Skip to main content
Top
Published in: Clinical Oral Investigations 9/2016

01-12-2016 | Original Article

Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns

Authors: S. Berrendero, M. P. Salido, A. Valverde, A. Ferreiroa, G. Pradíes

Published in: Clinical Oral Investigations | Issue 9/2016

Login to get access

Abstract

Objectives

To compare the fit of all-ceramic crowns fabricated from conventional silicone impressions with the fit of all-ceramic crowns fabricated from intraoral digital impressions.

Methods

Thirty patients with 30 posterior teeth with a prosthetic demand were selected. Zirconia-based ceramic crowns were made using an intraoral digital impression system (Ultrafast Optical Sectioning technology) (digital group, D) and 2-step silicone impression technique (conventional group, C).
To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation using ultra-flow silicone. Each crown was embedded in resin to stabilize the registered interface. Specimens were sectioned in buccolingual orientation, and internal misfit was measured at different areas using stereomicroscopy (×40).
Data was analysed using Student’s t test and Mann-Whitney test (α = 0.05).

Results

No statistically significant differences were found (P > 0.05) between two groups. The mean internal misfit and mean marginal misfit were 170.9 μm (SD = 119.4)/106.6 μm (SD = 69.6) for group D and 185.4 μm (SD = 112.1)/119.9 μm (SD = 59.9) for group C.

Conclusion

Ceramic crowns fabricated using an intraoral scanner are comparable to elastomer conventional impressions in terms of their marginal and internal fits. The mean marginal fit in both groups was within the limits of clinical acceptability.

Clinical significance

Impressions based on Ultrafast Optical Sectioning technology can be used for manufacturing ceramic crowns in a normal workflow, with the same results as silicone conventional impressions.
Literature
1.
2.
go back to reference Hunter A, Hunter AR (1990) Gingival margins for crowns: a review and discusion II. Discrepancies and configurations. J Prosthet Dent 64:636–642CrossRefPubMed Hunter A, Hunter AR (1990) Gingival margins for crowns: a review and discusion II. Discrepancies and configurations. J Prosthet Dent 64:636–642CrossRefPubMed
3.
go back to reference Beuer F, Aggstaller H, Richter J, Edelhoff D, Wolfgang G (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM fabricated zirconia crowns copings. Quintessence Int 40:243–250PubMed Beuer F, Aggstaller H, Richter J, Edelhoff D, Wolfgang G (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM fabricated zirconia crowns copings. Quintessence Int 40:243–250PubMed
6.
go back to reference Sailer I, Fehér A, Filser F, Gauckler LI, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed Sailer I, Fehér A, Filser F, Gauckler LI, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed
7.
go back to reference KL K, Campbell CS (2000) Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 84:492–498CrossRef KL K, Campbell CS (2000) Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 84:492–498CrossRef
8.
go back to reference Mitchell CA, Pintado MR (2001) Nondestructive, in vitro quantification of crown margins. J Prosthet Dent 85:575–584CrossRefPubMed Mitchell CA, Pintado MR (2001) Nondestructive, in vitro quantification of crown margins. J Prosthet Dent 85:575–584CrossRefPubMed
9.
go back to reference Reich S, Wichmann M, Nkenke E (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113:174–179CrossRefPubMed Reich S, Wichmann M, Nkenke E (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113:174–179CrossRefPubMed
10.
go back to reference Reich S, Kappe K, Teschner H, Schimitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116:579–584CrossRefPubMed Reich S, Kappe K, Teschner H, Schimitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116:579–584CrossRefPubMed
11.
go back to reference Kohorst P, Brinkmann H, Li J, Borchers L, Stiesch M (2009) Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided manufacturing systems. Eur J Oral Sci 117:319–325CrossRefPubMed Kohorst P, Brinkmann H, Li J, Borchers L, Stiesch M (2009) Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided manufacturing systems. Eur J Oral Sci 117:319–325CrossRefPubMed
12.
go back to reference McLean J, Von Fraunhofer JA (1971) The estimation of cement film thickness by an in vitro technique. Br Dent J 13:107–111CrossRef McLean J, Von Fraunhofer JA (1971) The estimation of cement film thickness by an in vitro technique. Br Dent J 13:107–111CrossRef
13.
go back to reference Al-Bakri IAHD, Al-Omari WM (2007) The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 18:29–33PubMed Al-Bakri IAHD, Al-Omari WM (2007) The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 18:29–33PubMed
14.
go back to reference Beuer F, Edelhoff D, Schweiger J (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated resto- rations. Br Dent J 204:505–511CrossRefPubMed Beuer F, Edelhoff D, Schweiger J (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated resto- rations. Br Dent J 204:505–511CrossRefPubMed
15.
go back to reference JEK A e S, Edelhoff D, Stimmelmayr M, Güth JF (2014) Marginal internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Invest 18:515–523CrossRef JEK A e S, Edelhoff D, Stimmelmayr M, Güth JF (2014) Marginal internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Invest 18:515–523CrossRef
16.
go back to reference Birnbaum NS, Aaronson HB (2008) Dental impression using 3D digital scanners: virtual becomes reality. Compend Contin Educ Dent 29:494–505PubMed Birnbaum NS, Aaronson HB (2008) Dental impression using 3D digital scanners: virtual becomes reality. Compend Contin Educ Dent 29:494–505PubMed
17.
go back to reference Christensen GJ (2008) Will digital impressions eliminate the cur- rent problems with conventional impressions? J Am Dent Assoc 139:761–763CrossRefPubMed Christensen GJ (2008) Will digital impressions eliminate the cur- rent problems with conventional impressions? J Am Dent Assoc 139:761–763CrossRefPubMed
18.
go back to reference Suárez M, González de Villaumbrosia P, Pradíes G, Lozano J (2003) Comparison of the marginal fit Procera AllCeram crowns with two finish lines. Int J Prosthodont 16:229–233PubMed Suárez M, González de Villaumbrosia P, Pradíes G, Lozano J (2003) Comparison of the marginal fit Procera AllCeram crowns with two finish lines. Int J Prosthodont 16:229–233PubMed
19.
go back to reference Conrad H, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98:389–404CrossRefPubMed Conrad H, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98:389–404CrossRefPubMed
20.
21.
go back to reference Duret F (1996) CAD/CAM in dentistry: present and future applications. In current concepts. Quintessence Int 27:433–436 Duret F (1996) CAD/CAM in dentistry: present and future applications. In current concepts. Quintessence Int 27:433–436
22.
go back to reference Schaefer O, Decker M, Wittstock F, Kuepper H, Guentsch A (2014) Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro. J Dent 42:677–683CrossRefPubMed Schaefer O, Decker M, Wittstock F, Kuepper H, Guentsch A (2014) Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro. J Dent 42:677–683CrossRefPubMed
24.
go back to reference Logozzo S, Zannetti EM, Franceschini G (2014) Recent advances in dental optics. Part I: 3D intraoral scanners for restorative dentistry. Opt Lasers Eng 54:203–221CrossRef Logozzo S, Zannetti EM, Franceschini G (2014) Recent advances in dental optics. Part I: 3D intraoral scanners for restorative dentistry. Opt Lasers Eng 54:203–221CrossRef
25.
go back to reference Wismeijer D, Mans R, Van Genuchten M, Reijers HA (2014) Patients’ preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (intraoral scan) of dental implants. Clin Oral Impl Res 25:1113–1118CrossRef Wismeijer D, Mans R, Van Genuchten M, Reijers HA (2014) Patients’ preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (intraoral scan) of dental implants. Clin Oral Impl Res 25:1113–1118CrossRef
26.
go back to reference Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 14 Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 14
27.
go back to reference Fasbinder DJ (2010) Innovation for restorative treatment. Compend Contin Educ Dent 31:2–11PubMed Fasbinder DJ (2010) Innovation for restorative treatment. Compend Contin Educ Dent 31:2–11PubMed
28.
go back to reference Brawek SW, Wolfarts S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems. Clin Oral Invest 17:2119–2125. doi:10.1007/s00784-013-0923-5 CrossRef Brawek SW, Wolfarts S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems. Clin Oral Invest 17:2119–2125. doi:10.​1007/​s00784-013-0923-5 CrossRef
29.
go back to reference Ender A, Melh A (2013) Influence of scanind strategies on the accuracy of digital intraoral scanning systems. Int Comput Dent 16:11–21 Ender A, Melh A (2013) Influence of scanind strategies on the accuracy of digital intraoral scanning systems. Int Comput Dent 16:11–21
30.
go back to reference Martins LM, Lorenzoni FC, Melo AO, Silva LM, Oliveira JL, Oliveira PC, et al. (2012) Internal fit of two all ceramic systems and metal ceramic crowns. J App Oral Sci 20:235–240CrossRef Martins LM, Lorenzoni FC, Melo AO, Silva LM, Oliveira JL, Oliveira PC, et al. (2012) Internal fit of two all ceramic systems and metal ceramic crowns. J App Oral Sci 20:235–240CrossRef
31.
go back to reference Tsitrou EA, Northeast SE, Van Noort R (2007) Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD-CAM. J Dent 35:68–73CrossRefPubMed Tsitrou EA, Northeast SE, Van Noort R (2007) Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD-CAM. J Dent 35:68–73CrossRefPubMed
32.
go back to reference Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116:272–279CrossRefPubMed Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116:272–279CrossRefPubMed
33.
go back to reference Souza ROA, Özcan M, Pavanelli CA, Buso L, Lombardo GH, Michida SM, Mesquita AM, Bottino MA (2012) Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD-CAM system. J Prosthodont 21:94–100CrossRefPubMed Souza ROA, Özcan M, Pavanelli CA, Buso L, Lombardo GH, Michida SM, Mesquita AM, Bottino MA (2012) Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD-CAM system. J Prosthodont 21:94–100CrossRefPubMed
34.
go back to reference Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns validation of the silicone replic method. J Oral Rehabil 35:116–122CrossRefPubMed Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns validation of the silicone replic method. J Oral Rehabil 35:116–122CrossRefPubMed
35.
go back to reference Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Invest 15:521–526CrossRef Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Invest 15:521–526CrossRef
36.
go back to reference Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent Feb 43:201–208CrossRef Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent Feb 43:201–208CrossRef
37.
go back to reference Holmes JR, Bayne SC, Holland GA, Sulik W (1989) Considerations in measurement of marginal fit. J Prosthet Dent:405–408 Holmes JR, Bayne SC, Holland GA, Sulik W (1989) Considerations in measurement of marginal fit. J Prosthet Dent:405–408
38.
go back to reference Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B (2015) Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Invest 19(8):2027–2034 Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B (2015) Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Invest 19(8):2027–2034
39.
go back to reference Keul C, Stawarczy B, Erdelt KJ, Beuer F, Edelhoff D, Guth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater J 30:400–407CrossRef Keul C, Stawarczy B, Erdelt KJ, Beuer F, Edelhoff D, Guth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater J 30:400–407CrossRef
40.
go back to reference Euán R, Figueras-Álvarez O, Cabratosa-Temes J, Oliver-Parra R (2014) Marginal adaptation of zirconium dioxide copings: influence of the CAD/CAM system and the finish line design. J Prosthet Dent 112:155–162CrossRefPubMed Euán R, Figueras-Álvarez O, Cabratosa-Temes J, Oliver-Parra R (2014) Marginal adaptation of zirconium dioxide copings: influence of the CAD/CAM system and the finish line design. J Prosthet Dent 112:155–162CrossRefPubMed
41.
go back to reference Ng J, Ruse D, Wyatt C (2014) A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 112:555–560CrossRefPubMed Ng J, Ruse D, Wyatt C (2014) A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 112:555–560CrossRefPubMed
42.
go back to reference Fahmy NZ (2011) Influence of veneering materials on the marginal fit and fracture resistance of an alumina core system. J Prosthodont 20:45–51CrossRefPubMed Fahmy NZ (2011) Influence of veneering materials on the marginal fit and fracture resistance of an alumina core system. J Prosthodont 20:45–51CrossRefPubMed
43.
go back to reference Ferreira Quintas A, Oliveira F, Bottino MA (2004) Vertical marginal discrepancy of ceramic copings with differents ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 92:250–257CrossRef Ferreira Quintas A, Oliveira F, Bottino MA (2004) Vertical marginal discrepancy of ceramic copings with differents ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 92:250–257CrossRef
44.
go back to reference Beuer F, Naumann M, Gernet W, Sorensen JA (2009) Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Invest 13:34–39 Beuer F, Naumann M, Gernet W, Sorensen JA (2009) Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Invest 13:34–39
45.
go back to reference Grenade C, Mainjot A, Vanheusden A (2011) Fit of single tooth zirconia copings: comparison between vairous manufacuring processes. J Prosthet Dent 105:249–255CrossRefPubMed Grenade C, Mainjot A, Vanheusden A (2011) Fit of single tooth zirconia copings: comparison between vairous manufacuring processes. J Prosthet Dent 105:249–255CrossRefPubMed
Metadata
Title
Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
Authors
S. Berrendero
M. P. Salido
A. Valverde
A. Ferreiroa
G. Pradíes
Publication date
01-12-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 9/2016
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-016-1714-6

Other articles of this Issue 9/2016

Clinical Oral Investigations 9/2016 Go to the issue