Abstract

Recurrent aortic arch obstruction (RAAO) remains a major cause of morbidity following surgical neonatal repair of coarctation of the aorta (CoA). Elucidating predictors of RAAO can identify high-risk patients and guide postoperative management. The Coarctation index (CoA-I), defined as the ratio of the diameter of the narrowest aortic arch segment to the diameter of the descending aorta, has been used to help diagnose RAAO in neonates following the Norwood Procedure. We sought to assess the predictive value of the CoA-I on RAAO after CoA repair in infants with biventricular circulation. Clinical, surgical, and echocardiographic data of infants with biventricular circulation following neonatal CoA repair between 2010 and 2014 were evaluated. RAAO was defined using a composite quantitative outcome variable: a blood pressure gradient >20, a peak aortic arch velocity >3.5 m/s by echocardiogram, or a catheter-measured peak-to-peak gradient >20 within 2 years of surgery. Univariate and multivariate logistic regression analyses were used. Of the 68 subjects included in the analysis, 15 (22%) met criteria for RAAO. In the multivariate model, only CoA-I (OR 35.89, 95% CI 6.08–211.7, p < 0.0001) and use of patch material (OR 9.26, 95% CI 1.57–54.66, p = 0.014) were associated with increased risk of RAAO. The odds of developing RAAO was higher in patients with a CoA-I less than 0.7 (OR 33.8, 95% CI 5.7–199.5, p < 0.001). Postoperative CoA-I may be used to predict RAAO in patients with biventricular circulation after repair of CoA. Patients with a CoA-I less than 0.7 or patch aortoplasty warrant close follow-up.
Literature
1.
go back to reference Hoffman JIE, Kaplan S (2002) The incidence of congenital heart disease. J Am Coll Cardiol 39(12):1890–1900CrossRefPubMed Hoffman JIE, Kaplan S (2002) The incidence of congenital heart disease. J Am Coll Cardiol 39(12):1890–1900CrossRefPubMed
2.
go back to reference Kansy A, Tobota Z, Maruszewski P, Maruszewski B (2010) Analysis of 14,843 neonatal congenital heart surgical procedures in the European association for cardiothoracic surgery congenital database. Ann Thorac Surg 89(4):1255–1259CrossRefPubMed Kansy A, Tobota Z, Maruszewski P, Maruszewski B (2010) Analysis of 14,843 neonatal congenital heart surgical procedures in the European association for cardiothoracic surgery congenital database. Ann Thorac Surg 89(4):1255–1259CrossRefPubMed
3.
go back to reference Dodge-Khatami A, Backer CL, Mavroudis C (2000) Risk factors for recoarctation and results of reoperation: a 40-year review. J Card Surg 15(6):369–377CrossRefPubMed Dodge-Khatami A, Backer CL, Mavroudis C (2000) Risk factors for recoarctation and results of reoperation: a 40-year review. J Card Surg 15(6):369–377CrossRefPubMed
4.
go back to reference Wood AE, Javadpour H, Duff D, Oslizlok O, Walsh K (2004) Is extended arch aortoplasty the operation of choice for infant aortic coarctation? results of 15 years’ experience in 181 patients. Ann Thorac Surg 77(4):1353–1357CrossRefPubMed Wood AE, Javadpour H, Duff D, Oslizlok O, Walsh K (2004) Is extended arch aortoplasty the operation of choice for infant aortic coarctation? results of 15 years’ experience in 181 patients. Ann Thorac Surg 77(4):1353–1357CrossRefPubMed
5.
go back to reference Wright GE, Nowak CA, Goldberg CS, Ohye RG, Bove EL, Rocchini AP (2005) Extended resection and end-to-end anastomosis for aortic coarctation in infants: results of a tailored surgical approach. Ann Thorac Surg 80(4):1453–1459CrossRefPubMed Wright GE, Nowak CA, Goldberg CS, Ohye RG, Bove EL, Rocchini AP (2005) Extended resection and end-to-end anastomosis for aortic coarctation in infants: results of a tailored surgical approach. Ann Thorac Surg 80(4):1453–1459CrossRefPubMed
6.
go back to reference Younoszai AK, Reddy VM, Hanley FL, Brook MM (2002) Intermediate term follow-up of the end-to-side aortic anastomosis for coarctation of the aorta. Ann Thorac Surg 74(5):1631–1634CrossRefPubMed Younoszai AK, Reddy VM, Hanley FL, Brook MM (2002) Intermediate term follow-up of the end-to-side aortic anastomosis for coarctation of the aorta. Ann Thorac Surg 74(5):1631–1634CrossRefPubMed
7.
go back to reference Burch PT, Cowley CG, Holubkov R et al (2009) Coarctation repair in neonates and young infants: is small size or low weight still a risk factor? J Thorac Cardiovasc Surg 138(3):547–552CrossRefPubMed Burch PT, Cowley CG, Holubkov R et al (2009) Coarctation repair in neonates and young infants: is small size or low weight still a risk factor? J Thorac Cardiovasc Surg 138(3):547–552CrossRefPubMed
8.
go back to reference Fiore AC, Fischer LK, Schwartz T et al (2005) Comparison of angioplasty and surgery for neonatal aortic coarctation. Ann Thorac Surg 80(5):1659–1664CrossRefPubMed Fiore AC, Fischer LK, Schwartz T et al (2005) Comparison of angioplasty and surgery for neonatal aortic coarctation. Ann Thorac Surg 80(5):1659–1664CrossRefPubMed
9.
go back to reference Kumar TK, Zurakowski D, Sharma R, Saini S, Jonas RA (2011) Prediction of recurrent coarctation by early postoperative blood pressure gradient. J Thorac Cardiovasc Surg 142(5):1130–1136CrossRefPubMed Kumar TK, Zurakowski D, Sharma R, Saini S, Jonas RA (2011) Prediction of recurrent coarctation by early postoperative blood pressure gradient. J Thorac Cardiovasc Surg 142(5):1130–1136CrossRefPubMed
10.
go back to reference Mery CM, Guzman-Pruneda FA, Trost JGJ et al (2015) Contemporary results of aortic coarctation repair through left thoracotomy. Ann Thorac Surg 100(3):1039–1046CrossRefPubMed Mery CM, Guzman-Pruneda FA, Trost JGJ et al (2015) Contemporary results of aortic coarctation repair through left thoracotomy. Ann Thorac Surg 100(3):1039–1046CrossRefPubMed
11.
go back to reference Walhout RJ, Lekkerkerker JC, Oron GH, Hitchcock FJ, Meijboom EJ, Bennink GB (2003) Comparison of polytetrafluoroethylene patch aortoplasty and end-to-end anastomosis for coarctation of the aorta. J Thorac Cardiovasc Surg 126(2):521–528CrossRefPubMed Walhout RJ, Lekkerkerker JC, Oron GH, Hitchcock FJ, Meijboom EJ, Bennink GB (2003) Comparison of polytetrafluoroethylene patch aortoplasty and end-to-end anastomosis for coarctation of the aorta. J Thorac Cardiovasc Surg 126(2):521–528CrossRefPubMed
12.
go back to reference Kaushal S, Backer CL, Patel JN et al (2009) Coarctation of the aorta: miderm outcomes of resection with extended end-to-end anastomosis. Ann Thorac Surg 88(6):1932–1938CrossRefPubMed Kaushal S, Backer CL, Patel JN et al (2009) Coarctation of the aorta: miderm outcomes of resection with extended end-to-end anastomosis. Ann Thorac Surg 88(6):1932–1938CrossRefPubMed
13.
go back to reference McElhinney DB, Yang S, Hogarty AN et al (2001) Recurrent arch obstruction after repair of isolated coarctation of the aorta in neonates and young infants: is low weight a risk factor? J Thorac Cardiovasc Surg 122(5):883–890CrossRefPubMed McElhinney DB, Yang S, Hogarty AN et al (2001) Recurrent arch obstruction after repair of isolated coarctation of the aorta in neonates and young infants: is low weight a risk factor? J Thorac Cardiovasc Surg 122(5):883–890CrossRefPubMed
14.
go back to reference Sakurai T, Stickley J, Stumper O et al (2012) Repair of isolated aortic coarctation over two decades: impact of surgical approach and associated arch hypoplasia. Interact CardioVasc Thorac Surg 15:865–870CrossRefPubMedPubMedCentral Sakurai T, Stickley J, Stumper O et al (2012) Repair of isolated aortic coarctation over two decades: impact of surgical approach and associated arch hypoplasia. Interact CardioVasc Thorac Surg 15:865–870CrossRefPubMedPubMedCentral
15.
go back to reference Truong DT, Tani LY, Minich LL, Burch PT, Bardsley TR, Menon SC (2014) Factors associated with recoarctation after surgical repair of coarctation of the aorta by way of thoracotomy in young infants. Pediatr Cardiol 35(1):164–170CrossRefPubMed Truong DT, Tani LY, Minich LL, Burch PT, Bardsley TR, Menon SC (2014) Factors associated with recoarctation after surgical repair of coarctation of the aorta by way of thoracotomy in young infants. Pediatr Cardiol 35(1):164–170CrossRefPubMed
16.
go back to reference Demircin M, Arsan S, Pasaoglu I et al (1995) Coarctation of the aorta in infants and neonates: results and assessment of prognostic variables. J Cardiovasc Surg 36(5):459–464 (Torino) Demircin M, Arsan S, Pasaoglu I et al (1995) Coarctation of the aorta in infants and neonates: results and assessment of prognostic variables. J Cardiovasc Surg 36(5):459–464 (Torino)
17.
go back to reference Karamlou T, Bernasconi A, Jaeggi E et al (2009) Factors associated with arch reintervention and growth of the aortic arch after coarctation repair in neonates weighing less than 2.5 kg. J Thorac Cardiovasc Surg 137(5):1163–1167CrossRefPubMed Karamlou T, Bernasconi A, Jaeggi E et al (2009) Factors associated with arch reintervention and growth of the aortic arch after coarctation repair in neonates weighing less than 2.5 kg. J Thorac Cardiovasc Surg 137(5):1163–1167CrossRefPubMed
18.
go back to reference Wellen SL, Glatz AC, Gillespie MJ, Ravishankar C, Cohen MS (2014) Usefulness of transthoracic echocardiography to accurately diagnose recoarctation of the aorta after the Norwood procedure. Am J Cardiol 114(1):117–121CrossRefPubMed Wellen SL, Glatz AC, Gillespie MJ, Ravishankar C, Cohen MS (2014) Usefulness of transthoracic echocardiography to accurately diagnose recoarctation of the aorta after the Norwood procedure. Am J Cardiol 114(1):117–121CrossRefPubMed
19.
go back to reference Lai WW, Geva T, Shirali GS et al (2006) Guidelines and standard for performance of a pediatric echocardiogram: a report from the task force of the pediatric council of the American society of echocardiography. J Am Soc Echocardiogr 19(12):1413–1430CrossRefPubMed Lai WW, Geva T, Shirali GS et al (2006) Guidelines and standard for performance of a pediatric echocardiogram: a report from the task force of the pediatric council of the American society of echocardiography. J Am Soc Echocardiogr 19(12):1413–1430CrossRefPubMed
20.
go back to reference Colan SD (2009) Normal echocardiographic values for cardiovascular structures. In: Lai WW, Cohen MS, Geva T, Mertens L (eds) Echocardiography in pediatric and congenital heart disease. Wiley, West Sussex, pp 765–785 Colan SD (2009) Normal echocardiographic values for cardiovascular structures. In: Lai WW, Cohen MS, Geva T, Mertens L (eds) Echocardiography in pediatric and congenital heart disease. Wiley, West Sussex, pp 765–785
21.
go back to reference Dannevig I, Dale HC, Liestol K, Lindemann R (2005) Blood pressure in the neonate: three non-invasive oscillometric pressure monitors compared with invasively measured blood pressure. Acta Paediatr 94(2):191–196CrossRefPubMed Dannevig I, Dale HC, Liestol K, Lindemann R (2005) Blood pressure in the neonate: three non-invasive oscillometric pressure monitors compared with invasively measured blood pressure. Acta Paediatr 94(2):191–196CrossRefPubMed
22.
go back to reference O’Shea J, Dempsey EM (2009) A comparison of blood pressure measurements in newborns. Am J Perinatol 26(2):113–116CrossRefPubMed O’Shea J, Dempsey EM (2009) A comparison of blood pressure measurements in newborns. Am J Perinatol 26(2):113–116CrossRefPubMed
23.
go back to reference Backer CL, Paape K, Zales VR, Weigel TJ, Mavroudis C (1995) Coarctation of the aorta. repair with polytetrafluoroethylene patch aortoplasty. Circulation 92(9):132–136CrossRef Backer CL, Paape K, Zales VR, Weigel TJ, Mavroudis C (1995) Coarctation of the aorta. repair with polytetrafluoroethylene patch aortoplasty. Circulation 92(9):132–136CrossRef
24.
go back to reference Zehr KJ, Gillinov AM, Redmond JM et al (1995) Repair of coarctation of the aorta in neonates and infants: a thirty-year experience. Ann Thorac Surg 59(1):33–41CrossRefPubMed Zehr KJ, Gillinov AM, Redmond JM et al (1995) Repair of coarctation of the aorta in neonates and infants: a thirty-year experience. Ann Thorac Surg 59(1):33–41CrossRefPubMed
25.
go back to reference Wisotzkey BL, Hornik CP, Green AS, Barker PCA (2015) Comparison of invasive and non-invasive pressure gradients in aortic arch obstruction. Cardiol Young 25:1348–1357CrossRefPubMedPubMedCentral Wisotzkey BL, Hornik CP, Green AS, Barker PCA (2015) Comparison of invasive and non-invasive pressure gradients in aortic arch obstruction. Cardiol Young 25:1348–1357CrossRefPubMedPubMedCentral
26.
go back to reference Giardini A, Tacy TA (2009) Pressure recovery explains Doppler overestimation of invasive pressure gradient across segmental vascular stenosis. Echocardiography 27(1):21–31CrossRefPubMed Giardini A, Tacy TA (2009) Pressure recovery explains Doppler overestimation of invasive pressure gradient across segmental vascular stenosis. Echocardiography 27(1):21–31CrossRefPubMed
Metadata
Title
Coarctation Index Predicts Recurrent Aortic Arch Obstruction Following Surgical Repair of Coarctation of the Aorta in Infants
Authors
Gregory Adamson
Tara Karamlou
Phillip Moore
Luz Natal-Hernandez
Sarah Tabbutt
Shabnam Peyvandi
Publication date
01-08-2017
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 6/2017
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-017-1651-4

Other articles of this Issue 6/2017

Pediatric Cardiology 6/2017 Go to the issue