyal N, Austin MS, Hozack WJ. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty. 2008;23:26–29.PubMedCrossRef Klatt BA, Goyal N, Austin MS, Hozack WJ. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty. 2008;23:26–29.PubMedCrossRef
6.
go back to reference Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87:1487–1497.PubMedCrossRef Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87:1487–1497.PubMedCrossRef
7.
go back to reference Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.PubMedCrossRef
8.
go back to reference Ma HM, Lu YC, Ho FY, Huang CH. Long-term results of total condylar knee arthroplasty. J Arthroplasty. 2005;20:580–584.PubMedCrossRef Ma HM, Lu YC, Ho FY, Huang CH. Long-term results of total condylar knee arthroplasty. J Arthroplasty. 2005;20:580–584.PubMedCrossRef
9.
go back to reference Mont MA, Johnson AJ, Zywiel MG, Bonutti PM. Surgeon perceptions regarding custom-fit positioning technology for total knee arthroplasty. Surg Technol Int. 2010;20:348–351.PubMed Mont MA, Johnson AJ, Zywiel MG, Bonutti PM. Surgeon perceptions regarding custom-fit positioning technology for total knee arthroplasty. Surg Technol Int. 2010;20:348–351.PubMed
10.
go back to reference Nafei A, Kristensen O, Knudsen HM, Hvid I, Jensen J. Survivorship analysis of cemented total condylar knee arthroplasty. A long-term follow-up report on 348 cases. J Arthroplasty. 1996;11:7–10.PubMedCrossRef Nafei A, Kristensen O, Knudsen HM, Hvid I, Jensen J. Survivorship analysis of cemented total condylar knee arthroplasty. A long-term follow-up report on 348 cases. J Arthroplasty. 1996;11:7–10.PubMedCrossRef
11.
go back to reference NIH Consensus Statement on total knee replacement. NIH Consens State Sci Statements. 2003;20:1–34. NIH Consensus Statement on total knee replacement. NIH Consens State Sci Statements. 2003;20:1–34.
12.
go back to reference Pavone V, Boettner F, Fickert S, Sculco TP. Total condylar knee arthroplasty: a long-term followup. Clin Orthop Relat Res. 2001;388:18–25.PubMedCrossRef Pavone V, Boettner F, Fickert S, Sculco TP. Total condylar knee arthroplasty: a long-term followup. Clin Orthop Relat Res. 2001;388:18–25.PubMedCrossRef
13.
go back to reference Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ. Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. Clin Orthop Relat Res. 1993;286:94–102.PubMed Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ. Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. Clin Orthop Relat Res. 1993;286:94–102.PubMed
14.
go back to reference Rodriguez JA, Bhende H, Ranawat CS. Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res. 2001;388:10–17.PubMedCrossRef Rodriguez JA, Bhende H, Ranawat CS. Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res. 2001;388:10–17.PubMedCrossRef
15.
go back to reference Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop. 2008;33:1571–1575.PubMedCrossRef Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop. 2008;33:1571–1575.PubMedCrossRef
16.
go back to reference Watters TS, Mather RC 3rd, Browne JA, Berend KR, Lombardi AV, Bolognesi MP. Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv. 2011;20:112–116.PubMed Watters TS, Mather RC 3rd, Browne JA, Berend KR, Lombardi AV, Bolognesi MP. Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv. 2011;20:112–116.PubMed
Metadata
Title
Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes
Authors
Benjamin M. Stronach, MD
Christopher E. Pelt, MD
Jill Erickson, PA
Christopher L. Peters, MD
Publication date
01-01-2013
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2013
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2573-3

Other articles of this Issue 1/2013

Clinical Orthopaedics and Related Research® 1/2013 Go to the issue

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Total Knee Arthroplasty With a Computer-navigated Saw: A Pilot Study

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Rotating-platform Has No Surface Damage Advantage Over Fixed-bearing TKA